• Title/Summary/Keyword: 탐촉자

Search Result 169, Processing Time 0.024 seconds

A Performance Improvement of Ultrasonic Diagnosis Transducer by Transient Acoustic Field Analysis (과도음장 해석을 통한 초음파 진단 탐촉자의 성능 개선)

  • 박은주;송행용;김무준;김동현;이수성;하강열
    • The Journal of the Acoustical Society of Korea
    • /
    • v.21 no.8
    • /
    • pp.744-756
    • /
    • 2002
  • The transient acoustic fields formed by a 3.5 ㎒ curved linear array transducer which is commonly used in ultrasonic medical imaging system for diagnosis of abdomen are systematically analyzed to obtain new design parameters for the better acoustic image. In the analysis with an assumption of radiating waveform, element size, radius of curvature, amplitude apodization are considered as parameters giving constitutive relations with the fields. As simulation results, appropriate new parameters with the reduced curvature and elevation aperture and the apodization of Hamming window, which make an improved acoustic beam with lower side lobe levels than a conventional typical transducer, are obtained.

UT Inspection Technique of Cast Stainless Steel Piping Welds Using Low Frequency TRL UT Probe (저주파수 TRL 탐촉자를 이용한 Cast Stainless Steel 배관 용접부 초음파탐상기법)

  • Shin, Keon-Cheol;Chang, Hee-Jun;Jeong, Young-Cheol;Noh, Ik-Jun;Lee, Dong-Jin
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.6 no.1
    • /
    • pp.29-36
    • /
    • 2010
  • Ultrasonic inspection of heavy walled cast austenitic stainless steel(CASS)welds is very difficult due to complex and coarse grained structure of CASS material. The large size of anisotropic grain strongly affects the propagation of ultrasound by severe attenuation, change in velocity, and scattering of ultrasonic energy. therefore, the signal patterns originated from flaws can be difficult to distinguish from scattered signals. To improve detection and sizing capability of ID connected defect for heavy walled CASS piping welds, the low frequency segmented TRL Pulse Echo and Phased Array probe has been developed. The experimental studies have been performed using CASS pipe mock-up block containing artificial reflectors(ID connected EDM notch). The automatic pulse echo and phase array technique is applied the detection and the length sizing of the ID connected artificial reflectors and the results for detection and sizing has been compared respectively. The goal of this study is to assess a newly developed ultrasonic probe to improve the detection ability and the sizing of the crack in coarse-grained CASS components.

  • PDF

Effect of Ultrasonic Waves on Fiber Orientation in CFRP Laminated Composites

  • Park, Je-Woong;Kweon, Young-Sub;Im, Kwang-Hee;Hsu, David;Kim, Sun-Kyu;Yang, In-Young
    • Journal of Korea Foundry Society
    • /
    • v.27 no.6
    • /
    • pp.255-257
    • /
    • 2007
  • 최근에는 탄소섬유복합재료(CFRP)는 우주 및 민간 항공산업분야에 널리 활용이 되고 있는 실정이다. CFRP 복합재는 적층구성에 따라 기계물성치 및 강성에 크게 영향이 미치므로 가장 대표적인 직교이방성 적층재의 적층배향을 비파괴 탐상하는 것은 중요하다. 본 연구에서는 CFRP 적층재의 섬유배향에 가장 민감한 초음파 전단파를 활용하기 위해 2개의 종파 초음탐촉자를 이용하는 새로운 기법을 제안하였다. 또한 초음파 전단파를 발생하기 위해서는 탐촉자 밑면에 접촉매질인 태운꿀을 사용하는데 초음파시험하는 도중에 물성치중에 하나인 즉 점성이 상당히 변하게 된다. 이러한 문제를 해결하기 위해 2개의 종파용 초음파탐촉자를 이용해 전단파를 발생시킴으로써 접촉매질문제를 상당히 경감할 수 있는 것으로 나타났으며 여기에서 발생한 전단파가 CFRP 복합적층판의 섬유배향에 매우 민감함을 알 수 있었다.

Introduction to nondestructive testing

  • 정용무
    • Journal of Welding and Joining
    • /
    • v.12 no.4
    • /
    • pp.1-10
    • /
    • 1994
  • 이 글에서는 비파괴검사개론에 관하여 알아보았다. 1. 비파괴검사의 의의 1.1 비파괴검사의 역사 1.2 비파괴검사의 원리 1.3 비파괴검사의 목적과 역할 1.3.1 품질관리 1.3.2 생산원가의 절감 1.3.3 품질의 평가 1.3.4 점검 1.4 비파괴검사자의 역할 2. 비파괴검사자의 방법 2.1 방사선투과시험 2.1.1 직접촬영법 2.1.2 투시법 2.1.3 전자사진법 2.1.4 계기법 2.2 초음파탐상시험 2.2.1 음향검사와 초음파탐상 2.2.2 초음파의 성질과 종류 2.2.3 접촉매질 2.2.4 초음파 탐상 방법 2.2.5 초음파 탐촉자 2.3 자기탐상시험 2.3.1 자기탐상 원리 2.3.2 자기탐상 방법 1) 자장측정 탐상법 2) 자기기록 탐상법 3) 탐사 코일법 4) 자분탐상시험 2.3.3 자분탐상시험 2.4 침투탐상시험 2.4.1 침투탐상시험의 원리 2.4.2 침투탐상시험법의 기본 1) 침투탐상시험의 종류 2) 현상체의 종류 2.4.3 침투탐상시험의 장단점 2.5 전자유도시험 (와전류탐상법) 2.5.1 와전류의 발생과 탐지 2.5.2 와전류의 탐지 2.5.3 와전류 탐촉자 2.5.4 와전류 탐상시험의 적용과 장단점.

  • PDF

The Electro-Mechanical Signal Transformation of Piezo-Electric Transducer (압전식 탐촉자의 기계-전기 신호 변환)

  • Ahn, Tae-Won
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.20 no.2
    • /
    • pp.110-115
    • /
    • 2000
  • The electromechanical reciprocity identity is introduced to relate the voltage at the terminals of a transducer to the acoustic wavefields scattered from the specimen. The voltage at the terminals of the transducer is expressed as an integral equation in terms of the displacement and stress of the incident and scattered waves on the closed surface enclosing the scatterer. The equation is used to relate the voltage at the terminals of an acoustic microscope's transducer to the acoustic wavefields at the interface between the specimen and the coupling fluid. The voltage calculated using the integral equation is compared with the experimental result.

  • PDF

A Study for the Proximity Condition and Optimum Analysis Technique for the SG Tubes (증기발생기 세관에 대한 근접도 상태 및 최적 평가기법에 대한 연구)

  • Shin, Ki-Seok;Moon, Gyoon-Young;Lee, Young-Ho
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.4 no.2
    • /
    • pp.34-39
    • /
    • 2008
  • Steam Generator(SG) tubes are classified as one of the key components in nuclear power plants, and they should be periodically examined by the intensified management program for the assurance and diagnosis of their structural integrity. In this study, we use the optimum analysis technique to draw the detection and categorization of bowing(BOW) signals; abnormal tube-to-tube proximity in the SG upper bundle free span area. The locations in which BOW signals are detected likely have latent degradation of ODSCC(Outer Diameter Stress Corrosion Cracking). For the sake of timely and correct detection of BOW signals and diagnosis of ODSCC, we carried out the experimental demonstrations using a reduced mock-up. And we validated the MRPC(Motorized Rotating Pancake Coil) analysis technique is better than the bobbin. Hence, it comes to conclusion that the optimum analysis technique can be a good alternative for the reliable SG tube examination.

  • PDF

Effect of System Dependent Harmonics in the Measurement of Ultrasonic Nonlinear Parameter by Using Contact Transducers (접촉식 탐촉자를 이용한 초음파 비선형 파라미터의 측정에서 시스템에 의존하는 고조파 성분의 영향)

  • Choi, Ik-Hwang;Lee, Jae-Ik;Kwon, Goo-Do;Jhang, Kyung-Young
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.28 no.4
    • /
    • pp.358-363
    • /
    • 2008
  • Ultrasonic nonlinearity has been considered as a promising method to evaluate the micro damage of material; however, its magnitude is so small that its measurement is not easy. Thus, in this study, we investigate the effects of such experimental system dependent factors in the measurement of ultrasonic nonlinear parameter by using contact PZT transducer. Experimental results showed that the effect of system dependent nonlinearity is reduced when the contact pressure and transducer input voltage are sufficiently large. These results will be very useful to find out the proper experiment condition to measure rather accurate nonlinear parameter.

Design and Array Signal Suggestion of Array Type Pulsed Eddy Current Probe for Health Monitoring of Metal Tubes (금속배관 건전성 감시를 위한 배열형 펄스와전류 탐촉자의 설계 및 배열신호 제안)

  • Shin, Young Kil
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.35 no.5
    • /
    • pp.291-298
    • /
    • 2015
  • An array type probe for monitoring metal tubes is proposed in this paper which utilizes peak value and peak time of a pulsed eddy current(PEC) signal. The probe consists of an array of encircling coils along a tube and the outside of coils is shielded by ferrite to prevent source magnetic fields from directly affecting sensor signals since it is the magnetic fields produced by eddy currents that reflect the condition of metal tubes. The positions of both exciter and sensor coils are consecutively moved automatically so that manual scanning is not necessary. At one position of send-receive coils, peak value and peak time are extracted from a sensor PEC signal and these data are accumulated for all positions to form an array type peak value signal and an array type peak time signal. Numerical simulation was performed using the backward difference method in time and the finite element method for spatial analysis. Simulation results showed that peak value increases and the peak appears earlier as the defect depth or length increases. The proposed array signals are shown to be excellent in reflecting the defect location as well as variations of defect depth and length within the array probe.