Study on Design Method of Tunnel-type Ammunition Storage Chamber (터널형 탄약고의 격실 설계 방법에 대한 연구)

  • Park, Sangwoo;Baek, Jangwoon;Park, Young-Jun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.20 no.3
    • /
    • pp.279-287
    • /
    • 2020
  • Recently, the demand for underground-type ammunition storage facilities has increased. Comparing with a ground-type ammunition storage facility, the underground-type ammunition storage facility can decrease the standard of safety distance because fragment and blast wave can be locked in the rock formation. However, the absence of a design method on the underground-type ammunition storage chamber became a major setback for the construction promotion. In this study, the process for designing an overall configuration of the underground-type ammunition storage facility was provided. First, the determination method for configuration and number of the chamber was developed by performing the ammunition storage simulation. Then, a tunnel (i.e., transfer channel for vehicles) and designed chambers can be arranged on the basis of safety distance standard. The safety distance standard also should be considered for determining the location and the size of entrances because of the blast wave and fragment effect at the entrances when an explosion is generated inside a chamber. In addition, considerations on the design for the waterproof and the drainage of subsurface water were analyzed through construction cases. Finally, an example of designing underground-type ammunition storage chambers was provided in order to verify the developed design process.

The Design and Protective Capacity Assessment of the Prefabricated PC Arch Ammo Magazines (아치형 조립식 PC 탄약고 설계 및 방호성능 평가)

  • Park, Jang-Kweon;Lim, Chul-Won;Ryu, Dong-Woo;Son, Ki-Young;Baek, Jong-Hyuk;Park, Young-Jun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.14 no.6
    • /
    • pp.615-621
    • /
    • 2014
  • This study suggests the design and assembly drawing of the prefabricated precast concrete arch ammo magazines using the numerical analysis as well as the explosion verification test. The protective capacity of the proposed magazines is identified with the maximum support rotation angles measured by explosion verification tests according to the U.S. Unified Facility Criteria 3-340-02. Using numerical analysis, it is examined that oval-type members are better than the semi-circle ones in terms of protective capacity. Based on this numerical results, the design and assemble drawing for the prefabricated precast concrete arch ammo magazine are developed. It is identified that the structure constructed by invented design and assembly drawing has enough protective capacity against blast pressure caused by 133.75kg TNT explosion. The detonation point cannot be open due to the military security. In sum, it could be concluded that the ammo magazine proposed in this study has reliable protective capacity with enough redundancy. The redundancy means that there are more economic design approach with reducing the curved wall thickness.

Logistics Development Plan for Underground Ammunition Depots based on Network (네트워크 기반 지하형 탄약고의 물류 발전방안 연구)

  • Kim, Byungkyoo
    • Journal of Internet Computing and Services
    • /
    • v.23 no.3
    • /
    • pp.137-145
    • /
    • 2022
  • The logistics of ammunition stored in the underground ammunition warehouse has more difficulties than the logistics of ammunition stored on the ground due to the nature of the storage space. This study was conducted to solve the logistics of underground ammunition warehouse by improving these problems. And six items such as guard, safety, environment, supply system, equipment, facilities, and life management were selected for the improvement of logistics. And AHP was analyzed by Expert Choice program by conducting a survey to experts. As a result of the analysis, it was confirmed that the importance was high in the order of safety, guard, life management, equipment facilities, supply system, and environment. Based on the selected items and the results of the survey, a plan to build a network-based integrated platform that can improve logistics in an underground ammunition warehouse was presented. This study will be used as a basis for the establishment of an integrated platform when constructing an underground ammunition warehouse in the future. This study can be applied to storage facilities that store other materials in the military, and it is expected to be applied to large commercial storage facilities.

Study for Reducing Safety Distance by Installing Ammunition Storage Facility in Underground (탄약저장시설 지하화에 따른 안전거리 축소방안 연구)

  • Park, Sangwoo;Jun, Jonghoon;Choi, Hangseok;Park, Young-Jun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.20 no.3
    • /
    • pp.253-260
    • /
    • 2020
  • With increasing interest in an underground-type ammunition storage facility, several design results have been provided recently. However, since not only experts in the tunnel but also military persons in charge of ammunition have not fully understood the safety distance standard, reliable design results are not being produced. In this study, the effective design method of an underground-type ammunition storage facility was provided by analyzing the current safety distance standard. First, the critical safety distances that dominate the size of construction site for underground-type ammunition storage facilities were evaluated, which are the layout of chambers and the configuration of the entrances. Then, the decreasing effect of inter-chamber distance was studied according to the rock type and the storage density of ammunition. In addition, the method of designing tunnels with parallel lines and two-floors was considered for arranging more chambers while complying with the safety distance standards. In particular, numerical simulations were carried out to determine the satisfaction of the safety distance standards when an underground-type ammunition storage facility is composed of two-floor and the decreasing effect of inter-chamber distance according to the inner explosive pressure reduction. Finally, the method to adjust the size of entrances and the path of pressure were studied for decreasing the safety distance at the entrance.

A Physical Study on the Dew Problem of Igloo Type Military Magazine (이그루 탄약고 결로문제 해결에 대한 물리적 고찰 (내부온도를 높여서 상대습도를 낮추는 방안에 대하여))

  • Lee, Sung-Taee
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.8 no.3 s.22
    • /
    • pp.111-115
    • /
    • 2005
  • The compact storage of ammunitions in magazine causes serious dew problem on the surface of the shell. Lots of previous studies try to solve this problem by increasing the temperature of air in military magazine. They tried to reduce relative humidity by increasing the temperature of air, but all of them failed. One of the major reasons of these failures is analysed based on the point of view of physics.

Numerical Study on Improvement of Storage Environment of Igloo-Shaped Magazine Using Forced Ventilation (강제환기를 적용한 이글루형 탄약고 저장환경 개선에 관한 수치적 연구)

  • Yoon, Hae-Deun;Kim, Seong Hoon
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.24 no.1
    • /
    • pp.99-106
    • /
    • 2021
  • This study explores the improvement of storage environment of igloo-shaped magazine using forced ventilation. Conjugate heat transfer analysis of forced convection and conduction are performed to calculate the flow, temperature, and relative humidity field in igloo-shaped magazine. Through the conjugate heat transfer analysis, the effects of inlet vent, volume flow rates of jet, and jet angles on the condensation and relative humidity are numerically investigated. The area of condensation in igloo-shaped magazine and relative humidity at the surface of ammunitions are then calculated.

Design consideration and explosion safety of underground ammunition storage facilities (지하탄약고의 설계요소 및 폭발안전 연구)

  • Kim, Oon-Young;Lee, Myung-Jae;Kim, Min-Seok;Kim, Joon-Youp;Joo, Hyo-Joon
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.5 no.1
    • /
    • pp.55-70
    • /
    • 2003
  • Ammunition magazine, which is installed on the ground, has difficulty in protecting from the external attack, and accidental explosion should cause great damage to the life and property. For these reasons, it is needed to develop underground magazine that it has the advantages of safety, security and maintenance. This paper introduce the design case for blasting facilities, which should resist blasting pressure, as well as layout of underground magazine, which takes a safety for explosion and a working space of loading/unloading machine into consideration. On the layout, in case of ${\bigcirc}{\bigcirc}$ underground magazine, put three storage chambers in position almost parallel with principle stress direction, where less effected on discontinuity and hard rock area. Also, secured safe distance according to safety criteria of the Defense Ministry, and verified suitable layout by trace simulation for loading/unloading machine on working stage. Blasting design was performed on evaluation of maximum blast pressure between donar and acceptor chambers, and design condition for blast door, valve, etc. Diminution facilities against explosion, such as thrust block or debris trap, determined its size after plan in accordance with blasting criteria and calculation by structural analysis.

  • PDF

A Study on the Safety Distance of Underground Structures in Asepct of Ground Vibration Velocity due to Explosions (지중 구조물의 지반 진동 안전거리 설정에 관한 현장적용연구)

  • Park, Sangjin;Kang, Jiwon;Park, Young Jun
    • Korean Journal of Construction Engineering and Management
    • /
    • v.17 no.4
    • /
    • pp.87-94
    • /
    • 2016
  • The necessity to consider stability of underground structures constructed below or adjacent ammunition depots has been increased since the expansion of urban area and construction of infrastructure. However, there are a few studies on influence of accidental explosion on underground structures. In this study, the process of assessing the stability of underground structures is suggested and its applicability is verified through the case study. AUTODYN and SPACECLAIM are used to execute the structure and geotechnical modelling, and explosion effect is simulated and vibration velocities are calculated. According to the result of this case study, it is concluded that underground structure constructed 70m below ground might be rarely influenced by the simulated explosion. The process used in this study could be used to design the underground ammunition complex and analyse the stability of underground facilities being influenced by periodical vibration.