An Investigation on the Behavior of Fracture Mechanics as the Type of Mode I at Specimen Bonded with Tapered Carbon Fiber Reinforced Plastic (경사진 CFRP로 접합된 시험편에서의 Mode 1 형 파괴역학적 거동에 관한 연구)

  • Lee, Jung-Ho;Cho, Jae-Ung;Cheon, Seong Sik
    • Composites Research
    • /
    • v.29 no.2
    • /
    • pp.85-89
    • /
    • 2016
  • This paper aims at estimating the fracture behavior at the bonded part of composite material. CFRP is manufactured as the type of TDCB. The static analysis of Mode 1 due to the configuartion factor of m is carried out. Four kinds of specimens have the configuartion factor(m) of 2, 2.5, 3 and 3.5. As the study result, the displacements at specimens are shown to be similar each other in these four cases. At m of 3.5, the reaction force becomes highest as 412 N and is shown to be improved as much as 14% by comparing m of 2. The data on defection of the bonded interface and reaction force are thought to be contributed to the structural design of CFRP and the safe design.

Thermophysical Properties of 4D Carbon/Carbon Composites with Preform Architectures (프리폼 구조에 따른 4방향성 탄소/탄소 복합재의 열물리적 특성)

  • Kim, Zeong-Baek;Lee, Ki-Woong;Park, Jong-Min;Joo, Hyeok-Jong
    • Applied Chemistry for Engineering
    • /
    • v.18 no.6
    • /
    • pp.580-586
    • /
    • 2007
  • In this study, 4 directional carbon/carbon composites with different preform architectures were manufactured and their thermophysical properties are studied. Carbon fiber preforms are fabricated with fiber bundles using four different spaces. The density of the fabricated preforms were increased through pressure impregnation and carbonizing process. The increased density of the composites was graphitized at $2300^{\circ}C$. Microstructures of these composite were observed under scanning electron microscope. This was to understand the effect the preform architectures has on the thermophysical properties of carbon/carbon composites. Also, the behavior of thermal conduction and heat expansion was investigated and studied in association with the factors of the reinforced direction of fibers and unit cell of preforms.

A Study on Flexural Behavior of Externally Reinforced R.C. Beam with Carbon Fiber Sheet : In Case of Constructional Deficiencies (탄소섬유시트로 보강된 철근콘크리트 보의 시공불량시 휨 거동에 관한 연구)

  • Park, Hyun-Jung;Lee, Hong-Ju;Park, Sung-Soo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.6 no.1
    • /
    • pp.95-102
    • /
    • 2002
  • The flexural behavior of the reinforced concrete (RC) structure upgraded by external reinforcements was examined in this study. It is well known that the incorporation of carbon fiber sheet (CFS) with concrete is one of the most effective ways to strengthen the RC structure. Complete bonding is required between CFS and concrete in order to make the RC structure provide its full function until the time the Re structures serve. Many studies have reported that construction deficiencies have caused the debonding of the CFS from concrete before the RC structure with CFS reaches its ultimate capacity. This research took a systematic look at the failure mechanism, macroscopic load-deformation characteristics, the maximum load applied, and maximum bending moment when construction deficiencies exist. The results of the experiment conducted were compared with theoretically derived values. In the future, the results of this investigation will help minimize the factors of construction deficiencies, which may occur when CFS is used to reinforce a RC structure. The experiment was manipulated with steel reinforcement ratio and piles of CFS on a total of 14 beams ($20cm{\times}30cm{\times}240cm$). The results showed that internal moment capacity increased even when construction deficiencies existed. However, RC structures with CFS in the field still contain a considerable level of potential risks.

Comparison of Mechanical Properties on Helical/Hoop Hybrid Wound HNT Reinforced CFRP Pipe with Water Absorption Behavior (CFRP 파이프의 와인딩 적층 패턴 설계 및 HNT 나노입자 보강에 따른 수 환경에서의 기계적 물성 평가)

  • Choi, Ji-Su;Park, Soo-Jeong;Kim, Yun-Hae
    • Composites Research
    • /
    • v.34 no.3
    • /
    • pp.174-179
    • /
    • 2021
  • Currently, fluid transfer steel pipes take a lot of time and expense to maintain all facilities due to new construction and painting or corrosion and aging. Therefore, this study was conducted for designing a CFRP pipe structure with high corrosion resistance and chemical resistance as a substitute for steel pipes. The helical/hoop pattern was cross-laminated to improve durability, and HNT was added to suppress the moisture absorption phenomenon of the epoxy. The HNT/CFRP pipe was manufactured by a filament winding process, and performed a mechanical property test, and a moisture absorption test in distilled water at 70℃. As a result, the highest bending strength was obtained when the hoop pattern was laminated with a thickness equivalent to 0.6% of the pipe. The 0.5 wt% HNT specimen had the highest moisture absorption resistance. Also, the delamination phenomenon at the interlayer interface was delayed, resulting in the lowest strength reduction rate.

Earthquake Response Analysis of a RC Bridge Including the Effect of Repair/retrofitting (보수/보강 효과를 고려한 철근콘크리트교량의 내진응답해석)

  • Lee, Do Hyung;Cho, Kyu Sang;Jeon, Jeong Moon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.4A
    • /
    • pp.611-622
    • /
    • 2008
  • Nonlinear analyses have been carried out for both bridge piers and a bridge structure being repaired using a repair element in order to assess the post-repair seismic response of such structures. For this purpose, a simplified CFRP stress-strain model has been proposed. The analytical predictions incorporating the current developments correlate reasonably well with experimental results in terms of strength and stiffness. In addition, nonlinear dynamaic analyses have also been conducted for a bridge structure in terms of the created multiple earthquake sets to evaluate the effect of pier repair on the response of a whole bridge structure. In these analyses, potential plastic hinge zones of piers are virtually repaired by CFRP and steel jacketing. Comparative results prove the virtual necessity of performing nonlinear post-repair analyses under multiple earthquakes, particularly when the post-repair response features are required. In all, the present approaches are expected to provide salient information regarding a healthy seismic repair intervention of a damaged strcuture.

Comparative Analysis of Biomechanical Behaviors on Lumbar with Titanium and Carbon Fiber Reinforced PEEK Connecting Rods for Fusion Surgery (티타늄과 탄소 섬유 강화 PEEK로 구성된 요추 유합술용 연결봉의 의공학적 영향에 대한 비교 분석)

  • Seo, Hye-Sung;Kang, Hae-Seong;Chun, Houng-Jae
    • Composites Research
    • /
    • v.34 no.3
    • /
    • pp.186-191
    • /
    • 2021
  • The lumbar spinal fusion is a treatment performed to restore the stability of the degenerated lumbar. In this study, the intervertebral discs between two or more segments are removed and a bone graft is inserted to harden the segments. The pedicle screw system is inserted to vertebral bodies to fix two or more segments so that they can be firmly fused. In this study, a total of 7 patient-specific lumbar finite element models were created and pedicle screw systems were installed. The connecting rods made of titanium and CFR-PEEK was inserted to the generated models. Finite element analysis was conducted for four representative spine behaviors and statistical analysis was performed to investigate the biomechanical effects by the material properties of connecting rods. The intradiscal pressure of adjacent segments and the range of motion of the joints of each segment were investigated. In the subjects who used CFR-PEEK instead of Ti for connecting rods, the intradiscal pressure of adjacent segments tend to decrease and the range of motion of each segment tend to increase. However, no statistically significant difference in tendency was observed under all loading conditions.