• Title/Summary/Keyword: 탄성파 진폭

Search Result 112, Processing Time 0.023 seconds

Polarization Filters Using the Multicomponent Complex Trace Analysis (다성분 복소트레이스를 이용한 분극필터)

  • Kim, Ki-Young;Lee, So-Young
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.89-94
    • /
    • 2006
  • In order to increase the signal-to-noise ratio in multi-component seismic data, we developed new polarization filters based on the method of multicomponent complex trace analysis. Unlike the previous polarization filters, the present filters separately compute linear and elliptic components at each time sample using amplitude ratio of horizontal and vertical components of body waves and ellipticity of Rayleigh waves. The polarization filters work ideally even with low S/N data. Application of the filters to both synthetic and real seismic data shows that Rayleigh waves of elliptic motions are effectively eliminated and both P and S waves of linear motions are well separated each other.

  • PDF

Effect of Airgun Intervals on marine Seismic Acquisition (탄성파 탐사에서 건 간격이 미치는 영향)

  • 유해수
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1998.06c
    • /
    • pp.483-486
    • /
    • 1998
  • 한국해양연구소 온누리호에 장착된 에어건 배열에서 건 간격에 따른 빔 패턴 변화를 확인하였으며 남극해역에서 획득된 탐사자료와 비교하였다. 컴퓨터 모의과정과 배열 이론을 이용하여 신호진폭 및 빔 폭 변화 등을 시간 및 주파수 영역에서 분석하였다. 154 Hz에서 송이배열 (cluster array) 및 폭 배열 (wide array)의 빔 폭 변화는 배열 형태보다는 건 간격에 큰 영향을 받고 있어 배열 형태가 달라도 빔 폭은 서로 유사하게 변한다. 건 간격이 클수록 송이배열이 90$^{\circ}$의 빔 패턴에서 주엽 (mainlobe)이 최대치가 되는 것과는 달리 폭배열은 0$^{\circ}$에서 최대치를 나타내며 부엽 (sidelobe)은 건 간격과 무관하게 나타난다. 두 배열의 선형간섭이 점차 줄어드는 건 간격은 2.43 m이다. 남극해 탐사자료는 건 간격이 증가함에 따라 주신호 진폭은 약하게 기포는 강하게 증가한다. 이러한 결과는 빔 패턴 변화에서도 마찬가지로 나타나는데 건 간격이 클수록 주엽의 빔 폭이 점차 좁아져 강한 빔 패턴을 나타냄으로서 남극 탐사자료와 서로 잘 일치한다.

  • PDF

Elastic Behavior of Contact Lense(I) : Effect of Vibration (콘택트 렌즈의 탄성에 관한 연구(I) : 진동에 의한 영향)

  • Kim, Dase-Soo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.4 no.2
    • /
    • pp.1-16
    • /
    • 1999
  • Differential equations and its numerical solution program using Turbo-C were formulated to describe the radical distribution and average displacement amplitude of vibrating dehydrated contact lens(HEMA) driven by sinusoidal or rectangular pressure. The natural resonant frequency of the lens diaphram(thickness 0.08mm, diameter 14mm, curvature radius 8mm) was measured to be 5730 Hz from the extrapolation of frequency vs addedmass to the diaphram curve. The Young's modulus of the lens was measured to be $4{\times}10^9$ Pa with altering the original shape. The effect of parameters such as thickness, effective radius, damping coeff., amplitude of driving pressure on the vibration characteristics was illustrated by the computer simulation of the derived program. When the frequency of driving pressure coincides with the integral multiple of fundamental resonance frequency of the lens the wave pattern changes from arc to bell-shape along the radial position of the diaphram. If this happens to the contact lens on the cornea in vivo, it might create the feel of pull of the lens due to the increased rise of central part of the lens.

  • PDF

Assessment of Degradation by Corrosion Fatigue of TMCP Steel using a Backward Radiated Ultrasound (후방복사 초음파를 이용한 TMCP강의 부식피로 손상평가)

  • Kim, Y.H.;Bae, D.H.;Park, J.H.;Yu, H.J.;Kwon, S.D.;Song, S.J.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.23 no.4
    • /
    • pp.349-355
    • /
    • 2003
  • Material degradation due to corrosion fatigue was evaluated nondestructively using backward radiated Rayleigh surface wave. h corrosion fatigue test was carried out for the specimens made of thermo-mechanically controlled process steel in 3.5wt.% NaCl solution at $25^{\circ}C$. The backward radiation profile, which is the amplitude variation of backward radiated ultrasound according to the incident angle, of the specimens were measured in water at room temperature after the corrosion fatigue test. The velocity of Rayleigh surface wave, determined from the incident angle at which the profile of the backward radiated ultrasound became maximum, decreased for the specimen that had the large number of cycles to failure in the corrosion fatigue test. This fact implies that the corrosion degradation occurred at specimen surface in this specific test is dominantly dependant on the me exposed to corrosion environment. The result observed in the present work demonstrates the high potential of backward radiated Rayleigh surface wave as a tool for nondestructive evaluation of corrosion degradation of aged materials.

Influence of Wall Motion and Impedance Phase Angle on the Wall Shear Stress in an Elastic Blood Vessel Under Oscillatory Flow Conditions (맥동유동하에 있는 탄성혈관에서 벽면운동과 임피던스 페이즈앵글이 벽면전단응력에 미치는 영향)

  • 최주환;이종선;김찬중
    • Journal of Biomedical Engineering Research
    • /
    • v.21 no.4
    • /
    • pp.363-372
    • /
    • 2000
  • The present study investigated flow dynamics of a straight elastic blood vessel under sinusoidal flow conditions in order to understand influence of wall motion and impedance phase angle(time delay between pressure and flow waveforms) on wall shear stress distribution using computational fluid dynamics. For the straight elastic tube model considered in the our method of computation. The results showed that wall motion induced additional terms in the axial velocity profile and the pressure gradient. These additional terms due to wall motion reduced the amplitude of wall shear stress and also changed the mean wall shear stress. Te trend of the changes was very different depending on the impedance phase angle. As the wall shear stress increased. As the phase angle was reduced from 0$^{\circ}$to -90$^{\circ}$for ${\pm}$4% wall motion case, the mean wall shear stress decreased by 10.5% and the amplitude of wasll shear stress increased by 17.5%. Therefore, for hypertensive patients vulnerable state to atherosclerosis according to low and oscillatory shear stress theory.

  • PDF

Gas Hydrate Occurrence in the Southwestern Slope of the Ulleung Basin, East Sea, Inferred from Seismic Evidence (동해 울릉분지 남서 사면지역에서 탄성파 특징으로부터 유추한 가스 수화물의 존재 가능성)

  • Hong, Jong-Kuk;Yoo, Hai-Soo;Jou, Hyeong-Tae;Han, Sang-Joon;Choi, Dong-Lim
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.6 no.4
    • /
    • pp.242-248
    • /
    • 2001
  • A high resolution Chirp seismic profile and a multichannel seismic reflection profile were analysed to study the possibility of gas hydrate presence in the southwestern upper slope of the Ulleung Basin. The Chirp profile shows acoustic turbidity, acoustic void, and pockmarks, suggesting the presence of shallow gas in the sediments .Slope failures appear to have occurred in association with decomposition of gas hydrated sediments. A bottom-simulating reflector (BSR) is seen in subbottom depths of 60 to 110 m below the seafloor at water depths of 750 to 1130 m. The sediments above BSR are characterized by acoustic blanking probably due to amplitude reduction caused by a mixture of gas hydrate with sediments. The interval velocity above the BSR is 1,650 m/sec and it drops abruptly to 1,080 m/sec below the BSR. The sediment column between seafloor and the BSR thins with increasing water depth, which is very closely related to increasing geothermal gradient with increasing water depth in the Ulleung Basin.

  • PDF

Directional Characteristics of Sleeve-gun Arrays in Marine Seismic Survey (해양 탄성파 탐사에서 슬리브건 배열의 방향 특성)

  • Yoo, Hai-Soo;Yang, Sung-Jin
    • The Journal of the Acoustical Society of Korea
    • /
    • v.15 no.1
    • /
    • pp.71-80
    • /
    • 1996
  • Characteristics of sleeve-gun arrays installed on the R/V Onnuri were analyzed and compared with survey data. In the case of cluster array, the beam width in the frequency range up to 814Hz is constant as $179.5^{\circ}$, and rapidly narrows in the frequency range of 814-1631Hz. However, in the case of long and wide arrays, as the frequency increases, the beamwidth decreases. The optimal frequency is 69Hz. the main lobe of vertical inclination has its maximum amplitude at phase angle $0^{\circ}$. The optimal frequency of cluster array which produces little side lobe is less than 1631Hz, and those of long and wide arrays are less than 108Hz. As a result, the cluster array produces a good source for high-resolution seismic survey, while the long and wide arrays are suitable for the survey of deep structures. The final high-resolution seismic section with cluster array was compared with that of long and wide arrays.

  • PDF

Monitoring and detecting $CO_2$ injected into water-saturated sandstone with joint seismic and resistivity measurements (탄성파 및 비저항 동시측정에 의한 수포화 암석시료에 주입된 $CO_2$ 모니터링 및 탐지)

  • Kim, Jong-Wook;Matsuoka, Toshifumi;Xue, Ziqiu
    • Geophysics and Geophysical Exploration
    • /
    • v.14 no.1
    • /
    • pp.58-68
    • /
    • 2011
  • As part of basic studies of monitoring carbon dioxide ($CO_2$) storage using electrical and seismic surveys, laboratory experiments have been conducted to measure resistivity and P-wave velocity changes due to the injection of $CO_2$ into water-saturated sandstone. The rock sample used is a cylinder of Berea sandstone. $CO_2$ was injected under supercritical conditions (10 MPa, $40^{\circ}C$). The experimental results show that resistivity increases monotonously throughout the injection period, while P-wave velocity and amplitude decrease drastically due to the supercritical $CO_2$ injection. A reconstructed P-wave velocity tomogram clearly images $CO_2$ migration in the sandstone sample. Both resistivity and seismic velocity are useful for monitoring $CO_2$ behaviour. P-wave velocity, however, is less sensitive than resistivity when the $CO_2$ saturation is greater than ~20%. The result indicates that the saturation estimation from resistivity can effectively complement the difficulty of $CO_2$ saturation estimations from seismic velocity variations. By combining resistivity and seismic velocity we were able to estimate $CO_2$ saturation distribution and the injected $CO_2$ behaviour in our sample.

Swell Noise Attenuation Using a Cascade of F-X Filter and Median Filter (F-X 필터와 중앙값 필터를 연속적으로 사용한 파랑잡음 제거)

  • Kim, Sookwan;Hong, Jong Kuk
    • Geophysics and Geophysical Exploration
    • /
    • v.15 no.4
    • /
    • pp.199-208
    • /
    • 2012
  • High-amplitude swell noises (HASN) are very difficult to eliminate from the marine seismic data. In this paper, we applied F-X filter and median filter in order to suppress HASN. Test data have been acquired on the northern offshore of the South Shetland Islands in December, 2010. Parts of data have been contaminated by HASN caused by bad weather during the cruise. We applied F-X filter and median filter to test data with HASN. After F-X filtering, most of non-coherent noises and small-amplitude swell noises are eliminated effectively but HASN are still remained significantly. With median filter, HASN was suppressed better than F-X filter, however some of non-coherent noises are still remains. We applied a cascade of two filters and results show HASN and non-coherent noises are suppressed effectively. After the cascade of two filtering, it is possible to define reflection layers clearly on the velocity spectrum and to produce better stacked section with a good signal-to-noise ratio.

Swell Effect Correction for the High-resolution Marine Seismic Data (고해상 해저 탄성파 탐사자료에 대한 너울영향 보정)

  • Lee, Ho-Young;Koo, Nam-Hyung;Kim, Wonsik;Kim, Byoung-Yeop;Cheong, Snons;Kim, Young-Jun
    • Geophysics and Geophysical Exploration
    • /
    • v.16 no.4
    • /
    • pp.240-249
    • /
    • 2013
  • The seismic data quality of marine geological and engineering survey deteriorates because of the sea swell. We often conduct a marine survey when the swell height is about 1 ~ 2 m. The swell effect correction is required to enhance the horizontal continuity of seismic data and satisfy the resolution less than 1 m. We applied the swell correction to the 8 channel high-resolution airgun seismic data and 3.5 kHz subbottom profiler (SBP) data. The correct sea bottom detection is important for the swell correction. To detect the sea bottom, we used maximum amplitude of seismic signal around the expected sea bottom, and picked the first increasing point larger than threshold value related with the maximum amplitude. To find sea bottom easily in the case of the low quality data, we transformed the input data to envelope data or the cross-correlated data using the sea bottom wavelet. We averaged the picked sea bottom depths and calculated the correction values. The maximum correction of the airgun data was about 0.8 m and the maximum correction of two kinds of 3.5 kHz SBP data was 0.5 m and 2.0 m respectively. We enhanced the continuity of the subsurface layer and produced the high quality seismic section using the proper methods of swell correction.