• Title/Summary/Keyword: 타디 보간법

Search Result 4, Processing Time 0.016 seconds

Stress Distribution of a Crane Hook by Photoelasticty Using 4-step Phase Shifting Method and finite Element Method (광탄성 4단계 위상 이동법과 유한요소법에 의한 크레인 훅의 응력분포 비교)

  • Baek, Tae-Hyun;Kim, Whan;Lee, Chun-Tae
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.1
    • /
    • pp.38-44
    • /
    • 2004
  • An experimental study for a crane hook was performed to investigate the stress distribution along a certain line where the maximum and minimum stresses to be developed. On this line, the isoclinic fringe and/or principal stress direction is constant. The crane hook was modeled into a 2-dimensional plate made of urethane rubber called 'Photoflex' The Photoflex is very sensitive to a load and has low photoelastic fringe constant. The Tardy compensation method with the fringe sharpening process and the 4-step phase shifting method, was used for the photoelastic technique. Experimental results by photoelasticity were compared with the calculated stresses from the simple curved beam theory and tile finite element analysis. Ail the results were close to each other.

인장시편 및 응력동결된 디스크의 프린지 상수 측정에 의한 다목적 편광기 성능시험

  • Baek, Tae-Hyun;Kim, Myung-Soo;Kim, Dong-Hyun;Lee, Chun-Tae;Kim, Hwan;Park, Tae-Geun
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.178-178
    • /
    • 2004
  • 본 연구에서는 폴리카보나이트의 재료로 만들어진 인장시편과 원형시편을 다목적 광탄성 측정기를 사용하여 프린지 차수를 측정한 후 프린지 상수를 도출하였다. 특히, 새로 개발된 다목적 광탄성기를 이용하여 지랫대 형식으로 프린지 차수를 측정하였고, 시편에 직접 응력을 가하는 방식의 직접(DIRECT) 실험법으로 프린지 차수를 측정하였다. 위와 같은 방식은 나타난 결과를 가지고 프린지 상수를 서로 비교할 수 있다는 장점이 있어 다목적 광탄성기에 대한 신뢰도를 얻을 수 있다 아울러 광탄성 4단계 위상 이동법에서는 주응력 방향, 즉 등경선이 일정한 선상에서는 연속적인 응력분포를 얻을 수 있다.(중략)

  • PDF

Measurement of Isochromatic Fringe Distribution of a TV Glass Panel by Use of Photoelastic 4-step Phase Shifting Method (광탄성 4단계 위상이동법을 이용한 TV유리패널의 등색프린지 분포측정)

  • Baek, Tae-Hyun;Kim, Myung-Soo;Cho, Seong-Ho
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.25 no.1
    • /
    • pp.1-8
    • /
    • 2005
  • This paper presents the experimental results measured by photoelastic 4-step phase shifting method for the isochromatic fringe distribution in a TV glass panel. In the conventional photoelastic method, the isochromatic fringe orders are measured manually point by point. The 4-step phase shifting method uses four images obtained from a circular polariscope by rotating the analyzer to $0^{\circ},\;45^{\circ},\;90^{\circ}$, and $135^{\circ}$. In order to use the 4-step phase shifting method, the elements of a polariscope should be aligned to isoclinic direction at a point and/or along a line where isochromatic fringe distribution is measured. Experimental results obtained from the 4-step phase shifting method are compared with those measured by the Senarmont compensation method. Both results are well agreed. Then, isochromatic fringe distributions in the TV glass panel that is heat-treated before and after are compared. Maximum and minimum isochromatic fringe orders in the TV glass panel with before- and after-heat treatment are changed approximately two times.

Simulation of Separating Isoclinics and Isochromatics from Photoelastic Fringes of a Disk using 8-step Phase Shifting Methodology (광탄성 프린지 위상이동법을 적용한 디스크의 등경 및 등색프린지 분리법에 관한 시뮬레이션)

  • Baek, Tae-Hyun;Kim, Myung-Soo;Cho, Sung-Ho
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.21 no.2
    • /
    • pp.189-196
    • /
    • 2001
  • Photoelasticity is one of the most widely used methods for whole field stress analysis. In photoelasticity, the difference and the directions of the principal stresses we given isochromatic and isoclinic fringe patterns. Conventionally, principal stress directions are measured manually by relating the polarizer and analyzer of a plane polariscope at the same time. This is known to be the Tardy compensation method. This measurement can be very tedious and time consuming in whole field analysis. It is not possible to separate isoclincs from photoelastic fringes by conventional photoelastic technique. In this study, photoelastic theory is represented by Jones matrices and 4-steps and 8-steps phase shifting methods are described A feasibility study using computer simulation is done to separate isoclincs and isochomatics from photoelastic fringes of a circular disk under diametrical compression. Fringe patterns of the disk are generated using stress optic law. The magnitudes of isoclincs and isochromatics obtained from 8-step phase shifting method are compared with those of theories. From computer simulation, it is verified to separate isoclincs and isochomatics from photoelastic fringes.

  • PDF