• Title/Summary/Keyword: 타격평가

Search Result 90, Processing Time 0.028 seconds

Evaluation Model for the Stability of the Diagnostic Information System Incorporating the Quantitative Evaluation (정량적 평가를 도입한 정보시스템 안정성 진단 평가 모델)

  • Im, Hyeong-Do;Park, Dea-woo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.05a
    • /
    • pp.313-316
    • /
    • 2016
  • Highly probable cause of the current turmoil critical national infrastructure and private enterprise information systems failures or national event of an accident, it is inevitable huge hit in corporate business as well as a significant impact on the national benefit. This is a trend subject to the stability of the national management information system has a significant impact on people and society, such as banking, telecommunications, transport and energy, which can be extended into a private institution. However, public and private ICT business through the development of Information system Audit or CMMI(Capability Maturity Model Integration) certification check the quality of the target system, but quality check on the reliability of the information system operations after construction is either not promoting met for some safety test results a situation that does not enabled by insufficient. By preventing the disorder or an accident of this study, the diagnostic reliability information systems through inspection and evaluation system development of information systems being established, and to minimize service confusion and study ways to ensure customer - oriented service.

  • PDF

A Study on Evaluation Criteria for M&S Analysis of Command and Control Effectiveness in Joint Operations (합동작전 지휘통제 효과도 모의분석을 위한 평가기준 연구)

  • Sohn, Young-Hwan;Kim, Weon-Bae
    • Journal of the Korea Society for Simulation
    • /
    • v.20 no.4
    • /
    • pp.167-175
    • /
    • 2011
  • Concerning the effectiveness of command and control is increasing worldwide as future warfare is changing into Network Centric Warfare (NCW). Unlike the old attrition warfare that depends mainly on mobility and strike assets, the modern warfare is based on information and network which regards acquisition and circulation of information as important. Therefore, there's no room for rediscussion that C4ISR (Command, Control, Communications, Computers, Intelligence, Surveillance and Reconnaissance) system will play an important role in warfare. In spite of this fact, there isn't any way to explain clearly how to measure the effectiveness of command and control system in a battle and to reflect it systematically in a system effectiveness. In this study, we examined NCO-CF (Network Centric Operations-Conceptual Framework), developed by the Department of Defense (DOD), which can conceptually explain the increment of effectiveness of C4ISR system that is the basis of NCO. And we suggested methodology based on NCO-CF to establish the evaluation criteria for M&S analysis of command and control effectiveness. As a case study we derived the evaluation criteria for the command and control system in joint operations by applying the suggested methodology.

Comprehensive evaluation of baseball player's offensive ability by use of simulation (시뮬레이션을 통한 프로야구 타자들의 공격능력의 종합적인 평가)

  • Kim, Nam Ki;Kim, Sun Ho
    • Journal of the Korean Data and Information Science Society
    • /
    • v.26 no.4
    • /
    • pp.865-874
    • /
    • 2015
  • This research is to comprehensively evaluate offensive abilities of baseball players who are expected to produce as many runs as possible by their hitting and running. To this end, we establish a simulation program to obtain the so-called scoring index of an individual player. The scoring index of a player is defined as an expected number of runs scored by an imaginary team that is composed of nine copies of the player. As a simulation input, we use 2014 season data of Korean pro-baseball. As a result, we present the scoring indices of top 10 players, 9 Korean pro-baseball teams, and overall 2014 season. The scoring index can serve as a comprehensive evaluation of offensive ability of a player or a team, selection of players for a (national) team or for a starting line-up, estimation of player's worth, and so on.

Evaluation of Effects on Impact Resonance Test for Determining Modulus of Asphalt Concrete (아스팔트 콘크리트 탄성계수 결정을 위한 충격공진시험 영향요소 평가)

  • Kweon, Gi-Chul;Lee, Jae-Hoan
    • International Journal of Highway Engineering
    • /
    • v.9 no.2 s.32
    • /
    • pp.89-99
    • /
    • 2007
  • The stiffness of the asphalt concrete is represented by the complex modulus $E^*$, which is very important properties in the mechanistic design of flexible pavement system. The moduli of asphalt concrete were generally determined by dynamic modulus test. However, the dynamic modulus testing method is too complex, expensive, and time consuming to be applicable on a production basis. The IR(Impact Resonance) method has been shown to be a truly simple nondestructive testing method which produces very repetitive, consistent results. The major object of this study was to estimate of the effects on IR tests for determining modulus of asphalt concrete including impact position, specimen support condition, impact steel ball size and sampling rate. The variations of IR test results with various testing conditions are within ${\pm}2.7%$.

  • PDF

Effective power for interrill erosion by rainfall-induced sheet flow (강우유발 면상흐름에 의한 세류간 침식에 대한 유효동력)

  • Shin, Seung Sook;Park, Sang Deog
    • Journal of Korea Water Resources Association
    • /
    • v.51 no.8
    • /
    • pp.665-676
    • /
    • 2018
  • Interrill erosion on a hillslope results from the combined action of the detachment of soil particles by raindrop impact and the sediment transport of surface runoff. This study newly defined the rainfall power which detaches soil particles and the sheet-flow power contributed to sediment transport in terms of energy expenditure rate of soil erosion and presented the effective power equation for interrill erosion by rainfall-induced sheet flow. The rainfall and sheet-flow power was evaluated by factors related with rainfall, slope, and runoff and coefficients of the power equation were analyzed based on references. Futhermore it was confirmed that the relative scales between the rainfall power and the sheet-flow power according to rainfall intensity reflect on the hydrological response and physical process of interrill erosion. From application of the field data for surface runoff and soil erosion it was verified that the rainfall and sheet-flow power is an appropriate equation to estimate a interrill erosion.

Safety Evaluation of a Shipping Capsule for Special Form Radioisotope (특수형 방사성 동위원소 운반캡슐의 안전성 평가)

  • Lee, Ju-Chan;Seo, Ki-Seog;Ku, Jeong-Hoe;Bang, Kyoung-Sik;Han, Hyon-Soo;Park, Seong-Won
    • Journal of Radiation Protection and Research
    • /
    • v.26 no.1
    • /
    • pp.35-43
    • /
    • 2001
  • All of sealing capsules to transport a special form radioactive material should be designed and fabricated in accordance with the design criteria prescribed in IAEA standards and domestic regulations. The objective of this study is to demonstrate the safety of a shipping capsule for $^{192}Ir$ special form radioisotope which produced in the HANARO. The safety tests were carried out for the impact, percussion, bending and heat test conditions. And leakage tests were carried out before and after the each test. Also, the safety analyses wert performed using computer codes in order to verify the test results. The capsule showed slight scratches and deformation, and maintained its structural and thermal integrities in all tests without any severe damage or melting. It also met the allowable limits of leakage rate after each test. Therefore, it has been verified that the capsule was designed and fabricated to meet all requirements for the special form.

  • PDF

Integrity evaluation of grouting in umbrella arch methods by using guided ultrasonic waves (유도초음파를 이용한 강관보강다단 그라우팅의 건전도 평가)

  • Hong, Young-Ho;Yu, Jung-Doung;Byun, Yong-Hoon;Jang, Hyun-Ick;You, Byung-Chul;Lee, Jong-Sub
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.15 no.3
    • /
    • pp.187-199
    • /
    • 2013
  • Umbrella arch method (UAM) used for improving the stability of the tunnel ground condition has been widely applied in the tunnel construction projects due to the advantage of obtaining both reinforcement and waterproof. The purpose of this study is to develop the evaluation technique of the integrity of bore-hole in UAM by using a non-destructive test and to evaluate the possibility of being applied to the field. In order to investigate the variations of frequency depending on grouted length, the specimens with different grouted ratios are made in the two constraint conditions (free boundary condition and embedded condition). The hammer impact reflection method in which excitation and reception occur simultaneously at the head of pipe was used. The guided waves generated by hitting a pipe with a hammer were reflected at the tip and returned to the head, and the signals were received by an acoustic emission (AE) sensor installed at the head. For the laboratory experiments, the specimens were prepared with different grouted ratios (25 %, 50 %, 75 %, 100 %). In addition, field tests were performed for the application of the evaluation technique. Fast Fourier transform and wavelet transform were applied to analyze the measured waves. The experimental studies show that grouted ratio has little effects on the velocities of guided waves. Main frequencies of reflected waves tend to decrease with an increase in the grouted length in the time-frequency domain. This study suggests that the non-destructive tests using guided ultrasonic waves be effective to evaluate the bore-hole integrity of the UAM in the field.

Evaluation Methode for LPMS Sensor of Nuclear Power Plant (원자력발전소 금속파편감시계통 센서 건전성 평가)

  • Jo, Sung-Han;Jung, Chang-Gyu;Kim, Hyoung-Gwan
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1816-1817
    • /
    • 2011
  • 원자력발전소의 금속파편감시계통(LPMS : Loose Parts Monitoring System)은 원자로냉각재계통 내부에 존재할 수 있는 금속 이물질과 구조물 이완부에 의한 충격신호를 조기에 검출하여 원자로 구조물 및 핵연료 손상, 제어봉 구동장애 등을 미연에 방지하여 발전소 안전운전을 담당하는 중요 감시설비이다. LPMS는 금속 이물질이나 구조물 이완부에 의한 충격신호를 검출하기 위해 충격파에 민감한 가속도계를 원자로냉각재계통 중 금속파편이 자연적으로 모일 수 있는 각 구역의 표면에 최소 2개 이상 설치되어 있다. 원전은 규제요건에 따라 설비의 건전성 확인을 위해 24시간, 7일, 31일, 91일 마다 각 1회의 설비 건전성 시험을 수행하며, 계획예방정비기간 중에는 가속도계 주변에서 강구나 스프링 타격기를 이용한 충격시험을 통해 설비 전체의 건전성을 확인하고 있다. 설비 건전성 확인을 위해 경상운전 중에 수행하는 설비 건전성 시험에는 설비 특성상 가속도계 및 전치증폭기의 건전성을 확인할 수 없다. 따라서 본 논문에서는 경상운전 중 가속도계와 전치증폭기의 건전성을 확인할 수 있는 기법을 제시하고자 한다.

  • PDF

A Design of SNS and Web Data Analysis System for Company Marketing Strategy (기업 마케팅 전략을 위한 SNS 및 Web 데이터 분석 시스템 설계)

  • Lee, ByungKwan;Jeong, EunHee;Jung, YiNa
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.6 no.4
    • /
    • pp.195-200
    • /
    • 2013
  • This paper proposes an SNS and Web Data Analytics System which can utilize a business marketing strategy by analyzing negative SNS and Web Data that can do great damage to a business image. It consists of the Data Collection Module collecting SNS and Web Data, the Hbase Module storing the collected data, the Data Analysis Module estimating and classifying the meaning of data after an semantic analysis of the collected data, and the PHS Module accomplishing an optimized Map Reduce by using SNS and Web data involved a Businesse. This paper can utilize this analysis result for a business marketing strategy by efficiently managing SNS and Web data with these modules.

ICS Security Risk Analysis Using Attack Tree (공격 트리를 이용한 산업 제어 시스템 보안 위험 분석)

  • Kim, Kyung-Ah;Lee, Dae-Sung;Kim, Kui-Nam
    • Convergence Security Journal
    • /
    • v.11 no.6
    • /
    • pp.53-58
    • /
    • 2011
  • There is increasing use of common commercial operation system and standard PCs to control industrial production systems, and cyber security threat for industrial facilities have emerged as a serious problem. Now these network connected ICS(Industrial Control Systems) stand vulnerable to the same threats that the enterprise information systems have faced and they are exposed to malicious attacks. In particular Stuxnet is a computer worm targeting a specific industrial control system, such as a gas pipeline or power plant and in theory, being able to cause physical damage. In this paper we present an overview of the general configuration and cyber security threats of a SCADA and investigate the attack tree analysis to identify and assess security vulnerabilities in SCADA for the purpose of response to cyber attacks in advance.