• Title/Summary/Keyword: 타각적굴절검사

Search Result 60, Processing Time 0.027 seconds

Research of Difference between the Refractive Powers by Autorefractometer and the Prescription using Phoropter (자동 굴절력계의 굴절력값과 포롭터를 이용한 처방값의 차이에 관한 연구)

  • Lee, Ju-Whan;Lee, Koo-Seok;Hong, Hyung-Ki
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.2
    • /
    • pp.231-237
    • /
    • 2014
  • Purpose: This study is research of the conditions which causes difference between the refractive power of the measurement of autorefractometer and the prescription using phoropter. Methods: Autorefractometer (SR-7000) and phoroptor (AV-9000) were used to measure 60 eyes of 30 participants who had no eye diseases and wore the corrective lens due to Ametropia. To prevent the dependence of the prescription value of the refractive power on the testers, two testers measured the refractive power of the eyes of the participants at the same measuring conditions. Results: Statistically, the prescribed values of the refractive power by two testers were not significantly different. Most of the prescribed values of the refractive power were smaller than the refractive power by autorefractometer In case of myopic eyes, the difference between refractive powers by the measurement of autorefractometer and the prescription using phoropter showed the trend of increase as the spherical refractive power became larger. The result was analyzed by the range of the different cylindrical refractive power for the myopic astigmatic eyes. In this case, the difference between refractive powers showed the trend of decrease as the cylindrical refractive power became larger. Conclusions: No difference between the prescribed value by two testers was observed. In case of myopic or myopic astigmatic eyes, the difference between refractive powers by autorefractometer and the prescription were measured to be approximately proportional to the refractive powers of ametropic eyes. As the this difference become larger for the participant who needs the lens of larger refractive power, additional caution is needed in the prescription of the refractive power of the corrective lens.

A Study of the Refractive Errors Comparition between City and Rural Elementary School Children (도시와 농촌지역 초등학생들의 굴절상태 비교에 관한 연구)

  • Kim, In Suk;Jang, Jung Un
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.21 no.2
    • /
    • pp.147-152
    • /
    • 2016
  • Purpose: This study was designed to be used as the basic visual function data after analyzing and investigating the refractive errors variation between city and rural elementary school children. Methods: To compare with city and rural areas, 2501 elementary school children who lived in Mokpo, Yeongam, Muan, Hampyeong were participated. Objective refraction, Subjective refraction and binocular function examinations were measured. Results: Mean of refractive error of rural areas was -1.47 D in 2012 years, -1.52 D in 2013 years, and -1.40 D in 2014 years. However average of refractive error was -1.65 D in 2012 years, -1.76 D in 2013 years and -1.75 D in 2014 years who lives in city areas. Average myopia was showed higher who lives in rural areas elementary school children than city areas elementary school children. There were significant differences between rural areas and city areas elementary school children (p = 0.03), but there were no significant differences by averagre hyperopia (p = 0.32). Average myopia was showed the tendency of increase as the students get older by analysis compare with rural and city areas elementary school children. It also showed high prevalence of myopia who lives in city areas elementary school children compare with lives in rural areas elementary school children. Conclusions: It is the very important to performed regular visual acuity test and correction during the largest refractive change period and it is necessary to have experts in the visual acuity test.

A Study on Usefulness of Static Retinoscopy in Eyes Opened for Hyperopic School-aged Children (양안개방상태에서 학령기 원시안 아동의 정적 검영법의 유용성 고찰)

  • Chun, Young-Yun;Park, Seong-Jong;Song, Woo-Jin;Lee, Seok-Ju
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.3
    • /
    • pp.293-298
    • /
    • 2012
  • Purpose: We compared static retinoscopy in eyes opened with cycloplegic refraction depending on the hyperopia for school-aged children. Methods: There were 59 eyes (30 patients) who were divided into 3 groups - the mild hyperopia (+0.25 D ~ +1.00 D), moderate hyperopia (+1.25 D ~ +2.00 D) and high hyperopia (+2.25 D or more). They all had 0.8 visual acuity or more. Autorefraction and retinoscopy were performed prior to cycloplegic refraction, and then copmared with manifest refraction and cycloplegic refraction. Results: Hyperopia measured with static retinoscopy tends to be measured higher than manifest refraction for school-aged children. Changes of spherical power was statistically significant (p < 0.001). Changes of astigmatism was not statistically significant (p > 0.05). Conclusions: The difference between cycloplegic refraction and static retinoscopy was not significant for hyperopic school-aged children. The use of retinoscopy was limited for opticians because of legal constraints. The usage of static retinoscopy in eyes opened for optician should be generalized under the conditions not using the cycloplegic.

Comparison between Subjective and Objective Angle of Deviation Using by Synoptophore and Prism Bar in Strabismus Patients (사시환자에서 Synoptophore와 Prism bar를 이용한 자각적 사시각과 타각적 사시각의 비교)

  • Wi, Dae-Gwang;Joo, Seok-Hee;Lee, Koon-Ja;Leem, Hyun-Sung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.1
    • /
    • pp.79-85
    • /
    • 2010
  • Purpose: We studied the relationship between subjective and objective deviating angle. Methods: Those who were diagnosed with strabismus among the patients who had no systemic diseases that fifty-one subjects (Male; 21, Female; 30) were measured between seven to sixty three years, evaluated to alternate cover test after AR/K (Canon RK-FI, Japan) and retinoscope measured refractive errors. Objective deviating angle was measured using prism bar; and subjective and objective deviating angles were measured and compared using the synoptophore. Results: For the correlation between subjective and objective deviating angles. The differences were $2.6{\pm}2.5{\Delta}$, between subjective deviating angle measured using synoptophore and objective deviating angles measured using synoptophore were $0.7{\pm}1.4{\Delta}$, the average with each other were $1.7{\pm}1.8{\Delta}$, with all the differences highly significant. Conclusions: We thought not only reduced angle of deviating errors and identified the significance in the correlation between subjective and objective deviating angles but also considered to be useful in determining deviating angle of patient with strabismus.

Clinical Features of Retinal Correspondence according to Refractive Errors and Deviation Angles (굴절이상과 편위각에 따른 망막대응의 임상적 고찰)

  • Wi, Dae-Gwang;Joo, Seok-Hee;Lee, Koon-Ja;Leem, Hyun-Sung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.4
    • /
    • pp.367-372
    • /
    • 2010
  • Purpose: The purpose of this study was to provide useful information for evaluating the sensory function of patients with strabismus by identifying the distribution of anomalous retinal correspondence (ARC) and normal retinal correspondence (NRC) by the degree of refractive errors and deviation angles. Methods: Objective refraction (AR/K, Cannon RK-F1, Japan) and subjective refraction tests were performed on 56 subjects (male: 26, female: 30) by an examiner; objective deviation angle was measured using synoptophore (OCULUS Synoptophore, Germany) with subject' eyes fully corrected for distance, and then subjective deviation angle was measured. Results: In all groups with refractive errors, the number of ARC was larger than that of NRC(67%). Particularly, it was largest in groups with myopia (71%), and in all groups, the number of UARC was larger than that of HARC. In groups with anisometropia, although the numbers of NRC and ARC were same, the number of UARC was larger than that of HARC as in other groups. In the distribution of NRC and ARC by deviation angle, the number of NRC was larger than that of ARC (46%) only at microstrabismus (0 ~ ${\pm}10{\triangle}$). Conclusions: Normal retinal correspondence were the most emmetropia in the retinal response were much higher than in the more hyperopia than the retinal correspondence were more myopia. In addition, the smaller the angle of retinal correspondence Normal over many, but overall, respectively.

The Evaluation of Reliability for Exam Distance of Visual Acuity (시력검사거리에 따른 원거리 시력검사 신뢰성 평가)

  • Chun, Young-Yun;Choi, Hyun-Soo;Park, Seong-Jong;Lee, Seok-Ju
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.1
    • /
    • pp.17-22
    • /
    • 2014
  • Purpose: We aimed to evaluate reliability of eye exam for visual acuity as a function of distance. Methods: There were 39 patients (78 eyes) who had visual acuity 1.0 or more at 5 meters. We measured refractive power of patients at each distances, 5 meters, 4 meters and 3 meters. Automatic chart (LCD-700, Hyeseong Optic. Co., Korea) used for visual acuity, skiascope (Beta 200, Heine, Germany) and auto refractometer (RK-5, Canon, Japan) used as for objective refraction. Accommodation was examined by minus lens addition methods, and Accommodative lag was examined by grid chart for reading distance. Results: Being compared to 3 meter test, Amount of corrected spherical refractive power decreased by $0.10{\pm}0.38$ D, astigmatism decreased by $0.05{\pm}0.10$ D, and axis of astigmatism rotated toward to temporal by $2.64{\pm}18.75$ degrees for right eyes, by $11.43{\pm}48.55$ degrees for left eyes in case of 5 meter test. Changes of corrected refraction and astigmatism were slightly correlated (r=-0.31, r=-0.29). Conclusions: Because corrected refraction power and amount of astigmatism decreased and axis of astigmatism tends to turn the temporal direction according to exam distance, examination distance of visual acuity should improved as to 5 meters.

Study on Development of Infrared Retinoscope (적외선 검영기의 개발에 관한 연구)

  • Lee, Ik-Han;Sung, A-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.1
    • /
    • pp.29-34
    • /
    • 2004
  • The aim of this thesis research is to develop equipment measuring refractive state in order to measure the general ocular function using PC-based Foucault Test(Knife Edge Test). The Image of light generated from the reflection of incident light in retina thru Knife Edge Test was photographed using a CCD camera. The resulting image was then analyzed to measure the size of pupil by measuring the diameter of reflected image. The reflection state was judged from the orientation of reflected image and the degree of abnormal reflection was confirmed by measuring the size of second image of reflection. The aberration value was calculated from the magnitude of spherical aberration obtained by comparing the brightness of second reflected image appeared in the opposite direction to the reflected image.

  • PDF

A Study of Research on Uncorrected Refractive Error in Elementary School Children in Mokpo (목포지역 초등학생들의 미교정안 현황에 관한 연구)

  • Kim, In Suk;Jang, Jung Un
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.3
    • /
    • pp.313-317
    • /
    • 2011
  • Purpose: This study was to assess prevalence of refractive errors and uncorrected refractive errors in elementary school children in Mokpo and uncorrected refractive errors were to be used as the basic data. Methods: Vision tests were conducted on 400 subjects of 1st~6th grades at 3 elementary schools in Mokpo city, and subjective, objective refraction test were also performed to survey uncorrected refractive errors. Results: The prevalence of myopia was 256, 64% of total subjects, Hyperopia was 21, 5.3%, astigmatism was 19, 4.8%. The prevalence of uncorrected refractive errors were increased as higher grade and more oculus dexter higher than oculus sinister. Conclusions: Vision impairment which need an accurate vision correction for elementary school students requires the regular examination and actively correction in order to protect the elementary school students for basic welfare.

The Study of Prevalence Rate of Refractive Error among the Primary Students in Jeollanamdo (전남지역 초등학생의 굴절이상 유병률에 관한 연구)

  • Jang, Jung Un;Park, Inn-Jee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.3
    • /
    • pp.311-318
    • /
    • 2015
  • Purpose: This study was designed to investigate the prevalence rate of refractive error with gender and age presenting visual acuity of primary student in Jeonnam. Methods: Subjective refraction, objective refraction and visual acuity test were examined on 735 primary school children who ages of 8~13 years lived in Jenman. Presenting visual acuity test was using Han's visual acuity chart and objective refraction was carried out using auto-refractometer. Results: The presenting visual acuity was 0.1 worse in the eye of 54(7.3%) students and 49(7.3%) of them wearing the glasses. The rate of the wearing glasses were 79.3% in 0.125~0.25 visual acuity, 64.2% in 0.3~0.5 visual acuity and 61.6% in 0.6~0.8 visual acuity. It was appeared that 269(36.6%) of them were emmetropia, 321(43.7%) of them were myopia and 56(7.6%) of them were hyperopia, and 89(12.1%) of them were astigmatism. The prevalence rate of myopia was the highest and followed by the prevalence rate of astigmatism. The low degree of myopia occupied the most and the medium degree of myopia showed the tendency of increase as the students get olds. The prevalence rate of the hyperopia showed the tendency of decrease as the students get olds. The prevalence rate of with the rule astigmatism were 50.6% students and against the rule astigmatism were 48.3% of students. Conclusions: The present study reveals the considerable prevalence rates, 466(63.4%) of included subjects, of refractive errors among primary students in Jeonnam province. The rate of the wearing glasses were 313(42.6%). The prevalence of myopia increases as the students get older. Therefore students of visual management is considered necessary through the visual acuity test and refractive examination.

Comparison of Accuracy for Autorefraction according to Measuring methods (측정방식에 따른 자동굴절검사의 정확도 비교)

  • Jeong, Youn Hong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.8
    • /
    • pp.353-359
    • /
    • 2018
  • In this study, the performance between subjective refraction and open-field/closed view autorefraction was estimated. We measured the refractive error of early adults aged 18 to 20 years who did not have eye disease. The differences between measurements obtained by subjective refraction and open-field autorefraction for SE, J0, and J45 were $-0.13{\pm}0.53D$ (p=0.17), $+0.33{\pm}0.68D$ (p=0.01), and $+0.13{\pm}0.68D$ (p=0.26), respectively, with only J0 differing significantly. The differences between the measurements of subjective refraction and closed-view autorefraction for SE, J0, and J45 were $-0.30{\pm}0.42D$ (p=0.00), $+0.30{\pm}0.71D$ (p=0.02), and $-0.02{\pm}0.63D$ (p=0.88), respectively, with only SE and J0 differing significantly. The coefficient of accuracy for SE, J0, and J45 components of open-field and closed-view autorefraction were 1.04, 1.33, and 1.34 and 0.83, 1.40, and 1.24, respectively. It is possible to predict the refractive error, which is necessary when deciding on subjective refraction, by measuring the objective refraction of open-field/closed view autorefractors.