• Title/Summary/Keyword: 크로마토그래피

Search Result 1,293, Processing Time 0.028 seconds

SMB 크로마토그래피를 이용한 loxoprofen racemate의 분리

  • Yun, Tae-Ho;Kim, In-Ho
    • 한국생물공학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.549-553
    • /
    • 2003
  • SMB(simulated moving bed) chromatography system has been developed to realize continuous separation and save solvent consumption for binary mixture such as chiral compounds in especial. The parameters of SMB chromatography system can be calculated from mass balance equations of true moving bed chromatography, and they are used in design of 6-column SMB chromatography. We can separate 1'R-25 and 1'S-2S enantiomers as a raffinate product in 95% of purity using assembled SMB chromatography system.

  • PDF

SMB 크로마토그래피를 이용한 광학이성질체의 분리

  • Yun, Tae-Ho;Park, Hui-Jun;Kim, In-Ho
    • 한국생물공학회:학술대회논문집
    • /
    • 2003.04a
    • /
    • pp.506-510
    • /
    • 2003
  • SMB(simulated moving bed) chromatography system has been developed to realize continuous separation and save solvent consumption for binary mixture in especial. The parameters of SMB chromatography system can be calculated from mass balance equations of true moving bed chromatography, and they are used in design of 6-column SMB chromatography. We can separate S-ketoprofen enantiomer as a raffinate product in 85% of purity and 0.3mg/ml using assembled SMB chromatography system.

  • PDF

Chromatographic Techniques for the Isolation and Purification of Metalloporphyrins from Crude Asphalts (크로마토그래피를 이용한 아스팔트로 부터 금속 포르피린의 분리및 정제)

  • Woo Ki Chae
    • Journal of the Korean Chemical Society
    • /
    • v.28 no.6
    • /
    • pp.393-398
    • /
    • 1984
  • Porphyrin-rich materials were obtained from some crude asphalts by gel permeation chromatography and silica gel chromatography. After extraction of each chromatographic fractions through alumina with pyridine, more concentrated metalloporphyrins were obtained. Demetallation of metalloporphyrins was possible without destroying porphyrin ring to provide different type of metal free porphyrins.

  • PDF

A Study on Capillary Column Ion Chromatography

  • 김호현;표동진
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2001.05a
    • /
    • pp.115-116
    • /
    • 2001
  • 본 연구에서는 이온 크로마토그래피로 환경오염물질들을 분석하고자 할때의 단전들을 해소하기 위하여 모세관 컬럼 이온 크로마토그래피를 개발하였다. 모세관 컬럼은 두가지 형태로 개발하였는데 하나는 packed capillary 컬럼이며 다른하나는 open tubular capillary 컬럼이다. 또한 위와 같이 모세관 컬럼을 개발하여 사용하게됨을써, 부수적으로 펌프, 시료주입기, 억압장치 그리고 전도도 셀 등을 모두 적은 부피를 다룰 수 있는 구조로 바꾸어 주었다. 따라서 본 연구의 결과로 미량환경오염 물질의 분석에 모세관 컬럼 이온크로마토그래피를 이용할 수 있는 가능성을 확인할 수 있었고, 나아가 이온 크로마토그래피의 소형화로 현장에서 직접 분리, 분석을 할 수 있으리라 기대된다.

  • PDF

Development of Miniaturized Automatic Chromatography System for validation Study of Chromatographic Resin lifetime (크로마토그래피 담체의 수멍을 검증하기 위한 자동화 미니 크로마토그래피 시스템 개발)

  • 박재하;서창우
    • KSBB Journal
    • /
    • v.17 no.4
    • /
    • pp.326-332
    • /
    • 2002
  • The quality of biopharmaceutical proteins is strongly affected by a manufacturing process employed to produce Et, and thus validation of the manufacturing bioprocess is a very important issue. Chromatography is probably the most widely used bioprocess unit operation for protein purification. In this study, a miniaturized automatic chromatography system was designed and constructed for scale-down studies for process chromatography validation. This system, named MiniValChrom, has the following features: automatic and repeated operation, flexible sequences and intervals among the steps, on-line and real-time monitoring and control, method files savings, etc. Using the MiniValChrom, we peformed a case study of an abbreviated experiment to estimate chromatographic resin lifetime. BSA (bovine serum albumin) and Cibacron Blue 3G-A were used as the model protein and the resin, respectively. The resin deterioration was evaluated by determining and monitoring the HETP and NTP values from the chromatograms every 5 cycles. It was observed that the HETP and the NTP values were changed by 9% after 15 cycles. The resin lifetime validation could be completed by repeating this experiment until the HETP value reached a predetermined value. The MiniValChrom's concept and the protocol suggested in this study can serve as a rapid and economical tool for the validation studies of bioprocess chromatography system.

Development of Miniaturized Automatic Chromatography System for Column Performance Validation : MiniValChrom

  • Park, Jae-Ha;Lee, Eun-Gyu
    • 한국생물공학회:학술대회논문집
    • /
    • 2000.11a
    • /
    • pp.147-150
    • /
    • 2000
  • Bioprocess chromatography is probably the most widely used unit operation in biopharmaceutics manufacturing. To obtain a good quality product reproducibly, the chromatography process validation should be performed carefully. We developed a miniaturized automatic chromatography system, MiniValChrom, for column performance validation.

  • PDF

Gel Permeation Chromatography of Douglas-fir(Pseudotsuga menziesii(Mirb.) Franco) Bark Condensed Tannins (미송(美松) 수피(樹皮)탄닌의 젤 침투 크로마토그래피)

  • Bae, Young-Soo
    • Journal of the Korean Wood Science and Technology
    • /
    • v.18 no.2
    • /
    • pp.16-24
    • /
    • 1990
  • 아세틸화(化) 고분자(高分子) 축합(縮合)탄닌의 젤침투 크로마토그래피 분석(分析)을 위해 일반적(一般的)으로 사용(使用)되고 있는 폴리스타이렌 표준물질(標準物質)은 부정확(不正確)한 교정(矯正)값을 준다. 한편 유도체화 하지않은 축합탄닌의 젤침투 크로마토그래피는 폴리스타이렌 디비닐벤젠 코폴리머 컬럼과 디메틸 포름아미드를 용매(溶媒)로 사용(使用)하여 매우 만족스럽게 분석(分析)될 수 있었다. 그 컬럼의 교정은 유도처리 되지않은 고분자(高分子) 축합(縮合)탄닌을 이용(利用)하여 수행되었으며 고분자 탄닌을 유도처리 할 필요가 없으므로 탄닌의 신속한 분자량(分子量) 결정(決定)이 가능하고 컬럼 크로마토그래피로 분리(分離)되어지는 탄닌을 연속적으로 분석(分析)할 수 있는 장점(長點)을 가진다.

  • PDF

단백질의 치환 크로마토그래피

  • 윤태호;김인호
    • Bioindustry News
    • /
    • v.13 no.2
    • /
    • pp.13-17
    • /
    • 2000
  • 새로운 분리공정으로써 크로마토그래피를 이용하고자 하는 노력들이 활발하게 진행되어지고 있는 가운데, 기존의 전통적인 크로마토그래피를 더욱 발전시킨 시도들이 행하여지고 있다. 여기에 부합하여 약 20여년 전부터 연구되기 시작한 Displacement ion-exchange chromatography는 현재 활발한 연구가 진행되어지고 있으며, 전형적인 preparative chromatography에 비해 많은 장점을 가지고 있다. Displcement ionexchange chromatography는 displacer를 사용하여, 고농도의 원료 물질을 효율적으로 단시간내에 처리할 수 있는 공정으로 기존의 preparative chromatography의 문제점이었던 꼬리끌기 현상과 희시현상을 대폭 감소시킬 수 있게 되었다. 따라서, displacement ion-exchange chromatography 공정에서의 가장 큰 과제인 비선형 등온선 영역에서의 거동과 분리공정 조작선의 결정 및 고성능의 displacer에 대한 연구가 요구되어지고 있으며, 본 총론에서는 이온교환 크로마토그래피 공정에서 displacement ion exchange chromatography를 이용한 단백질의 분리에 대하여 고찰하고자 한다.

  • PDF

Prediction of Organic Acid Chromatogram in High Performance Ion Chromatography (고성능 이온 크로마토그래피에서 유기산의 크로마토그램 예측 연구)

  • 원혜진;한선호;박양순;조기수;김인호
    • KSBB Journal
    • /
    • v.15 no.1
    • /
    • pp.60-65
    • /
    • 2000
  • In order to predict the chromatogram for organic acid in ion chromatography, Langmuir isotherm parameters were obtained by Retention Time Method (RTM) and moment method. Ion chromatography analysis for formic acid was performed and compared with theoretically predicted profiles under isocratic condition. Band profiles were estimated with the equilibrium-dispersive model of chromatography using a PDEsolver Macsyma . The relationship between the characteristics of chromatogram and the variable operating condition in chromatography such as the flow rate, ionic strength and injection volume was studied. Satisfactory agreement was observed between the experimental and the estimated chromatograms with parameters obtained form the moment method.

  • PDF

Enantiomer separation using a covalently immobilized chiral column derived from polysaccharide derivative by reversed phase liquid chromatography (역상 크로마토그래피에서 다당유도체로 공유결합된 키랄 컬럼을 이용한 거울상 이성질체의 광학분리)

  • Huang, Hu;Jin, Jing Yu;Baek, Chae-Sun;Lee, Wonjae
    • Analytical Science and Technology
    • /
    • v.22 no.2
    • /
    • pp.148-151
    • /
    • 2009
  • Enantiomer separation of N-fluorenylmethoxycarbonyl (FMOC) $\alpha$-amino acid was performed on covalently immobilized chiral column (Chiralpak IB) based on polysaccharide derivative as a chiral selector by reversed phase liquid chromatography. The effect of the reversed mobile phase on the chromatographic parameters of the enantioselectivities, resolution factors and retention times using covalently immobilized Chiralpak IB was shown. Also the enantiomer separation of N-FMOC $\alpha$-amino acid in the reversed and normal phase was compared and the results obtained in the former mobile phase were generally lower than those in the latter mobile phase.