• Title/Summary/Keyword: 크기분포

Search Result 4,065, Processing Time 0.037 seconds

The effect of Silano-pen on the shear bond strength of resin to feldspathic porcelain and zirconia (실라노 펜의 적용이 장석계 도재 및 지르코니아와 레진의 전단결합강도에 미치는 영향)

  • Shin, Myoung-Sik;Lee, Jeong-Yol;Kim, Min-Soo;Shin, Sang-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.1
    • /
    • pp.1-8
    • /
    • 2014
  • Purpose: The purpose of this study is to evaluate the effect of applying Silano-pen to feldspathic porcelain and zirconia on shear bond strength with composite resin. Materials and methods: Feldspathic porcelain and zirconia specimens were produced into 30 per each 2 mm thick and 12 mm in diameter and their surface was made smooth and even and then embedded in acrylic resin. The specimens were divided into each Group F (Feldspathic porcelain) and Group Z (Zirconia), (1) Hydrofluoric acid etching and silane (F1 & Z1), (2) Silano-pen and silane (F2 & Z2), (3) Hydrofluoric acid etching and Silano-pen, silane (F3 & Z3). After surface conditioning, substrate surfaces of the specimen were examined by SEM. Composite resin cylinders (2 mm high, 3 mm in diameter)were bonded to specimen and shear bond strength between ceramic and composite resin was measured by using universal testing machine. The measured values were statistically analyzed by using two way ANOVA and Tukey's multiple comparison test (${\alpha}=.05$). Results: In the scanning electron micrograph of the treated ceramic surface, Group F2 and F3 appeared the high roughness and Group Z3 appeared the highest density of silica particle. In Feldspathic porcelain, the result of measuring shear bond strength showed that Group F3 was measured to be highest and Group F1 was measured to be lowest but there was no statistical significance among Groups. In zirconia, Group Z3 was measured to be highest and Group Z1 was measured to be lowest and there was statistical significance among Groups (P<.05). Conclusion: In zirconia, applying hydrofluoric acid etching and then Silano-pen and silane is effective for composite resin adhesion.

Spatio-temporal Variations in the Dynamics and Export of Large Wood in Korean Mountain Streams (우리나라 산지계류에 있어서 유목 동태의 시.공간적 다양성과 그에 따른 유출 특성)

  • Seo, Jung Il;Chun, Kun Woo;Kim, Suk Woo;Im, Sangjun
    • Journal of Korean Society of Forest Science
    • /
    • v.101 no.3
    • /
    • pp.333-343
    • /
    • 2012
  • In-stream large wood (LW) has a critical impact on the geomorphic characteristics relevant to ecosystem management and disaster prevention, yet relatively little is known about variations in its dynamics and subsequent export on the watershed-scale perspective in Korea. Here we review variations in the dynamics and subsequent export of LW as a function of stream size, which is appropriate for Korean mountain streams. In upstream channels with narrow bankfull widths and low stream discharges, a massive amount of LW, resulting from forest dynamics and hillslope processes, may persist for several decades on valley floor. These pieces, however, are eventually transported during infrequent debris flows from small tributaries, as well as peak hydrology in main-stem channels. During the transport, these pieces suffer fragmentation caused by frictions with boulders, and stream bank and bed. Although infrequent, these events can be dominant processes in the export of significant amounts of LW from upstream channel networks. In downstream channels with wide bankfull widths and high stream discharges, LW is dominantly recruited by forest dynamics and bank erosion only at locations where the channel is adjacent to mature riparian forests. With the LW pieces that are supplied from the upstream, these pieces are continuously transported downstream during rainfall events. This leads to further fragmentation of the LW pieces, which increases their transportability. With decreasing stream-bed slope, these floated LW pieces, however, can be stored and form logjams at various depositional sites, which were developed by interaction between channel forms and floodplains. These pieces may decay for decades and be subsequently transported as particulate or dissolved organic materials, resulting in the limitation of LW fluvial export from the systems. However, in Korea, such depositional sites were developed in the extremely limited streams with a large dimension and no flood history for decades, and thus it does not be expected that the reduction of LW export amount, which can be caused by the long-term storage. Our review presents a generalized view of LW processing and is relevant to ecosystem management and disaster prevention for Korean mountain streams.

A BIOLOGICAL STUDY OF PENAEUS JAPONICUS BATE (보리새우 Penaeus japonicus Bate의 생물학적 연구)

  • PYEN Choong Kyu;RHO Sum
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.3 no.2
    • /
    • pp.93-102
    • /
    • 1970
  • 1. On the basis of the samples collected on the eastern coast of Koje-Do from May to September, 1969, studies have been made on the growth and the relationships between the carapace length and the body length, and between the carapace length and the body weight of Penaeus japonicus Bate. 2. The mean carapace length of P. japonicus was 51mm in May, 57mm in June, 47mm in July and 50mm in September respectively. 3. As a result of the present studies two populations of P. japonicus exist in waters around Koje-Do, namely the spring and fall spawning populations. 4. The relationship between the carapace length ($\iota$) and the body length(L) and between the carapace length and the body weight (W) are indicated by the following equations: May $$L=2.6544{\iota}+3.1258$$ $$W=1.892{\iota}^{1.9844}$$ June $$L=2.8659{\iota}+2.1796$$ $$W=1.082{\iota}^{2.4323}$$ July $$L=2.5840{\iota}+3.3090$$ $$W=1.290{\iota}^{2.3094}$$ September $$L=2.4234{\iota}+4.5775$$ $$W=1.599{\iota}^{2.1857}$$ 5. With regard to the relationships between the carapace length and the body length and between the carapace length and the body weight there is no significant difference between the populations spawning in June and September. 6. The relationships between the carapace length ($\iota$) and the body length (L) and between the carapace length and the body weight (W) for the samples cultured at three different localities are indicated by the following equations: Koje-do $$L=3.7738{\iota}+0.0805\;(r=0.934)$$ $$W=0.4690{\iota}^{3.0713}$$ Oma-do $$L=2.993{\iota}+1.6455\;(r=0.990)$$ $$W=0.6328{\iota}^{2.6579}$$ Kumdang-do $$L=3.2749{\iota}+0.9055\;(r=0.983)$$ $$W=0.5768{\iota}^{2.8076}$$ 7. During the larval stages the relationship between the body length (L) and the rearing day (D) is indicated by the following equations: Zoeal stages (1-3) L=0.1279D+0.2686 (r=0.979) Mysis (1) - Post larva (6) L=0.1697D+0.5634 (r=0.994) Post-larvs (7) - Post larvs (21) L=0.1344D+1.9501 (r=0.978)

  • PDF

Multi-element Ultrasound Applicator for the Treatment of Cancer in Uterus and Cervix (자궁암 치료용 다채널 초음파 온열치료기)

  • Lee Rena
    • Progress in Medical Physics
    • /
    • v.16 no.1
    • /
    • pp.16-23
    • /
    • 2005
  • The objective of this study was to construct multi-element ultrasound applicators for the treatment of gynecologic cancer with high dose rate brachytherapy. For the treatment of uterus, piezo-ceramic crystal transducer (PZT -5A) with outer diameter of 4 mm, wall thickness of 1.3 mm, and length of 24.5 mm was selected. For the treatment of cervix or vagina, it should be possible to insert the applicator into the vagina. Thus, a cylindrical PZT -8 material with outer diameter of 24.5 mm, wall thickness of 1.3 mm, and length of 15.2 mm was selected. The operating frequencies determined by vector impedance measurement were 3.2 MHz for the PZT 5A cylinder (OD=4 mm) and 1.7 MHz for the PZT -8 cylinder (OD: 24.5 mm). The ratios of generated acoustic output power to applied electric power were 33% and 61% for the tandem type crystal and the cylinder type crystal, respectively. The radiated acoustic pressure fields from both transducers were calculated using a Matlab code and measured in water using hydrophone. There was good agreement between measured and calculated acoustic pressure field distribution. For a tandem type transducer, the calculated acoustic pressure field decreased from 0.023 MPa at 10 mm to 0.010 Mpa at 30 mm, the reduction of 57%. For the cylinder type transducer which will be used for the treatment of vagina showed 78% reduction at 15 mm and 66% at 25 mm as compared to values at 5 mm from the surface. Based on the characteristics of the transducers, this study demonstrated the possibility of using the crystals as a heating source. Finally, a 3-element and 4-element prototype applicators were constructed. The 3-element applicator is 75 mm long and 4 mm thick and will be used for the treatment of uterus. The 4-element applicator is 61 mm long and 24.5 mm thick and will be used for the treatment of vagina. Using these applicators, it is possible to generate enough power to increase temperature to therapeutic level.

  • PDF

Evaluation of Absorbed Dose and Skin Dose with MDCT Using Ionization Chamber and TLD (이온 전리함 및 TLD 법을 이용한 Multi-Detector Computed Tomography의 흡수선량 및 체표면 선량 평가)

  • Jeon, Kyung Soo;Oh, Young Kee;Baek, Jong Geun;Kim, Ok Bae;Kim, Jin Hee;Choi, Tae Jin;Jeong, Dong Hyeok;Kim, Jeong Kee
    • Progress in Medical Physics
    • /
    • v.24 no.1
    • /
    • pp.35-40
    • /
    • 2013
  • Recently, the uses of Multi-Detector Computed Tomography (MDCT) for radiation treatment simulation and planning which is used for intensity modulated radiation therapy with high technique are increasing. Because of the increasing uses of MDCT, additional doses are also increasing. The objective of this study is to evaluate the absorbed dose of body and skin undergoing in MDCT scans. In this study, the exposed dose at the surface and the center of the cylindrical water phantom was measured using an pencil ionization chamber, 30 cc ionization chamber and TL Powder. The results of MDCT were 31.84 mGy, 33.58 mGy and 32.73 mGy respectively. The absorbed dose at the surface showed that the TL reading value was 33.92 mGy from MDCT. These results showed that the surface dose was about 3.5% from the MDCT exposure higher than a dose which is located at the center of the phantom. These results mean that the total exposed dose undergoing MDCT 4 times (diagnostic, radiation therapy planning, follow-up et al.), is about 14 cGy, and have to be considered significantly to reduce the exposed dose from CT scan.

Variation of Air Temperature Inside Carbonate Area Caves (석회암 지역에 분포하는 동굴의 내부 온도 변동 특성)

  • Kim, Lyoun;Park, Youngyun;Lee, Jonghee;Choi, Jaehun;Jung, Qyusung;Kim, Jungtae;Kim, Insu
    • Korean Journal of Heritage: History & Science
    • /
    • v.53 no.1
    • /
    • pp.52-63
    • /
    • 2020
  • This study was conducted in order to evaluate the characteristics of air temperature fluctuation inside the Daegeumgul, Ondaldonggul, and Seongnyugul Caves, which are the most representative limestone caves in Korea, and also to assess the effects of air temperature on cave temperature. Temperature was measured hourly at three sites in Daegeumgul, Ondaldonggul, and Seongnyugul Caves from April 13 to June 25, 2019. Additionally, air temperature data for the areas around the caves was provided by the Meteorological Administration. Using this collected data, the basic statistical measure of fluctuation characteristics over time was ascertained, and time series analyses were performed. Wide variation of temperature was exhibited in the order of the cave entrance, the cave water inflow point, and the midpoint. Cave temperature was observed to increase gradually during the study period. There was a vast range in temperature at the Daegeumgul station located approximately 150 m outside the cave, but it remained nearly constant beyond the midpoint. Although the effect of air temperature was not significant due to the influence of visitors, the effect of air temperature on cave temperature gradually decreased from the entrance to the interior. At Ondaldonggul, there was a wide range in temperature recorded at the entrance due to the influence of air temperature, but it stayed almost constant in the interior. However, at the site where cave water flows into the cave, temperature was influenced by the cave water temperature. At Seongnyugul, there was a distinct fluctuation in temperature recorded at the cave entrance, while the middle of the cave remained nearly constant. Temperature fluctuated due to the air temperature at the entrance, while at the middle of the cave, measurements were expected to be affected to a greater extent by the lake water temperature than by the air temperature. However, this pattern was not observed. According to the time series analysis results, in all caves, fluctuations of air temperature affected cave temperature after approximately one hour. Cave size and structure, water presence, the entrance's size and shape, air flow, and visitor patterns can all influence cave temperature. Therefore, consideration of these factors is very important in the pursuit to clearly understand cave temperature characteristics.

Strategy for Bio-Diversity and Genetic Conservation of Forest Resources in Korea (생물종(生物種) 다양성(多樣性) 및 삼림유전자원(森林遺傳資源) 보존(保存) 전략(戰略))

  • Park, Young Goo
    • Journal of Korean Society of Forest Science
    • /
    • v.83 no.2
    • /
    • pp.191-204
    • /
    • 1994
  • Due to its topographic complexities and various climatical condition, Korea exhibits diverse forest types. Dominant tree species in this zone are Quercus spp., Betula spp., Zelkova spp., Fraxinus spp., Pinus densiflora, Pinus koraiensis, and Pinus thunbergii ete. Genetic conservation in forest species in Korea there are three ways ; one is in situ, other is ex situ and third is in-facility conservation. In situ conservation include that are the present status of conservation of rare and endangered flora and ecosystem, the reserved forest, the national and provincial park, and the gene pool of natural forests. Ex situ conservation means to be established the new forest from in situ forest stands, progeny and provenance test populations, seed orchard and clone banks, and gene conservation in-facility. As a tool for low temperature storage, several aspects on in vitro system were studied ; (1) establishment of in vitro cultures from juvenile and/or rejuvenated tissues, (2) induction of multiple shoots from the individual micropropagules, (3) elongation of the proliferated shoots. Studies on cold storage for short-and long-term maintenance of in vitro cultures under $4^{\circ}C$ in the refrigerator were conducted. For the cryopreservation at $-196^{\circ}C$, various factors affecting survivability of the plant materials are being examined. The necessity of gene conservation of forest trees is enlarged not only to increase the adaptability for various environments but also to gain the breeding materials in the future. For effective gene conservation of forest trees, I would like to suggest followings ; 1. Forest stands reserved for other than the gene conservation purposes such as national parks should be investigated by botanical and gene-ecological studies for selecting bio-diversity and gene conservation stands. 2. Reserved forest for gene pool should be extented both economically important tree spp. and non-economical species. 3. Reserved forest for progeny test and clone bank should be systematically investigated for the use of Ex situ forest gene conservation. 4. We have to find out a new methodology of genetic analysis determining the proper and effective size of subpopulation for in situ gene conservation. 5. We should develop a new tree breeding systems for successful gene conservation and utilization of the genetic resources. 6. New method of in-facility gene conservation using advanced genetic engineering should be developed to save time and economic resources. 7. For the conservation of species with short-life span of seed or shortage of knowledge of seed physiology, tissue culture techniques will be played a great role for gene conservation of those species. 8. It is are very useful conservation not only of genes but of genotypes which were selected already by breeding program. 9. Institutional and administrative arrangements including legistlation must be necessarily taken for gene conservation of forest trees. 10. It is national problems for conservation of forest resources which have been rapidly destroyed because of degenerating environmental condition and of inexperienced management system of bio-diversity and gene conservation. 11. In order to international cooperation for exchanging data of bio-diversity and gene conservation, we should connect to international net works as soon as possible.

  • PDF

Studies on the Desertification Combating and Sand Industry Development(IV) - Technology Development for Sanddune Fixation and Sandy Land Conservation in China - (사막화방지(沙漠化防止) 및 방사기술개발(防沙技術開發)에 관한 연구(硏究)(IV) - 중국(中國)의 사구고정(沙丘固定) 및 방사공법분석(防沙工法分析) -)

  • Woo, Bo-Myeong;Lee, Kyung-Joon;Choi, Hyung-Tae;Lee, Sang-Ho;Park, Joo-Won;Wang, Lixian;Zhang, Kebin;Sun, Baoping
    • Journal of Korean Society of Forest Science
    • /
    • v.90 no.3
    • /
    • pp.277-294
    • /
    • 2001
  • This study is aimed to analyze and to evaluate the technology development for sanddune fixation and sandy land conservation in China, resulting from the project of "Studies on the desertification combating and sand industry development". There are various types of sanddunes, including shrub-bunch type, dendritic, honey combed lattice, crescentic, parabolic, pyramid, complex and irregular types, domed, and so on. The height distribution ratios of these sanddunes are 13% of less than 5m, 17% of 6~10m, 18% of 11~25m, 14% of 26~50m, 28% of 51~100m, 10% of more than 100m, and so on. In dry land of China, shifting direction of the sanddune is mainly varying with main direction of wind, but types of shifting sanddunes have many differences in accordance with region, topography, size and shape of sanddunes. The main sanddune fixation technologies could be divided into the bio-ecological measures, physical measures and chemical measures. The bio-ecological measures include such vegetation measures as shrub-grasses measures, sandbreaks between sand dunes, sand fixation shelterblets and establishment of farmland shelterbelts, etc. The physical measures include establishment of high-sanddune stabilization walls and low-sanddune stabilization walls, sanddune fixation levees and coverage method with sediment clay, etc. The chemical measures include fixation-materials spraying and synthetical liquid spraying methods, etc. Besides, irrigation and sand settlement measures, shifting sand trapping channel, ditchsand fixation measures, etc. have been effectively applied.

  • PDF

The evaluation of custo-made EWHA Breast Device(EBD) (EWHA Breast Device(EBD)의 제작 및 유용성 평가)

  • Byun Young-Sik;Oh Tae-Sung;Park Chong-Yil;Shin Hyun-Kyoh
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.17 no.1
    • /
    • pp.33-40
    • /
    • 2005
  • Purpose : We recently perform the latest radiotheraphy (3D conformal, IMRT,etc.) with the development of 3D CT planning technology. However, in case patients with breast cancer, it is difficult to acquire the CT image with the limitation of CT hole size and tilting of breast immobilization device. The Ewha Breast Device(EBD) was constructed to improve the problem in the treatment of patients with breast cancer and we are intend to introduce the procedure of the EBD construction in this study and compare the EBD with conventional breast device in the view point of usefulness. Materials and Methods : We have constructed the EBD with acryl, analyze the skull size with CT data, consider the skin folder in SCL field and evaluated the EBD usefulness from the view point of set-up reproducibility, dose distribution, skin reaction in comparison with conventional breast device. Results : In the case of patients set-up error analysis, the EBD is superior to conventional device in portal film repetition($\%$) check (80pt.), equal to that in simulation & CT image coincidence check(5pt.). There is no difference between the two systems in dose distribution and skin reaction in SCL field is better the EBD than conventional device. Conclusions : The construction of the EBD enable us to perform the latest radiotheraphy in breast treatments, relieve the pains in simulation, and reduce, the skin reaction. In the future, we expect that modification of the EBD is useful in treating for patients with breast cancer.

  • PDF

Patient Dose in Mammography (유방촬영에서 환자 피폭선량)

  • Shin, Gwi-Soon;Kim, You-Hyun;Kim, Jung-Min;Kim, Chang-Kyun;Yang, Jeong-Hwa;Choi, Jong-Hak
    • Journal of radiological science and technology
    • /
    • v.28 no.4
    • /
    • pp.293-299
    • /
    • 2005
  • In the present investigation, we analyzed the data of 1,318 patients (2,636 images) who underwent mammographic examinations and obtained the distribution of the patient age and compressed breast thickness. We measured also average glandular doses (AGD) as function of compressed breast thickness. In order to obtain the values of AGD, we measured half value layer (HVL) and tube output (mR/mAs) for each kVp and target/filter combination. Entrance surface air kerma (ESAK) was calculated from the tube output as measured for each voltage used under clinical conditions and from the tube loading (mAs). AGD per exposure were calculated by multiplying the ESAK values by the conversion factors tabulated by Dance. We obtained in this study the following conclusions. The mean value of compressed breast thickness for cranio-caudal (CC) view was 35.8mm and that for medio-lateral oblique (MLO) view was 43.3 mm. The mean value of AGD for CC view was 1.55 mGy and that for MLO view was 1.70 mGy. The AGD for MLO view was 0.15 mGy (10%) higher than that for CC view because the thickness for MLO view was on average 4.8 mm higher than that for CC view. The values of AGD increased with increasing compressed brest thickness. The increased AGD value was on average 0.34 mGy per 10 mm in the thickness ranges $10{\sim}80\;mm$, therefore differences between the AGD values of each thickness were relative large. Thus, it is considered to need limited doses for mammography with the upper end of exposure range at several different compressed brest thickness.

  • PDF