• Title/Summary/Keyword: 콘크리트 조인트

Search Result 59, Processing Time 0.025 seconds

An Experimental Study for Application on Concrete Expansion Joint and on Cracks Using Oakum and Urethane Resin (황마사와 우레탄을 이용한 콘크리트 익스펜션 조인트 및 균열 적용에 관한 실험적 연구)

  • 최은수;고위경;배기선;오상근;안상덕
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.10b
    • /
    • pp.1085-1090
    • /
    • 2000
  • It is socially increasing the need to maintenance of building's durability and management for building's safety. It has happened in waterproofing field, especially in case of water leakage in expansion joint and cracks, lacking basic design for waterproofing. After the completed of construction, there are many troubles something like this. Therefore it need for development to prevent from water leakage, using oakum and urethane in expansion joint and cracks as a method for waterproofing.

Fire resistance assessment in construction joint of precast fireproof duct slab (프리캐스트 방식 내화풍도슬래브 시공조인트부의 화재저항성능 평가)

  • Choi, Soon-Wook;Kang, Tae-Ho;Lee, Chulho;Kim, Se Kwon;Kim, Tae Kyun;Chang, Soo-Ho
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.23 no.5
    • /
    • pp.359-370
    • /
    • 2021
  • Duct slabs, which are used to build ventilation facilities in underground spaces with transverse ventilation system, need to secure fire resistance according to longitudinal and heavy vehicle traffic of tunnels. This study measured the temperature change at the construction joint of the precast fireproof duct slab which integrates fire resistance material and duct slab under the RWS fire scenario. As a result, it was confirmed that if there is no reinforcement of the construction joint, damage will occur in concrete inside the construction joint, leading to damage to the fireproofing layer. On the other hand, when one side of the construction joint was reinforced with fireproofing materials, it showed more than three times the fire resistance performance compared to when there was no reinforcement. At this time, cross-sectional losses of concrete and fireproofing layer were shown in blocks without reinforcement, but no damage was seen in the reinforced blocks.

철근콘크리트 건물외벽의 수축균열의 실태와 그 대책

  • Lee, Lee-Hyeong
    • Journal of the Korea Construction Safety Engineering Association
    • /
    • v.2 no.1 s.3
    • /
    • pp.65-77
    • /
    • 1992
  • 철근콘크리트 건물에 발생하는 균열은 그 원인이 크게 표1과 같이 콘크리트의 재료성질과 시공 그리고 외적요인과 하중으로 분류되고 있다. 그중 외벽에 발생하는 균열의 원인은 콘크리트 수축에 기인하는 것외에 다짐불량에 의한 코올드 조인트와 철근 부식 등에 의한 팽창균열 등 여러가지가 있다. 본고는 특히 중요한 수축균열에 한정하여 그 실태와 대책의 동향을 설명한다.「수축에 의해 발생하는 균열」의 원인은 콘크리트의 건조수축, 수화열에 의한 열수축 및 외기온의 변동에 의한 온도수축으로 대별될 수 있다. 실제의 건물 외벽균열은 이들이 복합적으로 작용하여 발생한다. 따라서 본 고에서는 이러한 종류의 균열실태에 대해 조사사례와 연구보고를 소개함과 동시에 균열 메카니즘. 방지대책 등에 대해 이해를 돕기 위한 자료를 제공한다. 본고는 1992년 2월에 소유가 발표한 일본 콘크리트 공학의 "RC건물외벽의 수축균열의 실태와 그 대책"을 중심으로 요약한 내용이다.

  • PDF

An Experimental Study on Bonding Performance Evaluation of UHPC in Accordance with Delay Time of Cold Joints (콜드조인트 지연시간에 따른 초고성능 콘크리트의 부착성능평가에 관한 실험적 연구)

  • Jang, Hyun-O;Kim, Bo-Seok;Jang, Jong-Min;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.05a
    • /
    • pp.22-23
    • /
    • 2016
  • This study aims to derive the optimal condition that ensures the monolithicity of ultra-high performance concrete (UHPC), through the evaluation of bonding shear performance with respect to the time of cold joint occurrence during the placement. From the direct shear test, while the normalized bonding shear strength reduction of UHPC with the delay time of 15 minutes was the lowest at around 8%, a dramatic degradation of bonding shear performance was observed after 15 minutes. XRD analysis of the middle and surface sections was performed in order to analyze the composition of the thin film formed at the surface of UHPC, and as a result, the main ingredient appeared to be SiO2 from the XRD pattern of middle and surface sections, which is believed to be the result of the rising of SiO2-based filler, used as anadmixture in this study, toward the surface, due to its low specific gravity.

  • PDF

Experimental evaluation of fire protection measures for the segment joint of an immersed tunnel (침매터널 세그먼트조인트의 내화 대책에 대한 실험적 평가)

  • Choi, Soon-Wook;Chang, Soo-Ho;Kim, Heung-Youl;Jo, Bong-Hyun
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.13 no.3
    • /
    • pp.177-197
    • /
    • 2011
  • In this study, a series of fire experiments under $HC_{inc}$ and ISO834 (duration of 4 hour) fire scenarios were carried out for three different types of fire protection measures for the segment joint to evaluate their applicabilities to an immersed tunnel. The experimental results revealed that an expansion joint installed to allow relative movements between concrete element ends in an segment joint is the most vulnerable to a severe fire. For the fire protection measure where the originally designed steel plates at an expansion joint arc replaced by fire-resistant boards, the experiments showed that they cannot achieve good fireproofing performance under both $HC_{inc}$ fire scenario and ISO834 (4 hour) fire scenarios since the installation of fire-resistant boards results in the reduction of the sprayed fire insulation thickness. On the other hand, the application of modified bent steel plates replacing the original steel plates was proved to be very successful in fireproofing of the expansion joint due to more sprayed materials filled in bent steel plate than in the original design concept as well as higher adhesion between the steel plate and the sprayed fire insulation layer.

Estimation of the Proper Placement Range of SRA Concrete for the Integration of Cold Joints (콜드조인트 일체화를 위한 초지연 콘크리트의 적정 타설 범위 도출)

  • Jeong, Jun-Taek;Kim, Soo-Ho;Jeong, Yeong-Jin;Hyun, Seung-Yong;Kim, Jong;Han, Min-Cheol
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.05a
    • /
    • pp.259-260
    • /
    • 2023
  • This study attempted to derive an appropriate application range by reviewing the integration performance of joints according to the application range of SRA concrete. As a result, it was confirmed that the integration performance was improved even if SRA concrete was placed only by 75mm, which is 0.5 times the thickness of the member.

  • PDF

Comparison of Performance & Jet Fuel Oil Resistance of Joint Sealant Materials for Airside (공항용 조인트 충진재의 성능 및 내유저항특성 비교연구)

  • Park, Tae Soon;Lee, Keun Sik;Lee, Su Hui
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.4D
    • /
    • pp.587-592
    • /
    • 2006
  • The joint sealants used in the airside should resist the high temperature of the jet blast and the jet fuel oil spilled when the aircraft is maintained and filled. The material of joint sealant for the airside should be different from that for the road due to these characteristics. Three different kinds of the joint sealant materials were tested in this paper. The materials include the polysulfide, the polyurethane and the silicon. The test results show that the physical properties and the performance of the polysulfide show the high resistance to the jet blast and the jet fuel oil. When the characteristics of the airside considered, the polysulfide may apply in the both of the runway and the apron area, the polyuretane can be applied the taxiway. The use of the silicon sealant is not recommended for the airside.

Numerical study on the structural stability of the precast joint buttress wall (프리캐스트 조인트 방법을 사용한 부벽식 옹벽의 구조적 안정성에 대한 수치해석 연구)

  • Kim, Joonseok
    • Journal of the Society of Disaster Information
    • /
    • v.12 no.4
    • /
    • pp.366-372
    • /
    • 2016
  • Recently in case of the concrete retaining wall precast technological change in the field assembled by the way. A precast wall is devied into upper and lower respectively, and the way, assembled in field is being performed. But the assembled part could have been damaged by the earth pressure in a relatively high buttress wall. And, it have been pointed out that large-scale disaster can be occurred. Thus, in this thesis, a structural stability for the buttressed retaining wall with pre-cast joint method was analyzed by a numerical analysis method. The structural stability of the three height retaining wall(7.6m, 8.5m, 10m) was conducted respectively for earth pressure. The maximum principal stress applied to the concrete retaining wall was analyzed to occur locally in the vicinity of the fixing anchor as 23.3 ~ 43.2 MPa.

A Study on Properties of Retarder via Tabletting Method (정제화 방법을 이용한 응결 지연제의 특성에 관한 연구)

  • Ryou, Jae-Suk;Yang, Neung-Won;Lee, Yong-Soo
    • Journal of the Korea Concrete Institute
    • /
    • v.25 no.2
    • /
    • pp.201-207
    • /
    • 2013
  • When hot weather concrete is utilized, the cooling methods of cooling pipe, liquid nitrogen, ice, etc., are used to prevent the poor consistency and cold joint due to high temperature. These methods, however, spike the production cost and energy consumption, and make quality control difficult. Among these methods is one that involves the use of a retarder. Although economical, retarder is caused difficulty of retarded hardening and setting time control due to inaccurate weighing and poor working condition. Therefore, how to make a tablet for hot weather concrete, as with the existing pharmacy and foods, is discussed in this study, including the following items: mortar setting time, flow test by elapsed time, physical and mechanical properties of concrete. As a result, gluconic acid is superior to lignosulfonic acid and the possibility of using them for such purpose without quality degradation was confirmed in this study, when retarder is tabletting.

The effects of Joint Stiffness On Concrete Pavements (콘크리트 포장구조에서 조인트 강성의 영향)

  • 조병완
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1990.04a
    • /
    • pp.50-52
    • /
    • 1990
  • Although concrete pavements were successfully widespread throughout the nation due to the desirable surface characteristics, durability, and economy, it still causes several transverse cracking and joint failure problems in some areas. In this paper, the major emphasis was given to provide a rational analytical approach on joint failure mechanisms, considering several sets of joint stiffnesses on different subgrade moduli. Besides , load transfer mechanisms on concrete pavement joints were highlighted with finite element method and computer modeling.

  • PDF