Browse > Article
http://dx.doi.org/10.9711/KTAJ.2021.23.5.359

Fire resistance assessment in construction joint of precast fireproof duct slab  

Choi, Soon-Wook (Department of Geotechnical Engineering Research, Korea Institute of Civil Engineering and Building Technology)
Kang, Tae-Ho (Department of Geotechnical Engineering Research, Korea Institute of Civil Engineering and Building Technology)
Lee, Chulho (Department of Geotechnical Engineering Research, Korea Institute of Civil Engineering and Building Technology)
Kim, Se Kwon (Research Institute, HONG G)
Kim, Tae Kyun (HONG G)
Chang, Soo-Ho (Construction Industry Promotion Department, Korea Institute of Civil Engineering and Building Technology)
Publication Information
Journal of Korean Tunnelling and Underground Space Association / v.23, no.5, 2021 , pp. 359-370 More about this Journal
Abstract
Duct slabs, which are used to build ventilation facilities in underground spaces with transverse ventilation system, need to secure fire resistance according to longitudinal and heavy vehicle traffic of tunnels. This study measured the temperature change at the construction joint of the precast fireproof duct slab which integrates fire resistance material and duct slab under the RWS fire scenario. As a result, it was confirmed that if there is no reinforcement of the construction joint, damage will occur in concrete inside the construction joint, leading to damage to the fireproofing layer. On the other hand, when one side of the construction joint was reinforced with fireproofing materials, it showed more than three times the fire resistance performance compared to when there was no reinforcement. At this time, cross-sectional losses of concrete and fireproofing layer were shown in blocks without reinforcement, but no damage was seen in the reinforced blocks.
Keywords
Tunnel; Fire; Duct slab; Construction joint; Temperature;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Chae, W.B., Kim, K.R., Seo, S.K. (2011), "Fireproofing mortar mixed with recycled fine aggregate and porous ceramic for tunnel covering material", Proceedings of 2011 Fall Conference of the Korea Concrete Institute, Pyeongchang, pp. 733-734.
2 Choi, S.W., Chang, S.H., Kim, H.Y., Jo, B.H. (2010), "Assessment of structural fire resistance of a fire-proofed immersed tunnel under tunnel fire scenarios", Journal of Korean Tunnelling and Underground Space Association, Vol. 12, No. 6, pp. 429-441.
3 Choi, S.W., Kang, T.H., Lee, C., Kim, S.K., Kim, T.K., Chang, S.H. (2020), "Fire resistance assessment of precast fireproof duct slab", Journal of Korean Tunnelling and Underground Space Association, Vol. 22, No. 6, pp. 669-680.   DOI
4 Hertz, K.D. (2003), "Limits of spalling of fire-exposed concrete", Fire Safety Journal, Vol. 38, No. 2, pp. 103-116.   DOI
5 ITA (2004), Guidelines for structural fire resistance for road tunnels, Working Group No. 6 Maintenance and Repair, pp. 2-4~6.
6 Kwon, K., Shin, H., Kim, H. (2016), "Evaluation of the damage by a fire of the full scale concrete tunnel lining exposed to the high temperature", Journal of the Korean Society of Hazard Mitigation, Vol. 16, No. 2, pp. 9-15.   DOI
7 PIARC (1999), Fire and Smoke Control in Road Tunnels, PIARC Committee on Road Tunnels, May, pp. 57-58.
8 Won, J.P., Jang, C.I., Lee, S.W., Kim, H.Y., Kim, W.Y. (2008), "Spalling and internal temperature distribution of high strength column member with polypropylene fiber volume fractions", Journal of the Korea Concrete Institute, Vol. 20, No. 6, pp. 821-826.   DOI
9 Chang, S.H., Choi, S.W., Kwon, J.W., Kim, S.H., Bae, G.J. (2007), "Alteration of mechanical properties of tunnel structural members after a tunnel fire accident", Journal of Korean Tunnelling and Underground Space Association, Vol. 9, No. 2, pp. 157-169.
10 Clement, F., Focaracci, A. (2011), "Fire protection in tunnels: resquirements, solutions and case histories", Proceedings of the WTC2011, Helsinki, Finland.
11 Khoury, G.A., Majorana, C.E., Pesavento, F., Schrefler, B.A. (2002), "Modelling of heated concrete", Magazine of Concrete Research, Vol. 54, No. 2, pp. 77-101.   DOI
12 Phan, L.T. (1996), Fire performance of high-strength concrete: a report of the state-of-the-art, NISTIR 5934, National Institute of Standards and Technology, pp. 59-60.
13 Kodur, V.K.R., Dwaikat, M. (2008), "A numerical model for predicting the fire resistance of reinforced concrete beams", Cement and Concrete Composites, Vol. 30, No. 5, pp. 431-443.   DOI