• Title/Summary/Keyword: 콘크리트 단면복구

Search Result 20, Processing Time 0.027 seconds

A Study on the Durability of Restorative Cement Mortar with Insulation Performance (단열성 단면복구 Mortar의 내구성에 관한 연구)

  • Na, Seung-Hyun;Kim, Hyung-Jin;Su, Byung-Dol;Kang, Hyun-Ju;Song, Myong-Shin
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2009.05a
    • /
    • pp.495-496
    • /
    • 2009
  • The restorative materials for deteriorated concrete are estimated by various kinds of strength, carbonation, and at same time, by various deteriorate factors and others. So, it's properties must have maintained many functional properties. In this study, to improvement of durability of restorative materials, we take restorative materials with insulation performance, for deterioration by temperature exchange as deterioration factor.

  • PDF

RC조 보수에 사용되는 폴리머시멘트 몰탈의 철근 부착특성 평가

  • Park, Dong-Cheon
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2013.10a
    • /
    • pp.247-249
    • /
    • 2013
  • 열화한 철근콘크리트 구조물에 대하여 성능회복을 위하여 전기화학적 방식, 단면복구공법, 균열보수공법, 표면마감공법 등이 상용되고 있다. 본 연구에서는 단면복구공법의 적용과 성능예측을 위한 해석 모델의 입력값으로 사용될 보강철근과 단면복구재의 부착특성을 평가하기 위하여 철근인발실험을 실시하였다. 폴리머시멘트몰탈이 사용되었으며 부착요소의 강성과 강도를 구하여 비선형 해석을 실시하여 상당한 정확도의 예측값을 도출하였다.

  • PDF

Flexural and Cracking Characteristics of Concrete Beams Exposed to Freeze-Thaw Cycles after Patch-Repaired with SHCC (SHCC로 단면 복구후 동결융해에 노출된 콘크리트 보의 휨 및 균열특성)

  • Yun, Hyun-Do;Kim, Sun-Woo;Jeon, Ester;Lee, Young-Oh;Jang, Kwang-Soo;Park, Whan-Shin
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2009.05a
    • /
    • pp.21-22
    • /
    • 2009
  • This paper presents the results of an experimental study on flexural behavior and cracking process of concrete beams subjected to cycles of freezing and thawing after patch-repaired with strain-hardening cement composites (SHCCs). The SHCCs were reinforced with hybrid 0.75% PVA and 0.75% PE fibers. Experimental testing of concrete beams patch-repaired with SHCCs revealed that the SHCC patch-repair system without freeze thaw (FT) exposure showed average 3.31 times increased load carrying capacity and for beams exposed to 300 FT cycles, load carrying capacity increased up to 2.42 times. Cracking damage of SHCC patch-repaired beams mitigated compared to plain concrete beams but this trend decreased under FT exposure.

  • PDF

Study on Influence Strengthening Surface of Concrete by Metallic Lithium (리튬금속이 콘크리트 표면강화에 미치는 영향)

  • Kim, Kwang-Ki;Park, Soon-Jeon;Jung, Sang-Jin
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2009.05a
    • /
    • pp.513-514
    • /
    • 2009
  • This study is to determine that lithium-silicate as reinforcement on surface for repairing concrete structure affects adhesive strength of mortar to recover the surface and of the strength for the obverse of concrete. these are focused on applying fields to the study.

  • PDF

Revision of Repair Materials Performance Requirement for Concrete Structures (콘크리트 구조물 단면복구공사 보수재료 품질기준개선)

  • Lee, Il Keun;Kim, Ki Hwan;Kim, Hong Sam;Yun, Sung Hwan;Kim, Woo Seok
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.43 no.1
    • /
    • pp.9-20
    • /
    • 2023
  • For highway concrete structures, the deterioration of the structure is accelerated due to the increase in the use of deicing materials, and sectional repair work is being frequently carried out to restore performance. However, after the repair work, re-damage such as cracks, delamination, and poor bond performance is exhibited in the repaired sectional area. In this study, overseas repair material requirements were first analyzed, and present domestic requirements were improved repair material performance through field surveys of common concrete structures, laboratory experiments, and test construction on a disused concrete bridge. In addition, performancebased quality requirements were presented so that all materials that meet the required performance can be applied, and different test methods for each material were unified into concrete test methods for consistent test results analysis. The considered performance requirements were compression strength, bending strength, and bond strength for structural properties, and length change rate, crack resistance, thermal expansion coefficient, and elasticity coefficient were for dimensional behavior. For resistance to chloride penetration resistance and freeze-thaw resistance were presented as durability. The proposed requirements for concrete repair materials are expected to contribute to the improvement of the quality of concrete sectional repair work in Korea.

An Experimental Study of Flexural Strengthening Method of Reinforced Concrete Beams with Near Surface Mounted CFRP Strips (탄소섬유판 (CFRP) 표면매립 (NSM) 공법을 이용한 콘크리트 구조물 휨 보강에 관한 실험 연구)

  • Lim, Dong Hwan
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.1
    • /
    • pp.131-136
    • /
    • 2013
  • The purpose of this study is to establish the flexural strengthening method of the concrete members. To accomplish this objective, a total of seven concrete beams were tested. From this study, it is found that the initial flexural stiffness and strength of the beams reinforced with NSM CFRP strips were significantly improved compared to the beam without CFRP strip. Failure of the beam reinforced with NSM strips is initiated by failure of NSM strips, eventually sudden explosive compressive failure in the loaded region. This strengthening method combined with NSM CFRP strips and high performance mortar for concrete cover recovery is evaluated by a good strengthening method for the strength, durability and good appearance of concrete structures.

An Experimental Study on the Fundamental Properties and Durability of Sewer Type Restorative Mortar Spread with Antibiotics (항균제를 도포한 하수시설용 단면복구 모르타르의 기초물성 및 내구특성에 관한 실험적 연구)

  • Kim, Moo-Han;Kim, Gyu-Yong;Kim, Jae-Hwan;Cho, Bong-Suk;Lee, Dong-Heck
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.10 no.3
    • /
    • pp.195-202
    • /
    • 2006
  • Deterioration of sewer concrete is representative that biochemical corrosion according to the $H_2S$ has growth by inhabit sulfur-oxidzing bacteria because of special environment in sewer. But in case of domestic, fundamentally, sulfur-oxidzing bacteria could moderate development of repair material method is need because of corrosion prevent method is inconsideration with carry out to improve project. In this paper, after development of spread type antibiotic with antibio-metal, antibacterial performance about sulfur-oxidzing bacteria of antibiotic and tested to estimate fundamental properties of bonding strength, abrasion contents, contents of water absorption, contents of air permeability, carbonation depth, chloride ion penetration depth and chemical resistance of spread with antibiotic restorative mortar.

Performance Evalution of Chloride Ion Penetration of Polymer Mortar for Section Restoration (단면복구용 폴리머 모르타르의 염소이온 투과성 평가)

  • Park, Sung-Woo;Kang, Dong-Soo;Han, Bog-Kyu
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05b
    • /
    • pp.285-288
    • /
    • 2006
  • Recently, polymer mortar has been developed not only more improving the performance of modified mortar with polymer, but also protecting and repairing materials of structures, especially in marine environment because of their excellent performance to improve compressive strength, flexural strength, and adhesive strength. however, in fact, these rehabilitation techniques in marine environment, which consist of removing delaminated areas of concrete, cleaning affected steel and patching with polymer mortar, have proven to be ineffective for marine structures. Also, repairs are often repeated every several years. Therefore, it is neccessary to research performance evalution of chloride ion penetration of polymar mortar for section restoration.

  • PDF

A Study on the Characteristics of Inorganic Polymer Mortar for Concrete Sectional Rehabilitation (콘크리트 단면복구용 무기성 모르타르의 특성에 관한 연구)

  • Hwang, Tae-Ha;Song, Tae-Hyeob;Im, Chil-Soon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.14 no.3
    • /
    • pp.171-177
    • /
    • 2010
  • As concrete structures are exposed to chemical substances, damaged from salt, or progressed to the neutralization, the surface damage of the structures is generated timely fashion, resulting shortened service life. Especially, the sulfate erosion causes rapid surface defects, and the steel skeleton becomes corroded due to the water infiltration, generating stability deterioration of the concrete structure. In this study, the physical characteristics of the acid-resistant mortar with aluminosilicates was investigated in order to resolve problems of the acid resistance, one of the most serious problems of the cement type repair material. As the result of the experiment, the test specimen turned to exhibit almost equivalent physical characteristics with those of concrete sectional repair materials in terms of compressive and bending strengths. As both the cement sectional repair material and the test specimen were immerged in sulfuric acid solution to examine weight changes, the test specimens exhibited only 4% loss of their weights while the cement sectional repair materials reached at the level of 80% or above, proving the excellence acid resistant characteristics of the test specimens. Consequently, the physical characteristics of acid resistant mortar with aluminosilicates were revealed to be superior than those of concrete sectional repair materials. It can be utilized as a sectional repair material where the acidic erosion is anticipated.

Material Properties Depending on the Maximum Aggregate Size and Fineness Modulus for Concrete Repair Materials (콘크리트 단면복구용 보수재료의 굵은 골재 최대치수 및 조립률에 따른 재료적 특성)

  • Sun-Mok Lee;Byung-Je Lee;Yun-Yong Kim
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.6
    • /
    • pp.62-69
    • /
    • 2023
  • Re-damage is frequently occurring for various reasons, including material factors, external factors, and factors caused by poor construction in concrete cross-section restoration work, so it is necessary to identify the cause and improve it. Cement-based materials are the most commonly used maintenance materials for concrete structures, and in particular, additional cross-sectional restoration work may be carried out due to re-damage such as cracks and excitement due to dry contraction of the repair material. In this study, a basic study was conducted to identify the characteristics of concrete while diversifying the maximum dimensions and assembly rate of thick aggregates to examine the effects of using thick aggregates in repair materials. As a result, the slump of concrete increased as the maximum size of thick aggregates increased, and the amount of air content was measured 1.88 to 2.35 times higher in the mixing using aggregates with a maximum aggregate size of 5 mm or more compared to the mixing group with a maximum aggregate size of 10 mm or more. It was found that compressive strength was greatly affected by the performance rate of thick aggregates. The compressive strength was measured the highest in the mixture using thick aggregates with the highest performance rate of 20 mm, and the compressive strength of the mixture with the lowest performance rate was more than 45%. As a result of the dry shrinkage measurement, the dry shrinkage was the lowest as the performance rate of the thick aggregate increased according to the change in the maximum dimensions and assembly rate of the thick aggregate, and the lowest performance rate was the largest in the mix. Through this study, it was confirmed that adjusting the particle size by diversifying the maximum dimensions and assembly rate of thick aggregates used in concrete structure repair materials can improve strength and workability and reduce dry shrinkage.