• Title/Summary/Keyword: 콘크리트 건물

Search Result 533, Processing Time 0.023 seconds

Analysis on the Behaviors of Precast Concrete Beam-Column Connections Subject to Cyclic Loading (반복하중을 받는 프리캐스트 콘크리트 건식 보-기둥 연결부의 거동분석)

  • Song, Hyung-Soo;Yu, Sung-Yong
    • Journal of the Korea Concrete Institute
    • /
    • v.18 no.4 s.94
    • /
    • pp.497-506
    • /
    • 2006
  • The precast concrete beam-column connectors for the high-rise office buildings were investigated experimentally in this study. The specimens of general precast beam-column connector which is used in a domestic site, specimen of DDC(dywidag ductile connectors) of Germany, and specimen of DDC with post-tensioning and modified DDC with post-tensioning were constructed and tested to verify the safety. The DDC with and without post-tensioning showed reliable joint strength and ductility but failed in critical inclined shear crackings at the column. The modified one showed better behaviors in tests because they did not show critical column crackings at failure. The use of prestressing did not helpful significantly to increase the strength and ductility of connectors but helpful only to develop self-centering behavior for stability.

Flexural Capacity of Encased Composite Beam with Hollow Core PC Slabs (매입형 합성보의 휨 성능 평가 -속 빈 프리캐스트 콘크리트 슬래브와 비대칭 H형강 철골보-)

  • Heo, Byung Wook;Bae, Kyu Woong;Moon, Tae Sup
    • Journal of Korean Society of Steel Construction
    • /
    • v.16 no.5 s.72
    • /
    • pp.587-598
    • /
    • 2004
  • In this study, an experiment was conducted on the Slim Floor system, using a hollow core PC slab, which could reduce the over-all depth of a composite beam. The Slim Floor system is a method used in steel frame multi-story building construction, in which the structural depth of each floor is minimized after incorporating the steel floor beams within the depth of the concrete floor slab. This experimental study focused on the flexural behavior of the partially connected Slim Floor system with asymmetric steel beams encased in hollow core PC slabs. Ten full-scale specimens were constructed and tested in this study, with different steel beam heights, hollow core PC slabs, slab widths, and PC slab bearings. Observations made in line with the experiments indicated that the degree of shear connection without additional shear connection was 0.48-0.98 times more than that of the full shear connection, due to inherent mechanical and chemical bond stress.

Performance of Reinforced Concrete Beams Strengthened with Bi-directional CFRP Strips (이 방향 탄소섬유 스트립을 사용하여 보강된 콘크리트 보의 거동에 대한 연구)

  • Kim, Changhyuk
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.6
    • /
    • pp.30-36
    • /
    • 2018
  • Researches on strengthening and rehabilitation are important since structural capacity is degraded by deterioration or damage of structural members. An effective strengthening scheme such as an externally bonded Carbon Fiber Reinforced Polymers (CFRP) can improve the structural performance of a concrete structure in a cost-effective way. Therefore, many experimental studies on strengthening methods have been widely carried out. In regards to the shear strengthening of a concrete beam, variables of the experimental studies were the amount of CFRP, the angle of the strip, the width of the strip, and the interaction between the materials. However, there are insufficient researches on bi-directional CFRP layout compared to the previous researches. In this study, a total of ten concrete beams were designed and tested to evaluate the shear strengthening effect using CFRP strips. The effectiveness of strengthening was investigated based on the shear contribution of materials, strain distribution of stirrup, and the maximum shear capacity of specimens.

Current Technical Tendency of Chemical Grouting (약액주입공법의 국내ㆍ외 기술 동향)

  • 김진춘
    • Magazine of the Korea Concrete Institute
    • /
    • v.14 no.5
    • /
    • pp.47-53
    • /
    • 2002
  • 근래 지구촌의 산업화가 가속됨에 따라 대지의 활용도가 급속하게 증가하고 있으며 아울러 인구의 증가 및 개개인 삶의 공간적 범주가 점점 확대되면서 지구상에 광범위하게 분포되어 있는 연약지반으로의 관심이 집중되고 있는 실정이다. 최근 국내에서도 고속철도, 인천국제공항, 도심지 지하철 및 서ㆍ남해안 항만공사 등 대규모 국가건설공사가 진행 중에 있으며 더더욱 임해시설의 확충이라든지 인공섬 등의 건설이 활발해지면서 연약지반에 대한 관심이 고조되고 있다. 하지만 연약지반의 특성을 경시한 나머지 터널의 붕락, 주변지반 및 인접건물의 부등침하, 측방유동에 의한 구조물변위 등 대형 안전사고가 빈발하게 발생되어 왔다. 이러한 안전사고의 대책으로서 지반보강을 위한 여러 가지 신공법이 개발되었고, 새로운 터널보조공법이 국내 지하철건설현장에서 널리 쓰여지고 있으며 이러한 공법 등을 통한 성과도 적지 않게 보고되고 있다.(중략)

Effect of Reference Axis of RC Buildings on Seismic Design Member Forces (RC 건물에서 주축의 설정이 설계지진력에 미치는 영향)

  • Lee, Han-Seon;Ko, Dong-Woo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.05a
    • /
    • pp.704-707
    • /
    • 2004
  • The structure should be designed to be safe to any direction of earthquake input. However, the reference axes whereby the structure is analyzed and designed against earthquake may influence the design member forces. This study is concerned with the effect of the choice of the reference axes on the seismic design member forces. The analytical results on member forces using the principal axes suggested by Wilson and the global axes generally adopted in design offices show that the values of member forces by the principal axes be about $15\%$ smaller than those by the global axes in the example structure.

  • PDF

Shaking Table Tests of the 1/3 Scaled R/C Building with the Laminated Rubber Bearings (적층고무형 면진장치를 갖는 RC건물의 면진효과 검증 진동대 실험)

  • Kim Dong Young;Chun Young Soo;Whang Ki Tea;Chang Kug-Kwan
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.05a
    • /
    • pp.420-422
    • /
    • 2004
  • This paper reports the results of performance verification tests of the base isolated RC building with the laminated rubber bearings which is manufactured by Dongil Rubber Belt Co.. The shaking table tests were performed using a scaled 3-story model scaled to 1/3 of the prototype RC apartment building. Several major earthquake records were scaled to different peak ground accelerations and used as input base excitations. Through the verification tests, the validity of the applied base isolation device and the response reduction effect against earthquakes are confirmed.

  • PDF

Axisymmetric Modeling of Prestressing Tendons of the Nuclear Containment Building Dome (원전 격납건물 돔의 축대칭 텐던 모델링 기법)

  • Jeon Se Jin;Chung Chul Hun;Kim Young Jin;Chung Yun Suk
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.05a
    • /
    • pp.758-761
    • /
    • 2004
  • Prestressing tendons of the nuclear containment building dome are arranged in a non-axisymmetric manner. However, simple axisymmetric modeling of the containment building is often employed to estimate the structural behavior for, e.g. the ultimate pressure, which requires the axisymmetric approximation of the actual tendon arrangements of the dome. A procedure is proposed that can devise the actual 3-dimensional tendon stiffness and prestressing effect into the axisymmetric model. A numerical example of the CANDU type is presented to verify the procedure and to estimate the amount of approximation.

  • PDF

3층 규모 건물이 있는 콘크리트 플로팅 함체의 설계 연구

  • Lee, Yeong-Uk;Park, Jeong-A;Choe, Ji-Hun;Park, Tae-Jun
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2012.06a
    • /
    • pp.419-421
    • /
    • 2012
  • 높이 2.5m의 콘크리트 플로팅 함체에 3층 규모의 상부골조가 있는 예제에 대해 동적 유체 해석과 정적 구조 해석을 수행하고 그 결과에 따라 종방향설계, 함체의 상부 및 하부 슬래브, 외벽 및 격벽에 대한 설계를 수행하였다. 환경 하중은 새만금 방파제 내부 정수역을 기준으로 파도주기 3.7초, 유의파고 1.0m와 풍속 40m/s를 적용하였으며, 하중조합은 ASCE/SEI 7-10을 기준으로 설계 하였다. 예제 구조물에 대한 설계 결과 고정하중에 의한 영향이 활하중 및 파랑하중에 비해 크게 나타났으며, 이로 인해 중앙부의 철근비가 높아지므로 고정하중을 감소시키는 방안을 검토하여야 함을 확인하였다. 또한 보의 지속하중에 의한 장기처짐과 추가적인 활하중에 의한 순간 처짐의 값이 허용 처짐값보다 크므로 보에서의 프리스트레싱을 고려해야 할 것으로 판단된다.

  • PDF

플로팅 함체의 시공단계별 수직처짐의 영향

  • Lee, Yeong-Uk;Chae, Ji-Yong
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2012.06a
    • /
    • pp.422-424
    • /
    • 2012
  • 본 연구에서는 수상위에 진수된 콘크리트 플로팅 폰툰에 상부골조를 단계별로 시공함에 따라 발생하는 추가 처짐이 상부골조에 미치는 영향을 고찰하고 하였다. 이러한 추가변형에 의한 상부골조에 추가 모멘트량을 산정하는 해석절차를 제시하였으며 제시된 절차에 따라 3층 예제 철골 건물을 해석하고 분석하였다. 제시된 시공단계를 고려한 해석 방법과 비교하여, 상부골조를 지반위에 고정하여 모델링하는 일반적인 해석은 수직하중에 의한 변형을 무시하여 설계하중을 과소평가 하며, 플로팅 구조물을 전체적으로 모델링하고 하부 폰툰에 등가의 스프링으로 치환하여 하중을 동시에 재하하는 모델은 과대한 처짐의 영향으로 설계하중을 과대 평가함을 알게 되었다.

  • PDF

A study on the Reliability Analysis of Nuclear Steel Containment Structures Subject to Internal Pressure (내압을 받는 원전 강재격납건물의 신뢰성 해석)

  • 오병환;최성철
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.04a
    • /
    • pp.229-232
    • /
    • 1999
  • Nuclear power plant structures may be exposed to aggressive environmental effects that may cause their damage mechanisms are reasonably well understood and quantitative evaluation of their effects on time-dependent structural behavior is possible in some instances, such evaluations are generally very difficult and remain novel. The assessment of existing steel containment in nuclear power plants for continued service must provide quantitative evidence that they are able to withstand future extreme loads during a service period with an acceptable level of reliability. Rational methodologies to perform the reliability assessment can be developed from mechanistic models of structural deterioration, using time-dependent structural reliability analysis to take loading and strength uncertainties into account. The final goal of this study is to develop the analysis method for the analysis for the reliability of containment structures. The cause and mechanism of corrosion is first clarified and the reliability assessment method has been established. By introducing the equivalent normal distribution, the procedure of reliability analysis which can determine the failure probabilities has been established.

  • PDF