• 제목/요약/키워드: 콘크리트양생

검색결과 740건 처리시간 0.021초

발파진동의 크기가 양생콘크리트의 강도와 물성에 미치는 영향 (Effects of Blasting Vibrations on Strength and Physical Properties of Curing Concrete)

  • 임한욱;박근순;정동호;이상은
    • 터널과지하공간
    • /
    • 제5권2호
    • /
    • pp.134-143
    • /
    • 1995
  • Effects of blasting vibrations on curing concrete have not been well studied. As a result, unreasonable and strong blasting vibration constraints have been placed on blasting when it occurs in the vicinity of curing concrete. To study the effects of blasting on curing concrete blocks of 33.3X27.7X16.2 cm were molded and placed on the quarry. Several sets of concrete blocks were subjected separately to peak vibrations of 0.25, 0.5. 1.0, 5.0, and 10cm/sec. The impulses of blasting vibrations were applied with thirty-minute intervals. Along with unvibrated concrete blocks, the vibrated concrete samples cored with 60.3 mm in diameter were measured for elastic moduli, sonic velocity and uniaxial compressive strength. Test results can be summarized as follows; 1. The blasting vibrations between 6 and 8 hours after pour generally lowered on the uniaxial compressive strength of the concrete. 2. A low blasting vibration of 0.25 cm/sec did not affect the uniaxial compressive strength. As the magnitude of the blasting vibration increases, compressive strength of concrete is decreased. 3. Physical properties of the P-wave velocity, Young's modulus, and Poisson's ratio showed a weakly decreasing trend in the concrete blocks vibrated between 6 and 8 hours after pour.

  • PDF

혼화재 치환 콘크리트의 압축강도 증진해석 (Estimation of Compressive Strength of Concrete Incorporating Admixture)

  • 주은희;배장춘;한민철;손명수;전현규;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2005년도 추계 학술논문 발표대회
    • /
    • pp.75-78
    • /
    • 2005
  • This raper investigates the effect of curing temperature on strength development of concrete incorporating cement kiln dust(CKD) and blast furnace slag (BS) quantitatively. Estimation of compressive strength of concrete was conducted using equivalent age equation and rate constant model. An increasing curing temperature results in an increase in strength at early age, but with the elapse of age, strength development at high curing temperature decreases compared with that at low curing temperature. Especially, the use of 35 has a remarkable strength development at early age and even at later age, high strength is maintained due to accelerated pozzolanic activity resulting from high temperature. Whereas, at low curing temperature, the use of BS leads to a decrease in compressive strength. Accordingly, much attention should be paid to prevent strength loss at low temperature. Based on the strength development estimation using equivalent age equation, good agreements between measured strength and calculated strength are obtained.

  • PDF

전기발열시트 표면가열 양생공법의 현장적용 연구 (An Experimental Study on the Application in-situ of Curing Method by Planar Surface Heater for Cold Weather Concreting)

  • 김형래;조호규;김찬수;지남용
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2003년도 학술.기술논문발표회
    • /
    • pp.19-22
    • /
    • 2003
  • The purpose of this study is to analyze the curing effect of planar surface heater for concreting in cold weather. Some experiments were conducted to evaluate the temperature history of concrete structures cured with heating sheets. Results are as follows ; (1) The temperature of concrete showed continuously rising trend with the heating by planar surface heater under the cold environmental condition of 3~-12$^{\circ}C$. And after about 24 hours the maximum temperature of concrete was reached at 25~3$0^{\circ}C$. (2) The temperature of slab concrete heated by planar surface heater of 130W/$m^2$ was at least $25^{\circ}C$ higher than that of an exterior air, and the curing performance was much more effective than heating by hot wind machine. (3) Through the curing by planar surface heater for 48 hours, the concrete maturity of about 1.5 times to heating by hot wind machine was acquired.

  • PDF

한중환경하 타설된 구조체콘크리트의 결합재 종류별 관리재령 28일 설계기준강도 확보 기법 (The designed compressive strength assurance method to the concrete subjected to cold weather at 28 days)

  • 이영준;현승용;이상운;이정교;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2018년도 춘계 학술논문 발표대회
    • /
    • pp.47-48
    • /
    • 2018
  • The aim of the research is to suggest the compensating strength values depending on various managing periods of concrete based on the strength development model calculated with equivalent age method for OPC 100 % concrete. As a result, for 28 days of managing period, 6, and 3 MPa of compensating strength values were suggested when the temperatures were from 4 to 9℃, from 9 to 17℃, respectively. Additionally, for 42 days of managing period, 3MPa of compensating strength value was suggested when the temperature was from 4 to 10℃, and for 56 days of managing period, 3 MPa of compensating strength value was suggested when the temperature was from 4 to 5℃. Furthermore, for 28, 42, 56, and 91 days of managing periods, any compensating strength values were needed when the temperature were higher than 17, 10, 5, and 4℃, respectively.

  • PDF

미분 시멘트의 치환율 변화가 콘크리트의 역학적 특성에 미치는 영향 (Effect of the Replacement of Fine Particle Cement on Mechanical Properties of the Concrete)

  • 최성용;노동현;김경민;박상준;권오봉;한민철
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2007년도 추계 학술논문 발표대회
    • /
    • pp.133-136
    • /
    • 2007
  • This study investigates mechanical properties of the concrete using fine particle cement which is manufactured by the pulverizing process. The variable factors are 3 types of W/C such as 40, 50, and 60%, 3 types of curing temperature such as 5, 20, and $35^{\circ}C$, and 5types of the replacement of the fine particle cement such as 0, 25, 50, 75, and 100%. The unit water content, S/a and amount of the SP and AE agents to secure the slump and air content is gradually increased in accordance with amount of replacement. It can be confirmed that the delay of the setting time depending on FC content is decreased corresponding to FC content, so the effect of the acceleration to the setting time is expected. The compressive strength corresponding to FC content is proportionally increased, and the growth is confirmed about $30{\sim}40%$ at a day in 50% of FC contents. However, the increase of the strength is gradually decreased in accordance with increasing age.

  • PDF

발파진동이 양생 콘크리트의 물성에 미치는 영향 (Effects of Blasting Vibrations of Physical Properties of Curing Concrete)

  • 정동호
    • 자연, 터널 그리고 지하공간
    • /
    • 제1권1호
    • /
    • pp.81-87
    • /
    • 1999
  • Effects of blasting vibrations on curing concrete have not been well studied. As a result, unrealistic and costly blasting vibration constraints have been placed on blasting when it occurs in the vicinity of curing concrete. To study the effects of blasting, concrete blocks of $30\times20\times20cm$ were molded and placed on the quarry Different sets of concrete blocks were subjected to peak vibrations of 0.25, 0.5, 1.0, 5.0, and 10cm/sec. The impulses of blasting vibrations were applied at thirty minutes intervals . Along with unvibrated concrete blocks, the vibrated concrete samples with 60.3mm in diameters were measured for elastic moduli, sonic velocity and uniaxial compressive strength. Test results can be summarized as follows : 1) The blasting vibrations between 6 and 8 hours after pour generally have exerted bad influences on the uniaxial compressive strength of the concrete 2) Under low vibration of 0.25cm/sec variations of the uniaxial compressive strength were not shown. As the magnitudes of blasting vibration increased, compressive strength of concrete decreased. But under the vibrations between 5 and 10cm/sec decreases in strength were almost same. 3) Physical properties of the p-wave velocity, Young's modulus, and Poisson's ratio appeared to decrease for the concrete blocks subjected to vibration for 6 to 8 hours.

  • PDF

증기양생 콘크리트 표면상태에 대한 박리제의 영향 사례연구 (A Case Study for Influence of Form-oil on Surface Condition of Steam-cured Concrete)

  • 한상훈;윤주용;홍기남;최재완;임준우
    • 한국안전학회지
    • /
    • 제28권1호
    • /
    • pp.52-56
    • /
    • 2013
  • The purpose of this study is to evaluate the influence of form-oil on steam-cured concrete surface condition. Based, viscosity(high, medium, low) and flash point($26^{\circ}C$, $70^{\circ}C$) of form oil were considered as test variables. The digital image process method was applied for the extraction of air-void area from concrete surface. Test result showed that oil-based form oil reduced air-void by approximately 46% compared to water-based form oil, and the higher the viscosity was, the smaller air-void rate was. In addition, it was conformed that flash point of form oil had a considerable influence on the surface condition of steam-cured concrete.

열선 매입과 열선 및 버블시트 조합의 개량형 버블시트를 포설한 슬래브 콘크리트의 온도이력 특성 (Temperature History of the Slab Concrete applying Revised Bubble Sheet with Heating Cable)

  • 정은봉;안상구;정상현;고경택;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2013년도 추계 학술논문 발표대회
    • /
    • pp.23-25
    • /
    • 2013
  • In this study, the results are compared with the case of the concrete with embedded heating wire to verify the performance of the IB made in order to improve the workability and affordability, and to determine the effectiveness of early frost damage prevention. The IB was made using the 5W heating wire and layed on the upper surface of the concrete. The temperature was reduced to below 0℃ approximately within 24 hours, then approached the external temperature thereafter. On the other hand, when the 20W heating wire was used to make the IB and applied the same way, the temperature remained around -2 to 3℃ on the average even through the temperature was reduced to below 0℃, due to the heating wire with relatively large heating capacity. It appeared to reach 85% of the direct heating by embedding the heating wire relatively deeper in the concrete. However, it was determined that using the IB made with the 20W heating wire will prevent the early frost damage to some degree in -10℃.

  • PDF

-10℃ 조건에서의 열선 열용량 크기 변화에 따른 슬래브 콘크리트의 온도이력 특성 (Characteristics of Temperature History of Slab concrete by the Change of Hot wire Heat Capacity at -10℃)

  • 정은봉;안상구;정상현;고경택;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2013년도 춘계 학술논문 발표대회
    • /
    • pp.75-77
    • /
    • 2013
  • In this study, the characteristics of temperature history was evaluated for three hot wires with different capacity installed in slab concrete which are relatively thin. Results can be summarized as follows. First, for the case of material using 5W hot wire, all decreased to below zero at or around 24 hours. Similarly, the material using 20W hot wire decreased to 2℃ below zero at or around 80 hours but satisfied the accumulative temperature of 45° D·D at 7 days of material age. On the other hand, the case of 30W hot wire, the biggest capacity, showed the high temperature history of 5℃ in average at all areas except the corners. Thus, the target accumulative temperature was secured at or around the 3 days of material age. Considering the above, the initial damage by freezing can be prevented only if 20W or higher hot wires are used for the slabs at -10℃ of extremely low temperature environment.

  • PDF

시멘트페이스트 경화체의 Self-Healing 특성에 미치는 구체방수재의 영향 (A Study on Influences of Waterproofing Admixtures for Concrete on Self-Healing Properties of Hardened Cement Paste)

  • 김재영;변승호;마상준
    • 콘크리트학회논문집
    • /
    • 제20권1호
    • /
    • pp.109-116
    • /
    • 2008
  • 본 연구는 시멘트계의 self-healing 반응에 대한 정보와 콘크리트용 구체방수재가 self-healing에 미치는 영향에 대한 정보를 얻기 위하여 수행되었다. 우선 시멘트페이스트를 준비하여 7, 14, 28일간 양생한 다음 분쇄하여 두께가 1 mm 이하인 시편을 분리하였다. 분리한 시편은 밑면과 윗면을 젖은 헝겊으로 감싼 다음 용기에 담아 7일, 28일간 보관하였다. 그 후 젖은 헝겊으로 덮어 두었던 시편을 대상으로 아세톤을 사용하여 수화 정지 작업을 한 다음 XRD, DSC, SEM, EDX를 사용하여 분석하였다. 이러한 분석 결과 시멘트의 self-healing에 대한 정보를 얻을 수 있었다. 시멘트는 self-healing의 특성을 가지고 있으며 이러한 현상은 물의 존재에 큰 영향을 받게 된다. 또한 self-healing은 수화 초기에 더욱 빠르고 효과적인데, 이는 수화 초기 일수록 미반응 시멘트 성분의 함량이 높아 추가적인 수화반응을 일으키기가 수월하기 때문이다. 또한 연구 결과 콘크리트용 구체방수재가 시멘트계의 self-healing에 상당한 영향을 미치는 것을 확인하였다. 구체방수재는 시멘트의 self-healing 효과를 증대시켜주며, 특히 C 구체방수재를 사용한 시편에서는 침상 또는 섬유상의 수화생성물이 다량 존재하는 것으로 나타났으며, 이들 상은 에트린자이트로 예상되어진다. 이들 수화생성물이 시멘트계의 self-healing 효과를 증진하는데 매우 효과적인 것으로 판단된다.