• 제목/요약/키워드: 콘덴서

검색결과 384건 처리시간 0.026초

액티브 공진 콘덴서를 이용한 소프트 스위칭형 PWM 전력변환기에 관한 연구 (A study on PWM power conversion system by soft switching type using active resonant condenser)

  • 곽동걸;이현우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.174-176
    • /
    • 2003
  • The power conversion system must be increased switching frequency in order to achieve a small size, a light weight and a low noise. This paper proposes a skillful and a concise PWM DC-DC converter employing both zero voltage and zero current high frequency switching(ZVCS) operation. The Proposal ZVCS circuit is composed with resonant circuit using active resonant condenser. And this circuit provides switches with ZVS and ZCS by quasi resonant only that switching transients appear. This operation results in reduction of stress and losses in the power devices and resonant components. Some simulation results are included to confirm the validity of the analytical results.

  • PDF

계통 연계형 권선형 유도발전기의 동작특성 연구 (Study on the Operating Characteristics of Double Fed Induction Generator Connected AC network)

  • 김찬기;한상열;추진부
    • 전력전자학회논문지
    • /
    • 제11권3호
    • /
    • pp.247-257
    • /
    • 2006
  • 본 논문은 이중여자권선을 갖는 권선형 유도발전기와 농형유도발전기사이의 운전특성비교를 보여준다. 농형유도발 전기는 자화리액턴스에 의한 무효전력소비 때문에, 역률을 보상하기 위한 콘덴서를 필요로 하나, DFIG는 회전자에 Back-To Back컨버터를 가지고 있기 때문에 저속/고속에서 유도발전기가 운전이 가능하다. 본 논문에서는 PSCAD/TMTDC를 이용하여 농형유도기와 DFIG의 응답특성이 분석되었다.

알루미늄전해콘덴서의 가속수명시험에 관한 실험연구 (An Experimental Study on Accelerated Life Testing for Aluminum Electrolytic Capacitors)

  • 김흥진;전호성;김성득;박영택;진홍기;박찬웅
    • 품질경영학회지
    • /
    • 제23권4호
    • /
    • pp.128-147
    • /
    • 1995
  • An accelerated life testing(ALT) for aluminum electrolytic capacitors is conducted and analyzed. A testing equipment, which consists of part fixtures, relay board, controller, video bridge and microcomputer, is made for the ALT. Load factors are temperature with four levels and voltage with three levels. Base on 'optimized 4:2:1 plan', 2,000 electrolytic capacitors are allocated at 12 experimental conditions(; 4 levels of temperature ${\times}3$ levels of voltage), and the ALT is conducted. From the experimental results, an acceleration model is derived and acceleration factors are estimated. A discussion on the experimental results is included.

  • PDF

염료감응형 태양전지의 축전지로 사용되는 전기이중층콘덴서에 대한 연구 (Studies of electric double layer capacitors used for a storage battery of dye sensitized solar cell energy)

  • 최진영;이임근;홍지태;김희제
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2005년도 제17회 워크샵 및 추계학술대회
    • /
    • pp.673-676
    • /
    • 2005
  • To design the effective usage of electric double layer capacitors (EDLCs) used for a storage device of dye sensitized solar cell(DSC) energy, we first investigated the accumulation state of electrical charges and the charge behavior in the EDLCs. Based on the results. the voltage characteristics of EDLCs connected to DSC energy were evaluated. The results showed that the charge accumulation region concentrated on central part of the carbonaceous electrode in EDLCs and the required times for charging and discharging were almost the same.

  • PDF

공진 콘덴서 분할형 유도가열 전원장치 (Resonant capacitor with separate4 Induction heating system)

  • 이봉섭;민병재;김동희;노채균;정성균;이복규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 A
    • /
    • pp.502-504
    • /
    • 1994
  • This paper describes an induction heating system which is full-bridge parallels resonant inverter. This system consists of current-fed type inverter, and a parallels resonant circuit with a matching transformer. A parallels resonant scheme is employed, and operating range of the proposed circuit with operating frequency and load parameter is demonstrated from the result of steady state. Also, this equipments testing result introduces, good efficiency and reliability of the system. Finally, this paper experimental results are given.

  • PDF

초고압 차단기용 코일건 타입 조작기의 기술적 타당성 검토 (Feasibility Study of Coil Gun Type Actuator for High Voltage Circuit Breaker)

  • 조주현;이홍식;김석환;김영배;이우영;김홍규
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제55권7호
    • /
    • pp.367-372
    • /
    • 2006
  • A novel coil gun type actuator has been proposed and tested for its possibility as an actuator for a high voltage circuit breaker by experimental method. The 20kJ capacitor bank with the electrolytic condensers was charged up to 500V and discharged to a couple of 100 turn coils connected with parallel through a thyristor switch. The repulsive force between coil and the actuator made by copper conductor of 20kg reached up to 23,000 N, and over 800J of energy was transferred to the kinetic energy of the conductor. The experimental results showed that the coil gun type actuator has a good possibility for the high voltage circuit breaker.

고조파 전류원에 의한 콘덴서 임피던스 특성 해석 (Analysis of Impedance Performance for Condenser by Harmonic Current Source)

  • 김종겸;박영진
    • 조명전기설비학회논문지
    • /
    • 제25권4호
    • /
    • pp.57-64
    • /
    • 2011
  • Most of the user has been used linear load and non-linear load. The former is usually inductive load which is needed power factor compensation, the latter is power conversion system device. Actually two kinds of load is used together in the customer application. Generally capacitor is used for power-factor compensation of inductive load and reduction harmonics of non linear load with reactor. Non-linear load generates harmonic current for its energy conversion process. If harmonic current pass along the low impedance side of distribution system, the magnification of voltage and current is appeared by the series and parallel resonance. As a result, condenser has received a bitter electrical stress by the harmonic component. In this paper, we analyzed that how resonance is changed by the 5-th harmonic current pattern and proposed an alternative plan for non-magnification.

Phase-shifted FB-ZVS PWM 스위칭을 이용한 Micorwave oven 구동회로 설계 (A Design of Driving Circuit for Microwave oven using Phase-shifted FB-ZVS PWM Switching)

  • 이완윤;정교범;신판석
    • 전력전자학회논문지
    • /
    • 제6권3호
    • /
    • pp.265-272
    • /
    • 2001
  • 기존의 전자레인지의 마그네트론 구동용 전원장치는 성층 철심을 사용한 60[Hz]고압 변압기, 큰 용량의 콘덴서와 싸이리스터를 이용한 위상제어 회로를 사용하기 때문에 부피가 크고 무거우며, 저효율의 단점을 가지고 있다. 본 논문은 출력 600[W]마그네트론을 장착한 전자레인지의 전원장치로 최대출력1[kW], 스위칭 주파수20[kHz]의 Phase-shifted Full-Bridge(FB)Zero-Voltage-Switched(ZVS) PWM 컨버터의 사용을 제안하고, 이를 개발.적용하여 전체 시스템의 경량화 및 고전력밀도의 목적을 달성하였다.

  • PDF

인버터 승강기 시스템의 고조파 실태 분석 (An Analysis of Harmonics on Inverter Elevator System)

  • 김정태;이기홍;홍규장
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제8권5호
    • /
    • pp.41-48
    • /
    • 1994
  • 국내에서 제작된 인버터 승강시 시스템의 고조파 발생량을 분석하고 타 전기설비에 미치는 영향을 알아보기 위하여 고층 아파트와 빌딩에 설치된 인버터 승강기를 대상으로 고조파 전압·전류를 측정하였다. 그 결과 인버터 승강기 시스템의 총고조파 전압 왜형율은 작게 나타났으나, 총고조파 전류 왜형율은 상당히 큰 것으로 밝혀졌다. 공동주택의 전기설비에 미치는 영향으로는, 역률 개선용 콘덴서에는 큰 문제가 되지 않으나 비상 발전기를 고려하여 인버터 승강기 시스템의 고조파 발생량을 줄일 필요가 있는 것으로 나타났다. 또한, 비상발전기의 허용 %등가역상전류와 본 연구의 실측값을 고려하여 인버터 승강기 시스템의 고조파 전류 규제값을 총고조파 전류 왜형율 40% 이하가 되도록 권장값을 제안하였다.

  • PDF

변압기를 이용한 저가형 단일형 PDP 구동회로에 대한 연구 (A study of simple PDP driver architecture using the transformer network)

  • 김우섭;신종원;채수용;현병철;조보형
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2007년도 추계학술대회 논문집
    • /
    • pp.63-65
    • /
    • 2007
  • 본 논문에서는 변압기를 이용한 단일형 전력회수회로 및 구동 회로를 제안한다. 제안된 회로는 변압기를 이용하여 회수 콘덴서 대체 및 다이오드를 제거하여 전력회수회로를 단순화 한다. 양전원을 이용하여 기존 구동회로의 소거방전시 필요한 주 경로상 직렬 단방향 스위치도 제거된다. 모의 실험을 통해 이용하여 제안된 회로의 타당성을 검토한다.

  • PDF