• Title/Summary/Keyword: 코일상수

Search Result 34, Processing Time 0.034 seconds

Development and Construction of low Magnetic Field Control System for Analysis of Magnetic Field Effect in the Deflection Yoke (브라운관의 자기장 영향 분석용 저자기장 제어 장치의 설계 및 제작)

  • Park, Po-Gyu;Kim, Young-Gyun;Shin, Suk-Woo;Choi, Hyung-Ho;Kim, Tae-Ik;Jung, Dong-Keun
    • Journal of the Korean Magnetics Society
    • /
    • v.13 no.6
    • /
    • pp.251-256
    • /
    • 2003
  • We have developed the quality analysis system for magnetic field effect of cathode-ray tube that is used a monitor, TV and medical appliance. We designed and constructed the large 3-axis square coil (2 m length) system for the generation of 3-component magnetic field using power supply, magnetometer and computer below 0.2 mT range. The coil constant is 30.31 ${\mu}$T, 29.73 ${\mu}$T and 30.51 ${\mu}$T for the X, Y and Z axis square coil respectively. The magnetic field resolution was 0.01 T. The uniformity of magnetic field was measured within 1 % in the range of 12 cm.

Design of Electromagnetic Moving-coil type Voice Coil Motor for Scanning mirror of Barcode reader (바코드 리더용 스캐닝 미러를 위한 무빙 코일 타입 VCM 설계)

  • Shin, Bu Hyun;Lee, Jeong Woo;Shim, Hyun Ho;Park, Sang Goo;Lee, Seung-Yop
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.40 no.1
    • /
    • pp.17-22
    • /
    • 2016
  • A voice coil actuator with moving coil type for scanning mirror system of barcode reader has been developed. The actuator has a simple structure including a magnet, a coil and a pin. The performance of the actuator is analyzed by a linearized theoretical model. And the dynamic performance of the proposed actuator is predicted through motor constant and restoring constant obtained by finite element simulations. The theoretical model was verified by the prototype which has 64 Hz resonance frequency and 60 deg reflecting angle. We also discovered that that 3 V input can make the actuator rotate over 61.8 deg reflecting angle at 50 Hz resonance frequency. The proposed actuator can simplify its driving configuration because of its implementation of open-loop control.

Analytical and Experimental Study for Development of Composite Coil Springs (복합재 코일스프링 개발을 위한 수치해석 및 실험적 연구)

  • Oh, Sung Ha;Choi, Bok Lok
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.1
    • /
    • pp.31-36
    • /
    • 2014
  • This paper shows the feasibility of using carbon-fiber-reinforced polymer (CFRP) composite materials for manufacturing automotive coil springs. For achieving weight reduction by replacing steel with composite materials, it is essential to optimize the material parameters and design variables of the coil spring. First, the shear modulus of a CFRP beam model, which has $45^{\circ}$ ply angles for maximum torsional stiffness, was calculated and compared with the test results. The diameter of the composite spring was predicted to be 17.5 mm for ensuring a spring rate equal to that when using steel material. Finally, a finite element model of the composite coil spring with $45^{\circ}$ ply angles and 17.5 mm wire diameter was constructed and analyzed for obtaining the static spring rate, which was then compared with experimental results.

Design of Rotating Moving-Magnet-Type VCM Actuator for Miniaturized Mobile Robot (소형 이동 로봇을 위한 회전형 보이스 코일 구동기 개발)

  • Shin, Bu Hyun;Lee, Seung-Yop;Lee, Kyung-Min;Oh, Dongho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.37 no.12
    • /
    • pp.1529-1534
    • /
    • 2013
  • A voice coil actuator with a rotating moving magnet has been developed for a miniaturized mobile robot. The actuator has simple structure comprising a magnet, a coil, and a yoke. Actuator performance is predicted using a linearized theoretical model, and dynamic performance based on the air-gap between the magnet and the coil is predicted using motor constant and restoring constant obtained through finite element simulations. The theoretical model was verified using a prototype with 60 Hz resonance and 80 Hz bandwidth. We found that an input of 1.5 V can make the actuator rotate by $20^{\circ}$ statically. The driving configuration of the proposed actuator can be simplified because of its implementation of open-loop control.

Construction of an Earth's Field Compensation System for the Mcasurement of. Proton Gyromagnetic Ratio (양성자 자기회전비율 측정을 위한 지자장 상쇄장치 제작)

  • 우병칠;박포규;김철기;유권상;김창석
    • Journal of the Korean Magnetics Society
    • /
    • v.2 no.2
    • /
    • pp.156-162
    • /
    • 1992
  • In the measurement of proton gyromagnetic ratio by a low field cechnique, the compensation of earth's field is required to keep a zero-field space. The constant earth's fild is compensated by a cur-rent flowing through a Helmholtz coil, whereas small time-varying component is compensated automatically by a closed loop of feedback system. A feedback amplifier, and two three-dimensional Helmholtz coils having the same coil constant have been constructed in order to compensate the earth's field. field. Preliminary test performed at the ordinary laboratory showed that the time-vary-ing field of ${\pm}100nT$ and the constant field have been reduced to the level of ${\pm}10nT$ using the compensating system.

  • PDF

Design of High Efficiency Differential Electromagnetic Type Transducer for Implantable Middle Ear System (이식형 인공중이 시스템을 위한 고효율 차동 전자 트랜스듀서의 설계)

  • Song, Byung-Seop;Ro, Chul-Kyun;Kim, Myoung-Nam;Cho, Jin-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.11 no.3
    • /
    • pp.171-182
    • /
    • 2002
  • The differential electromagnetic transducer for IME(implantable middle ear) system, which have two small permanent magnets glued with the same pole facing each other in the coil, has high vibration efficiency and does not influenced by external magnetic field. In this paper, using finite element method, highly efficient structure of the transducer was proposed and vibration force of the transducer was calculated by electromagnetic theory. And the necessary vibration force of transducer to transmit the sound signal to inner ear when the transducer is attached at stapes was calculated and the design parameters of the transducer were investigated. Using the parameters, the differential electromagnetic transducer was manufactured in small size to implant in confined human middle ear. And it was examined by unloaded and loaded vibration experiment using temporal bone sampled from cadaver.

Method of a current stabilization by using magnetic field (자기장을 이용한 전류 안정화 방법)

  • Park, Po-Gyu;Kim, Young-Gyun;Kim, Wan-Seop
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.619_620
    • /
    • 2009
  • 본 논문은 자기장을 이용하여 전류를 안정화시켜 정밀전류를 발생 시킬 수 있는 장치에 관한 연구이다. 일반적으로 전류를 안정화 시키는 방법은 전류회로에 직렬로 저항을 연결하여 저항 양단에 유도되는 전압을 측정하여 전류를 제어하는 방법을 많이 사용한다. 그러나 이 방법은 정밀한 전류를 제어하기 위하여 직렬로 연결되는 저항값이 커야하며, 또한 전류에 의해 발생되는 열로 인해 저항값이 증가하기 때문에 정밀한 제어가 어렵다. 이러한 단점을 보완 할 수 있는 방법으로 전류회로에 직렬로 코일을 연결하여 전류가 변화면 코일속에 자기장이 변화는 원리를 이용하여 전류를 안정화시켜 정밀전류를 발생 할 수 있다. 본 연구에서는 저자기장 국가표준 확립 및 물리고유상수인 양성자 자기회전비율 측정을 위해 원자자기공명 방법을 이용하여 직류전류를 1 A 범위에서 $0.1{\mu}A$ 수준으로 안정화 시켰다.

  • PDF

The Experiment of the persistent current operation characteristics using Bi-2223 HTS coil (Bi-2223고온 초전도 코일의 영구전류 운전특성 실험)

  • 최세용;나완수;김정호;주진호;하홍수;오상수
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2002.02a
    • /
    • pp.291-293
    • /
    • 2002
  • In this paper, we fabricated a persistent current mode magnet using Bi-2223 HTS tapes. The coil system consists of double pancake magnet and a persistent current switch and jointed them with solder. Persistent current mode operation of the system was measured experimentally by the decay behavior of the current. We found that resistive component of the system including flux flow resistance lead the exponentially field decay with time.

  • PDF

Stability Against Heat Pulse for Bi-2223 HTS Pancake Coils with Different Ag/SC Ratio (은비가 다른 Bi-2223 고온초전도 팬케이크 코일의 히트펄스에 대하 안정성)

  • 장현만;오상수;하홍수;하동우;류강식;김상현
    • Progress in Superconductivity and Cryogenics
    • /
    • v.1 no.2
    • /
    • pp.43-48
    • /
    • 1999
  • The normal zone propagation (NZP) velocity and V-I characteristics of two Bi-2223 pancake coils with different Ag/SC ratio were investigated based on the experimental results and broad resistive transition were obesved in two coils. The measured NZP velocity of coil was found to be faster due to increase of Ag/SC ratio, and agree well with calculated data from two dimensional heat balance equation.

  • PDF

Quench Properties of Bi-2223 Pancake Coils with Different Ag/SC Ratio (은비가 다른 Bi-2223 팬케이크 코일의 ?치 특성)

  • 장현만;오상수;하홍수;하동우;장국렬;류강식;김상현
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 1999.02a
    • /
    • pp.109-112
    • /
    • 1999
  • The normal zone propagation (NZP) velocity and V-I characteristics of two Bi-2223 pancake coils with different Ag/SC ratio were investigated by experiment. Non-uniformity of Ic and broad restive transition was oberserbed in two coils. The NZP velocity of azimuth direction is faster than radius direction, and the NZP velocity of coil with higher Ag/SC ratio is faster than another coil with lower Ag/SC ratio.

  • PDF