• Title/Summary/Keyword: 코로나 전류

Search Result 54, Processing Time 0.027 seconds

Analysis of the Ionized Fields around HVDC Transmission Line by the Use of the Charge Simulation Method (전하중첩법을 이용한 직류 송전선 주변 이온장 해석)

  • Min Suk-Won;Song Ki-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.6 no.6
    • /
    • pp.478-485
    • /
    • 2005
  • This paper analysed the ionized fields around HVDC transmission line by the use of the charge simulation method. As this is very complex and expressed by a non-linear partial differential equations, it is hard to solve problems analytically. So, we developed a computer program which can apply in multi-polar HVDC transmission line with conductor bundles and calculated conductor surface gradient, corona current density and ion charge density to prove validity of a proposed algorithm in this paper.

  • PDF

A Study on an Ion Wind Created by a Wire Electrode and Parallel Plates Assembly (와이어 전극과 평행판에서 발생되는 이온풍 특성 연구)

  • 안영철;황필재;이재근
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.4
    • /
    • pp.318-323
    • /
    • 2004
  • When a strong electric field is applied between a sharply curved electrode and a blunt surface, the corona may result in a gas movement in the electrode gap which is directed toward the blunt surface. That is called the corona wind. It enhances heat and mass transfer between the surface and the surrounding gas. Moreover such enhancement causes no noise or vibration, which can be applied in complex, isolated geometries, and allows simple control of surface temperatures. This paper examines the relationship between the corona wind and the relative humidity. The facility consists of high voltage power supply thin tungsten wire, plate electrode, multimeter, microammeter and flow meter. Gas velocity is a linear function of voltage, relative humidity and is proportional to the square root of the current. The maximum velocities for the positive and negative corona discharge are 1.9 m/s (2.74 CMM/m), 1.5 m/s(2.15 CMM/m), respectively.

A Study on the Charging and discharging current of corona charged Teflon-FEP film (코로나 대전된 Teflon-FEP의 충.방전 전류 특성에 관한 연구)

  • Cheong, Ki-Seok;Lee, Seung-Woo;Park, Kwang-Hyun;Lee, Deok-Chul
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1988.05a
    • /
    • pp.60-62
    • /
    • 1988
  • In this study, the characteristic of charging current which flows into the polymer by applying the corona discharge carriers on the polymer surface was measured, so as to investigate the phenomenon of charge injection and movement if injected charge on polymer. Also. the characteristics of discharge current which flows by shorting both sides of corona charged polymers were measured. Experimental results are as follows; The amount of charges injected by corona discharge vary according to the state of surface and the type of carriers, and then the charging current varies according to the properties of injected carriers.

  • PDF

Thermally Simulated Current of Corona-Charged PVDF Film (코로나 대전된 PVDF 필름의 열자격 전류)

  • Kim, C.H.;Kim, G.Y.;Hong, J.W.;Lee, J.U.
    • Proceedings of the KIEE Conference
    • /
    • 1987.11a
    • /
    • pp.489-491
    • /
    • 1987
  • It has been shown that the thermally stimulated current technique can be one of the most powerful methods for evaluating the electrical properties. An unstretched $\alpha$-form specimen of corona-charged, 50[${\mu}m$],t Polyvinylidene Fluoride shows four TSC peaks designated $\delta}$, $\gamma$, $\beta$ and $\alpha$ in assending order of temperature in temperature range $-100{\sim}200^{\circ}C$. The $\delta$, $\gamma$ peaks may be attributed to the dipolar depolarization in the amorphous regions and $\beta$, $\alpha$ peaks are associated with the detrap from trapped carriers in the crystalline regions.

  • PDF

광폭 전기집진기의 집전특성에 관한 연구 - I. 집진판 간격과 방전극의 영향 -

  • 김용진;하병길;정상현;홍원석;여석준;유주식
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.10
    • /
    • pp.939-946
    • /
    • 2001
  • This study investigates the electrical and collection characteristics of a wide plate spacing electrostatic precipitator (ESP), using a pilot-scale one. Electrical operating characteristics and collection efficiency were measured for various shapes of discharge electrodes. The collection plate spacing ranged from 300 to 550 mm. Results of electrical characteristic and collection efficiency tests as a function of collection plate spacing, discharge electrode type, applied voltage, and particle diameter were obtained. Increasing the collection plate pitch and altering the corona electrode geometry was found to increase the collection efficiencies without increasing input power requirement. The best efficiency is achieved for the discharge electrode of twisted pin type.

  • PDF

Experimental Study on the Discharge Electrode of A Two-Stage Electrostatic Air Cleaner (2단 평행판 전기집진기의 방전부 특성 실험)

  • Kim, I.S.;Lee, J.O.;Kim, Y.J.;Choi, H.O.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.5 no.1
    • /
    • pp.27-34
    • /
    • 1993
  • The two-stage electrostatic air cleaner is a particle control device that uses electrical forces to move particles in the flowing gas stream onto collector plates. Despite a general understanding of electrostatic air cleaner operation and their successful use in industry, many questions regarding flow, electric fields and particle collection have remained unanswered. In this paper, an experimental investigation for designing the discharge electrode, including ionizer wire diameter, plate length and wire-to-plate spacing, is carried out. The electrical conditions, namely the electric field intensity, the space current and the particle charge intensity, in wire-plate electrostatic air cleaner are reported and examined.

  • PDF

A Study on the Automatic Measurement of Salt Contamination Degree (염분오손도 자동측정 방법에 관한 연구)

  • Kang, Y.W.;Jang, T.I.;Jung, S.C.;Yang, B.M.;Kang, J.W.;Jo, S.B.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.2138-2140
    • /
    • 2000
  • 송전선, 변전소, 발전소 등의 전력설비에 있어서 애자장치의 오손은 지락사고나 코로나 유발에 의한 환경장애 등의 원인이 되고 있어 염분에 의한 애자장치의 오손 대책이 설비 관리에 있어서 중요한 부분을 차지하고 있으며, 이를 위해서는 염분 오손도의 측정이 선행되어야 한다. 본 논문에서는 염분 오손도를 상시 자동으로 측정할 수 있는 방법으로서 제안되고 있는 전자식 애자 이용법, 열전 반도체를 이용한 전도도 측정법, Nd:YAG 레이저법, 레이저 광센서와 프리즘을 이용한 염분 오손도 측정법, 정전용량 검출센서를 이용한 염분 오손도 측정법, 백금 전극을 이용한 누설전류 측정법과 같은 염분 오손도 측정법을 소개하고자 한다.

  • PDF

Resonant DC-DC Converter for High Voltage Supply of Electric Desiccant Oil Flushing System (전기흡착식 오일 플러싱 시스템의 고전압원을 위한 공진형 DC-DC 컨버터)

  • Kim, Myungbok;Oh, Kwangkyo
    • Proceedings of the KIPE Conference
    • /
    • 2015.07a
    • /
    • pp.151-152
    • /
    • 2015
  • 산업용으로 사용되는 전기흡착식 오일 플러싱 시스템에 코로나 방전층을 형성하기 위해서 10kV이상의 고전압원이 필요하다. 현재 전기흡착식 오일 플러싱 시스템을 위한 고전압원으로 고전압 변압기와 다이오드 정류 방식을 사용되고 있으나 변압기 구동을 저주파로 구동하므로 시스템의 크기 줄이는데 제약이 있다. 이러한 무게와 부피를 저감하기위한 다른 방식으로는 고주파의 하프 브릿지 컨버터와 2차단의 전압 더블러 방식을 채택하는데 이 방식의 경우 앞단의 스파이크성 전류로 인하여 다이오드의 발열 문제가 심각하다. 이러한 문제점을 해결하기 위해서 LC 공진형 컨버터를 제안하였으며 컨버터의 설계 또한 제시하였다. 이러한 설계와 제안된 컨버터의 효용성을 검증하기 위해서 최대 출력 150W와 출력전압 15kV의 시작품을 제작하여 실험을 실행하였다.

  • PDF

A Study on the Collection Characteristics of a Moving Electrode Electrostatic Precipitator - I. Effect of Collection Plate Velocity - (이동 전극형 전기집진기의 집진특성에 관한 연구 - I. 집진판 이동 속도의 영향-)

  • Kim Yong-Jin;Ha Byung-Kil;Jeong Sang-Hyun;Moon Sang-Cheol;Yoo Joo-Sik
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.10
    • /
    • pp.901-907
    • /
    • 2004
  • This study investigate the effect of collection plate velocity on the electrical and collection characteristics of a moving electrode electrostatic precipitator (MEEP). Though a high resistivity fly ash is attached at the collecting electrode, the MEEP has very stable characteristics of voltage and corona current. Collection efficiency, corona current, and overall collection efficiency are increased, as the magnitude of the collection plate velocity increases.

Performance characteristics of low frequency pulsating voltage power supply for DC Plasma Electric Precipitator (고전압 플라즈마 전기집진기를 위한 고전압 저속 스위칭의 작동 특성)

  • Jeong, Ku Young;Jeon, Hyeong Geun;Oh, Hyeon Jun;Roh, Chung Woook
    • Proceedings of the KIPE Conference
    • /
    • 2019.07a
    • /
    • pp.174-176
    • /
    • 2019
  • 최근 미세먼지(PM10 또는 PM2.5)로 인한 인체 유해성 및 실제 피해사례가 인터넷, TV 매체 등에 의해 화두가 됨에 따라 각종 제조, 사업장 및 발전소에서는 미세먼지 배출기준을 충족하기 위한 고효율 집진 기술이 필요로 되고 있는 상황이다. 고압 코로나 방전에 의해 미세먼지를 포집하는 고전압 하전방식 집진장치의 경우 전류를 광범위로 조절 가능하며 역전리 방지에 탁월하여 고효율의 집진이 가능하다. 본 논문에서는 기존의 다전원(펄스전원, 기본전원)을 이용한 마이크로 펄스 하전방식이 아닌 공진형 컨버터와 고압 트랜스포머, 배전압 회로를 적용한 고전압 단전원 제어 하전방식 및 이를 이용한 고전압 전압원의 저속 스위칭 제어기법을 제안하고, 실제 측정을 통해 제안 방식의 실효성을 검증하였다.

  • PDF