• Title/Summary/Keyword: 컴퓨터 단층 영상

Search Result 376, Processing Time 0.021 seconds

Development of CT/MRI based GUI Software for 3D Printer Application (3차원 프린터 응용을 위한 CT/MRI-영상 기반 GUI소프트웨어 개발)

  • Jung, Young-Jin
    • Journal of radiological science and technology
    • /
    • v.41 no.5
    • /
    • pp.451-456
    • /
    • 2018
  • During last a decade, there has been increased demand for 3D-printed medical devices with significant improvement of 3D-Printer (also known as Additive. Manufacturing AM), which depend upon human body features. Especially, demand for personalized medical material is highly growing with being super-aged society. In this study, 3D-reconstructed 3D mesh image from CT/MRI-images is demonstrated to analyse each patients' personalized anatomical features by using in house, then to be able to manufacture its counterpart. Developed software is distributed free of charge, letting various researcher identify biological feature for each areas.

Multilevel Dumbbell Tumor of the Posterior Mediastinum -1 Case Report- (다범위 종격동 Dumbbell종양 - 1례 보고 -)

  • 허동명;김병호;조재훈;강동기
    • Journal of Chest Surgery
    • /
    • v.32 no.8
    • /
    • pp.768-771
    • /
    • 1999
  • A 45 year old man was admitted for further examination of an abnormal shadow of the right posterior mediastinum. The patient suffered from dysesthesia in the right thoracic wall of dermatome T7. CT scan and MRI revealed that two separate tumors had developed in the right paravertebral area linked to the vertebral canal via an intervertebral foramina. One-stage removal of the tumors were performed safely through the right posterolateral thoracotomy following the resection of the rib head and vertebral pedicle. The tumors were confirmed as histologically neurilemomas. The postoperative course was uneventful.

  • PDF

Study of Ultrasonic 3-Dimensional Image Reconstruction (초음파를 이용한 3차원 영상 재구성에 관한 연구)

  • 안승옥;홍기상
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.18 no.2
    • /
    • pp.54-63
    • /
    • 1981
  • An ultrasonic imaging system with fan reflection mode time of fight is developed and its performance has been examined by system implementation. Experimental results obtained indicafe potential of the method for tomographic imaging. The basic concept of this method is reconstruction of reflectivity with reflection data collected in fan mode using a new "arbitrary ray" reconstruction algorithm. Computer simulations as well as experimental results are presented.presented.

  • PDF

Computer-aided Design and Fabrication of Bio-mimetic Scaffold for Tissue Engineering Using the Triply Periodic Minimal Surface (삼중 주기적 최소곡면을 이용한 조직공학을 위한 생체모사 스캐폴드의 컴퓨터응용 설계 및 제작)

  • Yoo, Dong-Jin
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.28 no.7
    • /
    • pp.834-850
    • /
    • 2011
  • In this paper, a novel tissue engineering scaffold design method based on triply periodic minimal surface (TPMS) is proposed. After generating the hexahedral elements for a 3D anatomical shape using the distance field algorithm, the unit cell libraries composed of triply periodic minimal surfaces are mapped into the subdivided hexahedral elements using the shape function widely used in the finite element method. In addition, a heterogeneous implicit solid representation method is introduced to design a 3D (Three-dimensional) bio-mimetic scaffold for tissue engineering from a sequence of computed tomography (CT) medical image data. CT image of a human spine bone is used as the case study for designing a 3D bio-mimetic scaffold model from CT image data.

A Study on Various Automatic Exposure Control System in Multi-Detector Computed Tomography by Using Human Phantom (인체 모형을 이용한 다중 검출기 컴퓨터단층촬영기기의 다양한 자동노출제어 시스템에 대한 연구)

  • Kim, Yong-Ok;Seoung, Youl-Hun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.4
    • /
    • pp.1714-1720
    • /
    • 2012
  • The purpose of the study was to evaluation of the radiation dose reduction and the possibility of the maintainability of the adequate image quality using various automatic exposure control (AEC) systems in multi-detector computed tomography (MDCT). We used three AEC systems for the study: General Electric Healthcare (Auto-mA 3D), Philips Medical systems (DoseRight) and Siemens Medical Solutions (Care Dose 4D). The general scanning protocol was created for the each examination with the same scanning parameters as many as possible. In the various AEC systems, the evaluation of reduced-dose was evaluated by comparing to fixed mAs with using human phantom. The image quality of the phantom was evaluated with measuring the image noise (standard deviation) by insert regions of interests. Finally, when we applied to AEC for three manufacturers, the radiation dose reduction decreased each 35.3% in the Auto-mA 3D, 58.2% in the DoseRight, and 48.6% in the Care Dose 4D. And, there was not statistical significant difference among the image quality in the Strong/Weak of the Care Dose 4D(P=.269). This applies to variety of the AEC systems which will be very useful to reduce the dose and to maintain the high quality.

A Study of Various Filter Setups with FBP Reconstruction for Digital Breast Tomosynthesis (디지털 유방단층영상합성법의 FBP 알고리즘 적용을 위한 다양한 필터 조합에 대한 연구)

  • Lee, Haeng-Hwa;Kim, Ye-Seul;Lee, Youngjin;Choi, Sunghoon;Lee, Seungwan;Park, Hye-Suk;Kim, Hee-Joung;Choi, Jae-Gu;Choi, Young-Wook
    • Progress in Medical Physics
    • /
    • v.25 no.4
    • /
    • pp.271-280
    • /
    • 2014
  • Recently, digital breast tomosynthesis (DBT) has been investigated to overcome the limitation of conventional mammography for overlapping anatomical structures and high patient dose with cone-beam computed tomography (CBCT). However incomplete sampling due to limited angle leads to interference on the neighboring slices. Many studies have investigated to reduce artifacts such as interference. Moreover, appropriate filters for tomosynthesis have been researched to solve artifacts resulted from incomplete sampling. The primary purpose of this study is finding appropriate filter scheme with FBP reconstruction for DBT system to reduce artifacts. In this study, we investigated characteristics of various filter schemes with simulation and prototype digital breast tomosynthesis under same acquisition parameters and conditions. We evaluated artifacts and noise with profiles and COV (coefficinet of variation) to study characteristic of filter. As a result, the noise with parameter 0.25 of Spectral filter reduced by 10% in comparison to that with only Ramp-lak filter. Because unbalance of information reduced with decreasing B of Slice thickness filter, artifacts caused by incomplete sampling reduced. In conclusion, we confirmed basic characteristics of filter operations and improvement of image quality by appropriate filter scheme. The results of this study can be utilized as base in research and development of DBT system by providing information that is about noise and artifacts depend on various filter schemes.

Unusual Cardiac Metastasis of Nonvisceral Soft Tissue Leiomyosarcoma in the Right Ventricle: A Case Report and Literature Review (우심실로 전이된 내장 외 연부조직 평활근육종: 증례 보고 및 문헌 고찰)

  • Sangmin Park;Heekyung Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.1
    • /
    • pp.219-224
    • /
    • 2021
  • Leiomyosarcoma (LMS) is a soft tissue sarcoma that originates from smooth muscle cells. It is commonly found in the uterus but can occur throughout the body, including the retroperitoneal space, abdominal cavity, and any vascular structure. Although there are many case reports of uterine or vascular LMS metastasizing to the heart, cardiac metastasis from nonvisceral lesions has only been reported in two cases. Herein we report a rare case of a patient presenting metastatic LMS from the left flank in the right ventricle observed with echocardiography and enhanced computed tomography.

Unusual Peritoneal Metastasis of Late Recurrent Uterine Cervical Cancer: A Case Report and Literature Review (후기 재발성 자궁 경부암의 비전형적인 복막 전이: 증례 보고 및 문헌 고찰)

  • Sangmin Park;Hee Jin Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.4
    • /
    • pp.904-909
    • /
    • 2022
  • Uterine cervical cancer is one of the most common malignancies of the female genital tract. Most recurrent cases of uterine cervical cancer are diagnosed within two years after primary treatment, and late recurrence after a disease-free interval of more than five years is rare. In addition, peritoneal metastases usually present as multifocal discrete nodules in the peritoneal cavity with nodular or diffuse peritoneal thickening. Herein, we report an extremely rare case of late recurrent cervical cancer peritoneal metastasis with an unusual manifestation of a large, solitary necrotic mass in the right subphrenic space on contrast-enhanced CT.

Time efficiency and operator convenience of using a micro-screw in image registration for guided implant surgery (마이크로스크류가 가이드 임플란트 수술을 위한 영상정합 과정에서 작업시간과 술자편의성에 미치는 영향)

  • Mai, Hai Yen;Lee, Du-Hyeong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.3
    • /
    • pp.219-224
    • /
    • 2019
  • Purpose: The image registration of radiographic image and digital surface data is essential in the computer-guided implant guide system. The purpose of this study was to examine the effects of using micro-screw on the working time and convenience of operators in the process of image matching for guided implant surgery. Materials and methods: A mandibular dental model was prepared in partial edentulism for Kennedy class I classification. Two micro-screws were placed on the each side of retromolar area. Radiographic and scan images were taken using computed-tomography and digital scanning. The images were superimposed by 12 operators in software in two different conditions: using remaining teeth image alone and using teeth and micro-screws images. Working time, operator convenience and satisfaction were obtained, and analyzed using the Mann-Whitney U test (${\alpha}=.05$). Results: The working time was not statistically different between image registration conditions (P>.05); however, operator convenience and satisfaction were higher in the teeth and micro-screw assisted condition than in the teeth-alone assisted condition (P<.001). Conclusion: The use of micro-screw for the image registration has no effect in working time reduction, but improves operator convenience and satisfaction.

Atypical Manifestation of Primary Hepatocellular Carcinoma and Hepatic Malignancy Mimicking Lesions (원발성 간세포암의 비특이적 영상 소견 및 간암으로 오인될 수 있는 병변에 대한 영상의학적 고찰)

  • Jiyoung Yoon;So Hyun Park;Su Joa Ahn;Young Sup Shim
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.4
    • /
    • pp.808-829
    • /
    • 2022
  • Hepatocellular carcinoma (HCC) can be diagnosed noninvasively on multiphasic CT and MRI based on its distinctive imaging findings. These features include arterial phase hyperenhancement and washout on portal or delayed phase images. However, radiologists face significant diagnostic challenges because some HCCs exhibit atypical imaging characteristics. In addition to many HCC-mimicking lesions, such as arterioportal shunts, combined HCC-cholangiocarcinoma, intrahepatic cholangiocarcinoma, and hemangioma present a challenge for radiologists in actual clinical practice. The ability to distinguish HCCs from mimickers on initial imaging examinations is crucial for appropriate management and treatment decisions. Therefore, this pictorial review presents the imaging findings of atypical HCCs and HCCs mimicking malignant and benign lesions and discusses important clues that may help narrow down the differential diagnosis.