• Title/Summary/Keyword: 컨트롤 밸브

Search Result 123, Processing Time 0.031 seconds

A Study on PID Control Law's Realization for 2-Stage Proportional Pressure Control Valve with Analog Controller (아날로그 PID 제어기를 이용한 2단 비례 압력 제어 밸브의 실현에 관한 연구)

  • Yun, S.N.;Jeong, H.H.
    • Journal of Drive and Control
    • /
    • v.9 no.4
    • /
    • pp.58-61
    • /
    • 2012
  • The customers who used the hydroulic system desire the product that has more detailed specification quickly during the industrial technology is developed. Every researcher try to reduce the developed period and to satisfy the customers' desire. Lot's of simulation software and hardware already was used to be satisfied those purpose. But these kind of equipment need a lot of cost to set up and technical knowledge to drive that system. This paper concerns about analog PID controller that can be assembled with a few resistor, condenser and optional amplifier and doesn't need technical knowledge to drive. At the first, the plant was modeled mathematically to design the analog PID controller's circuit. After that, PID controller's parameter was selected by customers' desire. Finally, the analog PID controller's circuit was assembled from the control law. The circuit's availability was confirmed by step response test in the controlled system.

Development of Performance Test Equipment for Easy-Hill Assist Valve (EHA 밸브 성능시험 장치 개발)

  • Jung, G.H.
    • Journal of Drive and Control
    • /
    • v.11 no.4
    • /
    • pp.61-67
    • /
    • 2014
  • When a manual transmission equipped car stops on an incline where the nose of the car is higher than the rear, hill-start control or hill-holder could prevent the vehicle from rolling backward as the car moves forward. The easy-hill assist valve consists of a check valve and a needle type ON/OFF solenoid valve connected in parallel; it is a hydraulic actuator that can maintain brake pressure using an electrical signal from the ECU. As the EHA valve is a safety-related component of the brake system, high reliability as well as superior dynamic performance is required for it to be applied in commercial vehicles. This paper presents the design of the EHA valve as a piece of equipment that can simulate the brake actuation pressure with a pressurizing piston. Following specific test standards, the experimental results validate the implemented functions of the test equipment, proving the test stand to be effective for the performance and endurance of the EHA valve.

Analysis of Characteristics of Load Movement in Mobile Hydraulic Equipment (모바일 유압장치에서 부하의 유지와 내림 특성 비교)

  • Jo, Mi Hyeon;Huh, Jun Young
    • Journal of Drive and Control
    • /
    • v.15 no.4
    • /
    • pp.17-22
    • /
    • 2018
  • Mobile hydraulics require higher energy efficiency, and a simpler as well as robust design, than general industrial hydraulics. The 6/3-way directional control valve is widely used as a mobile hydraulic control valve. However, since the 6/3-way directional control valve is a spool type valve, it is difficult to maintain the load. A counterbalance valve is typically used, to maintain the load, and lift down. However, in an industrial field using a mobile hydraulics device, a pilot controlled check valve may be used to implement holding and lifting operation of the self-weight load, and a relief valve may be used simply to exert back pressure. But no comparative analysis of advantages and disadvantages of each method was revealed. In this study, various methods of holding and unloading load with self-weight in mobile hydraulics are investigated, and compared through simulation using AMESim software. This is experimentally verified by using Festo's mobile hydraulic test rig TP800.

A Fundamental Study on Offshore Structures of high pressure control valve (해양구조물용 고압 컨트롤 밸브에 대한 기초 연구)

  • Lee, Chi-Woo;Jang, Sung-Cheol
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.19 no.6
    • /
    • pp.883-888
    • /
    • 2010
  • This study have goal with conceptual design for Offshore Structures of high pressure control valve for localization. Ball valve for development accomplished with flow analysis based on provision of ANSI B16.34, ANSI B16.10, ANSI B16.25 In order to localize the Offshore Structures high pressure control valve. Numerical simulation using CFD (Computational Fluid Dynamic) in order to predict a mass flow rate and a flow coefficient form flow dynamic point of view. The working fluid assumed the glycerin (C3H8O3). The valve inlet and outlet setup a pressure boundary condition. The outlet pressure was fixed by atmospheric pressure and calculated until increasing 1bar to 10bar. CFD analysis used STAR-CCM+ which is commercial code and Governing equations were calculated by moving mesh which is rotated 90 degrees when ball valve operated opening and closing in 1 degree interval. The result shows change of mass flow rate according to opening and closing angle of valve, Flow decrease observed open valve that equal percentage flow paten which is general inclination of ball valve. Relation with flow and flow coefficient can not be proportional according to inlet pressure when compare with mass flow rate. Because flow coefficient have influence in flow and pressure difference. Namely, flow can be change even if it has same Cv value. The structural analysis used ANSYS which is a commercial code. Stress analysis result of internal pressure in valve showed lower than yield strength. This is expect to need more detail design and verification for stem and seat structure.

A Study on the Development of Electric Actuator Control Device for Driving Time Setting Valve Using VHDL (VHDL을 이용한 구동 시간 설정 밸브 전동 엑추에이터 제어 장치 개발에 관한 연구)

  • Kang, Dae-Guk;Choi, Young-Gyu
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.13 no.5
    • /
    • pp.452-459
    • /
    • 2020
  • The electric actuator receives the user's command input signal (open/closed/stop), checks the status of various sensors (valve position, rotational force, motor status, etc.)in the actuator, and controls the motor forward/reverse to open and close the valve. It is a device that outputs the current state of an actuator (valve) and is used in various fields such as dams, power plants, water and sewage facilities, and oil pipeline facilities. If an electric actuator is installed in a power plant and a problem occurs during operation, it can cause a large economic loss, so system reliability is vert important. In this study, in order to increase the safety of the electric actuator, the development of an electric actuator control device capable of setting the ON/OFF time in hardware was conducted to solve the reliability problem that may occur in software. In addition, the electric actuator control device development environment was developed using Xilinx's Spartan7 FPGA and Altium tool.

Trajectory Control of Excavator Actuators Using IMV (IMV를 이용한 굴착기 작업장치 궤적제어)

  • Jung, Gyuhong
    • Journal of Drive and Control
    • /
    • v.17 no.2
    • /
    • pp.45-54
    • /
    • 2020
  • The IMV is a combination of four two-way valve systems which replace a conventional four-way spool valve to improve efficiency mostly in excavator hydraulics. As the environmental regulations for construction equipment have tightened, some overseas advanced companies have released commercial excavators in which the MCV is implemented with the IMVs. Development of the IMV type MCV relies on the control algorithm as well as the robust performance of proportional flow control valves. In this study, the IMV controller was designed and verified with experiments for the excavator working unit, which determines the IMV mode of operation and the extent of the valve opening in consideration of the load conditions on hydraulic actuators. First, the open-loop controller was designed with a joystick command vs. a PSV reference current map comprising several control parameters in to compensate for the different flow characteristics and non-linearities of two-way flow control valves. Second, the closed-loop controller was designed with the PI control fed by the actuator displacement and outputs actuator percent effort equivalent to the operator's joystick command. Finally, the performance of the IMV type MCV was verified with the trajectory control of position references derived from the energy consumption test standard. Experimental results showed the control performance of the IMV developed in this study, and suggest that future studies to be conducted to advance technical progress.

A Study on the Reliability Improvement of the Turbine Control Valve System in Nuclear and Thermal Power Plants (원자력/화력발전소의 터빈제어밸브시스템의 신뢰성 향상에 관한 연구)

  • Yang, Jong Dae;Yang, Seok Jo;Lee, Yong Bum
    • Journal of Drive and Control
    • /
    • v.16 no.4
    • /
    • pp.93-100
    • /
    • 2019
  • Nuclear and thermal power plants must provide the turbines with an appropriate degree of high temperature and high pressure steam, to produce the optimum electricity. Additionally, in the event of system and power system failure during electrical production, the steam is immediately disabled, to protect the turbines and generators rotating at high speed. The plant thus uses a special steam control valve system for turbine control, which is opened by force of the hydraulic servo actuator and closed by a large steel spring force. In this study, the causes of failure of the turbine control valve system, a key device of the power plants, were analyzed, and the causes of failure were improved relative to reliability of the equipment.

A Study on the Improvement of Flow Characteristics of the Glove Valve for Compressible Fluid (압축성 유체용 글로브 밸브의 유량특성 향상에 관한 연구)

  • Bae, Ji Won;Chung, Woo Young;Jang, Ji Seong
    • Journal of Drive and Control
    • /
    • v.16 no.4
    • /
    • pp.32-37
    • /
    • 2019
  • Glove valves are used for various purposes in the process control field because such valves enable easy control of temperature and pressure. However, such valves are associated with significant loss of pressure and also have the disadvantage of complicating the shape of the cage or plug to facilitate linear flow rate change. In this paper, the shape of the plug, one of the valve flow control elements, was designed to improve the flow characteristics of the glove valve, and then CFD analysis was performed using compressible fluid. The numerical analysis results of the glove valve were analyzed according to the opening ratio and the pressure ratio of the valve. From these results, it was found that the proper notch on the side of the plug contributed to reducing the energy loss of the fluid through the valve and improving the linearity of the valve.

Safety Estimation of High Pressure Drop Control Valve for Offshore Structures (해양플랜트용 고압.고차압 제어밸브의 구조 안전성 평가)

  • Kim, Jae-Woong
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.20 no.5
    • /
    • pp.553-558
    • /
    • 2011
  • This study have goal with conceptual design for offshore structures of high pressure drop control valve for localization valve for development accomplished with flow analysis based on provision of ANSI B16.34, ANSI B16.10, ANSI B16.25. In order to localize the Offshore structures high pressure drop control valve. This study is numerical analysis for zambil offshore project of high pressure drop control valve. The solver which ANSYS workbench used for offshore structures analysis. The working fluids assumed the glycerin(C3H8O3). The structural analysis used ANSYS which is a commercial code. Stress analysis result of internal pressure in valve showed lower than yield strength. This is expect to need more detail design and verification for stem and disk structure. In this study a multi-disk of high pressure drop control valve is designed and manufactured. Then, the flow rate and high pressure dorp of fluids flowing in the high pressure drop control valve is CAE. So, this system can be easily substituted for the existing zambil offshore project system. Finally, safety estimation for trim design of high pressure drop control valve for offshore structures.

System Design and Fundamental Experiment for Thrust Control of $GO_2$/PE Hybrid Rocket ($GO_2$/PE 하이브리드 로켓의 추력제어를 위한 시스템 설계 및 기초실험)

  • Lee, Yong-Wu;Kang, Wan-Kyu;Huh, Hwan-Il
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.14 no.1
    • /
    • pp.40-47
    • /
    • 2010
  • In this study, basic research on the thrust control by controling oxidizer mass flow rate of a $GO_2$/PE hybrid rocket is presented. For this purpose, hybrid rocket system including oxidizer flow control system and data acquisition system was developed. To control oxidizer mass flow rate, we used needle valve with stepping motor which was controled by LabVIEW program. During the fundamental experiments, this system managed to follow the pre-programmed (20 N - 10 N - 20 N - 0 N) thrust level.