• Title/Summary/Keyword: 커프

Search Result 29, Processing Time 0.022 seconds

A study on the reduction of crosstalk in a two-dimensional planar array of underwater acoustic transducers (2차원 평면배열 수중 음향 트랜스듀서 내 상호간섭 저감 방안 연구)

  • Park, Haejune;Roh, Yongrae
    • The Journal of the Acoustical Society of Korea
    • /
    • v.35 no.5
    • /
    • pp.349-357
    • /
    • 2016
  • In this work, we proposed various structural methods to reduce the crosstalk between elements in a planar array of underwater acoustic transducers and investigated the efficacy of each method through finite element analysis. It is shown that the effects of crosstalk reduction increase as the depth of the kerf among elements and the width of the kerf increase, and the elastic stiffness of the kerf filler decreases. Results of this study are expected to be useful in designing the structure of underwater acoustic planar array transducers to maximize their performance.

A Study on the Cross Talk Level in a Piezoelectric Ultrasonic Array Transducer (압전형 초음파 배열 변환기의 음향간섭 레벨에 관한 연구)

  • 이수성;김영신;노용래
    • The Journal of the Acoustical Society of Korea
    • /
    • v.21 no.1
    • /
    • pp.56-61
    • /
    • 2002
  • In piezoelectric ultrasonic linear array transducers widely used for diagnosis, the cross talk caused by the structural cross-coupling between adjacent elements inside the transducer affects the probe performance in a significant manner. In this study, we constructed a finite element model of a piezoelectric ultrasonic transducer, and analyzed its cross talk level with respect to the shape of and materials inside the kerf, The results of this work can be utilized in optimal design of the transducers for medical diagonosis and treatment as well as W applications.

A Study on the Cross Talk Level in a Medical Piezoelectric Ultrasonic Array Transducer (의료용 압전 초음파 배열 변환기의 음향간섭 레벨에 관한 연구)

  • Kim Young-Shin;Roh Yongrae
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • spring
    • /
    • pp.349-352
    • /
    • 2002
  • 초음파 진단용으로 널리 사용되는 1차원 배열 압전형 초음파 변환기는 변환기내의 인접한 소자들간의 간섭에 의해 그 특성에 많은 영향을 받는다. 특히 각 소자 사이에 위치한 커프 및 음향 벽의 형상은 변환기 내 음향 간섭에 매우 큰 영향을 미친다. 그러므로 본 연구에서는 일반적으로 복부진단용으로 사용되는 압전형 1차원 배열 의료용 초음파 변환기에서 커프 및 음향 벽의 형상에 따른 음향간섭 레벨의 변화 경향을 유한 요소 해석법을 이용하여 분석하였다. 해석 결과를 바탕으로 소자간 음향간섭을 일으키는 원인을 규명하고, 나아가 음향 간섭레벨을 최소화하기 위한 구조적 방안을 도출하였다. 이러한 연구 결과는 향후 진단용 초음파 변환기의 최적 설계를 위해 중요한 자료가 될 것이며, 의료 치료용, 비파괴 검사용, 그리고 수중 초음파 변환기에도 적용이 가능할 것이다.

  • PDF

Trachea Necrosis after Thyroidectomy ; Case Report and Review (갑상선절제술 후 발생한 기도 괴사 ; 증례보고)

  • Choi, Ji Woo;Lee, Jeonghun;Song, Youngpeck;Kim, Chul-Ho;Soh, Euy Young
    • Korean Journal of Head & Neck Oncology
    • /
    • v.30 no.2
    • /
    • pp.109-114
    • /
    • 2014
  • 갑상선절제술은 내분비 외과의사가 하는 수술 중 가장 안전한 수술이지만 수술 중 기도나 식도가 손상 받을 수 있으므로 각별한 주의를 기울여야 한다. 특히 기도 괴사와 같이 생명에 위협을 주는 합병증이 있음을 유념해야 한다. 본 논문은 갑상선 전 절제술과 승모판 치환술을 함께 받은 72세 여성환자가 수술 후 3일만에 기도 괴사가 발생한 케이스이다. 3개의 기관륜에 걸쳐 괴사가 발생되어 있었다. 괴사된 조직을 제거하고, 이후 지속적인 괴사조직에 대한 제거와 치료와 적으로 기관개창술을 시행하고, 자연폐쇄를 유도하여 성공적으로 치료되었다. 비슷한 여러 논문들을 살펴본 결과 기도 괴사를 유발하는 요인으로는 조절되지 않는 기침, 여성, 갑상샘중독 결절, 기도 삽관 시 발생되는 손상, 삽관튜브 커프의 과팽창으로 기도가 장시간 높은 압력으로 압박되었을 때, 적절하기 않은 커프 크기, 삽관튜브 커프의 공기를 빼지 않고 무리하게 움직였을 때, 출혈이 많을 때, 과도한 전기소작으로 인한 손상, 기도로 가는 혈관손상으로 인한 혈액공급의 차단, 감염 등으로 보고 있다. 치료는 기도의 괴사와 감염의 정도에 따라 달라질 수 있다. 일차 봉합술, 일시적 스토마 형성, 일시적 기관조루술, 단단연결술, 기도 스텐트 설치술, 근육피판 재건술, 보존적 치료 등을 시행할 수 있다. 기도 괴사에 대한 위험인자와 치료에 대해서는 아직 확실히 적립되지 않은 상태이다. 드문 합병증이지만 생명을 위협할 수 있는 이러한 합병증에 대해 항상 염두 해 두고 수술 시 신중을 기하고 문제 발생시 신속한 대응을 해야겠다.

Design of the Blood Pressure Measurement System Using the Inflatable Oscillometric Method (가압식 오실로메트릭 방법을 사용한 혈압측정 시스템의 설계)

  • 노동곤;이윤선;지정호;박성빈;이계형;김해관
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.4
    • /
    • pp.281-286
    • /
    • 2003
  • Blood Pressure is one of the most fundamental Parameters which reflects physical conditions medically and the blood pressure measurement system using oscillometric method is a Non-Invasive Blood Pressure measurement device by measuring arterial Pressure through a cuff. In this paper. we designed a inflatable wrist blood pressure system which measures blood Pressure during the stepping inflation in the wrist cuff. The hardware system consists of a main power unit, a bladder in cuff unit, signal detection units, signal Processing units. a wireless data transmission unit, and a data display unit. We evaluated the reliability of this system by comparing and analyzing systolic. diastolic blood Pressure, and heart rate with other commercial blood Pressure measurement devices. Characteristic ratio values used to determine systolic and diastolic blood Pressure using MAA(Maximum Amplitude Algorithm) were 0.436 and 0.671 respectively.

Interactive G$^1$ Splines with Tangent Specification Method (접선 지정법을 이용한 대화형 G$^1$스플라인)

  • Ju, U-Seok;Park, Gyeong-Hui;Lee, Hui-Seung
    • The Transactions of the Korea Information Processing Society
    • /
    • v.1 no.4
    • /
    • pp.531-540
    • /
    • 1994
  • Spline curve scheme is the most valuable tool for the CAD of industrial products. Hence, the development of a new, effective curve scheme can have immediate impact on the current design industries. This paper develops and implements a new methodology for the implementation of the visually continuous class of splines which can produce a more flexible and diverse curve shapes. This class of splines has advantaged over existing splines in that it can accommodate wider range of shapes while maintaining the interpolators property of the ordinary cardinal splines. Most importantly, we avoid using the previous method of implementing G$^1$ curves, where users must specify scalar values for the control of curve shapes. We derive and implement an easy-to -use transformation between the user-specified graphical tangent vectors and the actual parameters for the resulting curve. Since the resulting curve shape reflects original tangential direction faithfully, CAD users can simply represent approximate curve shapes with proper tangents. Consequently, a simple user interface device such as a mouse can effectively produce a various spline curves using the proposed spline tool.

  • PDF

15 channel tonometric radial pulse measurement system using air cuff pressure (공압 가압 방식의 15채널 맥파 측정 시스템)

  • Kim, Eun-Geun;Heo, Hyun;Nam, Ki-Chang;Huh, Young
    • Proceedings of the KIEE Conference
    • /
    • 2008.10b
    • /
    • pp.205-206
    • /
    • 2008
  • 한의학에서 손목의 맥파를 손으로 짚어 보고 파형의 변화로써 병변의 원인을 파악하는 것은 기본적인 진단 방법이다. 진단을 위해 요골동맥의 촌, 관, 척 세 부위의 맥파를 수지를 통해 일정 가압을 하며 맥의 깊이, 강약, 빠르기 등을 촉진을 통해 맥상을 분석한다. 본 연구에서는 촌, 관, 척 부위를 동시 측정하기 위해 각 부위에 5개의 압력센서 어레이가 적용된 15채널 맥진기를 구성하였다. 또한 요골 동맥 부위에 적정 가압을 유지하기 위해 공기 커프를 이용한 공압 가압 방식을 적용하였다. 본 가압 방식을 통해 요골 동맥 부위에 연속적이며 정밀 가압제어가 가능하였다.

  • PDF

Development of Blood Pressure Measurement Method Using ANFIS (ANFIS를 이용한 전자 혈압 측정 알고리즘 개발)

  • Kwon Seok-Young;Lee Dae-Jong;Chung Myung-Geun
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2006.05a
    • /
    • pp.219-222
    • /
    • 2006
  • 본 논문에서는 ANFIS를 이용한 전자혈압계 측정알고리즘을 제안한다. 이를 위해 본 연구에서는 우선, 기존의 팔뚝형 커프와 수동 공기주입기 방식의 전자혈압 측정시스템을 구축하여 혈압 신호를 실시간으로 취득하였다. 다음단계로 취득된 실시간 혈압신호를 이용하여 최고혈압과 최저 혈압을 측정하기 위해 MAA(Maximum Amplitude Algorithm) 기법을 이용한다. 그러나, MAA기법은 개인의 특성을 고려하지 않고 일정한 비율을 고정시키므로 정확한 혈압을 측정하는데 한계가 있다. 따라서, 본 논문에서는 MAA에 의해 측정된 최고혈압과 최저혈압을 ANFIS를 이용하여 학습시키므로서 이러한 문제점을 해결하고자 한다. 제안된 알고리즘의 효율성을 보이기 위해 다양한 혈압신호에 대해 실험한 결과 기존의 MAA에 의한 방법보다 향상된 결과를 나타냈다.

  • PDF

Blood Pressure Cuff Bladders Tailored For Koreans (한국인 맞춤형 혈압계 커프 블래더)

  • Hwang, Lark Hoon;Park, Woo Sung;Na, Seung Kwon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38C no.9
    • /
    • pp.822-829
    • /
    • 2013
  • Hypertension is one of the most common clinical diseases, with an increasing prevalence globally. Hypertension triggers various harmful consequences and affects multiple organs. Life-long care may be required in some cases. According to the Korea Center for Disease Control and Prevention, the prevalence of hypertension is gradually increasing. A 2011 survey revealed that 28.9% of Korean adults had hypertension. The prevalence rates were slightly higher among men than women. Accurate measurement of blood pressure(BP) is crucial to classify patients, to identify BP-related risks, and to inform correct treatment. For accurate blood pressure measurement, the use of a cuff bladder size appropriate for the mid-upper arm circumference(MUAC) is essential. Incorrect sized cuff bladder is one of the main causes of equipment error affecting sphygmomanometer accuracy. When commercial sphygmomanometers were examined, the cuff bladders differed from the dimensions specified in the ISO 81060-1:2007 standards. Undercuffing is responsible for a spurious overestimation of BP in patients with large arms leading to overdiagnosis of hypertension, whereas overcuffing (that is, use of relatively large cuffs with small arms), may be responsible for an opposite problem, leading to erroneous underestimation of BP levels. The cuff bladder sizes recommended by the American Heart Association(AHA) are an arm circumference(AC) of 17-25 cm for small-sized adults, AC of 24-32 cm for adults, AC of 32-42 cm for normal-sized adults, and AC of 42-50 cm for obese adults. In contrast, the AC of Korean adults ranges from 23-31 cm, belonging to a single type of adult bladder. Three types of bladders are necessary for Korean adults with an AC of 23-31cm. Hospitals often use one or two differently-sized Western cuffs for adult patients, which can yield inaccurate BP determinations. Cuff bladders with dimensions based on anthropometric reference data obtained from Koreans will aid hospitals to measure BP more accurately.