• 제목/요약/키워드: 커튼 월

검색결과 147건 처리시간 0.024초

초고층 커튼월 공정관리 최적화를 위한 건설성능 데이터 표준화 (Data Standardization of Construction Performance for Optimized Process Management in High-rise Curtain-wall Operations)

  • 이태희;고용호;김영석;한승우
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2012년도 추계 학술논문 발표대회
    • /
    • pp.283-284
    • /
    • 2012
  • High-rise building construction has been increasing for the recent years and the construction process has become more complicated. This suggests a need for precise planning based on reliable data to prevent cost overruns and delays. However, the process planning is implemented based mainly on the experience of engineers that can result in critical damage in cost and time. Accurate productivity estimation and unit cost analysis must be considered important matter to prevent such disaster. This study estimates productivity and unit cost of curtain wall operations in high-rise building construction by simulation techniques and statistical methodologies. This study suggests a decision making methodology for the site personnel that enables to compare various combinations of productivity and unit cost based on reliable data that has been collected in actual construction sites. It is expected that this study contributes to the following research of developing an optimized construction performance assembling model for the site personnel.

  • PDF

열교부위를 고려한 커튼월 사무소 건물의 열성능 해석에 관한 연구 (A Study on the Thermal Performance Analysis of Curtain Wall Office Building Considering the Thermal Bridges)

  • 신우철;김승철;윤종호
    • 한국태양에너지학회 논문집
    • /
    • 제31권3호
    • /
    • pp.95-100
    • /
    • 2011
  • Currently, office buildings in Korea tend to adopt as their outer wall the curtain wall structure which can be easily constructed and has beautiful external appearance as well. However, the problem is that the curtain wall structure does not have a uniform composition unlike the wall of existing reinforced concrete structures and has a frame made of metal with high heat conduction. Therefore, it is expected that the structure will be highly influenced by the thermal bridge. Thereupon, this study analyzes how to set up the composition of the wall system and heat transmission rate in consideration of the thermal characteristics of the curtain wall structure and applies it in practice by simulation in order to propose a guideline for the energy simulation method of the curtain wall structure and analyze its differences from existing simulation methods.

ALC 패널을 활용한 건축물 외장 커튼월에 대한 Mock-up Test 성능 평가 연구 (Performance Evaluations of Mock-up Tests for ALC Panel Curtain Wall in Building Exterior)

  • 김영호;이용수
    • 한국디지털건축인테리어학회논문집
    • /
    • 제13권4호
    • /
    • pp.25-32
    • /
    • 2013
  • The green building is one of biggest factors to go the goal of energy saving and environmental conservation, reduction of energy consumption, friendly energy technology, recycling of resource, and environmental pollution reduction technology. The purpose of these green buildings realized by the energy-saving technology such as the exterior materials or curtain wall system. The curtain wall system is a element that come to insulated portions of building envelope that results in heat loss. The purpose of this paper is to carried out mock-up tests for exterior wall used in autoclaved lightweight concrete panels in green building practices. Mock-up test execute a mixed process between standard test procedure and complex test procedure based on AAMA 501(American Society for Testing and Materials) and ASTM 283, ASTM 330(American Society for Testing and Materials). In results, tests meet the requirements that grant values in steps of procedures provided on ASTM and AAMA. ALC panel is suitable for a exterior wall product to be gratified thermal cycling performance and structural capacity, deflection(H/200) and lateral displacement(H/50), for curtain walls.

프로젝트 단계별 LOD가 반영된 스마트 BIM 커튼월 라이브러리 체계 구축 (Proposal of Smart BIM Library Framework for Curtain Wall with different LOD on each project stage)

  • 김범준;김성아;김병주;진상윤
    • 한국BIM학회 논문집
    • /
    • 제7권2호
    • /
    • pp.44-55
    • /
    • 2017
  • Recently, there has been a growing interest in the life cycle management field of buildings through the introduction of BIM. And as BIM application is expanded, BIM ordering guidelines and guidelines are becoming popular. Also, as diverse forms of buildings including super high-rise building have been generalized, attention to the importance of curtain walls that are advantageous for construction period shortening, building lighting and quality homogenization has been increasing. However, all BIM information from the design stage to the maintenance stage is not accumulated in stages. And the input information is not improved in proportion to the level of appearance of the BIM model. Also, current curtain wall designs rely heavily on curtain wall consulting firms or utilize accumulated data from existing processes. In this study, curtain wall components, shape and property information were derived by analyzing BIM guidelines and curtain wall construction standards to contribute to solving these problems. And the curtain wall smart BIM library which can be converted according to LOD(Level of Development) has been produced and its applicability has been verified. Through the library, curtain wall information can be systematically managed in the library from design to construction and maintenance. And the library will contribute to the expansion and activation of the BIM library market in the future.

초고층 아파트의 커튼월 결로 예측 방법에 관한 연구 (A Study on the Prediction Method of Condensation on the Curtain Wall of the High-rise Apartment Unit)

  • 임정희
    • 건설안전기술
    • /
    • 통권41호
    • /
    • pp.88-101
    • /
    • 2007
  • Recently, the condensation of walls often occurring in domestic high-rise apartment buildings is an important problem. The main purpose of this study is to develop the prediction method for the surface condensation on curtain wall in high-rise apartment buildings. Therefore, in this study, we first analyzed exterior climate factors through the analysis of the Seoul climate data and predicted the change of indoor temperature by using Apache program to find the cause of the condensation state and to prevent condensation. Also, according to this result, exterior climate factors and interior factors, which caused the condensation, was examined. The thermal performance of the curtain wall and the range of potential condensation were analyzed to focus on high-rise apartment buildings through computer simulation programs. The results are as $follows;^1$) The frame edge of curtain wall has a higher U-value than in the center by $30%^2$) Because of stack effect, the rooms on the higher floor have a lower external ventilation rate resulting to a higher relative humidity3) Installing a ventilation system($20m^3$/h. person) makes it possible to have a higher external ventilation rate, resulting to a lower relative humidity.

  • PDF

경량기포콘크리트(ALC) 패널을 건축물 외장 커튼월에 적용을 위한 도료의 기초적 연구 (Applications and Analysis of Exterior Paints for the Curtain Wall Panel System based on the Autoclaved Lightweight Concrete(ALC))

  • 이용수;라현주
    • 한국디지털건축인테리어학회논문집
    • /
    • 제12권3호
    • /
    • pp.59-66
    • /
    • 2012
  • Autoclaved Lightweight Concrete(ALC) features such as a high performance insulation, the fire resistance, the advantage of easy handing construction, and lightweight panels applied the curtain wall system. ALC materials are certified as non-toxic environmental and eco-friendly productions. But ALC external panels mixed with blast furnace slag pounder and silica fume have to be coated with a stucco compound or plaster because of resisting the ambient environment. This study is that mixing tests to evaluate a performance analysis of exterior paints to be make-up pigments(organic or inorganic) coated with panel surface. Testing compared by KS F 2476; flow test, KS F 2426; compression strength test, KS F 2762; bond strength test. In results, the case of the inorganic binder, ratio of alumina cement : anhydrite is 90:10 to 80:20 at the highest level of intensity. In the case of the organic binder, adhesive strength rating at surface of ALC, the pullout strength is below 0.5 $N/mm^2$ but the normal concrete is over 2.0$N/mm^2$. A contents ratio of EVA resin is more than 3% and then bond strength is effectively.

커튼월 사무소용 건물에서 실내발열이 냉난방 부하에 미치는 영향 (The Impact of Internal heat gain on heating and Cooling Load in Curtain Wall Office Buildings)

  • 김정윤;육인수;남현진;이진성;김재민;조수
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.925-930
    • /
    • 2008
  • As office automation appliances and communication equipments are adopted in office buildings, internal heat gains increase gradually. When making simulation model, internal heat gains are usually set up with standard values or ignored. Therefore, the impact of the internal heat gains has been ignored or not been focused although it is recognised as significant contributor to heating/cooling load of buildings. This study focused on the impact of internal heat gains on curtain wall buildings. the amount and schedules of heat internal gains profiles not only affect the profiles of heating/cooling loads, but also make impact on reducing the effectiveness of high performance glazing systems. It is important to identify internal heat gains profiles before considering the installation of high performance glazing systems.

  • PDF

자유형상 커튼월 구현을 위한 3D 프린팅을 활용한 스마트노드 시스템의 연구 (Study on the Connection Node System of Irregular-shaped Curtain wall Facade using 3D Printed Smart Node System)

  • 나상호;유승규;박영미;박정준;김성진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2018년도 추계 학술논문 발표대회
    • /
    • pp.8-9
    • /
    • 2018
  • 3D printing has the unique advantage of the ability to customize freeform product even in small quantity. However, we need to select and apply the only necessary parts of it because of the high cost of the manufacturing technology. It is of critical importance in irregular-shaped curtain walls to ensure precision of construction as well as quality fo finish. Complex shape that have structural members at varying angles can have nodes of different shapes making it unfeasible to construct using a general node connection detail. Therefore, this study aims to utilize smart node system using 3D printing as a solution to complex irregular-shaped curtain wall design.

  • PDF

다 자유도 매니퓰레이터를 이용한 커튼월 시공 자동화에 관한 연구 (A Study of the Automation System using a Multi-DOF Manipulator for the Curtain Wall Installation in a Skyscraper)

  • 유승남;이승열;최현석;이계영;이상헌;한창수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.940-945
    • /
    • 2004
  • Recently, the trend in architectural forms has been toward taller and larger building. The building materials, therefore, are getting larger and heavier as wall. Most of the construction projects are, however, dependent on outdated equipment and human resources. Construction processes up to now face a number of problems, including dangerous work, high construction cost and heterogeneous construction quality. In various construction sites, automation in construction has been introduced to address these problems. This paper proposes a human-machine cooperative system in the construction site; the system utilizes construction of a curtain wall in tall buildings. The use of automation system at construction sites can reduce the need of human involvement. Construction time and cost can be reduced as well. The most important aspect of the use of automation system at construction sites is prevention of accidents.

  • PDF

커튼월 스팬드럴 적용을 위한 CIGS 박막 모듈의 특성 분석 연구 (The Characteristics on CIGS Thin Film PV Module for Curtain Wall Spandrel Applications)

  • 강준구;김준태
    • 한국태양에너지학회 논문집
    • /
    • 제33권3호
    • /
    • pp.107-113
    • /
    • 2013
  • In this study, three different types of experimental models of BIPV curtain wall units with GIGS modules were built, and their thermal and electrical performances were analyzed. The experimental results showed that the temperature of the rear side of the GIGS module with the application of an insulation in the curtain wall spandrels was higher than a GIGS module standalone by $22^{\circ}C$, which results in a reduction in the power generation of the former by 8 %. On the other hand, when ventilation was applied to the model to improve the power generation performance, the module temperature was observed to be $142^{\circ}C$ lower compared to the enclosed type, and the power generation performance improved by 5 %. It confirmed that the temperature increase in the rear side of the GIGS module with insulation layer reduced the electrical performance of the module. Based on this, it is claimed that providing sufficient ventilation at the GIGS applied spandrels contribute to improve the power generation of the GIGS module.