• Title/Summary/Keyword: 커튼

Search Result 314, Processing Time 0.028 seconds

Proposal of Smart BIM Library Framework for Curtain Wall with different LOD on each project stage (프로젝트 단계별 LOD가 반영된 스마트 BIM 커튼월 라이브러리 체계 구축)

  • Kim, Beom-Jun;Kim, Seong-Ah;Kim, Byeong-Ju;Chin, Sang-Yoon
    • Journal of KIBIM
    • /
    • v.7 no.2
    • /
    • pp.44-55
    • /
    • 2017
  • Recently, there has been a growing interest in the life cycle management field of buildings through the introduction of BIM. And as BIM application is expanded, BIM ordering guidelines and guidelines are becoming popular. Also, as diverse forms of buildings including super high-rise building have been generalized, attention to the importance of curtain walls that are advantageous for construction period shortening, building lighting and quality homogenization has been increasing. However, all BIM information from the design stage to the maintenance stage is not accumulated in stages. And the input information is not improved in proportion to the level of appearance of the BIM model. Also, current curtain wall designs rely heavily on curtain wall consulting firms or utilize accumulated data from existing processes. In this study, curtain wall components, shape and property information were derived by analyzing BIM guidelines and curtain wall construction standards to contribute to solving these problems. And the curtain wall smart BIM library which can be converted according to LOD(Level of Development) has been produced and its applicability has been verified. Through the library, curtain wall information can be systematically managed in the library from design to construction and maintenance. And the library will contribute to the expansion and activation of the BIM library market in the future.

A Study on the Prediction Method of Condensation on the Curtain Wall of the High-rise Apartment Unit (초고층 아파트의 커튼월 결로 예측 방법에 관한 연구)

  • Im, Jeong-Hui
    • Journal of the Korea Construction Safety Engineering Association
    • /
    • s.41
    • /
    • pp.88-101
    • /
    • 2007
  • Recently, the condensation of walls often occurring in domestic high-rise apartment buildings is an important problem. The main purpose of this study is to develop the prediction method for the surface condensation on curtain wall in high-rise apartment buildings. Therefore, in this study, we first analyzed exterior climate factors through the analysis of the Seoul climate data and predicted the change of indoor temperature by using Apache program to find the cause of the condensation state and to prevent condensation. Also, according to this result, exterior climate factors and interior factors, which caused the condensation, was examined. The thermal performance of the curtain wall and the range of potential condensation were analyzed to focus on high-rise apartment buildings through computer simulation programs. The results are as $follows;^1$) The frame edge of curtain wall has a higher U-value than in the center by $30%^2$) Because of stack effect, the rooms on the higher floor have a lower external ventilation rate resulting to a higher relative humidity3) Installing a ventilation system($20m^3$/h. person) makes it possible to have a higher external ventilation rate, resulting to a lower relative humidity.

  • PDF

Performance Variation of the Refrigerated Display Case with Air Curtain in Accordance with Back Pressure Condition (배압에 따른 에어커튼형 냉동용 전시케이스의 성능변화)

  • Sung, Sun-Kyung;Ahn, Kyo-Chul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.11
    • /
    • pp.578-584
    • /
    • 2013
  • Vertical open display cases are widely used in shopping malls, supermarkets, or retail stores to sell frozen and refrigerated products. Open display cases use air curtains to maintain a reasonable temperature within the storage space, prevent insects from breaking in, and reduce energy usage. In this research, computational fluid dynamics was used to find the optimal condition for reducing energy by considering various conditions such as discharge speed or temperature of air curtains. Results of the study showed that the amount of energy consumed in the display cabinet is influenced by the discharge speed and temperature of the slots installed on the upper area and the amount of air supplied to the storage area inside the shelf. This shows that the amount of discharged air supplied from the storage area influences the formation of air curtain and also the amount of energy consumption. As a result of this study, we learned that the amount of energy used can be reduced by increasing the amount of discharged air within the storage area and enhancing back pressure.

A Study on Fire Characteristics of Carpet and Curtain Treated or Untreated with Flame Retardant (카페트와 커튼의 방염처리 및 사용여부에 따른 화재특성에 관한 연구)

  • Lee, Hae-Pyeong;Park, Young-Ju
    • Fire Science and Engineering
    • /
    • v.21 no.1 s.65
    • /
    • pp.74-81
    • /
    • 2007
  • In this study, we have evaluated the hazardous factors of fires such as heat release rate, smoke density, ignition temperature, and flammability of carpet and curtain used in the public facilities. As a result of flame retardant treatment, the heat release rate of materials treated with flame retardant was lower than that of not treated. However, the smoke density of treated materials was higher than that of not treated. Also, we have investigated the fire characteristics of used and unused carpet. As a result, the heat release rate and the smoke density of used for 3 years carpet were higher than those of unused carpet. The distinct differences of flammability and ignition temperature between used and unused carpet were confirmed.

Applications and Analysis of Exterior Paints for the Curtain Wall Panel System based on the Autoclaved Lightweight Concrete(ALC) (경량기포콘크리트(ALC) 패널을 건축물 외장 커튼월에 적용을 위한 도료의 기초적 연구)

  • Lee, Yong-Soo;La, Hyun-Ju
    • Journal of The Korean Digital Architecture Interior Association
    • /
    • v.12 no.3
    • /
    • pp.59-66
    • /
    • 2012
  • Autoclaved Lightweight Concrete(ALC) features such as a high performance insulation, the fire resistance, the advantage of easy handing construction, and lightweight panels applied the curtain wall system. ALC materials are certified as non-toxic environmental and eco-friendly productions. But ALC external panels mixed with blast furnace slag pounder and silica fume have to be coated with a stucco compound or plaster because of resisting the ambient environment. This study is that mixing tests to evaluate a performance analysis of exterior paints to be make-up pigments(organic or inorganic) coated with panel surface. Testing compared by KS F 2476; flow test, KS F 2426; compression strength test, KS F 2762; bond strength test. In results, the case of the inorganic binder, ratio of alumina cement : anhydrite is 90:10 to 80:20 at the highest level of intensity. In the case of the organic binder, adhesive strength rating at surface of ALC, the pullout strength is below 0.5 $N/mm^2$ but the normal concrete is over 2.0$N/mm^2$. A contents ratio of EVA resin is more than 3% and then bond strength is effectively.

Isolation Performance of the Single-Sided air Curtain in Air-Conditioned Space (공조공간에서 수평토출형 에어커튼의 차단 성능)

  • Sung, Sun-Kyung
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.11
    • /
    • pp.806-812
    • /
    • 2012
  • Air curtains are widely used in commercial and public buildings to replace solid doors where traffic of people is predicted. At doorways where the solid door is open continuously or intermittently, an air curtain may be installed in order to reduce the flow of heat and moisture from the enclosed space to the outside. The purpose of this paper is to predict isolation performance of the single-sided air curtain when the wind is blowing. For the study, a numerical simulation is used to find the influence of various jet velocities on the efficiency of the single-sided air curtain device which is mounted at the side of the doorway. The isolation performance of the single-sided air curtain is evaluated by sealing efficiency which provides the assessment of the infiltration air ratio. According to the result of this study, the single-sided air curtain has lower sealing efficiency than downward-blowing air curtain. Therefore, for energy conservation in heating space, the single-sided air curtain is not recommended because of its low effectiveness.

The Impact of Internal heat gain on heating and Cooling Load in Curtain Wall Office Buildings (커튼월 사무소용 건물에서 실내발열이 냉난방 부하에 미치는 영향)

  • Kim, Jeong-Yoon;Yook, In-Soo;Nam, Hyun-Jin;Lee, Jin-Sung;Kim, Jae-Min;Cho, Soo
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.925-930
    • /
    • 2008
  • As office automation appliances and communication equipments are adopted in office buildings, internal heat gains increase gradually. When making simulation model, internal heat gains are usually set up with standard values or ignored. Therefore, the impact of the internal heat gains has been ignored or not been focused although it is recognised as significant contributor to heating/cooling load of buildings. This study focused on the impact of internal heat gains on curtain wall buildings. the amount and schedules of heat internal gains profiles not only affect the profiles of heating/cooling loads, but also make impact on reducing the effectiveness of high performance glazing systems. It is important to identify internal heat gains profiles before considering the installation of high performance glazing systems.

  • PDF

A Study on Locally Drying Underwater Welding (국부건식(물커튼식)수중용접법에 관한 연구)

  • 이규복;황선효;박영조;김종열
    • Journal of Welding and Joining
    • /
    • v.10 no.2
    • /
    • pp.51-62
    • /
    • 1992
  • A torch was designed and fabricated in order to develope the technology of "locally drying underwater welding" by water curtain method. The condition for the formation of the possible local cavity, the mechanical properties and the thermal cycle of welds were investigated in the developed welding equipment compared with in-air welding. The possibility of highly reliable and practical underwater welding was found. The proper local cavity was formed above the water flowrate of 30l/min and CO$_{2}$ gas flowrate of 100l/min. The bead width and penetration depth were increased with increasing welding current. The hardness of weldments is about 160Hv in air welding, but about 210Hv in underwater welding. The elongation and the impact value of underwater weldments are 15% and 6Kg/cm$^{2}$ respectively, which are only half as much as the values of in-air welding. The cooling time in the temperature range from 800.deg.C to 500.deg.C affecting the structure and the hardness of weldments is about 22sec. in air welding while about 10sec. in underwater welding.r welding.

  • PDF

Study on the Connection Node System of Irregular-shaped Curtain wall Facade using 3D Printed Smart Node System (자유형상 커튼월 구현을 위한 3D 프린팅을 활용한 스마트노드 시스템의 연구)

  • Na, SangHo;Yoo, SeungKyu;Park, YoungMi;Park, JungJoon;Kim, SungJin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.11a
    • /
    • pp.8-9
    • /
    • 2018
  • 3D printing has the unique advantage of the ability to customize freeform product even in small quantity. However, we need to select and apply the only necessary parts of it because of the high cost of the manufacturing technology. It is of critical importance in irregular-shaped curtain walls to ensure precision of construction as well as quality fo finish. Complex shape that have structural members at varying angles can have nodes of different shapes making it unfeasible to construct using a general node connection detail. Therefore, this study aims to utilize smart node system using 3D printing as a solution to complex irregular-shaped curtain wall design.

  • PDF

A Study of the Automation System using a Multi-DOF Manipulator for the Curtain Wall Installation in a Skyscraper (다 자유도 매니퓰레이터를 이용한 커튼월 시공 자동화에 관한 연구)

  • You, Seung-Nam;Lee, Soung-Yel;Choi, Hyeun-Seok;Lee, Kye-Young;Lee, Sang-Heon;Han, Chang-Soo
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.940-945
    • /
    • 2004
  • Recently, the trend in architectural forms has been toward taller and larger building. The building materials, therefore, are getting larger and heavier as wall. Most of the construction projects are, however, dependent on outdated equipment and human resources. Construction processes up to now face a number of problems, including dangerous work, high construction cost and heterogeneous construction quality. In various construction sites, automation in construction has been introduced to address these problems. This paper proposes a human-machine cooperative system in the construction site; the system utilizes construction of a curtain wall in tall buildings. The use of automation system at construction sites can reduce the need of human involvement. Construction time and cost can be reduced as well. The most important aspect of the use of automation system at construction sites is prevention of accidents.

  • PDF