진동수영역해석법을 이용한 캐비닛내부응답스펙트럼 생성 기법 (In-Cabinet Response Spectrum Generation Using Frequency Domain Analysis Method)

  • 조성국;소기환
    • 한국지진공학회논문집
    • /
    • 제24권2호
    • /
    • pp.103-110
    • /
    • 2020
  • Seismic qualification of instruments and devices mounted on electrical cabinets in a nuclear power plant is performed in this study by means of the in-cabinet response spectrum (ICRS). A simple method and two rigorous methods are proposed in the EPRI NP-7146-SL guidelines for generating the ICRS. The simple method of EPRI can give unrealistic spectra that are excessively conservative in many cases. In the past, the time domain analysis (TDA) methods have been mostly used to analyze a structure. However, the TDA requires the generation of an artificial earthquake input motion compatible to the target response spectrum. The process of generating an artificial earthquake may involve a great deal of uncertainty. In addition, many time history analyses should be performed to increase the accuracy of the results. This study developed a numerical analysis program for generating the ICRS by frequency domain analysis (FDA) method. The developed program was validated by the numerical study. The ICRS calculated by FDA thoroughly matched with those obtained from TDA. This study then confirms that the method it proposes can simply and efficiently generate the ICRS compared to the time domain method.

빌트인 양문형 냉장고의 캐비닛 구조해석 및 도어 상하단차와 앞뒤단차의 평가 (Structural Analysis of Cabinet in Built-in Side-by-Side Refrigerator and Evaluation of Door Height Difference and Door Flatness Difference)

  • 이부윤
    • 한국기계가공학회지
    • /
    • 제17권2호
    • /
    • pp.30-36
    • /
    • 2018
  • Since the freezer compartment and the refrigerating compartment are located side by side in a side-by-side refrigerator, the problems of the door height difference (DHD) and door flatness difference (DFD) have been constantly raised. Deformation of the cabinet of a built-in side-by-side refrigerator under food and thermal loads was analyzed by the finite element software ANSYS. The DHD and DFD, occurring due to the deformation of the cabinet, evaluated. From the results of the analysis of the cabinet, the 3D CAD software CATIA was used to geometrically translate and rotate the freezing and refrigerating compartment doors, in consideration of the displacement of the hinge fastening point. Then, the coordinates of two points on the upper corner of the doors were determined, and the DHD and DFD were obtained. It found that the thermal load, occurring under normal operation conditions, decreases the door height difference, but increases the door flatness difference. Values of the analyzed DHD and DFD appear smaller than the acceptance criteria used by the refrigerator manufacturer.

캐비닛운전원모듈을 위한 사용자인터페이스 스타일가이드 (A User Interface Style Guide for the Cabinet Operator Module)

  • 이현철;이동영;이정운
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.203-205
    • /
    • 2005
  • A reactor protection system (RPS) plays the roles of generating the reactor trip signal and the engineered safety features (ESF) actuation signal when the monitored plant processes reach predefined limits. A Korean project group is developing a new digitalized RPS and the Cabinet Operator Module (COM) of the RPS which is used for the RPS integrity testing and monitoring by an equipment operator. A flat panel display (FPD) with a touch screen capability is provided as a main user interface for the RPS operation. To support the RPS COM user interface design, actually the FPD screen design, we developed a user interface style guide because the system designer could not properly deal with the many general human factors design guidelines. To develop the user interface style guide, various design guideline gatherings, a walk-though with a video recorder, guideline selection with respect to user interface design elements, determination of the properties of the design elements, discussion with the system designers, and a conversion of the properties into a screen design were carried out. This paper describes the process in detail and the findings in the course of the style guide development.

  • PDF

반도체 산업 공정가스의 혼화성에 따른 반응성 고찰 (Reactivity Considerations with Miscibility of Process Gases in Semiconductor industry)

  • 이근원
    • 한국가스학회지
    • /
    • 제20권4호
    • /
    • pp.15-24
    • /
    • 2016
  • 반도체 산업에서 많은 종류의 화학물질 사용으로 인한 독성물질 누출과 화학물질간의 혼화에 따른 화재 폭발 등에 의한 화학사고의 위험성이 증가하고 있다. 화학물질의 혼화에 따른 반응성을 평가하는데 실험적 방법이 가장 신뢰성 있지만, 모든 화학물질을 실험을 통하여 평가하는 것은 시간적, 비용적인 제한이 있다. 본 연구에서는 반도체 산업에서 주로 사용되는 공정가스의 위험성 추정하기 위해 미국 NOAA(National Oceanic and Atmospheric Administration)과 EPA에서 개발한 CRW(Chemical Reactivity Worksheet) 3.0 프로그램을 사용하여 공정가스의 반응성을 고찰하였다. 이들 연구 결과는 반도체산업의 공정가스의 혼화성에 따른 반응성 정보와 저장캐비닛의 가스 실린더 보관에 관한 KOSHA 기술지침 작성에 필요한 기초자료를 제시하고자 하였다.

운행 중 변형형상을 이용한 에어컨 실내기 캐비닛의 소음/진동 특성 파악 및 제어 (Noise, vibration Characteristic Identification and Noise Control of Indoor Air-Conditioner's Cabinet using Operational Deflection Shape)

  • 이성진;오재응;이정윤;강태호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.830-833
    • /
    • 2004
  • An indoor package air-conditioner (PAC) has complex noise sources such as motor noise and fluid noise caused by the fan motor, heat transfer and shroud. Sound intensity techniques and ODS(Operational deflection shape) techniques are applied to identify the noise characteristics of an indoor air-conditioner's cabinet. The sound intensity is used to visualize the noise source locations. and the ODS to visualize the vibration pattern and to obtain the dynamic characteristics of the noise source. Acoustic intensity and operational deflection distribution are obtained in space domains as well as frequency domains. Using the visual information of source locations and its dynamic characteristics, the damping patch is applied to reduce structure borne noise in the cabinet. As a result, the noise emitted by the cabinet is reduced by 5dB.

  • PDF

캐비닛-도어 통합모델을 이용한 빌트인 양문형 냉장고의 도어 상하단차와 앞뒤단차 해석 (Analysis of Door Height Difference and Door Flatness Difference of Built-in Side-by-Side Refrigerator Using Cabinet-Door Integrated Model)

  • 이부윤
    • 한국기계가공학회지
    • /
    • 제17권5호
    • /
    • pp.76-83
    • /
    • 2018
  • A cabinet-door integrated finite element model was constructed for a built-in side-by-side refrigerator with an ice dispenser, and its deformation was analyzed using the ANSYS finite element software. As loads, the food load needed to fill in the cabinet and doors and the thermal load occurring during normal operation conditions were taken into consideration. The door height difference (DHD) and door flatness difference (DFD) between the two doors of the freezing and refrigerating compartments were derived. The DHD and DFD under the assembled condition without applied loads satisfied the acceptance criteria specified by the refrigerator manufacturer. It appeared that the food load increases the DFD slightly. The thermal load tends to increase the differences because of the thermal deformation, especially the DFD, of the cabinet and doors.

캐비닛내부응답스펙트럼 산정을 위한 리츠방법의 정식화 및 단순예제를 통한 검증 (Formulation and Verification on Ritz Method for In-Cabinet Response Spectrum)

  • 김기현;홍기증;조성국;박웅기
    • 한국지진공학회논문집
    • /
    • 제23권5호
    • /
    • pp.279-288
    • /
    • 2019
  • Safety-related cabinets and their electrical parts, such as relays and switches in nuclear power plants, should maintain continuous functioning, as well as structural safety according to the nuclear regulatory guidelines. Generally, an electrical part is qualified if its functioning is maintained without abnormality during excitement by motion compatible with the test response spectrum, which is larger than its in-cabinet response spectrum (ICRS). ICRS can be determined by shake-table test or dynamic analysis. Since existing cabinets in use can hardly be stopped and moved, dynamic analysis is preferred over shake-table test in determining ICRS. The simple method, suggested by the Electric Power Research Institute (EPRI) to determine ICRS, yields conservative or non-conservative results from time to time. In order to determine that the ICRS is better than EPRI method in a simple way, Ritz method considering global and local plate behaviors was suggested by Gupta et al. In this paper, the Ritz method is modified in order to consider the rocking and frame behaviors simultaneously, and it is applied to a simple numerical example for verification. ICRS is determined by Ritz method and compared with the results by finite element method (FEM). Based on this numerical example, recommendations for using Ritz method are suggested.

캐비닛 엑스선 검색장비 이미지품질평가 고도화 방안 연구 (Improving Imaging Quality Assessment of Cabinet X-Ray Security Systems)

  • 윤연아;정진형;김용수
    • 품질경영학회지
    • /
    • 제49권1호
    • /
    • pp.47-60
    • /
    • 2021
  • Purpose: This study proposes methods and procedures for evaluating imaging security systems quality of cabinet x-ray screening system to enhance performance certification technology. Also, conducted a comparative analysis of the literature of test-kit for imaging security quality evaluation. Methods: Comparative analysis of the test-kits and related documents for image quality assessment of cabinet x-ray screening equipment. This allows assessment items were selected and the methods for each assessment item were proposed. In addition, the configuration method of the assessment team was established by applying the technology readiness assessment(TRA). Results: Four of the assessment items were selected when estimate image quality by a comparative analysis of literature. For each assessment item, the evaluation method and minimum level of availability were determined. Finally, this paper proposes an imaging quality assessment of cabinet X-ray imaging security systems. Conclusion: Development of imaging security systems evaluation procedures for cabinet X-ray screening systems can be help improve performance certification of aviation security equipment.

캐비닛 구조물의 내부 마찰소음 발생 메커니즘에 관한 실험적 연구 (Investigation of Mechanism of Frictional Impulse Noise in Closed Cabinet)

  • 이동규;박정현;박기홍;하병국;김형식;박상후
    • 대한기계학회논문집A
    • /
    • 제37권2호
    • /
    • pp.249-255
    • /
    • 2013
  • 대형 냉장고의 경우 내부구조가 복잡하고 냉장고 문을 열고 닫을 때 냉장고 내부에 온도편차가 발생하며, 또한 진동에 의한 흔들림이 발생하게 된다. 이러한 다양한 원인에 의하여 간헐적으로 부품간 마찰에 의한 이상소음이 발생하기도 한다. 따라서 본 연구에서는 이러한 이상소음의 원인과 메커니즘을 실험적으로 분석하고 이것을 줄일 수 있는 가능성에 대하여 제안하고자 한다. 이상 소음을 구현하기 위한 실험장치를 구성하고 냉장고 문의 열림과 닫힘에서 발생되는 변형량 분석과 온도 변화에 따른 내부 압력변화를 측정하여 소음발생의 주요원인에 대하여 분석하였다. 또한 설계초기 단계에서 적용이 가능한 소음저감 방법론을 제안하였다.

응급의료센터 자동약품분배 캐비닛시스템 운영으로 인한 야간 약국업무개선 (Improvement of Night Pharmacy Service by Automated Dispensing Cabinet System Implementation in Emergency Medical Center)

  • 김경희;김선아;이정연
    • 한국임상약학회지
    • /
    • 제28권1호
    • /
    • pp.51-56
    • /
    • 2018
  • Objective: An automated process for medication preparation and dispensing is essential to improve the quality of work. To reduce night pharmacy workload, a new automated dispensing cabinet system was implemented in a hospital emergency medical center. The purpose of this study is to verify that implementation of an automated dispensing cabinet system will influence the efficiency of night pharmacy work. Methods: To evaluate the new system implementation, a retrospective study and survey was performed in the Ewha Womans University medical center. We compared the dispensing and near-miss error rates between the automated dispensing cabinet system and a night pharmacy. The degree of satisfaction of night shift workers with the new system was surveyed. Results: This study showed significantly reduced dispensing rates of night medications (56.1% and 37.3%; p < 0.01) and near-miss night medications (0.27% and 0.17%; p<0.01). Thirty-two persons responded to the survey, and the satisfaction score for the new system was 4.0 (${\pm}0.8$). The scores were high in order of efficiency, management, and convenience. Time requirement was also reduced because of the simple step of only reviewing in the pharmacy with the new system. Conclusion: Due to system implementation, workload was reduced and time was saved for not only night shift workers but also patients receiving emergency discharge medicine. It was suggested that this will have a positive effect on pharmacist medical service and patient safety.