• Title/Summary/Keyword: 카메라 렌즈

Search Result 500, Processing Time 0.024 seconds

Acquisition of Subcentimeter GSD Images Using UAV and Analysis of Visual Resolution (UAV를 이용한 Subcentimeter GSD 영상의 취득 및 시각적 해상도 분석)

  • Han, Soohee;Hong, Chang-Ki
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.35 no.6
    • /
    • pp.563-572
    • /
    • 2017
  • The purpose of the study is to investigate the effect of flight height, flight speed, exposure time of camera shutter and autofocusing on the visual resolution of the image in order to obtain ultra-high resolution images with a GSD less than 1cm. It is also aimed to evaluate the ease of recognition of various types of aerial targets. For this purpose, we measured the visual resolution using a 7952*5304 pixel 35mm CMOS sensor and a 55mm prime lens at 20m intervals from 20m to 120m above ground. As a result, with automatic focusing, the visual resolution is measured 1.1~1.6 times as the theoretical GSD, and without automatic focusing, 1.5~3.5 times. Next, the camera was shot at 80m above ground at a constant flight speed of 5m/s, while reducing the exposure time by 1/2 from 1/60sec to 1/2000sec. Assuming that blur is allowed within 1 pixel, the visual resolution is 1.3~1.5 times larger than the theoretical GSD when the exposure time is kept within the longest exposure time, and 1.4~3.0 times larger when it is not kept. If the aerial targets are printed on A4 paper and they are shot within 80m above ground, the encoded targets can be recognized automatically by commercial software, and various types of general targets and coded ones can be manually recognized with ease.

Development of Optical Molecular Imaging System for the Acquisition of Bioluminescence Signals from Small Animals (소동물 발광영상 측정을 위한 광학분자영상기기의 개발)

  • Lee, Byeong-Il;Kim, Hyeon-Sik;Jeong, Hye-Jin;Lee, Hyung-Jae;Moon, Seung-Min;Kwon, Seung-Young;Choi, Eun-Seo;Jeong, Shin-Young;Bom, Hee-Seung;Min, Jung-Joon
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.4
    • /
    • pp.344-351
    • /
    • 2009
  • Purpose: Optical imaging is providing great advance and improvement in genetic and molecular imaging of animals and humans. Optical imaging system consists of optical imaging devices, which carry out major function for monitoring, tracing, and imaging in most of molecular in-vivo researches. In bio-luminescent imaging, small animals containing luciferase gene locally irradiate light, and emitted photons transmitted through skin of the small animals are imaged by using a high sensitive charged coupled device (CCD) camera. In this paper, we introduced optical imaging system for the image acquisition of bio-luminescent signals emitted from small animals. Materials and Methods: In the system, Nikon lens and four LED light sources were mounted at the inside of a dark box. A cooled CCD camera equipped with a control module was used. Results: We tested the performance of the optical imaging system using effendorf tube and light emitting bacteria which injected intravenously into CT26 tumor bearing nude mouse. The performance of implemented optical imaging system for bio-luminescence imaging was demonstrated and the feasibility of the system in small animal imaging application was proved. Conclusion: We anticipate this system could be a useful tool for the molecular imaging of small animals adaptable for various experimental conditions in future.

Fast Light Source Estimation Technique for Effective Synthesis of Mixed Reality Scene (효과적인 혼합현실 장면 생성을 위한 고속의 광원 추정 기법)

  • Shin, Seungmi;Seo, Woong;Ihm, Insung
    • Journal of the Korea Computer Graphics Society
    • /
    • v.22 no.3
    • /
    • pp.89-99
    • /
    • 2016
  • One of the fundamental elements in developing mixed reality applications is to effectively analyze and apply the environmental lighting information to image synthesis. In particular, interactive applications require to process dynamically varying lighting sources in real-time, reflecting them properly in rendering results. Previous related works are not often appropriate for this because they are usually designed to synthesize photorealistic images, generating too many, often exponentially increasing, light sources or having too heavy a computational complexity. In this paper, we present a fast light source estimation technique that aims to search for primary light sources on the fly from a sequence of video images taken by a camera equipped with a fisheye lens. In contrast to previous methods, our technique can adust the number of found light sources approximately to the size that a user specifies. Thus, it can be effectively used in Phong-illumination-model-based direct illumination or soft shadow generation through light sampling over area lights.

Evaluation of Particle Counting by Smartphone-based Fluorescence Smartscope and Particle Positioning in Spinning Helical Channel (스마트폰 기반 형광 smartscope의 입자계수 및 회전하는 나선형 채널의 입자정렬 성능 평가)

  • Park, Eunjung;Kim, Subin;Cho, Myoung-Ock;Kim, Kyunghoon;Shourav, Mohiuddin Khan;Kim, Sunwook;Lee, Jeonghoon;Kim, Jung Kyung
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.20 no.3
    • /
    • pp.19-28
    • /
    • 2015
  • With the aim of developing a smartphone-based point-of-care device that is small, inexpensive, and easy to handle by non-expert, we designed a fluorescence smartscope for counting particles and a DC motor-controlled particle positioning system. Our smartscope can count the number of fluorescent particles and fluorescently-stained white blood cells through a phone camera with an adaptor containing a LED, a ball lens and optical filters and an application running on a smartphone. The motor was controlled wirelessly via Bluetooth with an Android smartphone. We found that axial spinning of a helical microfluidic channel allows arrangement of particles having size similar to the white blood cells. The motor-controlled particle positioning system can minimize time-consuming manual processes and automate sample preparation process and thus, if integrated with the smartscope, it can be used for a point-of-care testing device based on a smartphone.

A Simple Method to Determination the Rotation Angle Between an Image and its Diffraction Pattern with LACBED Patterns (LACBED 패턴으로부터 전자현미경 상에 대한 회절도형의 회전각을 측정하는 간단한 방법)

  • Kim, Hwang-Su;Kim, Jong-Pil
    • Applied Microscopy
    • /
    • v.33 no.3
    • /
    • pp.187-193
    • /
    • 2003
  • When electron microscope images and selected area diffraction patterns of crystalline materials are being compared, it is important to know for the rotation of the diffraction pattern with respect to the image caused by the magnetic lens in the Electron Microscope. A well-known method to determine this rotation is to use a test crystal of $MoO_3$. But this method of determination of the rotation angle contains an uncertainty of $180^{\circ}$. Thus one has to devise another way to eliminate this uncertainty. In this paper we present a new and simple method of determining this rotation without any complexity. The method involves a process of obtaining LACBED patterns of crystalline materials. For the J2010 electron microscope, the rotation is determined to be $180^{\circ}$ and this angle remains unchanged for changing of the magnification and the camera length.

Extraction of Subject Size in Still Image Using Floor Pattern (바닥 패턴을 이용한 단일영상 내의 피사체 크기 추출)

  • Hwang, Min-Gu;Kim, Dong-Min;Har, Dong-Hwan
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.4
    • /
    • pp.11-17
    • /
    • 2011
  • This paper aims to realize the information of a subject existing in a still image with objective values. To attain the goal, this research takes the vanishing point that a 2D still image has as the basis and recomposes the still image into a 3D image using a 3D program. Also, in order to set up the axis of the camera necessary to recompose a 3D image, this paper used the lens angle of view that the image has and floor patterns as well. The 3D image completed in this way can measure the size and distance of all subjects in the floor patterns if the size value of a particular reference subject is known, and through this, it can be possible to acquire basic information of a subject that can be either a criminal or a clue in the images of CCTVs or some criminal scene.

High-Speed Inkjet Monitoring Module for Jetting Failure Inspection (잉크액적 토출불량 검출을 위한 고속 잉크젯 모니터링 모듈)

  • Shin, Dong-Youn
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.10
    • /
    • pp.1521-1527
    • /
    • 2010
  • Since inkjet printing is being employed in production lines of electronics and display industries, the tack time for inspection of jetting failure has become very important because the throughput of the inkjet printing system can be extended to the maximum limit by adopting a shorter jetting inspection time. The most popular method for inspecting jetting failure involves the use of a linear stage, a high magnification lens, and a charge coupled devicecamera. However, this conventional approach requires approximately 60 s to complete the jetting inspection and might not be suitable for a high-speed reciprocating jetting inspection in endurance tests due to the unwanted mechanical vibration. In this study, a novel concept of an inkjet monitoring module is introduced, which has an overall inspection time of 18 s. For the shorter tack time of jetting inspection, the parameters affecting the tack time are discussed in this paper.

Synchrotron Radiation Imaging of Tissues Using Phase Contrast Technique (방사광 위상차 현미경을 이용한 생체조직의 미세구조 영상)

  • Kang, Bo-Sun;Lee, Dong-Yeol;Kim, Ki-Hong
    • Journal of the Korean Society of Radiology
    • /
    • v.2 no.2
    • /
    • pp.23-30
    • /
    • 2008
  • X-ray microscopy with synchrotron radiation(SR) might be a useful tool for novel x-ray imaging in the clinical and laboratory settings. Microscopically, it enables us to observe detailed structure of animal organs samples with a great magnification power and an excellent resolution. The phase contrast mechanisms in image by X-ray are described. The phase-contrast X-ray imaging with SR from in-vivo and in-vitro mouse tail, rat nerve and rat lung were obtained with an 8 KeV monochromatic beam. The visual image was magnified using 10x microscope objective lens and captured using an digital CCD camera. The results showed more structural details and high resolution images with SR imaging system than conventional X-ray radiography system. The SR imaging system may have a potential for imaging in biological researches, material applications and clinical radiography.

  • PDF

Comparative Performance Evaluations of Eye Detection algorithm (눈 검출 알고리즘에 대한 성능 비교 연구)

  • Gwon, Su-Yeong;Cho, Chul-Woo;Lee, Won-Oh;Lee, Hyeon-Chang;Park, Kang-Ryoung;Lee, Hee-Kyung;Cha, Ji-Hun
    • Journal of Korea Multimedia Society
    • /
    • v.15 no.6
    • /
    • pp.722-730
    • /
    • 2012
  • Recently, eye image information has been widely used for iris recognition or gaze detection in biometrics or human computer interaction. According as long distance camera-based system is increasing for user's convenience, the noises such as eyebrow, forehead and skin areas which can degrade the accuracy of eye detection are included in the captured image. And fast processing speed is also required in this system in addition to the high accuracy of eye detection. So, we compared the most widely used algorithms for eye detection such as AdaBoost eye detection algorithm, adaptive template matching+AdaBoost algorithm, CAMShift+AdaBoost algorithm and rapid eye detection method. And these methods were compared with images including light changes, naive eye and the cases wearing contact lens or eyeglasses in terms of accuracy and processing speed.

Analysis of Frequency Response of Piezo Stages and Scanning Path Monitoring/Compensation for Scanning Laser Optical Tweezers (주사 레이저 광집게를 위한 압전 구동기 주파수 특성 분석과 주사 경로 추적 및 보상)

  • Hwang, Sun-Uk;Lee, Song-Woo;Lee, Yong-Gu
    • Korean Journal of Optics and Photonics
    • /
    • v.19 no.2
    • /
    • pp.132-139
    • /
    • 2008
  • In scanning laser optical tweezers, high speed scanning stages are used to manipulate a laser beam spot. Due to the inertia of the stage, the output scanning signal decreases with increased frequency of the input signal. This discrepancy in the signals is difficult to observe since most of the energy from the laser beam is blocked out to avoid CCD damage. In this paper, we propose two methods to alleviate these problems. Firstly, frequency responses of piezo stages are measured to analyze the signal drops and the input signal is compensated accordingly. Secondly, an overlay of the scanning path is drawn on the live monitoring screen to enhance the visibility of the scanning path. The result is a drop-compensated scanning with clear path view.