• 제목/요약/키워드: 침투시설 실험

검색결과 66건 처리시간 0.031초

An Experimental Study on the Application Method of Infiltration Trench (침투트렌치 적용방안에 관한 실험적 연구)

  • Jung, Do-Joon;Ahn, Seung-Sub;Kim, Yun-Tae
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • 제10권6호
    • /
    • pp.147-154
    • /
    • 2010
  • In this study, flood control effects for infiltration trench which is one of runoff reduction facilities were analyzed based on hydraulic experiments. Hydraulic experiments were conducted using 25 cm diameter circular pipe, and water depths for boundary conditions are 5, 10, 15, 20, 25 cm. Infiltration volume, runoff volume, runoff initiation time, final infiltration capacity and final infiltration capacity reached time etc. were measured from infiltration trench hydraulic experiment. We assumed that drainage area of each infiltration trench is $130\;m^2$ ($6.5\;m{\times}20\;m$) and calculated CN with area based on those experimental characteristics. In AMC-I condition, the calculated CN with five water depths is 84 for 2% pipe slope, 83 for 5% pipe slope. In AMC-III condition, the calculated CN is 84 for 2% and 5% pipe slope.

Study on Water Cycle Performance Evaluation Experiment of Permeable Block (투수블럭의 물순환 성능평가 실험에 관한 연구)

  • Jang, Young Su;Park, Jong Bin;Lee, Jae Hyuk;Kim, Jae Moon;Jung, Min Ho;Shin, Hyun Suk
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 한국수자원학회 2020년도 학술발표회
    • /
    • pp.331-331
    • /
    • 2020
  • 급격한 산업화와 도시화로 인한 도시유역의 불투수면의 증가와 이에 따른 배수능력의 저하로 인해 도시 물순환의 왜곡이 발생하였다. 따라서 과거 도시 물관리 기법의 한계가 나타났으며 이를 위해 저영향개발 기법 등과 같은 도시 물관리 기법의 패러다임이 변화하였다. 본 연구에서는 저영향개발 기법에서 도시유역 내 활용이 유용한 침투형 시설 중 투수블럭에 대한 물순환 성능평가를 실외실험을 통해 분석하였다. 성능평가 실험은 부산대학교 양산캠퍼스 한국 GI&LID 센터 내 투수블록 뿐만 아니라 블록 하부 골재층까지 설치가 가능하도록 되어있어 실제 현장과 유사한 환경을 구축이 가능한 2.4×10.9×0.4 (m) 규모의 주차장형 LID 실증시험시설을 활용하였다. 인공강우 분사를 위한 실외 인공강우모사 장치 크기는 2×2(m)으로 본 시험을 위하여 5개의 인공강우모사 장치를 연결하여 활용하였으며, 본 시험장치는 강우를 공급하기 위한 수조와 펌프, 일정한 유량을 유입하기 위한 유량계, 강우를 분사하기 위한 노즐, 인공강우가 실제 강우와 같이 자유낙하 하도록 구현하기 위한 오실레이터 등으로 구성되었다. 시험대상인 틈새투수블록은 석재블록 규격 400×600×100 mm이며 재질은 받침안정층(흙), 투수블록(화강석)으로 구성되어 있다. 실험의 시나리오는 시험체에 강우강도 30mm/hr, 50mm/hr, 100mm/hr에 해당하는 양을 1시간 동안 유입하여 시험 시작 후, 강우지속시간, 표면유출지속시간, 표면유출량을 1분 단위로 측정. 시험체에 유공관이 설치된 경우에는 침투유출지속시간, 침투유출량도 함께 1분 단위로 측정하였으며 각 강우강도별로 측정하고, 1회 측정 후, 각 시험별 시험 대상체의 조건을 같게 하기 위한(하부 지반의 건조) 약 3일 이후(상황에 따라 변동 가능) 시험하였다. 본 실험의 결과, 강우강도가 30 mm/hr와 50 mm/hr인 경우에는 화강석 틈새투수블록포장에서 지표 유출이 발생하지 않았으며, 강우강도 100 mm/hr의 경우 260 L의 지표 유출이 발생하여, 불투수표면 대비 84%의 지표유출 저감률을 보여줌으로서 투수블럭에 물순환 성능에 대한 효과를 분석하였다.

  • PDF

Reduction Rate of the Total Runoff Volume though Installing a Rainfall Storage Tank in the Sub-Surface (지하 빗물저류시설의 설치에 따른 유출 저감 효과 분석)

  • Choi, Gye-Woon;Choi, Jong-Young;Li, Jin-Won
    • Journal of Korea Water Resources Association
    • /
    • 제36권3호
    • /
    • pp.455-464
    • /
    • 2003
  • In this paper, the experiments with installing a rainfall storage tank in the sub-surface were conducted and the reduction rates of the total runoff volume were investigated. The analysis were conducted based upon the variations of the rainfall intensity, surface coverage and surface slope. The reduction rate of the runoff volume was varied from 42.3% to 52.9% with the soil in the bank of the Seung Gi stream. In the experiments, the rainfall intensities were varied from 40mm/hr to 100mm/hr and the results indicate that the direct runoff reduction can be obtained with the installation of the rainfall storage tank in the sub-surface. The variation of the stored volume in the tank is very large in the mild slope but very small in the steep slope with over 3% slope. With this results, the reduction of the direct runoff volume for the longtime flood is expected with the installation of the rainfall storage tank in the region haying the steep slope such as the mountain area.

Hydrological performance analysis of green wall through indoor experiment (실내실험을 통한 벽면녹화에 따른 물순환 효과 분석)

  • Ji Hyun Moon;Jae Rock Park;Soon Chul Kwon;Jae Moon Kim
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 한국수자원학회 2023년도 학술발표회
    • /
    • pp.302-302
    • /
    • 2023
  • 최근 도시의 왜곡된 물순환 문제를 해결하기 위해서 저영향개발(Low Impact Development, LID) 기법을 적극적으로 도입하고 있다. 저영향개발은 자연의 침투, 증발산, 여과 등의 자연기작을 모방하여 강우유출수를 침투 및 저류시키는 기법으로 물순환 체계를 회복시킬 수 있다. 저영향개발 기법의 하나인 벽면녹화는 건축물이나 기반 시설물의 벽면과 같은 인공지반에 기반을 조성하고 식물을 식재하는 시설로 짧은 시간에 녹지 면적을 만들 수 있다. 또한, 건축물로 인해 생겨난 수직적인 면을 녹지로 활용할 수 있어 도시에 매우 특화된 시설이다. 본 연구는 벽면녹화의 저영향개발 시설로서의 성능을 확인하기 위해 실내 실험을 진행하여 강우유출수 저감효과 및 지체시간 지연효과를 확인하였다. 강우유출수 저감효과는 유입량 대비 저류량을 기준으로 유출저감률을 산정하여 분석하였으며, 총 유출시간을 측정하여 지연효과를 판단하였다. 벽면녹화 현장실험 대상지는 경상남도 양산시 물금읍 부산대학교 양산캠퍼스에 위치한 한국 녹색인프라저영향개발센터이며, 실내에 플랜터형 벽면녹화 시스템을 적용하였다. 부산시 금정구 2012년~2021년의 강수량을 사용해 백분위수 강우사상을 기준으로 30, 50, 70mm/hr의 강우 시나리오를 선정하였다. 물순환 효과를 판단하기 위해 불투수면을 대조군으로 설정하여 불투수면의 유출이 종료되는 시점까지 지표면 유출을 모니터링 하였다. 그 결과, 30, 50, 70mm/hr 시나리오별 유출률은 91.76%, 92.18%, 94.54%로 불투수면과 대비하여 유출이 적게 발생하였으며 총 유출시간은 불투수면대비 47분, 88분, 58분 증가하여 지연효과가 있음을 확인하였다. 본 연구는 실험을 통해 벽면녹화의 수문학적 성능을 분석하고자 유출량 저감효과와 지연효과를 확인하였다. 추후 다양한 강우 시나리오와 제원에 따라 실험이 수행된다면 더 정확히 벽면녹화의 물순환 효과를 확인할 수 있을 것이다.

  • PDF

Development Hybrid Filter System for Applicable on Various Rainfall (다양한 강우사상에 대응 가능한 침투여과형 기술개발)

  • Choi, Jiyeon;Kim, Soonseok;Lee, Soyoung;Nam, Guisook;Cho, Hyejin;Kim, Lee-Hyung
    • Journal of Wetlands Research
    • /
    • 제15권4호
    • /
    • pp.535-541
    • /
    • 2013
  • The urbanization affects significantly on a natural water circulation system by increasing the imperviousness rate. It is also negatively affecting on urban temperature, environmental pollution, water quality, and aqua-ecosystems. The Korea MOE (Ministry of Environment) adapted a new environmental policy in order to reduce the impact of urbanization, which is the Green Stormwater Infrastructure (GSI) program. The GSI can be achieved by protecting conservable green spaces, enlarging more green spaces, and constructing more permeable pavements. The GSI is including many different techniques such as bioretention, rain garden, infiltration trench and so on. Also It is the infrastructures using natural mechanisms of soils, microorganisms, plants and animals on a water circulation system and pollutant reduction. In this research, a multi functional GSI technology with infiltration-filtration mechanisms has been developed and performed lab-scale tests to evaluate the performances about infiltration rate restoration and pollutant reduction. The most of pollutants including metals, organics and particulates were reduced about 50~90% due to water infiltration and storage functions. The clogging was found when the TSS loading rate was reached on $8.3{\sim}9.0kg/m^2$, which value is higher than the values in literatures. It means the new technology can show high performances with low maintenances.

Analysis of Infiltration Trench Facility for Runoff Reduction Effect (침투트렌치 시설의 유출저감 효과 분석)

  • Yeon, Jong Sang;Jang, Young Su;Shin, Hyun Suk;Kim, Eung Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • 제15권9호
    • /
    • pp.5813-5819
    • /
    • 2014
  • LID planning and application has been actively developed to reduce the runoff volume at increased impervious areas due to rapid urbanization. In this study, a performance and applicability evaluation was performed in an infiltration trench using the SWMM model, based on the experimental conditions for infiltration trenches. The infiltration trench application area was applied to 5~15% of the drainage area. The SWMM results of discharge and the BOD reduction efficiency were analyzed at a peak discharge of 45.7~61.9%, total discharge of 47.2~62.3%, and BOD load of 52.3~55.3. The discharge and BOD was estimated to be 12~24% higher and 37~38% smaller than the experimental results. This study can help in the application and performance evaluation of infiltration trenches.

An Experimental Study on Consolidation Effect of Dredged and Reclaimed Ground with PBD using Seepage Pressure (침투압을 이용한 PBD 타입 준설매립 지반의 압밀 효과에 관한 실험적 연구)

  • Lee, Moo-Chul;Park, Min-Chul;Kim, Ju-Hyun;Lee, Song
    • Journal of the Korean GEO-environmental Society
    • /
    • 제13권5호
    • /
    • pp.13-24
    • /
    • 2012
  • In this study, the in-situ model test has been conducted and used to estimate and analyze consolidation behavior of the ground by using the miniature test that reconstructs economically geotechnical behavior of in-situ full scale structure. To analogize the relation among effective stress, void ratio and coefficient of permeability at the self-weight consolidation stage, the low stress seepage consolidation test has been conducted and the involution function of constitutive equation had been obtained from the result of the curve fitted seepage consolidation test result. As a result of the numerical analysis that had been conducted on the representative section using a constitute equation, final settlement was similar with those of self-weight consolidation of the centrifugal model test. But, it was more or less smaller. It seems that these trends are caused by the difference between estimated values.

An Experimental Study on Evaluation of Bond Strength of Arc Thermal Metal Spaying According to Treatment Method of Water Facilities Concrete Surface (수처리 시설물 콘크리트 표면처리 방법에 따른 금속용사 피막의 부착성능 평가에 관한 실험적 연구)

  • Park, Jin-Ho;Lee, Han-Seung;Shin, Jun-Ho
    • Journal of the Korea Institute of Building Construction
    • /
    • 제16권2호
    • /
    • pp.107-115
    • /
    • 2016
  • In this study, the bond strength of metal spraying system by surface treatment of concrete (waterproof/corrosion method) in water treatment facilities was evaluated. The results showed that the system with Sa-P-R-(S) (sanding-perviousness surface hardener-surface roughness agent-metal spraying-sealing) led to the desirable performance. The bond strength, the coefficient of water permeability and air permeability were 3.7MPa, $0.68{\ast}10^{-8}cm/sec$, and $0.45{\ast}10^{-16}m^2$, respectively. In scanning electron microscope analysis, the microstructure of specimen coated with perviousness surface hardener was much denser than that without it. Therefore, the specimen coated with sanding-perviousness surface hardener-surface roughness agent-metal spraying-sealing had the best bond performance and was the most suitable system to concrete surface in water treatment facilities.

원자력시설의 제염해체 공정중 분진처리 성능평가

  • 이기원;최병선;이후근;오원진;이병직;박현수
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 한국원자력학회 1997년도 춘계학술발표회논문집(2)
    • /
    • pp.307-312
    • /
    • 1997
  • 원자력시설의 콘크리트 표면제염 및 절단을 효과적으로 수행하기 위해서는 먼저 방사성물질이 제염구역의 외부로 누출되지 않도록 작업구역을 비방사성 구역과 분리하고, 국부적으로 오염된 콘크리트 표면을 제염하는 기술, 해체 절단하는 기술 및 경제적인 방법으로 방사성물질의 확산을 최소화하는 분진제거 기술 등이 개발되어야 한다. 따라서 본 논문에서는 원자력시설의 콘크리트 표면제염 및 절단시 발생되는 콘크리트 분진처리 필터시스템을 개발하기 위하여, 중량 및 고밀도 콘크리트 내부로의 세슘 및 스트론튬 핵종의 침투깊이 실험을 수행하였으며, 다중 사이클론을 이용하여 DOP 에어로졸 및 콘크리트 표면절단 장비인 scabbier에 의해 발생한 중량 및 고밀도 콘크리트 분진의 특성을 분석하고 포집효율 성능시험을 수행하였다. 또한 사이클론 성능평가 프로그램을 작성하여 사이클론의 포집효율을 예상하였으며 이를 실험값과 비교하였다.

  • PDF

Runoff Reduction Effect Analysis of Porous Asphalt Using Rainfall Simulator of Movable-Assemble Type (이동형 강우모의장치를 이용한 투수성 아스팔트 유출저감 효과 분석)

  • Jang, Youngsu;Park, Jaerock;Chun, Jonghyun;Park, Jaehyun;Shin, Hyunsuk
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 한국수자원학회 2018년도 학술발표회
    • /
    • pp.382-382
    • /
    • 2018
  • 최근 기후변화 및 도시화로 인해 집중호우와 도시 내의 불투수층이 증가하고 있으며, 현재 도심의 강우관리시스템이 한계에 달하여 수재해 피해가 급증하고 있다. 이와 같은 문제를 해결하기 위한 방안으로 저영향개발 기법이 대두되고 있으며, 본 기법은 해당 지역의 강우를 분산식 빗물처리 하여 도시 내의 수문학적 특성을 개발이전 상태로 회복 및 유지하는 기술이다. 저영향개발 기법의 종류는 투수성 포장, 옥상녹화, 빗물정원, 식생저류지, 식생화분 등이 있다. 본 연구에서는 저영향개발 기법 중 하나인 투수성 아스팔트에 대한 우수저감 효과를 분석하기 위해 경상남도 양산시 부산대학교 양산캠퍼스 그린인프라 저영향개발 센터에서 주차장형 LID 시설의 투수성 아스팔트 포장과 대조군인 불투수 콘크리트 포장을 실험대상으로 선정하였다. 포장체는 $10.85m(L){\times}2.3m(B){\times}0.9 m(H)$의 크기로 원지반 침투가 없는 박스형 실험시설로써 이동형 강우모의장치를 이용하여 인공강우실험을 실시하였다. 강우모의 시에 발생하는 지표유출 및 침투유출은 각 유공관을 통해 모니터링 박스에 차집되어 실시간으로 웹사이트 상에 저장된다. 저장된 자료를 이용하여 투수성아스팔트의 첨두유출량 저감, 지체시간지연효과를 분석하였다. 분석된 결과를 통해 첨두유출량은 11%저감되었고 투수성 아스팔트와 불투수 콘크리트는 각각 3시간, 1시간 동안 유출되어 2시간의 차이를 보여준다.

  • PDF