• Title/Summary/Keyword: 침출수 확산

Search Result 36, Processing Time 0.021 seconds

Groundwater Contamination at the Seokdae Waste Landfill Area of Pusan City (부산 석대 폐기물 매립장 일대의 지하수 오염)

  • 정상용
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.2 no.1
    • /
    • pp.1-8
    • /
    • 1995
  • Wastes produce groundwater contamination, offensive odor, and hazardous gases. This study investigates the contamination of groundwater at the Seokdae waste landfill area and seeks the desirable ways to minimize the groundwater contamination. Groundwater levels, water chemistry and aquifer characteristics of wells were examined around the Seokdae waste landfill. The water chemistry of the Dong stream, the groundwater distribution and flow were also studied. The results of this research show that the estimated quantity of the percolation from the landfill base to the ground is 520 ㎥/day and the extent of groundwater contamination is about 1-1.5 km from the center of the waste landfill. The groundwater contains heavy metals and other toxic elements. The conservation and management of the groundwater of the waste landfill need several monitoring wells to check the quantity and quality of groundwater, pumping wells to extract the contaminated groundwater, and slurry walls to protect the movement of contaminated groundwater.

  • PDF

Characterization of Water Quality and the Aerobic Bacterial Population in Leachate Derived from Animal Carcass Disposal (가축 매몰지 침출수에 대한 수질 특성 및 호기성 미생물 분포에 관한 연구)

  • Choi, Nag-Choul;Choi, Eun-Ju;Kim, Bong-Ju;Park, Jeong-Ann;Kim, Song-Bae;Park, Cheon-Young
    • The Journal of Engineering Geology
    • /
    • v.23 no.1
    • /
    • pp.37-46
    • /
    • 2013
  • Leakage of leachate from animal carcass disposal is a significant issue because disease can easily spread to humans and other livestock. In this study, we analyzed the physicochemical properties of leachate and tested for the presence of aerobic bacteria in leachate using molecular biology methods, for 16 animal carcass disposals in the first stage (after burial for 5 months). Leachate physicochemical analysis revealed higher total coliforms, TOC, $NH^{4+}$, and $NO^{3-}$ concentrations compared with previously published data. In most leachate samples, the concentrations of $NH^{4+}$ and $NO^{3-}$ exceeded the Korean guideline values for drinking water. In 16S rRNA sequence analysis of the distribution of leachate under aerobic conditions, Bacillus pumilus, Lysinibacillus sphaericus, and B. sphaericus were observed with high frequency, whereas no food-poisoning-related bacteria such as B. cereus or Salmonella were detected. The present findings improve our knowledge of the transport of leachate from animal carcass disposal sites through geologic media, and are useful in risk analysis and for subsequent studies.

The Analytical Radioactive Waste Repository Source Term REPS Model (방사성폐기물 처분장 선원항 REPS 모델)

  • Kim, Chang-Lak;Cho, Chan-Hee;Park, Kwang-Sub;Kim, Jinwung
    • Nuclear Engineering and Technology
    • /
    • v.22 no.4
    • /
    • pp.315-325
    • /
    • 1990
  • The analytical repository source term (REPS) computer code is developed for the safety assessment of radioactive waste geologic repository. For reliable prediction of the leach rates for various radionuclides, degradation of concrete structures, corrosion rate of waste container, degree of corrosion on the container surface, and the characteristics of radionuclides are considered in this REPS code. For the validation of the radionuclide leach rates predicted by the REPS model, the calculated leach rates of Cs-137, Sr-85, and Co-60 are compared with two reported leaching test results. Cesium and strontium leach congruently, and the leaching test results of these species can be reproduced by the congruent leaching model included in the REPS model. In case of cobalt, the solid diffusion model is in good agreement with the leaching test results.

  • PDF

A Study on the Separation of Membrane and Leaching of Platinum and Ruthenium by Hydrochloric Acid from MEA of Fuel Cell (연료전지용(燃料電池用) 막전극접합체(膜電極接合體)의 막분리(膜分離) 및 염산(鹽酸)에 의한 백금(白金)과 루테늄의 침출(浸出)에 관(關)한 연구(硏究))

  • Lee, Jin-A;Kang, Hong-Yoon;Ryu, Ho-Jin
    • Resources Recycling
    • /
    • v.21 no.3
    • /
    • pp.15-20
    • /
    • 2012
  • In this paper, we carried out separation of membrane and leaching of Pt and Ru using hydrochloric acid from MEA(membrane-electrode assembly) of fuel cell. In this method, these were separated from MEA of fuel cell using the distilled water, 10 vol.% butanol solution and 15 vol.% cationic surfactant(Koremul-LN-7) by dipping method without the dispersion of catalyst particles. And the leaching of Pt and Ru containing in the separated carbon paper catalysts has been studied by hydrochloric acid using $HNO_3$ or $H_2O_2$ as a oxidant. The leaching ratio of Pt and Ru were higher when $H_2O_2$ was used as a oxidant and the optimum conditions were obtained in 8M HCl, the amount of $H_2O_2$ 5M and 6 hours of leaching time at $90^{\circ}C$. In this condition, extraction of Pt and Ru were 98% and 71.5%, respectively.

The Change in Geotechnical Properties of Clay Liner and the Contamination Behavior of Groundwater Due to Contaminant (오염물질에 의한 점토 차수재의 역학적 특성변화 및 지하수 오염거동)

  • Ha, Kwang-Hyun;Lee, Sang-Eun;Chung, Sung-Rae;Chun, Byung-Sik
    • Journal of Soil and Groundwater Environment
    • /
    • v.13 no.1
    • /
    • pp.13-23
    • /
    • 2008
  • The triaxial compression tests and consolidation tests using NaCl solution and leachates as substitute pore (or saturated) water in samples were carried out to find out the behavior characteristics of strength, deformation and permeability coefficient of contaminated clay. Also, the chemical property analysis on the clay samples using scanning electron microscope and energy dispersive x-ray spectrometer were involved. The magnitudes of composition ratio were shown in the order of O, C, Si, Al, and Fe as a result of chemical composition analysis for clay samples. Besides, as the results of triaxial compression tests and consolidation tests, the shear strength, compression and permeability properties were increased with increasing in the concentration of contaminant (NaCl). It may be considered that these circumstances be caused by the changes of soil structure to flocculent structure due to the decrease in the thickness of diffuse double layer with increasing in the concentration of electrolyte. MT3D model was also using to grasp the procedures that the groundwater may be contaminated by the leachates permeated through the clay liner. The results of contaminant transport analysis showed a tendency that the predicted concentration of groundwater was higher with increasing in the initial concentration of $Cl^-$ ion and increased as a nonlinear curves with time. The transportation distance calculated by the use of regression equation between the distance from contaminant source and the concentration of $Cl^-$ ion was increased with increasing the initial concentration.

The Change in Geotechnical Properties of the Deposited Clay Contaminated by Leachate from Waste Disposals (침출수로 오염된 퇴적점토의 역학적 특성변화)

  • Ha, Kwang-Hyun;Lee, Sang-Eun
    • Journal of the Korean GEO-environmental Society
    • /
    • v.7 no.3
    • /
    • pp.43-54
    • /
    • 2006
  • In this paper, the uniaxial, triaxial compression tests and consolidation tests on the clay sample substituted initial pore water for pollutant were performed to evaluate the change in geotechnical properties of the contaminated clay. The contaminant transport analysis on embankment type landfill using the MT3D model was also performed to evaluate the extent of transport and diffusion. There was tendency that strength, compressibility and permeability has increased with the increase in the concentration of NaCl solution. The increase in the strength and compressibility of sample saturated with leachate was higher than samples saturated with NaCl solution, but in the permeability coefficient was lower. As the result of contaminant transport analysis, the predicted concentration was in high with the increase in the initial concentration of $Cl^-$ ion and increased in a non-linear form. The transportation distance calculated with use of regression equation between the distance from contaminant source and the concentration of $Cl^-$ ion was increased with the increase in the initial concentration.

  • PDF

Estimation of Groundwater Contamination and Pumping Capacity for Purification in Animal Carcass Deposal Site (가축매몰지 오염지하수 정화를 위한 오염범위 및 양수량 평가)

  • Nam, Koung-Hoon;Lee, Hak-Yun;Kim, Geonha;Jeong, Gyo-Cheol
    • The Journal of Engineering Geology
    • /
    • v.25 no.1
    • /
    • pp.45-55
    • /
    • 2015
  • Purifying leachate discharged from animal carcass disposal sites requires decisions regarding the locations and numbers of boreholes. An electrical resistivity survey, known to be effective for investigating leachate distribution, was performed to evaluate the range extent of contamination due to local hydrological properties, such as groundwater flow direction, and geological structure. Results of the survey at four sites at a landfill near Icheon and Anseong, Gyeonggi Province, showed low-resistivity zones (20-200 ohm-m) at a depth of 8 m from the surface. Sites 1-4, which contain 5, 2, 4, and 2 boreholes, respectively, were estimated to have a contaminated groundwater acquisition capability of 12.9 m, 13.7 m, 10.1 m, and 18.0 m, and measured pumping capacity of 2,040 m3, 479.8 m3, 1,492.3 m3, and 691.9 m3, respectively.

Characteristics of Stream and Soil Contamination from the Tailing Disposal and Waste Rocks at the Abandoned Uljin Mine (울진 폐광산의 매립광미와 폐광석에 의한 주변 토양 및 수계의 오염특성)

  • Lee, In-Gyeong;Choi, Sang-Hoon
    • Economic and Environmental Geology
    • /
    • v.41 no.1
    • /
    • pp.63-79
    • /
    • 2008
  • Physicochemical characteristics of stream water, leachate, mine water and groundwater were investigated to estimate the influences of the tailing and waste rock from the abandoned Uljin mine area. Total extraction analysis and mineralogical studies were carried out to understand sulfide weathering and to determine the distributions of trace elements in the soil affected by mine waste (tailing, waste rock and leachate). The pH and EC value of the leachate from the tailing disposal ranged 2.9-6.0, $99{\sim}3,990{\mu}S/cm$, respectively, and the concentrations of dissolved major (up to 492 mg/l Ca; 83.8 mg/l Mg; 45.2 mg/l Na; 44.7 mg/l K, 50.8 mg/l Si) and trace elements (up to $826,060{\mu}g/l$ Fe; $131,230{\mu}g/l$ Mn; $333,600{\mu}g/l$ Al; $61,340{\mu}g/l$ Zn; $2,530{\mu}g/l$ Cu; $573{\mu}g/l$ Cd; $476{\mu}g/l$ Pb) were relatively high. The stream water showed the variation of dissolved metal concentrations in seasonally and spatially. The dissolved metal contents of the stream water increased by influx the leachate from the tailing disposal, but these of the down stream have been considerably decreased by mixing of dilute tributaries. The dissolved metal concentrations of the stream water at dry season (as February) were lower than these at rainy season (as May and July). These represent that the amounts of the leachate varied with season. However, stream water could not be effectively diluted by confluence with uncontaminated tributaries, because the flux of tributaries and streams reduced at dry season. Thus attenuations by dilution had been dominantly happened in rainy seasons. The order of accumulations of trace element in soils compared with background values revealed Mn>Fe>Pb>Cu>Zn. Sulfide minerals were mainly pyrrhotite, sphalerite and galena and chalcopyrite. Pyrrhotite was rapidly weathered along the edge and fractures, and results in the formation of Fe-(oxy)hydroxides, which absorbed a little amount of Zn.

PE 첨가에 의한 방사성폐수지 아스팔트고화체의 특성연구

  • 김태국;손종식;김길정;안섬진;정인하
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05b
    • /
    • pp.385-390
    • /
    • 1998
  • 방사성 페이온교환수지 아스팔트고화체를 처분장 등지에서 장기간 저장시 안전성 확보를 위하여 물리적 강도가 높고 고화체내에서 방사성핵종의 침출저항성 및 처리시 감용의 효과가 우수한 고화체 연구가 필요하게 되었다. 실험에 사용된 이온교환수지는 입상형 양이온 교환수지를 대상으로 하였으며 고화매질로서는 도로포장용으로 생산되는 직류아스팔트 60/70을 사용하였다. 고화보조제는 방사성 고체패기물 포장시 사용되어 폐기물로 발생되는 페폴리에틸렌(폐PE) 필름을 사용하였다. 실험결과 고화체의 형태안정성은 PE 함유량이 10 wt% 이상일 때 고화체 형태를 그대로 유지할 수 있으며 압축강도는 414 kPa(60 psi) 이상을 나타내었다. 최적의 운전조건은 이온교환수지, PE 함유량이 건조기준으로 각각 30~50 wt%, 10~25 wt% 이며, 고화온도는 170~20$0^{\circ}C$이다. 고화체의 침출특성은 확산 (diffusion) 으로 해석이 가능하며, 유효확산계수(De)는 Cs, Co의 경우 각각 1.621$\times$$10^{-7}$, 1.186$\times$$10^{-9}$ $\textrm{cm}^2$/day로 나타나고, Leachablity index는 각각 11.7, 13.8로 미국 원자력위원회 (NRC)가 요구하는 기준값 6보다 훨씬 높게 나타났다.

  • PDF

Distiribution of Metals and Cyanide in Soils and Acid leachate Occurrence around the Daduck mine (다덕광산 주변 토양에서의 금속 및 시안의 분포와 산성침출수 생성)

  • 정영욱;민정식;김인기;김옥환;이승길;우종한;최광호
    • Journal of Korea Soil Environment Society
    • /
    • v.2 no.3
    • /
    • pp.39-47
    • /
    • 1997
  • Geochemical study was carried out to find out the distribution of metals and cyanide in soil in the vicinity of the abandoned Daduck mine and the reason for acid mine drainage occurrence in the tailings impoundment. Chemical analysis showed that content of As in soil around tailings exceeded 15mg/kg, Korean standard of soil contamination in the farm land. That means the contamination of soil by As is due to input of tailings. According to total decomposition of tailings, As, Cd, Cu, Pb, Zn and S were highly concentrated in tailings. However the water in tailings impoundment was changed to acidic and contaminated by metals and sulfate because the tailings in the top of the tailings impoundment had been oxidized. Acid mine drainage contaminated the water course in the vicinity of the paddy soils. The proper measures are required to prevent contamination of the soil and water in the vicinity of the Daduck mine.

  • PDF