• Title/Summary/Keyword: 침전조

Search Result 218, Processing Time 0.029 seconds

Development and Lab-scale Plant Study of Coagulation Sedimentation Module using Cyclone (선회류를 이용한 응집침전모듈의 개발 및 실증 연구)

  • Moon, Jinyoung;Cho, Young-Gun;Song, Seung-Jun;Kim, Jin-Han
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.5
    • /
    • pp.3336-3344
    • /
    • 2014
  • The purpose of this study is small scale coagulation module is developed and demonstrated through a lab-scale test. Recent as a sewage treatment rate increases, have heightened the interest in the necessity on the nonpoint source and developing a small processing unit has been increased. Coagulation sedimentation module in this study is additional growth of floc through swirling in the outside zone, reduction of microstructure floc number and the internal settling zone through vertical/level flow complex sedimentation method after the coagulation process precipitation method as an effective high separation efficiency can be divided was also assessed. Coagulation sedimentation module can increase the load factor was 4.4 times compared to conventional clarifier base on the same volume and surface area through vertical/level flow. In this study, this process was selected formation and maintenance of swirling and uniform flow distribution in the internal settling zone as an important design factor, to derive its FLUENT was used to characteristics of the flow model. Through the simulation of swirling, influent velocity, dimensions of external basin, hopper depth of bottom cone was determined and through analysis of velocity distribution, flow distribution detailed specifications are derived like as diameter and number of effluent hole. Lab-scale($120{\ell}/hr$) test results, influent of 300~800 NTU to less than 10 NTU without polymer feeding was able to operate in the 20minutes retention time(surface loading rate $37.3m^3/m^2$-day), and through analysis FLUENT the possibility of using design parameters were derived.

한외여과(UF)막을 이용한 상수처리 공정의 확립 및 최적화

  • 정두식;오중교;이태진;이용택
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1995.10a
    • /
    • pp.41-42
    • /
    • 1995
  • 기존의 정수처리 공정은 응집-침전-급속여과처리를 주로 사용하면서 생물 활성탄처리-오존처리 등을 거치는 공정으로 이루어져 왔다. 그러나 응집제의 투여시 최적 응집제량, 최적 응집제 투여위치, 교반시간, pH 조절 등 번거러운 test가 선행 되어야 하며 처리수에 남아있는 응집제에 의해 2차 오염을 일으켜 침전조의 부지 면적에 따른 대형화등을 초래할 단점이 있다. 따라서 최근에는 이러한 단점을 보완하고 장치의 간소함, 높은 효율의 유지에 따른 후처리 공정의 부하감소 및 운전 조건 인자등의 감소라는 경제적 효과를 기대할 수 있는 막분리공정이 도입되었다. 그러나 분리막 처리공정의 경우 원수에 다량 포함되어 있는 콜로이드 입자들에 의한 flux의 감소 및 fouling 현상으로 인한 막의 수명감소, 처리수량의 감소 및 최적 설계 및 운전 방법등의 새로운 공정에 대한 많은 자료의 확보가 필요하다. 따라서 본 연구는 기존의 정수처리 공정에 있어서 전처리 부분에 해당하는 응집-침전-급속여과처리 공정을 분리막 공정으로 대체 하였을 때 분리막의 재질 및 module의 차이에 따른 처리 능력을 비교하고 각 단위 공정들에 의한 flux 변화, 각 공정별 수질분석, 회복율, 회수율 등을 검토하여 최적 조건의 공정을 확립하여 후처리 공정의 효율을 극대화 하는데 있다.

  • PDF

Characteristics of Crude Protein-bound Polysaccharide from Agaricus blasei Murill by Extraction and Precipitation Conditions and Its Antitumor Effect (추출 및 침전조건에 따른 아가리쿠스버섯에서 분리한 조단백다당류의 특성 및 암세포 증식억제 효과)

  • Hong, Joo-Heon;Youn, Kwang-Sup;Choi, Yong-Hee
    • Korean Journal of Food Science and Technology
    • /
    • v.36 no.4
    • /
    • pp.586-593
    • /
    • 2004
  • Efficient extraction method of crude protein-bound polysaccharide (CPBP) from Agaricus blasei Murill was established. CPBP yields by ultrasonic and hot water extractions were 13.0 and 7.8%, respectively. Pressure extraction for 3 hr gave the highest ${\beta}-glucan$ content; no significant difference was observed between 2 and 3 hr extraction. Four volumes added ethanol gave the highest yields of CPBP and ${\beta}-glucan$ contents at 10.89 and 35.97%, respectively. Decomposition temperature of CPBP was $240-365^{\circ}C$, showing relatively good thermal stability. In SRB (sulforhodamine B) assay, CPBP treatment at $1,000\;{\mu}g/mL$ for 72 hr inhibited proliferations to A549, MCF-7, and AGS cancer cells by 43.9, 21.4, and 32.5%, respectively.

Effects of Hydraulic Rentention Time on Anaerobic Digestion of the Mixture of Nightsoil and Septic Tank Sludge (소화조(消化槽)의 수리학적(水理學的) 체류시간(滯留時間)이 분뇨(糞尿)와 정화조(淨化槽)슬러지 혼합물(混合物)의 혐기성소화(嫌氣性消化)에 미치는 영향(影響))

  • Lee, Kwang Ho;Yang, Sang Hyun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.3 no.3
    • /
    • pp.117-127
    • /
    • 1983
  • An experimental research was performed employing the two stage anaerobic digestion of the mixture of the nightsoil and septic tank sludge to determine the effects of various hydraulic retention time of the digestion on chemical characteristics and treatment effeciency, thus determining the proper retention time. Results of the research are as follows, 1. Volatile-acid decreased as HRT increased. 2. Alklinity and ammonia-N tended to increase as HRT increased as did pH values, however, were observed to be constant at higher HRT values than 15 days. 3. The removal efficiencies of TBOD, TCOD and VS increased as HRT increased. 4. The removal efficiency of volatile solid decreased as VS loading increased. 5. It was observed that the rates of gas production were: 0.33 with HRT of 5 days, 0.58 with HRT of 15 days and $0.57m^3/kg$ VS fed/day with HRT of 25 days respectively. It is believed that the highest rate of gas production was at HRT of 15 days. 6. The sludge settling experiment showed that the minimum settling time required to ensure the desired underflow concentraton was estimated to be 8.6 days.

  • PDF

Development of SV30 Detection Algorithm and Turbidity Assumption Model using Image Analysis Method (이미지 분석기법을 이용한 SV30 자동감지방법 및 탁도 추정 모델 개발)

  • Choi, Soo-Jung;Kim, Ye-Jin;Yoom, Hoon-Sik;Cha, Jae-Hwan;Choi, Jae-Hoon;Kim, Chang-Won
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.2
    • /
    • pp.168-174
    • /
    • 2008
  • Diagnosis on setteability based on human operator's experimental knowledge, which could be established by long term operation, is a limit factor to construction of automation control system in wastewater treatment plant. On-line SVI(Sludge Volume Index) analyzer was developed which can measure SV30 automatically by image capture and image analysis method. In this paper, information got by settling process was studied using On-line SVI analyzer for better operation & management of WWTPs. First, SV30 detection algorithm was developed using image capture and image analysis for settling test and it showed that automatic detection is feasible even if deflocculation and bulking was occurred. Second, turbidity assessment model was developed using image analysis.

Design and Development of Integrated Recirculating Aquaculture System (순환 여과식 양식 시스템의 설계 및 개발)

  • SUH Kuen-Hack;KIM Byong-Jin;JEON Im Gi
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.34 no.1
    • /
    • pp.70-76
    • /
    • 2001
  • An integrated recirculating aquaculture system suitable to our country's situation was designes and developed, The integrated recirculating aquaculture system consisting of a double drain type rearing tank of the $2.5 m^3$, a sedimentation tank for removal of settleable solids, a floating bead filter for the removal of suspended solids, a foam separator for removal of fine particles and a rotating biological contactor for the nitrification was designed and manufactured. The integrated recirculating aquaculture system was stocked with nile tilapia (Oreochromis niloticus) at $2\%$ rearing density for 2 weeks. Feed coefficient was 1.4 and average daily growth rate was $0.64\%$ in the system for 2 weeks.

  • PDF

The effect of zeolite addition on floc in activated sludge process (제올라이트 주입이 활성슬러지 플럭에 미치는 영향)

  • Lee, Hyung Sool;Park, se Jin;Yoon, Tae Il
    • Clean Technology
    • /
    • v.7 no.1
    • /
    • pp.35-42
    • /
    • 2001
  • This study was performed to evaluate the effect of zeolite addition on biofloc in aictvated sludge process. Two units were compared each other, in which one was operated as control unit (CU) and the other was managed by adding zeolite into aeration basin to sustain 4,000 mg/l (ZU). It was observed that flocs of both units were enduringly increased in medium size by extending SRT (Solid Retention Time), although their effect size of ZU was smaller than theirs of CU. Zeolite application excessively improved sludge settling property and ZU presented sludge settling velocity of 3.4 to 11 m/h regardless of SRT variation. The sludge volume index (SVI) was in the range of 50 and 108 ml/g. Conversely, the sludge settling velocity of CU seriously depended on SRT increase, and sludge sedimentation was not achieved at a 40 days of SRT due to Sphaerotilus appeared predominantly in reactor.

  • PDF

Evaluation in Activity of Pt-Na/$CeO_2$ Catalysts for One-Step Water Gas Shift Reaction via Controlling the Amount of Na Addition (WGS 반응용 Pt-Na/$CeO_2$촉매의 Na 담지량에 따른 성능 평가)

  • Eum, Ic-Hwan;Kim, Ki-Sun;Jeong, Dae-Woon;Lee, Sung-Hun;Koo, Kee Young;Yoon, Wang Lai;Roh, Hyun-Seog
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.230.1-230.1
    • /
    • 2010
  • 조촉매(Promotor)인 Na은 수성가스전이(Water Gas Shift, WGS) 반응 시 생성된 포름산염의 C-H결합을 쉽게 분해하는 역할을 한다. 본 연구에서는 $Pt/CeO_2$ 촉매의 성능 향상을 위해 Na의 담지량을 변화시켜 촉매적 활성을 비교하여 보았다. 제조된 담체는 침전법(Precipitation)을 사용하여 제조하였으며 $500^{\circ}C$에서 6시간 소성하였다. Pt 담지량은 1wt%로 고정하였고 Na 담지량은 1 wt%~5 wt%로 변화를 주어 동시(공)-함침법(Co-incipient wetness method)으로 담지 시켰다. 반응 실험은 공간속도(Gas Hourly Space Velocity, GHSV) $45,385h^{-1}$에서 수행하였다. WGS 반응 결과 3 wt%의 Na이 담지된 $Pt/CeO_2$ 촉매의 경우를 제외하고 나머지 Na이 담지된 촉매들은 비교적 높은 CO의 전환율을 나타내었다. 특히 2 wt%의 Na이 담지된 $Pt/CeO_2$ 촉매는 가장 높은 CO의 전환율을 나타내었다. 따라서 Na 담지량의 변화가 포름산염의 C-H결합 분해에 영향을 미친다는 것을 알 수 있다.

  • PDF

Performance characteristics of inline mixing and coagulation system (인라인 혼화 및 응집 시스템의 성능특성)

  • Kim, Dong-Jun;Park, Sang-Kyoo;Yang, Hei-Cheon
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.3
    • /
    • pp.269-275
    • /
    • 2014
  • The objective of this study was to investigate the performance characteristics of an inline mixing and coagulation system for water treatment based on the process intensification concept. Three-stage inline mixing and coagulation system was composed of the reservoirs of source wastewater, the fixed quantity injection pumps of coagulants, the mixing and coagulation tubes, a sedimentation tank and a control panel. In the equal dosage of coagulant and coagulant aids, the turbidity removal with increasing the dosage of coagulant aids was about 3 times higher than that with increasing the dosage of coagulant. In the condition of the equal mixing and coagulation time, the turbidity removal of inline mixing and coagulation system was about 4.6 times higher than that of mechanical type.

Remediation of Acid Mine Drainage from an Abandoned Coal Mine Using Steel Mill Slag, Cow Manure and Limestone (제강슬래그, 우분 및 석회석을 활용한 폐 석탄광의 산성광산배수 처리)

  • Jung Myung-Chae
    • Journal of Soil and Groundwater Environment
    • /
    • v.10 no.3
    • /
    • pp.16-23
    • /
    • 2005
  • In order to remediate acid mine drainage (AMD) from the Jeongam coal mine, steel mill slag, cow manure and limestone were used. As a result of batch test, the proper amounts for treating 1 L of acid mine water from the mine were determined as 15 g of steel mill slag, 15 g of cow manure and 500 g of limestone. After feasibility test, remediation system was arranged in the order of steel mill slag tank combination of cow manure and limestone, precipitation tank and oxidation tank. During 54 days' operations, the pH values of the treated waters increased from 3.0 to 8.3 and 61 % of sulfate concentration in an initial water was decreased. In addition, the removal efficiencies for metals in the water were nearly 99.9% for Al, Fe, Zn and 92.6% for Mn. Thus, the combination of steel mill slag, cow manure and limestone can be used as neutralization 때d metal removal for acid mine drainage.