• Title/Summary/Keyword: 친환경 건물

Search Result 128, Processing Time 0.028 seconds

Recent Research Trends for Green Building Thermal Insulation Materials (친환경 건축물 단열재 최근 연구 동향)

  • Park, Jong-Moon;Kim, Dong-Hwan;Suh, Dong-Jin
    • Clean Technology
    • /
    • v.18 no.1
    • /
    • pp.14-21
    • /
    • 2012
  • The pros and cons of green building thermal insulation materials and systems have been reviewed from traditional thermal insulation materials such as mineral wool and polyurethane to new thermal insulation materials like VIP and aerogel and future insulating VIM and DIM. VIPs and aerogels with very low thermal conductivity can use for green buildings to significantly increase residential area by reducing energy consumption. Aerogels can be produced as not only opaque and but also translucent forms, thus enabling a wide range of possible building application. For building applications, there are many properties to consider like building site adaptability and mechanical strength, fire protection, cost and environmental impact.

A Study of Sustainable Architectural Design Elements Based on the Classification of Natural Elements (자연요소 중심으로 분류한 친환경 건축계획 요소에 관한 연구)

  • Yim, Su Hyun;Park, Hyeon Soo
    • KIEAE Journal
    • /
    • v.10 no.5
    • /
    • pp.3-12
    • /
    • 2010
  • Sustainable design is getting to be controversial issue in all industries over the world particularly, in architecture as the amount of energy usage in architecture occupies 40%. Therefore, it is essential to make the standard for the sustainable design. In order to construct the sustainable design, firstly it should be considered that sustainable design elements based on natural resources to increase building energy efficiency is established and classified. The method of sustainable design divides into passive design and active design. Passive design method should be examined with active one simultaneously for more efficient usage of energy. Next, the study is followed how the sustainable design elements is adopted in buildings through the comparison of cases study of domestic and oversea. The result of case study shows similar adoption of sustainable design elements between oversea and domestic. However, the difference is shown in the building orientation and shape and the window size and position in Solar energy as well as high performance structure in Heat energy. These elements are the most significant elements in order to reduce energy load. In oversea, sustainable design is generated by architects, a client, and consultants based on the close cooperation in the beginning of early design phase before deciding building shape and envelope while in the domestic field adoption for sustainable design is conducted after deciding building shape and material. In order to design sustainable architecture more study is necessary in early stage for Zero Carbon and reducing building energy load through relation with specialists, a client and architects.

Market Acceptability of the ZEB Certification System for Public Buildings According to the 2025 Roadmap (2025년 의무화 로드맵에 따른 공공시설 제로에너지건축물 인증제도 시장 수용성)

  • Lee, Seung-Min;Kim, Jin-Ho;Shin, Gwang-Su;Kim, Eui-Jong
    • Journal of Korean Institute of Architectural Sustainable Environment and Building Systems
    • /
    • v.12 no.6
    • /
    • pp.557-566
    • /
    • 2018
  • The ZEB certification system has come into effect since 2018 according to the ZEB road map. From 2020, the public buildings with the total floor area smaller than $3000m^2$ are the target of the certification, and it will be extended to the buildings with up to $5000m^2$ floor area in 2025. However, current mandatory regulations for public office buildings seem already to meet the ZEB certification system planned for 2025. In this work, two buildings belong to $3,000{\sim}5,000m^2$ in total floor area were selected to analyze the possibility of meeting the ZEB certification only by following current obligation regulations. Results showed that the test buildings satisfied the minimum building energy efficiency and energy self-sufficiency rates for the ZEB certification when the mandatory insulation and installation ratio of renewable energy are applied. This can be useful for revising the road map or extending the target buildings of the ZEB certification.

An Operation Status Analysis of Library Building using BEMS Data; Energy Performance Evaluation on Initial Stage of Completion (BEMS 데이터를 활용한 도서관 건물의 운전현황 분석 -준공 초기단계의 건물 에너지 성능 평가)

  • Park, Seong-cheol;Ha, Ju-wan;Kim, Hwan-yong;Song, Young-hak
    • Journal of Korean Institute of Architectural Sustainable Environment and Building Systems
    • /
    • v.12 no.6
    • /
    • pp.669-679
    • /
    • 2018
  • Energy consumption savings in buildings should be reviewed in diverse areas such as air conditioning system and lighting responsible for cooling and heating, and energy management systems such as BAS (Building Automation System) and BEMS (Building Energy Management System) are introduced to improve energy consumption efficiency and to promote economic control of related facilities by integrated management of energy generated and consumption in buildings. The measured building of this study uses regenerative geothermal system. Measured values of heat pump and system COP were 4.7 and 4.2 respectively, and they were found to be higher 11.9% and 23.5% than rated values. As a result of analyzing the air conditioning and lighting energy from the first floor to the fourth floor performing the air conditioning, the second and third floors, which have a high frequency of use, are compared with the first and fourth floors 50% higher energy consumption ratio. On the other hand, the general heat storage system uses the nighttime power of the previous day to store heat and use it the next day. The total number of days of abnormal operation during the summer season is 61 days. The electricity cost corresponding to the abnormal operation is 1,840,641 KRW, and the normal operation using the nighttime power is 1,363,561 KRW, which is difference of 477,080 KRW, 35% increase in cost. We will utilize it as the main data of BEMS through analysis of winter operation characteristics as well as summer operation characteristics.

Loess(Yellow Soil) Finishing Materials Using Water-based Adhesive for Wooden Construction Indoor Wall (수성접착제를 이용한 목조주택 내벽용 황토 마감재의 물성 및 친환경성)

  • An, Jae-Yoon;Kim, Ki-Wook;Kim, Sumin;Oh, Jin-Kyoung;Kim, Hyun-Joong;Park, Moon-Jae
    • Journal of the Korean Wood Science and Technology
    • /
    • v.35 no.6
    • /
    • pp.100-107
    • /
    • 2007
  • People have spent lots of time inside building about 90% of these day. Industry has been developed rapidly after I960. Construction materials had changed from natural materials to chemical materials and confidentiality of building has been more higher than before by policy of saving energy. These have caused sick-building syndrome (SBS) for us. So people want environmental construction materials for their house. We designed a environmental loess (yellow soil) finishing material which was composed of loess, water, water-soluble resin, hardener and filler. The purposes of this study were that making an environmental loess finishing material with optimum ratio, evaluating the usability of loess finishing material for wall. Furthermore it was suitable for wall to evaluate mechanical properties that are impact test, cracking test, abrasion test and de-bonding test, environmental properties that were emission of VOCs, formaldehyde and far infrared radiation.

Suggestion of Thermal Environment Miniature for Evaluation of Heating Efficiency Based on Thermal Conductivity Measurement Method of Building Materials (건축재료의 열전도율 측정방법에 의한 바닥재 난방효율 평가용 열환경 모형 제안)

  • Jeon, Ji-Soo;Seo, Jung-Ki;Kim, Su-Min
    • Journal of the Korean Wood Science and Technology
    • /
    • v.39 no.3
    • /
    • pp.269-280
    • /
    • 2011
  • Today, global warming is one of main problems all over the world. The cause of the global warming is carbon dioxide outbreak by the rapidly increasing energy use. Therefore, it is necessary to save energy in each industrious field. It was investigated that the half of total energy consumption over the world was used for construction and building. Therefore, the saving of the building energy plays a significant role in decreasing total energy consumption. With the considerable increase in building energy consumption, a green building rating system and certification are required to reduce building energy consumption and $CO_2$ emissions. Of various elements reducing building energy, the thermal conductivity of materials affects the energy consumption as a basic element, which is directly related with reducing energy consumption. In particular, as the thermal conductivity of finishing materials is an important factor to decide heating energy efficiency of floor heating system, the investigation and development are necessary.

Indoor Visual Environmental Estimate Experiment Evaluation of See Through BIPV Curtainwall System (가시성확보 BIPV 커튼월시스템의 실내 시환경 예측 시험 평가)

  • Cha, Kwangseok;Jo, Boram
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.108-108
    • /
    • 2011
  • 공동주택에서 2025년 정부가 추진하고 있는 Zero Energy 건축물 구현과 친환경에 대한 탄소배출 저감 문제로 재생에너지 생산시스템의 추가 적용은 반드시 필요하다. 따라서 공동주택 적용 및 활용성을 높일 수 있는 BIPV시스템 개발을 통하여 설치면적 확보와 세대 활용성을 높일 수 있도록 하는 것이 필요하다. 특히 거실 창호의 경우 주방향이 남향, 남동 또는 남서향으로 배치되어 태양광을 적용하기에 적합한 특성을 가지고 있다. 그러나 창호는 건물외피의 역할과 재실자가 조망과 정보취득을 얻을 수 있는 중요한 통로가 되기 때문에 단열 문제나 시야 차폐의 문제는 발생하지는 않도록 하는 것이 필요하다. 본 연구에서는 a-si타입 모듈 2개를 10% 투과율로 Bsck Coating 색상을 달리한 모듈과 c-si BIPV 모듈을 커튼월 창호시스템으로 개발, 일반 2중 창호시스템과 비교 평가를 위해 실제 Test bed 건물에 시공하여 시환경 및 실내 창측면 온도변화 측정 분석을 진행하였다. 현재 국내외 출시되고 있는 a-si see through 모듈은 10~30%의 투과율로 창 마감재로 대체가 가능하나 건축 환경(시환경,열환경)에 대한 분석은 전무한 상태이다. 본 연구에서는 시환경과 창유리면의 열 부하, 자외선, 적외선 차폐 및 가시광선의 투과율에 대한 평가와 Back Coating에 따른 색온도 평가를 통해서 a-si BIPV의 공동주택 세대 발코니 창호 적합성에 대한 검토를 진행하였다. 연구결과는 아래와 같다. ${\bullet}$ 실내조도는 청천공 정오기준 가시성 확보 모듈의 경우 2,300 ~ 3,500lx를 나타내고 있어 대비 현상이나 창측의 급격한 조도 변화가 적은 시환경 구축이 가능 ${\bullet}$ 12시경 휘도는 창측면, 실내 벽체, 코너 바닥면을 대상으로 a-si BIPV 모듈을 적용한 경우 휘도비가 12:1로 KS나 IESNA의 광원과 근접면의 비 20:1 범위에 모두 존재, 적합한 것으로 분석되었으나 c-si의 경우는 그림자로 인한 대비 현상이 발생, 작업 시환경 문제 발생. ${\bullet}$ 이중시스템 창호와 비교하여 단열 성능 떨어짐. 발전시간대 창유리 면 온도 상승 으로 하절기 냉방부하 증가. ${\bullet}$ 자외선은 100% 가까이 차단, 적외선은 13~42%만 투과되고 가시광선은 13% 투과율을 나타내어 일반 창에 칼라 코팅을 적용하는 것과 유사한 경향을 나타냄.

  • PDF

A Study on the Effect of Photocatalyst Coating to Improve the Indoor Air Quality in Buildings (건축물 실내 공기질 향상을 위한 광촉매 코팅 효과에 관한 연구)

  • Park, Hyeon-Ku;Kim, Jong-Ho;Go, Seong-Seok
    • Journal of the Korean Society of Safety
    • /
    • v.21 no.2 s.74
    • /
    • pp.150-157
    • /
    • 2006
  • Sick Building Syndrome (SBS) is an illness symptom such as irritation of eyes, skin eruption and vomit ing in newly constructed buildings. It is mainly due to the harmful gases from the materials installed in building such as Volatile Organic Compounds (VOCs), Semivolatile Organic Compounds (SVOCs), floating bacteria, fungi, fungal spores and viruses, human bioeffluents in many modem buildings. The general ways to improve the Indoor Air Quality (IAQ) are ventilating, utilizing eco-material without harmful gases and reducing or removing harmful gases through additional treatment to the building materials. This study aimed to improve the Indoor Air Quality(IAQ) by applying surface coating on the building materials and to make safe living environments through the analysis of air quality before and after surface coating treatment in buildings.

University Green Campus Policy & Evaluation Criteria -Focus on Comparison of Korea, US AASHE, UNEP & ISCN-GULF- (대학 그린캠퍼스 정책과 평가기준에 관한 연구 -한국, 미국 AASHE, UNEP & ISCN-GULF 간 비교를 중심으로-)

  • Oh, Joon-Gul;Yeom, Dae-Bong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.5
    • /
    • pp.577-586
    • /
    • 2018
  • In Korea, sustainability is mandatory in every field. University campuses are educational facilities that consume considerable amounts of energy. Therefore, many universities have tried to take advantage of the last opportunity to prepare students with sustainability and leadership. This study compared the green campus policy and evaluation criteria among Korea, US AASHE, UNEP, and ISCN-GULF to vitalize the green campus movement and suggest recent research data for the Korea green campus accreditation. The results are as follows: 1. new evaluation criteria need to be added to the certified green building total floor area ratio instead of adapting the G-SEED system in the Campus Resource & Environments category; 2. Korean Green Campus Evaluations need to be improved when expressing the campus individuality by choosing an increased number of credits and criteria; and 3. new evaluation criteria are required to secure the result, feedback, and products from curriculum updates in the Campus Education category.

Effect of Application of Composted Cattle Manure on Forage Productivity in Double Cropping System of Italian Ryegrass - Whole Crop Rice (이탈리안 라이그라스 및 총체 벼 2모작 작부체계에 있어서 우분퇴비 시용이 사료작물의 생산성에 미치는 영향)

  • Jung, Min-Woong;Lim, Young-Chul;Yoon, Sei-Hyung;Choi, Ki-Choon;Kim, Meng-Jung;Kim, Won-Ho;Lee, Ki-Won;Yook, Wan-Bang
    • Journal of Animal Science and Technology
    • /
    • v.53 no.5
    • /
    • pp.469-474
    • /
    • 2011
  • This study was conducted to investigate the effects of application of composted cattle manure (CCM) on the productivity of the whole crop rice (WCR) and Italian ryegrass (IRG) on both Sancheong and Asan area from 2005 to 2008. Application levels of CCM such as chemical fertilizer (CF), CCM 150% and CCM 200% were tested in paddy field. Amount of CCM was adjusted equal to total nitrogen value relative to its value of CF. Mean dry matter yield (DMY) of WCR and IRG increased in order; CCM 200% > CF > CCM 150% in Asan and there was no significant difference between CCM 200% and CF. In Sancheong, DMYs of WCR and IRG significantly decreased (p<0.05) in order CF > CCM 200% > CCM 150%. The plant length and number of tiller of WCR were not different among treatments, however the percentage of ripeness of WCR was higher (p<0.05) in CF compared to CCM 150% and CCM 200%. Also, there were no differences in NDF and ADF contents, however CP content was higher (p<0.05) in CF treatment compared to CCM 150% and CCM 200%. Based on the results of this experiment, IRG-WCR double cropping system with application of CCM may be effective in producing the forage resources of 18~20 tons every year with eco-friendly way.