• Title/Summary/Keyword: 치회전

Search Result 500, Processing Time 0.022 seconds

A Study on ARC Therapy of 18MeV Linear Accelerator (18MeV 선형가속기의 ARC Therapy에 관한 고찰)

  • Kim, Sung-Kyu;Shin, Sei-One;Kim, Myung-Se
    • Journal of Yeungnam Medical Science
    • /
    • v.5 no.2
    • /
    • pp.31-36
    • /
    • 1988
  • In recent years there has been a growing interest in all forms of rotational therapy, and many different types of therapy machines designed for this kind of treatment have become available. To the medical radiation physicist, the dosimetry of rotation therapy has presented a number of interesting problems, and much useful work has been published on the basic data of dose distribution and dosage calculation. The setting dose for ARC therapy were obtained by computer calculation and measurement with cylindrical phantom. Authors compared computer calculation with measured value. And in ARC therapy, the region of maximum dose is shifted from the tumor center. The extent of shift was analyzed by isodose distribution for ARC therapy techniques.

  • PDF

Vibration Analysis of Rotating Thin Shells of Revolution by Finite Element Method (유한요소법에 의한 회전하는 얇은 축대칭 셸의 진동에 관한 연구)

  • 김현실;이영환
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.9 no.4
    • /
    • pp.487-496
    • /
    • 1985
  • 회전하는 축대칭 얇은 셸구조물의 진동 특성을 유한요소법에 의하여 해석하였다. 2개의 절점을 가진 Conical Frustrm 형태의 축대칭 요소를 사용하였으며 원주방향의 변위는 Fourier Series로 분해하여서 방정식의 수를 상당히 줄일 수 있었다. Sanders-Koiter의 셸이론을 사용하였으며 진 동 모우드는 회전의 영향을 설명하기 위하여 대칭 및 비대칭 모우드를 모두 고려하였다. Coriolis 행렬을 포함하는 운동방정식에서 고유 진동수를 계산하기 위해서 질량, 강성 및 Coriolis 행렬로 이루어지는 Hermitian 행렬의 Sturm Sequence Property를 이용하였으며, 좁은 밴드를 갖는 대형 행렬에 알맞는 Determinant Search 방법을 확장하여 고유진동수 및 벡터를 구하였다. 원통형 셸에 대하여 정지한 경우 계산한 고유진동수를 실험치 및 이론치와 비교한 결과 잘 일치됨을 알 수 있었다. 여러 가지 회전 속도에 대해서 얻어진 고유진동스를 이론치와 비교한 결과 잘 일치 됨을 알 수 있어\ulcorner며 회전의 영향으로 traveling wave진동의 현상이 나타남을 알 수 있었다.

Structure & Control of Positioning Control System for Underwater Robot Using Gyro (자이로를 이용한 수중로봇 자세제어장치의 구조와 제어)

  • 김준홍
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.657-660
    • /
    • 2000
  • 전력연구원은 원자로 내부에 적용하기 위한 소형경량의 수중로봇을 개발하기 위한 준비작업으로 자이로를 이용한 수중로봇 조향장치를 개발하고 있다 이장치는 자이로 3개를 조합한 모듈을 서보가 회전시켜 일정한 방향으로 서보의 회전속도에 비례하는 회전토크를 발생하도록 고안되었다 발생된 토크는 작용/반작용의 원리에 의해 서보가 부착되어있는 로봇본체에 작용한다. 이장치를 이용하면 수중로봇의 중심에서 Yaw와 Pitch를 제어할 수 있는 토크가 발생하고 좁은 공간에서 신속한 자세변환이 가능하다 본 고에서는 자이로 조향장치의 구조와 이론적 배경 및 시뮬레이션 결과를 소개한다.

  • PDF

THREE DIMENSIONAL FINITE ELEMENT ANALYSIS FOR REACTION TO MOLAR UPRIGHTING SPRING (대구치 직립 스프링 적용시 반작용에 관한 삼차원 유한요소법적 연구)

  • Choe, Yoo-Kyung;Kim, Tae-Woo;Suhr, Cheong-Hoon
    • The korean journal of orthodontics
    • /
    • v.28 no.1 s.66
    • /
    • pp.61-74
    • /
    • 1998
  • The Purpose of this study was to investigate the stress distribution and tooth displacement at the initial phase produced by 5 types of molar uprighting springs using finite element method. The three dimensional finite element model of lower dentition, bone and springs was composed of 5083 elements and 2071 nodes. The results were as follows: 1. In case of helical spring and root spring, intrusion of lower canine and first premolar were observed md distal tipping, translation and extrusion of lower second molar were observed. 2. In case of T-loop, modified T-loop and box loop, intrusion and distal translation of lower second premolar were observed, and the largest crown distal tipping and translation of lower second molar were observed in T-loop and the smallest were observed in box loop. 3. In case of T-loop with cinch-bact crown distal tipping and translation of lower second molar were decreased, but extrusion was also decreased. 4. With increase of activation in T-loop, mesial translation and won distal tipping of lower second molar were increased and edentulous space was closing, but distal translation of second premolar was also increased. 5. With increase of tip-back bend in T--loop, distal tipping and translation of lower second molar were increased, but extrusion was also increased more largely.

  • PDF

Dynamic analysis of spin speed dependent parameter rotor-bearing systems (회전속도 의존 매개변수를 가진 회전체-베어링계의 동적 해석)

  • 홍성욱;이종원
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.12 no.5
    • /
    • pp.976-983
    • /
    • 1988
  • An efficient unbalance response analysis method for rotor-bearing systems with spin speed dependent parameters is developed by utilizing a generalized modal analysis scheme. The spin speed dependent eigenvalue problem of the original system is transformed into the spin speed independent eigenvalue problem by introducing a lambda matrix, assuming the bearing dynamic coefficients are well approximated by polynomial functions of spin speed. This method features that it requires far less computational effort in unbalance response calculations and that the influence coefficients are readily available. In addition, the critical speeds and the corresponding logarithmic decrements can be readily identified from the resulting eigenvalues.

Additional Root of the Primary Maxillary Second Molar Possibly Associated with Displacement and Rotation of the Permanent Successor : Two Case Reports (상악 제2유구치의 부가치근과 함께 관찰된 영구 계승치의 변위 및 회전 : 증례 보고)

  • Ku, Jaewon;Lee, Jewoo;Ra, Jiyoung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.44 no.1
    • /
    • pp.116-121
    • /
    • 2017
  • An additional root of the primary maxillary second molar is rarely observed. Two cases are presented herein, and we discuss a possible association between additional root of the primary maxillary second molar and displacement and rotation of the permanent successor. Investigation of crown morphology enables the detection of a potential additional root of the primary maxillary second molar, and eruption of the permanent successor needs to be examined carefully if an additional root is present. Early extraction of primary molar and space maintenance can be used as a conservative treatment if the premolar germ shows an abnormal eruption pattern.

The Effect of Early Removal of Mesiodens for the Correction of Central Incisor Rotation (정중과잉치 조기 발거에 따른 상악 영구중절치 회전의 개선)

  • Lee, Jueun;Kim, Youngjin;Kim, Hyunjung;Nam, Soonhyeun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.41 no.1
    • /
    • pp.64-71
    • /
    • 2014
  • Mesiodens is defined as a supernumerary tooth in the premaxillary region. It can cause several clinical manifestations in normal eruption and position of adjacent teeth, such as displacement and impaction. Although the mesiodens accompanied by a clinical complication is indicated for removal, the optimal time of mesiodens removal is still controversial. Some authors suggest immediate intervention defining the removal of mesiodens as soon as possible after the first detection. On the other hand, others recommend delayed intervention which denotes the removal of mesiodens after complete root development of adjacent teeth. This case report is presented with three cases of spontaneous correction and proper alignment of rotated maxillary central incisors by extraction of mesiodens when the crowns of rotated incisors were completely formed while the roots of them were at an early developmental stage.

An convergence study on the effect of plaque removal through the number of operations of the electric toothbrushes (전동칫솔의 작동횟수에 따른 치면세균막 제거율에 관한 융합연구)

  • Moon, Kyung-Hui;Lee, Ji-Young;Kim, Jang-Mi
    • Journal of the Korea Convergence Society
    • /
    • v.10 no.2
    • /
    • pp.21-28
    • /
    • 2019
  • The study was to expand the choice of electric toothbrush by number of operations of the plaque removal effect on the tooth surface. Three different toothbrushes were selected for oscillations and pulsations type of electric toothbrush. A is Oral-B D12 (7,600 pulsations), B is Oral-B D16 (20,000 oscillations and a 7,600 pulsations), C is Oral-B D20 (40,000 oscillations and an 8,800 pulsations). In each trial, each tooth was brushed for 2 seconds. For the 10 trials. And each tooth was coated with 1layer, 2layers and 3layers. After the experiment, the plaque removal effect was calculated and analzed using the Image J program(p<0.05). According to the study, C toothbrush had the highest rate of plaque removal effect. Based on this results of the study, dental worker will need to evaluate oral hygiene and recommend appropriate toothbrushes according to oral conditions.

Spatial changes of the maxillary molar following unilateral derotation with the precision TPA (Precision TPA로 회전된 편측 구치 치료시 공간변화에 대한 연구)

  • Kim, You-Sun;Yeh, Seong-Pil;Kang, Dae-Woon;Chun, Youn-Sic;Row, Joon
    • The korean journal of orthodontics
    • /
    • v.34 no.3 s.104
    • /
    • pp.219-227
    • /
    • 2004
  • The purpose of this study was to evaluate the spatial changes of mesial-in rotated maxillary molar and opposite anchor tooth during derotation by the precision transpalatal arch (TPA) with the use of a new typodont simulation system, the Calorific machine system, which was designed to observe the whole process of tooth movement. The maxillary right first molar was used for the anchor tooth and the maxillary left first molar was used for the mesial-in rotated tooth, and the angle of rotation was increased to 20,40, and 60. A passive precision TPA was fabricated and then activated by bending the left arm to 20, 40, and 60. Each experiment was repeated five times under the same conditions and analyzed by ANOVA and Tucky's Studentized Range (HSD) test. In the occlusal plane, when the bending angle of precision TPA was increased, the mesiobuccal cusp of the rotated molar moved more buccally (p<0.001) and less distally (p<0.001) while the distolingual cusp moved in the mesiopalatal direction. In the sagittal plane, the palatal roots of the derotated molar moved mesially (p<0.001). In the traverse plane, the derotated molar showed slight extrusion (p<0.001). The upper right first molar, which was used as an anchor tooth, showed clinically insignificant movement across all three planes.

고정밀도 치차의 새로운 제작기술

  • 편집실
    • Journal of the KSME
    • /
    • v.25 no.4
    • /
    • pp.330-332
    • /
    • 1985
  • 치차(치차장치)는 주어진 회전속도의 동력을 일하기에 알맞는 회전속도의 동력으로 바꾸는 장 치이다. 회전속도 변환장치에는 여러 가지가 있으나 치차가 가장 콤팩트하고 또 정확하다. 이 것을 능가하는 것은 없다. 치차 장치를 고속화시키고 더욱 콤팩트하게하면 진동의 뭍제가 뒤 따른다. 오차가 없는 정밀치차를 사요하고 윤활도 잘 하지 않으면 안된다. 그 외에도 축, 베 어링, 케이싱등 치차주변의 기계요소도 대단히 중요하다.

  • PDF