• Title/Summary/Keyword: 치아상실

Search Result 319, Processing Time 0.023 seconds

The use of granulation tissue for the esthetic implant restoration for missing tooth due to alveolar bone loss (치조골 소실로 발치하게 된 치아의 심미적인 임플란트 수복을 위한 granulation tissue의 활용)

  • Lee, Chang Kyun
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.30 no.1
    • /
    • pp.33-39
    • /
    • 2021
  • When maxillary anterior tooth is extracted due to alveolar bone loss, the augmentation of alveolar ridge is very important for esthetic implant restoration. Because alveolar bone loss increases after extraction, the ridge preservation performed right after tooth extraction is meaningful for esthetic implant restoration. However, no achievement of primary closure during ridge preservation can negatively affect bone regeneration. To overcome this problem, we can use granulation tissue in the extraction socket for primary closure. This case report confirmed that primary closure using granulation tissue resulted in not only ridge preservation but also ridge augmentation by providing an environment more advantageous of bone regeneration than the open wound.

Re-establishment of occlusal plane in a patient with a failed implant prosthesis (실패한 임플란트 보철수복물을 가진 환자의 교합평면 재설정)

  • Kang, Hyeon-Goo;Ko, Kyung-Ho;Huh, Yoon-Hyuk;Cho, Lee-Ra;Park, Chan-Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.2
    • /
    • pp.141-153
    • /
    • 2018
  • A non-physiological occlusal plane caused by continuous tooth loss, occlusal wear, and failure of a prosthesis may result in an unattractive appearance and functional problems, such as reduced masticatory efficiency and occlusal interference. Therefore, when undertaking prosthetic treatment for edentulous patients or patients with a collapsed occlusal plane, it is important to establish an occlusal plane that is compatible with masticatory function. The patient in this case report had undergone restoration of a completely edentulous maxilla using an implant-supported fixed prosthesis. On follow-up examination in the following 6 years, mechanical complications were observed in the existing implant prosthesis, including porcelain chipping, occlusal wear, and screw loosening. Moreover, due to occlusal wear and supraeruption of the opposing anterior teeth, as well as loss of some posterior teeth, the occlusal plane had collapsed. Following diagnosis, the patient underwent full mouth rehabilitation, involving additional implant installation in edentulous sites, recreation of the existing prosthesis, and prosthetic restoration of all remaining teeth.

PROGNOSIS OF THE SURGICALLY REPOSITIONED MAXILLARY CENTRAL INCISOR IN INTRUSIVE INJURY (함입된 상악 중절치의 외과적 재위치 후 예후)

  • Min, Sung-Jin;Ryu, Jung-Ah;Kim, Seong-Oh;Lee, Jae-Ho;Choi, Byung-Jai;Son, Heung-Kyu;Choi, Hyung-Jun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.33 no.3
    • /
    • pp.522-528
    • /
    • 2006
  • When tooth is displaced within the alveolar bone, it could apply pressure and rupture the apical vessels. Pulpal reaction in such case is affected by the stage of root formation, amount of intrusion and pulpal infection. Determining the need of pulp treatment depends on the pulp vitality. Therefore, periodic vitality tests, coronal color changes and radiographic root resorption signs should be observed through periodic post-trauma follow-up. Pulp necrosis, pulp canal obliteration, external root resorption, root ankylosis and marginal bone loss could result from periodontal injuries. Negative sign changes from positive signs of vitality tests suggest pulp necrosis. In this case, pulp treatment should be held before root resorption occurs. By comparing the following two cases, complications of intrusion and factors producing them could be confirmed, thus we propose to report these two cases.

  • PDF

Accuracy of the CT guided implant template by using an intraoral scanner according to the edentulous distance (구강스캐너를 이용하여 제작된 CT 가이드 임플란트 수술용 형판의 무치악 거리에 따른 정확도 분석)

  • Kang, Byeong-Gil;Kim, Hee-Jung;Chung, Chae-Heon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.1
    • /
    • pp.1-8
    • /
    • 2017
  • Purpose: The purpose of this study is to compare the accuracy of the CT guided implant template that was produced by using an intraoral scanner according to the edentulous distance. Materials and methods: Five maxillary casts were fabricated using radiopaque acrylic resin with the second premolars, first molars, and second molars missing. Then a virtual cast was acquired by scanning each resin cast. Implant treatment was planned on the missing sites by superimposing the presurgical CT DICOM file and the virtual cast. Then the implants were placed using a surgical template followed by postsurgical CT scan. The distance and angle of the platform and apex between the presurgical implant and postsurgical implant were measured using the X, Y, and Z axis of the superimposed presurgical CT and postsurgical CT via software followed by statistical analysis using Kruskall-Wallis test and Mann-Whitney test. Results: The implant placement angle error increased towards the second molars but there was no statistically significant difference. The implant placement distance error at the platform and apex also increased towards the second molars and there was a statistically significant error at the second molars. Conclusion: Although the placement angle had no statistically significant difference between the presurgical implant and postsurgical implant, the placement distance at the platform and apex showed a larger error and a statistically significant difference at the second molar implant.

Full mouth rehabilitation of the patient with severe tooth erosion using collarless porcelain fused to gold restorations: a case report (Collarless 금속 도재 보철물을 이용한 심한 erosion 환자의 전악수복 증례)

  • Song, Hee-Jin;Lim, Young-Jun;Kwon, Ho-Beom;Kim, Myung-Joo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.4
    • /
    • pp.324-329
    • /
    • 2012
  • Excessive tooth wear causes loss of tooth structure, disharmony of occlusal plane, functional and esthetic problems. Although the decrease of occlusal vertical dimension may be compensated by growth of alveolar bone, if the length of tooth is not enough for the retention of restoration, minimum increase of occlusal vertical dimension is required without discomfort of the patient. In this case, 33-year-old woman drinks more than 1 liter of soft drinks a day and has bruxism in night time, visited in Seoul National University Dental Hospital with chief complaint of generalized tooth wear and related esthetic and functional problems. It was considered as a loss of occlusal vertical dimension based on the accelerated tooth wear caused by erosion and bruxism and facial appearance, phonetic, esthetic, functional evaluations. It was planned to raise occlusal vertical dimension by provisional restoration two times for patient's adaptation, 3 mm and 2 mm each, total 5 mm. Confirming no discomfort and clinical symptom during total 16 weeks after restoration with provisional fixed restoration, it was restored with porcelain fused to gold crown and bridge. Because the patient was young woman, anterior teeth were restored with collarless porcelain fused to gold crown. This case presents that satisfactory esthetic and functional result by full mouth rehabilitation with increase of occlusal vertical dimension.

Using implants for worn dentition with the altered vertical dimension of occlusion based on shortened dental arch concept: a case report (과도한 마모를 보이는 환자에서, 임플란트를 활용해 수직 고경을 증가시키며 shortened dental arch 개념을 적용한 보철 수복 증례)

  • Lee, Jae Hyun;Kim, Tae Su;Lee, Chul Won;Lee, Won Sup;Lee, Su Young
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.1
    • /
    • pp.49-56
    • /
    • 2016
  • Excessive occlusal wear can result in unacceptable damage to the residual teeth structure, anterior guidance and masticatory function. An 86-year-old man presented with worn dentition and anterior deep bite due to loss of the posterior support. Two implants covered by Korean national health insurance, fixed partial denture and direct composite resin were used to restore the dentition, instead of removable prosthesis. The occlusal vertical dimension was increased by 2 mm in the premolar area and shortened dental arch concept was applied. This treatment was a less expensive alternative to full-mouth rehabilitation with positive esthetic and functional outcomes after 7 months of follow-up.

RESTORATION OF MISSED MAXILLARY CENTRAL INCISOR USING AUTOTRANSPLANTATION OF MESIODENS : A CASE REPORT (정중과잉치의 자가이식을 통한 상실된 상악 중절치의 수복 : 증례보고)

  • Kim, Hye-Kyoung;Park, Ho-Won;Lee, Ju-Hyun;Seo, Hyun-Woo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.34 no.3
    • /
    • pp.519-525
    • /
    • 2007
  • Supernumerary tooth is developed from overgrowth of dental laminar and is mainly observed in the maxillary anterior area, named 'mesiodens. Mesiodens cause many problems such as malposition of permanent anterior tooth, diastema, formation of cyst, and eruption to oral or nasal cavity. Extraction, therefore, is generally recommended choice of treatment. This case report describes that the patient is a 9 years and 8 months old boy, whose unilateral maxillary incisor was missing due to trauma, and he had a mesiodens. We practiced autotransplantation of the mesiodens to the missing maxillary central incisor area and then restored with prosthetics, substantially kept out alveolar bony resorption and provided esthetic appearance. Mesiodens was too small to be used as an abutment because its length is totally 14mm, so that poor prognosis was anticipated due to bad crown/root ratio. However, we observed clinically acceptable result during the observation period of 8 months after operation.

  • PDF

Zirconia resin-bonded fixed partial denture in maxillary single-tooth edentulous area: A case report (상악 전치부 단일치 상실 환자에서 지르코니아 레진접착성 고정성 국소의치를 이용한 수복 증례)

  • Rojee Oh;Hee-Won Jang;Na-Hong Kim;Joo-Hyuk Bang;Keun-Woo Lee;Yong-Sang Lee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.2
    • /
    • pp.135-142
    • /
    • 2023
  • Resin-bonded fixed partial denture (RBFPD)as known as Maryland bridge is is a well-known conservative method for its minimized invasion of the teeth for an anterior single tooth edentulous area. Despite of its various advantages, RBFPD was not widespread because of its high debonding rates, non-esthetic look or weak structure for material property. Currently, with the introduction of zirconia to dental material for RBFPD, Maryland bridge entered upon a new phase. Zirconia surmounts poor esthetics of metal framework, having proper strength, and overcomes ceramic's structural weakness, being sufficiently esthetic. In this case, edentulous area of maxillary left lateral incisor was restored using zirconia resin-bonded fixed partial denture. Restoration of missing tooth in anterior area was achieved using non-invasive and esthetic prosthesis, then we report this case as satisfactory results were obtained for both the operator and the patient.

Ultrasonographic study on the masseter muscle thickness of adult Korean (한국인 성인의 교근 두께에 관한 초음파검사적 연구)

  • Cha, Bong-Kuen;Park, In-Woo;Lee, Yeun-Hee
    • The korean journal of orthodontics
    • /
    • v.31 no.2 s.85
    • /
    • pp.225-236
    • /
    • 2001
  • It is widely accepted that the shape and structure of bone are closely related to the activity of attached muscle. Numerous clinical and animal experimental studies indicated the significant effects of masticatory muscle function on maxillofacial morphology. Recently, the development of ultrasonography has spread throughout different fields of medicine. In the clinical examinations, ultrasonography is a convenient, inexpensive technique to apply with accurate and reliable results. The aim of this study is to assess the thickness of the masseter muscle and its correlation to maxillofacial skeleton by examining 35 male and 15 female dental students at Kangnung National University. The masseter muscle thickness of the subjects were measured by ultrasonographic scanning with a 7.5MHz linear probe, and their maxillofacial morphology were investigated by lateral cephalometric radiographs. The relationship between the masseter muscle thickness and maxillofacial morphology of normal adult was statistically analyzed, and the following results were obtained. 1. The average thickness of male masseter muscle was 13.8${\pm}$1.71mm in the relaxed state and 14.8${\pm}$1.77mm at maximal clenching state, while that of female was 11.6${\pm}$1.58mm and 12.4${\pm}$1.47mm, respectively. Ethnic difference in thickness of the masseter muscle and maxillofacial skeleton was found when the results of many researchers were compared with those of this study. 2. The thickness of the masseter muscle in both sexes increased significantly at maximal clenching state than in relaxed state(P<0.05). 3. The masseter muscle thickness of male was greater than that of female both in the relaxed state and maximal clenching states(P<0.05). 4. In males, the thickness of the masseter muscle was negatively correlated with the mandibular plane angle and positively correlated with the mandibular ramus height and anterior cranial base length(P<0.05). It may suggest that the male with thicker masseter muscle has smaller facial divergence. 5. No significant correlation was found between the masseter muscle thickness and maxillofacial morphology in females(P<0.05). Therefore, these data suggest that ultrasonography can add valuable information to the conventional examinations of masseter muscle function.

  • PDF

PULP VITALITY TEST OF TEETH AFTER TRAUMATIC INJURIES USING LASER DOPPLER FLOWMETRY - A CASE REPORT (외상 받은 치아의 치수생활력 검사 - Laser Doppler flowmetry를 이용한 증례보고)

  • Song, Yun-Ju;Kim, Hyun-Jung;Nam, Soon-Hyeun;Kim, Young-Jin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.26 no.2
    • /
    • pp.310-316
    • /
    • 1999
  • In the traumatized teeth, the major complications are pulp necrosis, and root resorption. The factors influencing to prognosis are the state of root development, type of injuries, quality of fixation. There are good prognosis in the case of immature teeth, minor luxation injuries. To minimize of occurrence of these complication, it is very important to determine the pulp vitality. This can help us decide whether or not to treat the teeth endodontically. But, it is difficult to determine of pulp vitality in immature teeth or traumatized teeth. In this case, pulp vitality test was done periodically on the traumatized upper central incisors, and the results were different among cold test, electric pulp test, and laser Doppler flowmetry. The conclusions were obtained from this case can be summarized as follows; 1. Pulp vitality of traumatized teeth should be negative early, but with time going, pulp vitality could be recovered. 2. The positive response of pulp vitality test was detected earlier in laser Doppler flowmetry. 3. Between cold test and electric pulp test, cold test was more reliable in determining pulp vitality.

  • PDF