• 제목/요약/키워드: 치아모형

검색결과 218건 처리시간 0.025초

Tooth size and arch parameters of normal occlusion in a Iarge Korean sample (한국인 정상교합자의 치아크키와 치열궁 계측치에 관한 연구)

  • Lee, Shin-Jae;Moon, Seong-Cheol;Kim, Tae-Woo;Nahm, Dong-Seok;Chang, Young-Il
    • The korean journal of orthodontics
    • /
    • 제34권6호
    • /
    • pp.473-480
    • /
    • 2004
  • The aim of this study was to establish normative data on the tooth size and arch parameters of Koreans with normal occlusion, This study employed the dental casts of 296 (male: 179; female 117) normal occlusion samples, who were selected from 15,836 adults through a community dental health survey. The mesiodistal diameters of teeth, arch width, and arch length were measured by digital electronic calipers(accurate to 0.01 mm) and Bolton's indices as well as intermaxillary arch width ratios were calculated. In order to ensure reliability, intra- and inter-examiner error were evaluated. Although our dimensional data showed overt differences between genders, the indices and intermaxillary ratios evaluated were the same. The resultant data obtained were compared with the previous data to reveal whether any changes have occurred over the time. The clinical implication of the present findings was also discussed. This biometric study seemed to provide a clinically applicable diagnostic criteria for an individual malocclusion patient.

Time efficiency and operator convenience of using a micro-screw in image registration for guided implant surgery (마이크로스크류가 가이드 임플란트 수술을 위한 영상정합 과정에서 작업시간과 술자편의성에 미치는 영향)

  • Mai, Hai Yen;Lee, Du-Hyeong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • 제57권3호
    • /
    • pp.219-224
    • /
    • 2019
  • Purpose: The image registration of radiographic image and digital surface data is essential in the computer-guided implant guide system. The purpose of this study was to examine the effects of using micro-screw on the working time and convenience of operators in the process of image matching for guided implant surgery. Materials and methods: A mandibular dental model was prepared in partial edentulism for Kennedy class I classification. Two micro-screws were placed on the each side of retromolar area. Radiographic and scan images were taken using computed-tomography and digital scanning. The images were superimposed by 12 operators in software in two different conditions: using remaining teeth image alone and using teeth and micro-screws images. Working time, operator convenience and satisfaction were obtained, and analyzed using the Mann-Whitney U test (${\alpha}=.05$). Results: The working time was not statistically different between image registration conditions (P>.05); however, operator convenience and satisfaction were higher in the teeth and micro-screw assisted condition than in the teeth-alone assisted condition (P<.001). Conclusion: The use of micro-screw for the image registration has no effect in working time reduction, but improves operator convenience and satisfaction.

Three-dimensional finite element analysis of initial tooth displacement according to force application point during maxillary six anterior teeth retraction using skeletal anchorage (골격성 고정원을 이용한 상악 6전치 후방 견인시 힘의 적용점 변화에 따른 치아 이동 양상에 관한 유한 요소법적 분석)

  • Kim, Chan-Nyeon;Sung, Jae-Hyun;Kyung, Hee-Moon
    • The korean journal of orthodontics
    • /
    • 제33권5호
    • /
    • pp.339-350
    • /
    • 2003
  • The purpose of this study was to investigate the micro-implant height and anterior hook height to prevent maxillary six anterior teeth from lingual tipping and extruding during space closure. We manufactured maxillary dental arch form, bracket and wire, using the computer aided three-dimensional finite element method. Bracket was $.022'{\times}.028'$ slot size and attached to tooth surface. Wire was $.019'{\times}.025'$ stainless steel and $.032'{\times}.032'$ stainless steel hook was attached to wire between lateral incisor and canine. Length of hook was 8mm and force application points were marked at intervals of In. Four micro-implants were implanted on alveolar bone between second premolar and first molar. The heights of them were 4, 6, 8, 10mm starting from wire. We analyzed initial displacement of teeth by various force application point applying force of 150gm to each micro-implant and anterior hook. The conclusions of 4his study are as the following : 1. When the micro-implant height was 4m and the anterior hook height was 5mm and below, anterior teeth were tipped lingually. When the anterior hook height was 6mm and above, anterior teeth were tipped labially. 2. When the micro-implant height was 6mm and the anterior hook height was 6mm and below, the anterior teeth were tipped lingually. When the anterior hook height was 6m and above, the anterior teeth were tipped labially. But lingual tipping of anterior teeth decreased and labial tipping Increased when the micro-implant height was 6mm, compared with 4mm micro-implant height. 3. When the micro-implant height was 8mm and the anterior hook height was 2mm, the anterior teeth were tipped lingually. When the anterior hook height was 3mm and above, labial tipping movement of the anterior teeth increased proportionally. 4. When the micro-implant height was 10mm and the anterior hook height was 2mm and above, labial tipping of the anterior teeth increased proportionally. 5. As the anterior hook height increased, aterior teeth were tipped more labially. But extrusion occurred on canine and premolar area because of the increase of wire distortion. 6. Movement of the posterior teeth was tipped distally during maxillary six anterior teeth retraction using micro-im plant because of the friction between bracket and were Based on the results of this study, we could predict the pattern of the tooth movement according to position of micro-implant and height of anterior hook. It seems that we can find the force application point for proper tooth movement in consideration of inclination of anterior anterior teeth, periodontal condition, overjet and overbite

The evaluation of rotational movements of maxillary posterior teeth using three dimensional images in cases of extraction of maxillary first premolar (3차원 영상을 이용한 상악 소구치 발치공간 폐쇄 후 상악 구치부 회전양상의 평가)

  • Chong, Deuck-Ryong;Jang, Yen-Ju;Chun, Youn-Sic;Jung, Sang-Hyuk;Lee, Sung-Keun
    • The korean journal of orthodontics
    • /
    • 제35권6호
    • /
    • pp.451-458
    • /
    • 2005
  • Cephalometric superimposition is unable to evaluate tooth movement along the occlusal plane and the errors of photographing and superimposition of the occlusogram is also inevitable. The purpose of the present study was to evaluate the rotational movements of the maxillary posterior teeth following space closure after extraction of maxillary first premolars. using 3D dental images. In 19 adult females. analysis of rotational movements of the maxillary posterior teeth was performed between the initial and final 3D dental images superimposed on the maxillary hard palate. The results showed a diversity of rotational movements of posterior teeth. The causes of various rotational movements may be different rotation of molars in each case at the beginning of treatment. individual characters of the dental arch and tooth morphology. The results of the study indicate that accurate evaluation of rotational movements of posterior teeth following space closure after extraction of premolars using 3D dental images can be obtained through the subdivision of tooth movement during the initial aligning, space closure and finishing stages.

Validity of Arch Relationship Measurements in Digital Dental Models (디지털 치열 모형에서 악궁 관계 지표 측정의 타당성)

  • Ryu, Jiin;Yang, ByoungEun;Lee, Hyelim
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • 제49권1호
    • /
    • pp.14-24
    • /
    • 2022
  • The aim of the present study is to evaluate the validity of orthodontic measurements including tooth width, Bolton ratio, overjet and overbite on the digital dental models. Dental models of the subjects aged 12 to 18 were obtained in 3 different forms, which were conventional stone model, digital model created with Freedom HD model scanner, and digital model produced with CS3600 intraoral scanner. After measurements were made on the models, reliability and reproducibility of the measurements were evaluated by using intraclass correlation coefficient, while validity was assessed with paired t-test. As a result, significant reliability and reproducibility were verified, with intraclass correlation coefficient exceeding 0.750 in all groups. Measurements of the model scanned group showed an adequate validity in overall and anterior Bolton ratio, overjet, and overbite. Intraoral scanned models showed an adequate validity in anterior Bolton ratio, and overjet. Measurement on intraoral scanned digital models can be considered as an alternative for young children who have difficulty in taking impression. Furthermore, careful considerations on measurement error should be made in clinical situations.

Evaluation of Artifacts by Dental Metal Prostheses and Implants on PET/CT Images: Phantom and Clinical Studies (PET/CT 영상에서의 치과재료에 의한 인공물에 관한 연구)

  • Bahn, Young-Kag;Park, Hoon-Hee;NamKoong, Hyuk;Cho, Suk-Won;Lim, Han-Sang;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • 제14권2호
    • /
    • pp.110-116
    • /
    • 2010
  • Purpose: The X-ray attenuation coefficient based on CT images is used for attenuation correction in PET/CT. The polychromatic X-ray beam can introduce beam-hardening artifact on CT images. The aims of the study were to evaluate the effect of dental metal prostheses in phantom and patients on apparent tracer activity measured with PET/CT when using CT attenuation correction. Materials and Methods: 40 normal patients (mean age $54{\pm}12$) was scanned between Jan and Feb 2010. NEMA(National Electrical Manufactures Association) PET $Phantom^{TM}$ (NU2-1994) was filled with $^{18}F$-FDG injected into the water that insert implant and metal prostheses dental cast. Region of interest were drawn in non-artifact region, bright steak artifact region and dark streak artifact region on the same transaxial CT and PET slices. Patients and phantom with dental metal prostheses and dental implant were evaluated the change rate of CT Number and $SUV_{mean}$ in PET/CT. A paired t-test was performed to compare the ratio and the difference of the calculated values. Results: In patients with dental metal prostheses, $SUV_{mean}$ was reduced 19.64% (p<0.05) in the non-steak artifact region than the brightstreak artifact region whereas was increased 90.1% (p>0.05) in the non-steak artifact region than the dark streak artifact region. In phantom with dental metal prostheses, $SUV_{mean}$ was reduced 18.1% (p<0.05) in the non-steak artifact region than the bright streak artifact region whereas was increased 18.0% (p>0.05) in the non-steak artifact region than the dark streak artifact region. In patients with dental implant, $SUV_{mean}$ was increased 19.1% (p<0.05) in the non-steak artifact region than the bright streak artifact region whereas was increased 96.62% (p>0.05) in the non-steak artifact region than the dark streak artifact region. In phantom with dental implant, $SUV_{mean}$ was increased 14.4% (p<0.05) in the non-steak artifact region than the bright streak artifact region whereas was increased 7.0% (p>0.05) in the non-steak artifact region than the dark streak artifact region. Conclusion: When CT is used for attenuation correction in patients with dental metal prostheses, 19.1% reduced $SUV_{mean}$ is anticipated in the dark streak artifact region on CT images. The dark streak artifacts of CT by dental metal prostheses may cause false negative finding in PET/CT. We recommend that the non-attenuation corrected PET images also be evaluated for clinical use.

  • PDF

Corydalis misandra B.U.Oh: A new species of Corydalis sect. Corydalis (Fumariaceae) from Korea (각시현호색: 한국에서 발견된 현호색속 현호색절의 1신종)

  • Oh, Byoung-Un;Choi, Hyeok-Jae
    • Korean Journal of Plant Taxonomy
    • /
    • 제36권2호
    • /
    • pp.137-144
    • /
    • 2006
  • A new species of Corydalis sect. Corydalis (Fumariaceae), C. misandra B.U.Oh, is described from the provinces of Gyonggi-do and Gangwon-do in Korea. The new species is distinct from its close relative C. namdoensis in having elliptic or linear leaflet shape, entire or slightly dentate bract apex, broad and rhomboidal lower outer petal, 14 papillate stigma, oblong stamen and linear capsule with one rowed seeds, etc.

IMMOBILIZATION OF LOWER MANDIBULAR ALVEOLAR BONE FRACTURE USING RESIN-WIRE OPEN CAP SPLINT (하악 유전치부 치조골 골절시 resin-wire open cap splint를 이용한 고정)

  • Kwon, Joung-Hyun;Choi, Byung-Jai;Choi, Hyung-Jun;Kim, Seong-Oh;Son, Heung-Kyu;Lee, Jae-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • 제35권1호
    • /
    • pp.175-180
    • /
    • 2008
  • Traumatic injuries to the primary dentition are commonly encountered problems in dental practice. It is found that 30% of the children had injuries to the primary dentition and 22% to the permanent dentition. The greatest incidence of trauma to the primary dentition occurs at the ages of 2 and 3 as children start to learn motor coordination. Because teeth and alveolar bone are traumatized simultaneously, alveolar bone fractures are likely to occur when multiple teeth are involved in injuries. Dental splints are indicated for the management of maxillofacial fractures. They enable anatomic reduction of fractured segments and help immobilization and maintenance of the fragments after reduction. They also act as a stabilizer during rehabilitation. Various types of dental splints are available. In this case, routine resin-wire splint technique could not be applied because of the child's uncooperative behavior. Oral sedation was not indicated because N.P.O. had not been preceded. Therefore, we decided to use open-cap acrylic splint instead. Stabilization using open cap acrylic splint requires minimum chair time with reduced discomfort to both patient and dentist. It is an effective means of splint for uncooperative children and especially useful when other means of fixation have been failed. Because trauma on the primary dentition can affect the underlying permanent tooth germ, it is important to monitor eruption process of the permanent dentition.

  • PDF

CLINICAL STUDY ON THE ANOMALLES OF NUMBER AND MORPHOLOGY IN CLEFT LIP AND PALATE PATIENTS' TEETH (순구개열환자의 치아 수와 형태 이상에 관한 연구)

  • Baek, Seung-Hak;Yang, Won-Sik
    • The korean journal of orthodontics
    • /
    • 제31권1호
    • /
    • pp.51-61
    • /
    • 2001
  • Cleft lip and/or palate (CLP) is one of the most common congenital craniofacial anomalies and occurs more frequently in Asian people. Dental abnormalities in number, size, shape, and eruption of teeth are frequently associated with CLP. The purposes of this study were to investigate the effects of CLP on number, size, shape and eruption of teeth and to provide basic clinical data for diagnosis and treatment of the CLP patients. With the orthodontic and cleft charts, diagnostic models, orthopantomograms and intraoral x-ray films from 241 CLP patients who visited Dept. of Orthodontics, Seoul National University Dental Hospital, we evaluated the frequency of congenital missing teeth, supernumerary teeth, Impacted teeth, and microdontia. The results were as fellows ; 1. Frequency of congenital missing was relatively high up to $56.8\%$. Congenital missing occurred frequently in the maxillary lateral incisor and the maxillary second premolar. Among the CLP types, frequencies of congenital missing in cleft lip and Palate group and cleft lip and alveolus group were higher than those of cleft lip group and cleft palate group. And bilateral cleft showed higher frequencies than unilateral ones. 2. Supernumerary tooth was shown in $11.2\%$ of CLP patients. It occurred frequently in the area between the maxillary lateral Incisors and the maxillary canine. Among the CLP types, cleft lip group showed relatively most highest frequency. 3. Impaction was shown in $18.3\%$ of CLP patients. It occurred most frequently In the maxillary lateral incisor and the maxillary canine than other teeth. Among the CLP types, cleft lip group and cleft lip and palate group showed most highest frequencies. 4. Microdontia was shown in $15.8\%$ of CLP patients. It occurred the most frequently In the maxillary lateral incisors and maxillary canines. Among the CLP types, cleft lip and alveolus group and cleft lip and palate group showed relatively higher frequencies. There was no microdontia in cleft palate group.

  • PDF

Finite element analysis of the effects of mouthguard produced by combination of layers of different materials on teeth and jaw (다양한 물성을 혼용하여 제작된 구강보호장치가 치아 및 악골에 미치는 영향)

  • So, Woong-Seob;Lee, Hyun-Jong;Choi, Woo-Jin;Hong, Sung-Jin;Ryu, Kyung-Hee;Choi, Dae-Gyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • 제49권4호
    • /
    • pp.324-332
    • /
    • 2011
  • Purpose: The purpose of this study was to compare the stress distribution of teeth and jaw on load by differentiating property of materials according to each layer of widely used mouthguard. Materials and methods: A Korean adult having normal cranium and mandible was selected to examine. A customized mouthguard was constructed by use of DRUFOMAT plate and DRUFOMAT-TE/-SQ of Dreve Co. according to Signature Mouthguard system. The cranium was scanned by means of computed tomography with 1mm interval. It was modeled with CANTIBio BIONIX/Body Builder program and simulated and interpreted using Alter HyperMesh program. The mouthguard was classified as follows according to the layers. (1) soft guard (Bioplast)(SG) (2) hard guard (Duran)(HG) (3) medium guard (Drufomat)(MG) (4) soft layer + hard layer (SG + HG) (5) hard layer + soft layer (HG + SG) (6) soft layer + hard layer + soft layer (SG + HG + SG) (7) hard layer + soft layer + hard layer (HG + SG + HG) The impact locations on mandible were gnathion, the center of inferior border, and the anterior edge of gonial angle. And the impact directions were oblique ($45^{\circ}$). The impact load was 800 N for 0.1 sec. The stress distribution was measured at maxillary teeth, TMJ and maxilla. The statistics were conducted using Repeated ANOVA and in case of difference, Duncan test was used as post analysis. Results: In teeth and maxilla, the mouthguard contacting soft layer of mandibular teeth presented lowest stress measure and, in contrast, in condyle, the mouthguard contacting hard layer of mandibular teeth presented lowest stress measure. Conclusion: For all impact directions, soft layer + hard layer + soft layer, the mouthguard with three layers which the hard layer is sandwiched between two soft layers, showed relatively even distribution of stress in impact.