• Title/Summary/Keyword: 치료 초음파

Search Result 712, Processing Time 0.036 seconds

Usefulness and Limitation of Ultrasonography in the Diagnosis of Septic Arthritis of the Elbow in a Neonate (신생아 주관절 화농성 관절염의 초음파 이용의 제한: 증례 보고)

  • Park, Ji-Hun;Jeon, Woo-Joo;Jeong, Woong-Kyo;Lee, Soon-Hyuck
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.5 no.2
    • /
    • pp.112-117
    • /
    • 2012
  • Septic arthritis of the elbow is a rare, but serious disorder in neonates. However, neonates often present with few systemic signs other than irritability or poor feeding. When the clinical findings are minimal or absent, joint aspiration gives us helpful information in making a diagnosis. Although many clinicians rely on its result, we experienced a case of early clotted joint effusion, which resulted negative joint aspiration in a neonate with septic elbow arthritis. Ultrasonography helped us to make an early decision to perform surgical intervention as showing different echogenicity of intracapsular portion from generally presented in septic effusion. Presenting case shows that ultrasonography can be an excellent second step examination of neonatal elbow presenting atypical clinical findings of septic arthritis.

  • PDF

A Study on the Design of an Annular Array Transducer for Ultrasonic Hyperthermia (초음파 Hyperthermia용 동심환 변환기의 설계에 관한 연구)

  • 조영환;성굉모
    • The Journal of the Acoustical Society of Korea
    • /
    • v.5 no.4
    • /
    • pp.37-45
    • /
    • 1986
  • 초음파 Hyperthermia를 이용한 치료는 정상세포에 열적 손상을 주지 않으면서 종양 부위만을 적당한 온도로 가열하여야 하며 따라서 종양세포와 정상세포에 대한 정확한 초음파 세기조절이 필요하 게 된다. 본 논문에서는 초음파 Hyperthermia 용 변환기로서 초점거리와 가열범위를 전자적으로 쉽게 조절할 수 있는 동심환 배열 변환기를 설계하였으며 컴퓨터 모의 실험을 통해 그 성능을 예측하였다. 설계된 변환기는 유효직경 118mm, 동작주파수 320kHz 이며 배열 요소의 수는 12개이다. 그리고 이와 같은 동심환 변환기를 동작시키기 위해 카운터를 이용한 디지털 위상 조절 회로를 설계 제작하였으며, 실험 결과, 위상차를 갖는 신호를 발생시킬 수 있었다.

  • PDF

Compressive Neuropathy in Upper Extremity (상지의 압박 신경병증)

  • Park, Jong Woong
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.2 no.2
    • /
    • pp.99-106
    • /
    • 2009
  • Compressive neuropathy in the upper extremity can be clinically diagnosed by careful history taking, physical examination of the involved nerve. Electrodiagnosis for the suspected nerve informs severity of compression of the involved nerve and indicates specific site of the lesion. In the early stage of the disease, non-operative treatment generally cures the symptom, however, if the conservative treatment fails, confirmation of the exact site of the lesion should be preceded before the operation. Recently, ultrasonography, as a supportive tool for the diagnosis of compressive neuropathy has increasing popularity for its ability to find space occupying lesion, anatomical change of the nerve, and the pathologic change in the nerve itself. For the successful treatment of the compressive neuropathy, these various diagnostic tools have to be introduced in the orthopaedic clinic.

  • PDF

Ultrasound-guided Extracorporeal Shock Wave Therapy Combined with Multiple Needling for Calcific Tendinitis in Shoulder (견관절의 석회화 건염에 대한 초음파 유도하 다발성 천공술 및 고에너지 체외 충격파 병합치료)

  • Jung, Tae Wan;Song, Dong Ik;Lee, Soon Hyuck;Jeoung, Woong Kyo
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.7 no.1
    • /
    • pp.13-19
    • /
    • 2014
  • Purpose: To evaluate the effectiveness of ultrasonography-guided combined multiple needling and high-energy extracorporeal shock wave therapy (ESWT) for calcific tendinitis of the shoulder. Materials and Methods: We included 42 calcific tendinitis patients who underwent ultrasonograpy-guided multiple needling followed by high-energy ESWT who visited the clinic from January 2010 to June 2013. The average follow up period was 45 weeks. Clinical evaluation was done before and after 12 weeks from treatment, in clinical terms using pain visual analogue scale (P-VAS), ASES, UCLA scores reflecting performance and symptom improvement, and in sonographic terms by studying the changes in size of the calcific nodules. Results: A statistically significant improvement was seen in P-VAS, ASES, UCLA scores and decreased calcification size on sonographic evaluation. Conclusion: Ultrasonography-guided combined multiple needling and high-energy ESWT is considered as a useful method which could provide clinical function improvement and reduction of calcification deposit.

  • PDF

The Estimation of Transient Temperature Distributions in Tumor Model during Ultrasonic Hyperthermia (초음파 Hyperthermia에 의한 종양모델내의 동적 온도분포 추정)

  • 박태연;성굉모
    • The Journal of the Acoustical Society of Korea
    • /
    • v.5 no.4
    • /
    • pp.46-56
    • /
    • 1986
  • Hyperthermia를 사용하여 종양세포를 치료하는데 있어서 시간에 따른 동적 온도분포를 추정하 고 또, 그 온도분포에 관계하는 인자들이 동적 온도특성에 미치는 영향을 살펴보는 것은 실제 치료시에 정확한 온도제어를 위해서 반드시 필요하다. 본 논문에서는 몸속 10cm 깊이에 존재하는 원통형 종양모 델을 설정하고 초음파 동심환 변환기로 열을 집속시켰을 때 동적 온도분포 추정을 위해서 2차원 유한요 소법과 유한차분법을 이용하였다. 결과로서, 동적 온도분포에 가장 큰 영향을 미치는 인자는 혈류량이었 고, 추출된 동적 온도분포 특성값을 가지고 간단한 ON/OFF 온도제어에 적용할 수 있음을 보였다.

  • PDF

Ultrasound-Guided Percutaneous Thrombin Injection of Femoral Artery Pseudoaneurysms Caused by Vascular Access (대퇴동맥을 통한 시술 후 발생한 가성동맥류의 초음파 유도하 경피적 트롬빈 주입 치료)

  • Seung Yoon Chae;Chan Park;Jae Kyu Kim;Hyoung Ook Kim;Byung Chan Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.3
    • /
    • pp.589-599
    • /
    • 2021
  • Purpose To analyze the success and complication rates and factors associated with technical failure of the ultrasound (US)-guided percutaneous thrombin injection of femoral artery pseudoaneurysms caused by vascular access. Materials and Methods Records of 30 patients with post-catheterization femoral artery pseudoaneurysms who had been treated with US-guided percutaneous thrombin injections in the department of radiology between March 2009 and June 2019 were retrospectively analyzed. The lesion was diagnosed based on US or contrast-enhanced CT. The characteristics of the patients and their lesions were analyzed. Results The mean patient age was 67.8 years. The mean diameter of the pseudoaneurysmal sac was 20.88 mm (5-40 mm). Twenty patients (66.6%) obtained complete thrombosis after the primary injection, while 10 patients (33.3%) obtained partial thrombosis. The number of patients with a low platelet count (< 130 k/µL) was significantly higher in the partial thrombosis group than in the complete thrombosis group (p = 0.02). No substantial procedure-related complications were found in any patient. Conclusion The US-guided percutaneous thrombin injection is considered an initial treatment option for pseudoaneurysms caused by vascular access because of its safety and efficacy.

Ultrasonographic Guidance in Acute Achilles Tendon Rupture (급성 아킬레스 건 파열에서의 초음파 이용)

  • Lee, Tae-Hoon;Lee, Hee-Dong;Kim, Hak-Jun
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.8 no.1
    • /
    • pp.26-30
    • /
    • 2015
  • There are many traumatic foot and ankle problems in orthopaedic fields. Though it is not life-threatening problems, a delay in accurate diagnosis and treatments can danger limb function and therefore correct diagnosis can prevent long-term complications. Achilles tendon rupture is relatively common injury for active sports people. Ultrasonography is cost-effective, irradiation -free, effective for evaluation of soft tissues and dynamic analysis. It has been growing importance in Achilles tendon rupture. Ultrasonography is a diagnostic tool in Achilles tendon rupture. Physical examination and patient history is needed to diagnose Achilles tendon without image, but it is missed up by 20% in private clinic. Discontinuity of normal fibrillar architecture seen on an ultrasonographic image is diagnostic for Achilles tendon rupture, and can be accentuated by the performance of dorsi-flexion and plantar flexion, while observing in real time. And ultrasonography is a reliable method for serial observation after surgical treatment or conservative treatment.

  • PDF

The Implementation of TMM test phantom for evaluating the thermal performance in High Intensity Focused Ultrasound system (강력 집속 초음파 시스템의 열적 성능 평가를 위한 팬텀 개발에 관한 기초연구)

  • Yu, Woo-Jin;Noh, Si-Cheol;Park, Moon-Kyu;Min, Hae-Ki;Park, Jae-Hyun;Choi, Heung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2008.10b
    • /
    • pp.484-485
    • /
    • 2008
  • 초음파는 의학적 진단 및 치료의 목적으로 널리 사용되어 왔다. 일반적으로, 초음파 조사의 생물학적 무해성은 많은 연구를 통하여 보고되었으나, 최근 초음파 집속을 통한 강력 초음파의 사용에 대한 열적 안전성 평가가 중요한 요소로 대두되고 있다. 이에 본 연구에서는 강력 집속 초음파의 전달 에너지와 열적 분포를 측정하여 안전성 평가에 활용 가능한 초음파 열분포 팬텀을 제안하였다. 온도 분포 측정용 팬텀은 초음파 조직유사 팬텀 재료인 한천을 이용하였으며, 음향학적 특성의 유사성을 평가하였다. 온도 효과를 측정하기 위하여 $3{\times}3$의 형태로 온도 센서를 팬텀 내부에 배열하여 초음파 조사에 따른 온도 분포를 측정하였고 온도 측정을 위한 시스템을 개발하여, 초음파 가열 실험을 수행하였다. 본 연구에서 제안된 초음파 온도 분포 측정용 팬텀의 유용성을 확인하였으며, 온도 분포용 팬텀을 통한 강력 집속 초음파 장비의 열적 성능 평가에 적용 될 수 있을 것으로 사료되었다.

  • PDF

Anatomy, Biomechanics and Physical Examination of Foot and Ankle (족부 및 족관절의 해부학, 생역학 및 신체 검사)

  • Hur, Chang-Yong;Kim, Hak Jun
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.3 no.1
    • /
    • pp.32-37
    • /
    • 2010
  • Ultrasonographic diagnosis and treatment in Orthopaedic fields had been widely used. Sonographic diagnosis and treatment of foot and ankle is convenient because of anatomical characteristics. The knowledge of the anatomy and biomechanics in foot and ankle area can help to diagnose and treat the disease around foot and ankle. 28 bone and many tendons, ligaments and muscles are consist of ankle and foot joint and the coordinative relation among these structures can allow the dual function, weight bearing and locomotion of ankle and foot during gait cycle. Foot and ankle have small room for many structures, so systemically physical examination is essential for diagnosis. Accurate understanding of foot and ankle anatomy and biomechanics could be helpful to using ultrasonograph.

  • PDF

Design of outside orbit style supersonic waves multi curer for Fracture patient's type (radish stimulation, radish invasion) rehalibitation promotion) (Fracture 환자의 유형(무자극, 무침습) 재활촉진을 위한 외부궤도형 초음파 다층치료기의 설계)

  • Kim Whi-Young
    • Journal of the Korea Computer Industry Society
    • /
    • v.7 no.3
    • /
    • pp.245-252
    • /
    • 2006
  • Estrangement hierarchical by bipolarization is deepened and time space that social welfare by graying corresponds great so. Specially, is real condition that indifference by patient's increase which is solitary life string is come to involve by social Voblem. Together, Jaetaek bone fracture patient's ratio is zooming. <중략>Supersonic waves operation frequency used on both end because do 1mHz, 1.3mHz, supersonic waves origination that have 1.5mHz's Piezo-ceramic crystal tranducer material each 4 premature senilitys in this research, and outside diameter according to impedance and Phase d used Gakgak4mm, 5.4mm, Dukke0.5mm, transformer deuce of length 70mm. Manufactured, and investigated supersonic waves distribution chart by capacity 50m W. Supersonic waves used by diagnosis mainly but is seen to become convenient medical treatment mounting in bone fracture patient's treatment if supplement clinically. If supplement system furthermore, is going to apply to osteoporosis patient, and this research tried to design poetic theme width directly and study rain standardization special qualify and approach basic form because do modelling.

  • PDF