• Title/Summary/Keyword: 치료 선량 확인

Search Result 508, Processing Time 0.027 seconds

Radiotherapy of Supratentorial Primitive Neuroectodermal Tumor (천막상부 원시신경외배엽 종양의 방사선요법)

  • Kim Il Han;Yoo Hyung Jun;Cho Young Kan;Kim Dae Yong
    • Radiation Oncology Journal
    • /
    • v.15 no.1
    • /
    • pp.11-18
    • /
    • 1997
  • Purpose : To evaluate the efficacy of combined treatment of surgery and chemoradiotherapy for supratentorial primitive neuroectodermal tumors (SPNET) and obtain the Prognostic factors and complications Materials and Methods .The a9e of 18 patients ranged from 1 to 27 years (median=5 years). There were 12 males and 6 females The extents of surgery were gross total (n:9), subtotal (n:8), biopsy only (n: 1). Craniospinal radiotherapy was delivered to all the patients except 2 patients who were treated only with the whole brain and primary lesion. Radiation dose were 3120-5800cGy (median=5460) to primary mass, 1500-4200cGy (median=3600cGy) to the whole brain and 1320-3600cGy (median= 2400 cGy) to the spinal axis. Chemotherapy was done in 13 patients. Median follow-up period was 45 months ranged from 1 to 89 months. Results : Patterns of failure were as follows; local recurrence (1), multiple intracranial recurrence (2), spinal seeding (3), craniospinal seeding (2) and multiple bone metastasis (1). Two of two patients who did not received craniospinal radiotherapy failed at spinal area. All the relapsed cases died at 1 to 13 months after diagnosis of progression. The 2- and 5-rear overall survival rates were $61\%\;and\;49\%$, respectively The a9e, sex, tumor location did not influence the survival but aggressive resection with combined chemotherapy showed better outcome. Among 9 survivors, complications were detected as radiation necrosis (n=1), hypopituitarism (n=2), cognitive defect(n=1), memory deficit (n=1), growth retardation (n=1). Conclusion : To improve the results of treatment of SPNET, maximal surgical resection followed by radiation therapy and chemotherapy is necessary. The extended radiation field including craniospinal axis may reduce the recurrence in spinal axis.

  • PDF

Development of Respiration Gating RT Technique using Moving Phantom and Ultrasound Sensor: a feasibility study (동 팬텀과 초음파 센서를 이용한 호흡운동 조절 방사선치료 기술 개발)

  • Lee Suk;Lee Sang Hoon;Shin Dongho;Yang Dae Sik;Choi Myung Sun;Kim Chul Yong
    • Radiation Oncology Journal
    • /
    • v.22 no.4
    • /
    • pp.316-324
    • /
    • 2004
  • Purpose : In radiotherapy of tumors in liver, enough planning target volume (PTV) margins are necessary to compensate breathing-related movement of tumor volumes. To overcome the problems, this study aims to obtain patients' body movements by using a moving phantom and an ultrasonic sensor, and to develop respiration sating techniques that can adjust patients' beds by using reversed values of the data obtained. Materials and Methods : The phantom made to measure patients' body movements is composed of a microprocessor (BS II, 20 MHz, 8K Byte), a sensor (Ultra-Sonic, range $3\~3$ m), host computer (RS232C) and stepping motor (torque 2.3 Kg) etc., and the program to control and operate it was developed. The program allows the phantom to move within the maximum range of 2 cm, its movements and corrections to take place In order, and x, y and z to move successively. After the moving phantom was adjusted by entering random movement data (three dimensional data form with distance of 2 cm), and the phantom movements were acquired using the ultra sonic sensor, the two data were compared and analyzed. And then, after the movements by respiration were acquired by using guinea pigs, the real-time respiration gating techniques were drawn by operating the phantom with the reversed values of the data. Results : The result of analyzing the acquisition-correction delay time the three types of data values and about each value separately shows that the data values coincided with one another within $1\%$ and that the acquisition-correction delay time was obtained real-time $(2.34{\times}10^{-4}sec)$. Conclusion : This study successfully confirms the clinic application possibility of respiration gating techniques by using a moving phantom and an ultrasonic sensor. With ongoing development of additional analysis system, which can be used in real-time set-up reproducibility analysis, it may be beneficially used in radiotherapy of moving tumors.

Evaluation of the Usefulness of the Transmittance of Metal Filaments Fabricated by 3D Printers in Radiation Therapy (방사선 치료에서 3D 프린터로 제작된 금속 필라멘트의 투과율에 관한 유용성 평가)

  • Kwon, Kyung-Tae;Jang, Hui-Min;Yoon, Myeong-Seong
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.7
    • /
    • pp.965-973
    • /
    • 2021
  • Since radiation therapy is irradiated with high-energy X-rays in a variety of at least 20 Gy to 80 Gy, a high dose is administered to the local area where the tumor is located, and various side effects of some normal tissues are expected. Currently, in clinical practice, lead, a representative material, is used as an effort to shield normal tissues, but lead is classified as a heavy metal harmful to the human body, and a large amount of skin contact can cause poisoning. Therefore, this study intends to manufacture a measurement sheet that can compensate for the limitations of lead using the materials Tungsten, Brass, and Copper of the 3D printer of the FDM (Fused Deposition Modeling) method and to investigate the penetration performance. Tungsten mixed filament transmission measurement sheet size was 70 × 70 mm and thickness 1, 2, 4 mm using a 3D printer, and a linear accelerator (TrueBeam STx, S/N: 1187) was measured by irradiating 100 MU at SSD 100 cm and 5 cm in water using a water phantom, an ion chamber (FC-65G), and an elcetrometer (PTW UNIDOSE), and the permeability was evaluated. As a result of increasing the measurement sheet of each material by 1 mm, in the case of Tungsten sheet at 3.8 to 3.9 cm in 6 MV, the thickness of the lead shielding body was thinner than 6.5 cm, and in case of Tungsten sheet at 4.5 to 4.6 cm in 15 MV. The sheet was thinner than the existing lead shielding body thickness of 7 cm, and equivalent performance was confirmed. Through this study, the transmittance measurement sheet produced using Tungsten alloy filaments confirmed the possibility of transmission shielding in the high energy region. It has been confirmed that the usability as a substitute is also excellent. It is thought that it can be provided as basic data for the production of shielding agents with 3D printing technology in the future.

Radiation-Induced Proctitis in Rat and Role of Nitric Oxide (백서모델에서 방사선 직장염 유발인자로서의 Nitric oxide의 역할)

  • Chun Mison;Kang Seunghee;Jin Yoon-Mi;Oh Young-Taek;Kil Hoon-Jong;Oh Tae-Young;Ahn Byoung-Ok
    • Radiation Oncology Journal
    • /
    • v.19 no.3
    • /
    • pp.265-274
    • /
    • 2001
  • Purpose : Proctitis is one of acute complications encountered when radiotherapy was appled to the pelvis. Radiation-induced proctitis represents similar microscopic findings that are observed in inflammatory bowel disease (IBD). Nitric oxide (NO) plays an important role in the inflammatory process and many data suggest a close relationship between NO production and gastrointestinal inflammation. This study was aimed to establish the optimal radiation dose for radiation-induced proctitis in rat and to find a relationship between radiation proctitis and NO production. Materials and methods : Female Wistar rats, weighing from 150 to 220 g, received various doses(10-30 Gy) of radiation to the rectum. On the 5th and 10th day after irradiation, rectal specimens were evaluated grossly and microscopically. In addition, the degree of NO production by irradiation dose was evaluated by study with NOS expression and nitrite production in the irradiated rectal tissue. To evaluate relationship between radiation proctitis and NO, we administered aminoguanidine, iNOS inhibitor and L-arginine, substrate of NOS to rats from 2 days before to 7 days after the irradiation. Results : There were obvious gross and hostological changes after 17.5 Gy or higher radiation dose but not with 15 Gy or less radiation dose. Twenty Gy or higher dose of radiation caused Grade 4 damage in most of rectal specimens which were more likely to be related to the late complications such as fibrosis, rectal bleeding and rectal obstruction. A single fraction of 17.5 Gy to the rat rectum is considered to be an optimal dose to produce commonly experienced proctitis in the clinic. The result demonstrated that severity of microscopic damage of rectal mucosa from irradiation significantly correlated with iNOS over-expression. However, administration of iNOS inhibitor or substrate of iNOS did not influence the degree of rectal damage. Conclusion : A single fraction of 17.5 Gy irradiation to the rat rectum considered to be an optimal dose for radiation induced proctitis model. These results indicated that an excess production of NO contributes to pathogenesis of radiation-induced proctitis in part but was not the direct cause of rectal damage.

  • PDF

Dynamic Computed Tomography based on Spatio-temporal Analysis in Acute Stroke: Preliminary Study (급성 뇌졸중 환자의 시공간 분석 기법을 이용한 동적 전산화 단층 검사: 예비 연구)

  • Park, Ha-Young;Pyeon, Do-Yeong;Kim, Da-Hye;Jung, Young-jin
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.543-547
    • /
    • 2016
  • Acute stroke is a one of common disease that require fast diagnosis and treatment to save patients life. however, the acute stroke may cause lifelong disability due to brain damage with no prompt surgical procedure. In order to diagnose the Stroke, brain perfusion CT examination and possible rapid implementation of 3D angiography has been widely used. However, a low-dose technique should be applied for the examination since a lot of radiation exposure to the patient may cause secondary damage for the patients. Therefore, the degradation of the measured CT images may interferes with a clinical check in that blood vessel shapes on the CT image are significantly affected by gaussian noise. In this study, we employed the spatio-temporal technique to analyze dynamic (brain perfusion) CT data to improve an image quality for successful clinical diagnosis. As a results, proposed technique could remove gaussian noise successfully, demonstrated a possibility of new image segmentation technique for CT angiography. Qualitative evaluation was conducted by skilled radiological technologists, indicated significant quality improvement of dynamic CT images. the proposed technique will be useful tools as a clinical application for brain perfusion CT examination.

Treatment Outcome of Locally Advanced Non-small Cell Lung Cancer Patients Who Received Concurrent Chemoradiotherapy with Weekly Paclitaxel (Paclitaxel 매주 투여 및 방사선치료 동시요법을 받은 국소진행성 비소세포폐암 환자들의 치료 결과)

  • Kim, Su-Zy;Shim, Byoung-Yong;Kim, Chi-Hong;Song, So-Hyang;Ahn, Meyung-Im;Cho, Deog-Gon;Cho, Kyu-Do;Yoo, Jin-Young;Kim, Hoon-Kyo;Kim, Sung-Whan
    • Radiation Oncology Journal
    • /
    • v.24 no.4
    • /
    • pp.230-236
    • /
    • 2006
  • $\underline{Purpose}$: To analyze the response, toxicity, patterns of failure and survival rate of patients with locally advanced non-small cell lung cancer who were treated with concurrent chemoradiotherapy with weekly paclitaxel. $\underline{Materials\;and\;Methods}$: Twenty-three patients with locally advanced non-small cell lung cancer patients who received radical chemoradiotherapy from October 1999 to September 2004 were included in this retrospective study. Patients received total $55.4{\sim}64.8$ (median 64.8) Gy (daily 1.8 Gy per fraction, 5 days per weeks) over $7{\sim}8$ weeks. 50 or $60\;mg/m^2$ of paclitaxel was administered on day 1, 8, 15, 22, 29 and 36 of radiotherapy. Four weeks after the concurrent chemoradiotherapy, three cycles of consolidation chemotherapy consisted of paclitaxel $135\;mg/m^2$ and cisplatin $75\;mg/m^2$ was administered every 3 weeks. $\underline{Results}$: Of the 23 patients, 3 patients refused to receive the treatment during the concurrent chemoradiotherapy. One patient died of bacterial pneumonia during the concurrent chemoradiotherapy. Grade 2 radiation esophagitis was observed in 4 patients (17%). Sixteen patients received consolidation chemotherapy. During the consolidation chemotherapy, 8 patients (50%) experienced grade 3 or 4 neutropenia and one of those patients died of neutropenic sepsis. Overall response rate for 20 evaluable patients was 90% including 4 complete responses (20%) and 14 partial responses (70%). Among 18 responders, 9 had local failure, 3 had local and distant failure and 2 had distant failure only. Median progression-free survival time was 9.5 months and 2-year progression-free survival rate was 19%. Eleven patients received second-line or third-line chemotherapy after the treatment failure. The median overall survival time was 21 months. 2-year and 5-year survival rate were 43% and 33%, respectively. Age, performance status, tumor size were significant prognostic factors for progression-free survival. $\underline{Conclusion}$: Concurrent chemoradiotherapy with weekly paclitaxel revealed high response rate and low toxicity rate. But local failure occurred frequently after the remission and large tumor size was a poor prognostic factor. Further investigations are needed to improve the local control.

Development of $^{166}Ho$-Stent for the Treatment of Esophageal Cancer (식도암 치료용 $^{166}Ho$-Stent 개발)

  • Park, Kyung-Bae;Kim, Young-Mi;Kim, Kyung-Hwa;Shin, Byung-Chul;Park, Woong-Woo;Han, Kwang-Hee;Chung, Young-Ju;Choi, Sang-Mu;Lee, Jong-Doo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.1
    • /
    • pp.62-73
    • /
    • 2000
  • Purpose: Esophageal cancer patients have a difficulty in the intake of meals through the blocked esophageal lumen, which is caused by an ingrowth of cancer cells and largely influences on the prognosis. It is reported that esophageal cancer has a very low survival rate due to the lack of nourishment and immunity as the result of this. In this study a new radioactive stent, which prevents tumor ingrowth and restenosis by additional radiation treatment, has been developed. Materials and Methods: Using ${\ulcorner}HANARO{\lrcorner}$ research reactor, the radioactive stent assembly ($^{166}Ho$-SA) was prepared by covering the metallic stent with a radioactive sleeve by means of a post-irradiation and pre-irradiation methods. Results: Scanning electron microscopy and autoradiography exhibited that the distribution of $^{165/166}Ho\;(NO_3)$ compounds in polyurethane matrix was homogeneous. A geometrical model of the esophagus considering its structural properties, was developed for the computer simulation of energy deposition to the esophageal wall. The dose distributions of $^{166}Ho$-stent were calculated by means of the EGS4 code system. The sources are considered to be distributed uniformly on the surface in the form of a cylinder with a diameter of 20 mm and length of 40 mm. As an animal experiment, when radioactive stent developed in this study was inserted into the esophagus of a Mongrel dog, tissue destruction and widening of the esophageal lumen were observed. Conclusion: We have developed a new radioactive stent comprising of a radioactive tubular sleeve covering the metallic stent, which emits homogeneous radiation. If it is inserted into the blocked or narrowed lumen, it can lead to local destruction of the tumor due to irradiation effect with dilatation resulting from self-expansion of the metallic property. Accordingly, it is expected that restenosis esophageal lumen by the continuous ingrowth and infiltration of cancer after insertion of our radioactive stent will be decreased remarkably.

  • PDF

Evaluation of Combine IGRT using ExacTrac and CBCT In SBRT (정위적체부방사선치료시 ExacTrac과 CBCT를 이용한 Combine IGRT의 유용성 평가)

  • Ahn, Min Woo;Kang, Hyo Seok;Choi, Byoung Joon;Park, Sang Jun;Jung, Da Ee;Lee, Geon Ho;Lee, Doo Sang;Jeon, Myeong Soo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.201-208
    • /
    • 2018
  • Purpose : The purpose of this study is to compare and analyze the set-up errors using the Combine IGRT with ExacTrac and CBCT phased in the treatment of Stereotatic Body Radiotherapy. Methods and materials : Patient who were treated Stereotatic Body Radiotherapy in the ulsan university hospital from May 2014 to november 2017 were classified as treatment area three brain, nine spine, three pelvis. First using ExacTrac Set-up error calibrated direction of Lateral(Lat), Longitudinal(Lng), Vertical(Vrt), Roll, Pitch, Yaw, after applied ExacTrac moving data in addition to use CBCT and set-up error calibrated direction of Lat, Lng, Vrt, Rotation(Rtn). Results : When using ExacTrac, the error in the brain region is Lat $0.18{\pm}0.25cm$, Lng $0.23{\pm}0.04cm$, Vrt $0.30{\pm}0.36cm$, Roll $0.36{\pm}0.21^{\circ}$, Pitch $1.72{\pm}0.62^{\circ}$, Yaw $1.80{\pm}1.21^{\circ}$, spine Lat $0.21{\pm}0.24cm$, Lng $0.27{\pm}0.36cm$, Vrt $0.26{\pm}0.42cm$, Roll $1.01{\pm}1.17^{\circ}$, Pitch $0.66{\pm}0.45^{\circ}$, Yaw $0.71{\pm}0.58^{\circ}$, pelvis Lat $0.20{\pm}0.16cm$, Lng $0.24{\pm}0.29cm$, Vrt $0.28{\pm}0.29cm$, Roll $0.83{\pm}0.21^{\circ}$, Pitch $0.57{\pm}0.45^{\circ}$, Yaw $0.52{\pm}0.27^{\circ}$ When CBCT is performed after the couch movement, the error in brain region is Lat $0.06{\pm}0.05cm$, Lng $0.07{\pm}0.06cm$, Vrt $0.00{\pm}0.00cm$, Rtn $0.0{\pm}0.0^{\circ}$, spine Lat $0.06{\pm}0.04cm$, Lng $0.16{\pm}0.30cm$, Vrt $0.08{\pm}0.08cm$, Rtn $0.00{\pm}0.00^{\circ}$, pelvis Lat $0.06{\pm}0.07cm$, Lng $0.04{\pm}0.05cm$, Vrt $0.06{\pm}0.04cm$, Rtn $0.0{\pm}0.0^{\circ}$. Conclusion : Combine IGRT with ExacTrac in addition to CBCT during Stereotatic Body Radiotherapy showed that it was possible to reduce the set-up error of patients compared to single ExacTrac. However, the application of Combine IGRT increases patient set-up verification time and absorption dose in the body for image acquisition. Therefore, depending on the patient's situation that using Combine IGRT to reduce the patient's set-up error can increase the radiation treatment effectiveness.

  • PDF

Measurement of Specific Radioactivity for Clearance of Waste Contaminated with Re-186 for Medical Application (의료용 Re-186 오염폐기물의 규제해제를 위한 방사능측정)

  • Kim, Chang-Bum;Lee, Sang-Kyung;Jang, Seong-Joo;Kim, Jung-Min
    • Journal of radiological science and technology
    • /
    • v.40 no.4
    • /
    • pp.633-638
    • /
    • 2017
  • The amount of radioactive waste has been rapidly increased with development of radiation treatment in medical field. Recently, it has been a common practice to use I-131 for thyroid cancer, F-18 for PET/CT and Tc-99m for diagnosis of nuclear medicine. All the wastes concerned have been disposed of by means of the self-disposal method, for example incineration, after storage enough to decay less than clearance level. IAEA proposed criteria for clearance level of waste which depends on the individual ($10{\mu}Sv/y$) and collective dose (1 man-Sv/y), and concentration of each nuclide (IAEA Safety Series No 111-P-1.1, 1992 and IAEA RS-G-1.7, 2004). In this study, specific radioactivity of radioactive waste contaminated with Re-186 was measured to confirm whether it meets the clearance level. Re-186 has long half life of 3.8 days relatively and emits beta and gamma radiation, therefore it can be applied in treatment and imaging purposes. The specific radioactivity of contaminated gloves weared by radiation workers was measured by MCA(Multi-channel Analyzer) which was calibrated by reference materials in accordance with the measuring procedure. As a result, comparison evaluation of decay storage period between the half-life which was calculated by attenuation curve based on real measurement and physical half-life was considered, and it is showed that the physical half-life is longer than induced half-life. Therefore, the storage period of radioactive waste for self-disposal may be curtailed in case of application of induced half-life. The result of this study will be proposed as ISO standard.

Study on accuracy of panorama and CBCT through length measurement of wisdom teeth (사랑니 길이 측정을 통한 파노라마와 CBCT의 정확도 연구)

  • Jeong, Cheonsoo;Kim, Chongyeal
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.2
    • /
    • pp.131-136
    • /
    • 2013
  • Panorama of dental radiation generators can observe the wide anatomical structures of oral and maxillofacial areas but there can be distortion of lengths, angles, or shapes. CBCT can diagnose 3D images and get the ones whose errors by superposition and interference are remarkably smaller between anatomical structures. But the quality of the images by movement of subjects can be lowered as it takes long to diagnose them. And if there are impermeable radiation objects like metal in mouths, impermeable radiation lines can radially appear with the objects as center. This study tries to analyze accuracy of panorama and CBCT and get useful anatomical information in dental treatment by comparing the length of wisdom teeth which were measured by Panorama and CBCT with the teeth which were actually extracted and analyzing distortion of the teeth. The test result could be found that Panorama is expanded by average 7.3% as the errors of Panorama and Digital Vernier Caliper range from 110.7% to 103.9%. The length of wisdom teeth which were measured in CBCT and Digital Vernier Caliper could be found that the error range is 1.3%. And the length of wisdom teeth which were measured in Panorama and Digital Vernier Caliper has found that the error range shows 7.3%. So it could be found that the images of CBCT is about 6% more exact than those of Panorama. It could be found that CBCT shows the more exact images than those of Panorama. But because the examination expenses of CBCT are higher than those of Panorama and exposure dose of CBCT is much more than that of Panorama, it is thought to find proper ways in examination.