• Title/Summary/Keyword: 치료방사선

Search Result 4,809, Processing Time 0.029 seconds

Palliative Radiotherapy (증상완화목적의 방사선치료)

  • Lee, Chang-Geol
    • Journal of Hospice and Palliative Care
    • /
    • v.12 no.1
    • /
    • pp.1-4
    • /
    • 2009
  • The aim of palliative radiotherapy (RT) is to control cancer-related local symptoms with minimal radiation reaction. About one third of all radiation treatments are given with palliative intent. Indications for RT in symptom palliation are as follows: Pain from bone metastasis, pressure symptom from brain and spinal cord, obstruction of bronchus, esophagus, superior vena cava and malignant cancer bleeding from bronchus, urinary tract, uterine cervix and rectum. In hospice palliative care, RT is very effective for symptom palliation and improvement of quality of life without influence on survival.

  • PDF

Bedside Teaching of Relaxation Technique for Terminal Cancer Patients Treated with Radiation Therapy (방사선치료를 받는 말기암환자들을 대상으로 한 이완요법)

  • Kim, Sang-Won;Chun, Mison;Kim, Hyo Shin
    • Journal of Hospice and Palliative Care
    • /
    • v.19 no.3
    • /
    • pp.256-261
    • /
    • 2016
  • Radiation therapy is an effective modality to alleviate cancer-related symptoms. To deliver radiation accurately, it is essential to secure stability of the treatment position in patients during each treatment time. However, some patients could be less cooperative due to their psychoemotional issues. We present two cases of terminal-stage cancer patients who were initially unable to lie still on the treatment table before simulation. A relaxation technique was taught to them on the bed, and they could relax and undergo radiation therapy with effective symptom relief.

A Study on the Skin Dose Measurement of Glass Dosimeter Use During Rectal Cancer 3field Technic and Cervical Cancer 4field Technic Radiation Therapy (직장암 3문조사와 자궁경부암 4문조사 방사선 치료 시 유리선량계를 이용한 피부선량 측정에 관한 연구)

  • Shin, Seong-Soo;Choi, Won-Sik;Park, Cheol-Soo;Lee, Sun-Yeb;Cho, Jae-Hwan;Seo, Jeong-Min;Shim, Jae-Koo;Kim, Chan-Hyeong;Goo, Eun-Hoe;Kim, Eng-Chan
    • Journal of radiological science and technology
    • /
    • v.34 no.2
    • /
    • pp.157-163
    • /
    • 2011
  • Recently a variety of high technologies for radiation therapy (IMRT, SRS,. 3D-RT, etc.) has been developed. For the cervical and rectal cancer, 3field or 4field radiotherapy have been applied to the patients. In the case of two-dimensional treatment, one of the most typical side-effects is skin burn due to the radiation irradiation. In general the skin dose is evaluated by only a single measurement during the whole treatment period. In this study, however, skin dose was measured in each radiation treatment and the total skin dose was accumulated in a glass dosimeter through all the cases. After simulating the skin dose from treatment planning system, the results were compared with the actual skin doses. The results showed a good agreement between two data sets. Even though there are certain amount of errors caused by the patient movement along the treatment, the difference between actual dose and simulated dose was within the accepted range of error.

Advances in Radiation Oncology in New Millennium in Korea (21세기 방사선종양학의 전망:최근의 진보와 한국에서의 발전)

  • Huh, Seung-Jae;Park, Chan-Il
    • Radiation Oncology Journal
    • /
    • v.18 no.3
    • /
    • pp.167-176
    • /
    • 2000
  • The objective of recent radiation therapy is to improve the quality of treatment and the after treatment quality of life. In Korea, sharing the same objective, significant advancement was made due to the gradual increase of patient number and rapid increase of treatment facilities. The advancement includes generalization of three-dimensional conformal radiotherapy (3D-CRT), application of linac-based stereotactic radiosurgery (SRS), and furthermore, the introduction of intensity modulated radiation therapy (IMRT). Authors in this paper prospectively review the followings: the advancement of radiation oncology in Korea, the recent status of four-dimensional radiation therapy, IMRT, the concept of the treatment with biological conformity, the trend of combined chemoradiotherapy, the importance of internet and radiation oncology information management system as influenced by the revolution of information technology, and finally the global trend of telemedicine in radiation oncology. Additionally, we suggest the methods to improve radiotherapy treatment, which include improvement of quality assurance (QA) measures by developing Koreanized QA protocol and system, regional study about clinical protocol development for phase three clinical trial, suggestion of unified treatment protocol and guideline by academic or research societies, domestic generation of treatment equipment's or system, establishment of nationwide data base of radiation-oncology-related information, and finally patterns-of-care study about major cancers.

  • PDF

A Study on Treatment Target Position Verification by using Electronic Portal Imaging Device & Fractionated Stereotatic Radiotherapy (EPID와 FSRT를 이용한 치료표적위치 검증에 관한 연구)

  • Lee, Dong-Hoon;Kwon, Jang-Woo;Park, Seung-Woo;Kim, Yoon-Jong;Lee, Dong-Han;Ji, Young-Hoon
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.46 no.3
    • /
    • pp.44-51
    • /
    • 2009
  • It is very important to verify generated setup errors in cancer therapy by using a high energy radiation and to perform the precise radiation therapy. Specially, the verification of treatment position is very crucial in special therapies like fractionated stereotatic radiotherapy (FSRT). The FSRT uses normally high-dose, small field size for treating small intracranial lesions. To estimate the developed FSRT system, the isocenter accuracy of gantry, couch and collimator were performed and a total of inaccuracy was less than ${\pm}1mm$. Precise beam targeting is crucial when using high-dose, small field size FSRT for treating small intracranial lesions. The EPID image of the 3mm lead ball mounted on the isocenter with a 25mm collimator cone was acquired and detected to the extent of one pixel (0.76mm) after comparing the difference between the center of a 25mm collimator cone and a 3 mm ball after processing the EPID image. In this paper, the radiation treatment efficiency can be improved by performing precise radiation therapy with a developed video based EPID and FSRT at near real time

The Measurements of Plasma Cytokines in Radiation-induced Pneumonitis in Lung Cancer Patients (폐암환자에서 방사선 폐렴 예측을 위한 혈장 Cytokine측정)

  • Hur Won Joo;Youn Seon Min;Lee Hyung Sik;Yang Kwang Mo;Sin Geun Ho;Son Choon Hee;Han Jin Yeong;Lee Ki Nam;Jeong Min Ho
    • Radiation Oncology Journal
    • /
    • v.18 no.4
    • /
    • pp.314-320
    • /
    • 2000
  • Purpose :To investigate whether changes in plasma concentrations of transforming growth factor-$\beta$1(TGF-$\beta$1), tumor necrosis factor-alpha (TNF-$\alpha$) and interleukin-6 (IL-6) could be used to identify the development of radiation-induced pneumonitis in the lung cancer patients. Methods and Materials :Seventeen patients with lung cancer (11 NSCLC, 6 SCLC) were enrolled in a prospective study designed to evaluate clinical and molecular biologic correlation of radiation-induced pneumonitis. The study began in May 1998 and completed in July 1999. All patients were treated with radiotherapy with curative intent : 1.8 Gy per day, 5 fractions per week. Serial measurements of plasma TGF-$\beta$1, TNF-$\alpha$ and IL-6 were obtained in all patients before, weekly during radiotherapy and at each follow-up visits after completion of treatment. These measurements were quantified using enzyme linked immunosorbent assay (ELISA). All patients were evaluated for signs and symptoms of pneumonitis at each follow-up visit after completion of radiotherapy. High resolution CT (HRCT) scans were obtained when signs and symptoms of pneumonitis were developed after completion of radiotherapy. Results : Thirteen patients eventually developed signs and symptoms of clinical pneumonitis 씬file four patients did not. TGF-$\beta$ 1 levels were elevated in all 13 patients with pneumonitis, which showed characteristic pattern of elevation (38.45 ng/ml at pretreatment, 13.66 ng/ml during radiotherapy, then 60.63 ng/ml at 2-4 weeks after completion of radiotherapy). The levels of TNF- $\alpha$ and IL-6 were also elevated In the group of patients who developed pneumonitis but the pattern was not characteristic. Conclusions : Changes in plasma TGF$\beta$-1 levels before, during and after radiotherapy appears to be a useful means by which to identify patients at risk for the development of symptomatic pneumonitis. Other cytokines like TNF- $\alpha$ and IL-6 shows no meaningful changes in association with radiation pneumonitis.

  • PDF

Evaluation of the Jaw-Tracking Technique for Volume-Modulated Radiation Therapy in Brain Cancer and Head and Neck Cancer (뇌암 및 두경부암 체적변조방사선치료시 Jaw-Tracking 기법의 선량학적 유용성 평가)

  • Kim, Hee Sung;Moon, Jae Hee;Kim, Koon Joo;Seo, Jung Min;Lee, Joung Jin;Choi, Jae Hoon;Kim, Sung Ki;Jang, In-Gi
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.177-183
    • /
    • 2018
  • Purpose : Volumetric Modulated Arc Therapy(VMAT) has the advantage of uniformly and precisely irradiating the tumor to the shape of the tumor while reducing the risk of radiation damage to normal tissues. such as brain cancer, head and neck cancer and prostate cancer, It is being used for treatment. The purpose of this study is to evaluate the usefulness of the Jaw-Tracking technique(JTT) in VMAT for brain and head and neck cancer. Materials and Methods : We selected eight patients with brain and head and neck cancer(4 Brain, 4 head and neck) who were treated with the VMAT treatment technique. Contouring information of the patient's tumor and normal organ was fused to the Rando phantom using the deformable registration of Velocity(Varian, USA). A treatment plan was developed using the Varian Eclipse(ver 15.5, Varian, USA) with the same patient actual beam parameters except for the use of jaw-tracking. As the evaluation index, the maximum dose and mean dose of target and OAR were compared and a portal dosimetry was performed for the treatment plan verification. Results : When using JTT, the relative dose of OAR decreased by 5.24 % and the maximum dose by 7.05 %, respectively, compared with the Static-Jaw technique(SJT). In the various OARs, the mean dose and maximum dose reduction ranges ranged from 0.01 to 3.16 Gy and from 0.12 to 6.27 Gy, respectively. In the case of the target, the maximum dose of GTV, CTV, PTV decreased by 0.17 %, 0.43 %, and 0.37 % in JTT, and the mean dose decreased by 0.24 %, 0.47 % and 0.47 %, respectively. Gamma analysis The JTT and SJT passing rates were $98{\pm}1.73%$ and $97{\pm}1.83%$ on the basis of 3 % / 3 mm, respectively. Comparing the doses of all OARs applied to the experiment, it was found that the use of JTT resulted in a significant decrease in dose due to additional jaw shielding besides MLC than SJT. Conclusion : In radiation therapy using VMAT treatment plan, we can apply JTT in the case of adjacent tumor and normal organs such as brain cancer and head and neck cancer, and in radiotherapy required large field and high energy caused increase leakage dose through MLC. It is considered that the target dose of PTV can be increased by lowering the dose of normal tissue surrounding the tumor.

  • PDF

A Patterns of Care Study of the Various Radiation Therapies for Prostate Cancer among Korean Radiation Oncologists in 2006 (Patterns of Care Study를 위한 2006년 한국 방사선종양학과 전문의들의 전립선암 방사선치료원칙 조사연구)

  • Kim, Jin-Hee;Kim, Jae-Sung;Ha, Sung-Whan;Shin, Seong-Soo;Park, Won;Cho, Jae-Ho;Suh, Chang-Ok;Oh, Young-Taek;Shin, Sei-Won;Kim, Jae-Chul;Jang, Ji-Young;Nam, Taek-Keun;Choi, Young-Min;Kim, Il-Han
    • Radiation Oncology Journal
    • /
    • v.26 no.2
    • /
    • pp.96-103
    • /
    • 2008
  • Purpose: To conduct a nationwide academic hospital patterns of the practice status and principles of radiotherapy for prostate cancer. The survey will help develop the framework of a database of Korean in Patterns of Case Study. Materials and Methods: A questionnaire about radiation treatment status and principles was sent to radiation oncologists in charge of prostate cancer treatment at thirteen academic hospitals in Korea. The data was analyzed to find treatment principles among the radiation oncologists when treating prostate cancer. Results: The number of patients with prostate cancer and treated with radiation ranged from 60 to 150 per academic hospital in Seoul City and 10 to 15 outside of Seoul City in 2006. The primary diagnostic methods of prostate cancer included the ultrasound guided biopsy on 6 to 12 prostate sites(mean=9), followed by magnetic resonance imaging and a whole body bone scan. Internal and external immobilizations were used in 61.5% and 76.9%, respectively, with diverse radiation targets. Whole pelvis radiation therapy(dose ranging from 45.0 to 50.4 Gy) was performed in 76.9%, followed by the irradiation of seminal vesicles($54.0{\sim}73.8$ Gy) in 92.3%. The definitive radiotherapy doses were increased as a function of risk group, but the range of radiation doses was wide(60.0 to 78.5 Gy). Intensity modulated radiation therapy using doses greater than 70 Gy, were performed in 53.8% of academic hospitals. In addition, the simultaneous intra-factional boost(SIB) technique was used in three hospitals; however, the target volume and radiation dose were diverse. Radiation therapy to biochemical recurrence after a radical prostatectomy was performed in 84.6%; however, the radiation dose was variable and the radiation field ranged from whole pelvis to prostate bed. Conclusion: The results of this study suggest that a nationwide Korean Patterns of Care Study is necessary for the recommendation of radiation therapy guidelines of prostate cancer.

Study on the Photoneutrons Produced in 15 MV Medical Linear Accelerators : Comparison of Three-Dimensional Conformal Radiotherapy and Intensity-Modulated Radiotherapy (15 MV 의료용 선형가속기에서 발생되는 광중성자의 선량 평가 - 3차원입체조형방사선치료와 세기조절방사선치료의 비교 -)

  • Yang, Oh-Nam;Lim, Cheong-Hwan
    • Journal of radiological science and technology
    • /
    • v.35 no.4
    • /
    • pp.335-343
    • /
    • 2012
  • Intensity-modulated radiotherapy(IMRT) have the ability to provide better dose conformity and sparing of critical normal tissues than three-dimensional radiotherapy(3DCRT). Especially, with the benefit of health insurance in 2011, its use now increasingly in many modern radiotherapy departments. Also the use of linear accelerator with high-energy photon beams over 10 MV is increasing. As is well known, these linacs have the capacity to produce photonueutrons due to photonuclear reactions in materials with a large atomic number such as the target, flattening filters, collimators, and multi-leaf collimators(MLC). MLC-based IMRT treatments increase the monitor units and the probability of production of photoneutrons from photon-induced nuclear reactions. The purpose of this study is to quantitatively evaluate the dose of photoneutrons produced from 3DCRT and IMRT technique for Rando phantom in cervical cancer. We performed the treatment plans with 3DCRT and IMRT technique using Rando phantom for treatment of cervical cancer. An Rando phantom placed on the couch in the supine position was irradiated using 15 MV photon beams. Optically stimulated luminescence dosimeters(OSLD) were attached to 4 different locations (abdomen, chest, head and neck, eyes) and from center of field size and measured 5 times each of locations. Measured neutron dose from IMRT technique increased by 9.0, 8.6, 8.8, and 14 times than 3DCRT technique for abdomen, chest, head and neck, and eyes, respectively. When using IMRT with 15 MV photonbeams, the photoneutrons contributed a significant portion on out-of-field. It is difficult to prevent high energy photon beams to produce the phtoneutrons due to physical properties, if necessary, It is difficult to prevent high energy photon beams to produce the phtoneutrons due to physical properties, if necessary, it is need to provide the additional safe shielding on a linear accelerator and should therefore reduce the out-of-field dose.

Randomized Trial of Early Versus Late Alternating Radiotherapy/ Chemotherapy in Limited-Disease Patients with Small Cell Lung Cancer (국한성병기 소세포폐암 환자에서 조기 혹은 지연 교대 방사선-항암제치료의 전향적 비교연구)

  • Lee Chang Geol;Kim Joo Hang;Kim Sung Kyu;Kim Sei Kyu;Kim Gwi Eon;Suh Chang Ok
    • Radiation Oncology Journal
    • /
    • v.20 no.2
    • /
    • pp.116-122
    • /
    • 2002
  • Purpose : A randomized prospective study was conducted to compare the efficacy of early or late alternating schedules of radiotherapy, and carboplatin and ifosfamide chemotherapy in patients with limited-disease small cell lung cancer. Materials and Methods: From August 1993 to August 1996, a total of 44 patients with newly diagnosed, limited-disease small cell lung cancer, PS $H0\~2$, wt $loss<10\%$ were enrolled in a randomized trial which compared early alternating radiotherapy (RT)/chemotherapy (CT) and late alternating RT/CT. The CT regimen included ifosfamide $1.5\;g/m^2$ IV, d1-5 and carboplatin AUC 5/d IV, d2 peformed at 4 week intervals for a total of 6 cycles. RT (54 Gy/30 fr) was started after the first cycle of CT (early arm, N=22) or after the third cycle of CT (late arm, N=22) with a split course of treatment. Results : The pretreatment characteristics between the two arms were well balanced. The response rates in the early $(86\%)$ and late $(85\%)$ arm were similar. The median survival durations and 2-year survival rates were 15 months and $22.7\%$ in the early arm, and 17 months and $14.9\%$ in the late arm (p=0.47 by the log-rank test). The two-year progression free survival rates were $19.1\%$ in the early arm and $19.6\%$ in the late arm (p=0.52 by the log-rank test). Acute grade 3 or 4 hematologic and nonhematologic toxicities were similar between the two arms. Eighteen patients $(82\%)$ completed 6 cycles of CT in the early arm and 17 $(77\%)$ in the late arm. Four patients received less than 45 Gy of RT in the early arm and two in the late arm. There was no significant difference in the failure patterns. The local failure rate was $43\%$ in the early arm and $45\%$ in the late arm. The first site of failure was the brain in $24\%$ of the early arm patients compared to $35\%$ in the late arm (p=0.51). Conclusion : There were no statistical differences in the overall survival rate and the pattern of failure between the early and late alternating RT/CT in patients with limited-disease small cell lung cancer.