• Title/Summary/Keyword: 치관길이

Search Result 50, Processing Time 0.021 seconds

Comparison of the retention of the full veneer casted gold crowns with varying convergence angle, crown length and dental cements (수렴각과 치관 길이를 달리한 금속 다이상에서 치과용 시멘트 합착 후 전부주조관의 유지력 비교)

  • Yun, Jung-Ho;Cho, Jin-Hyung;Kim, Jee-Hwan;Lee, Keun-Woo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.2
    • /
    • pp.99-106
    • /
    • 2013
  • Purpose: The aim of this research was to establish the effect and variation in differing convergence angle and length of abutment on the retention of full veneer casted gold crown. Materials and methods: Two different length,5 mm and 10 mm in height with convergence angles of 5, 10, 15 and 25 degrees crowns were fabricated. Cementation was done using cements; zinc phosphate cement (Fleck's zinc phosphate cement), resin-modified glass ionomer cement (Vitremer) and resin cement (Panavia 21). These were tested for tensile force at the point of separation by using Instron Universal Testing Machine. Statistical analysis was done by SAS 6.04 package. Results: In all cements the mean retention decreased with significant difference on increase of convergence angle (P<.05). Increase in every 5 degree-convergence angel the retention rate decreased with resin-modified glass ionomer cement of 15.9% and resin cement of 14.8%. With zinc phosphate cement, there was largest decreasing rate of mean retention of 25.5% between convergence angles from 5 degree to 10 degree. When the crown length increased from 5 mm to 10 mm, the retention increased with the significant difference in the same convergence angle and in all types of cement used (P<.05). Conclusion: The retention was strongly dependent on geometric factors of abutment. Much care is required in choosing cements for an optimal retention in abutments with different convergence angles and crown lengths.

AGE ESTIMATION USING PANORAMIC RADIOGRAPHS OF DEVELOPING PERMANENT TEETH (발육중인 영구치의 파노라마 방사선 사진 계측을 이용한 연령 추정)

  • Choi, Eun-Young;Choi, Nam-Ki;Kim, Seon-Mi;Yang, Kyu-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.34 no.2
    • /
    • pp.215-221
    • /
    • 2007
  • The aim of this study was to test whether metric measurements of crown length, root length and apex width during tooth development could be a better basis for correlation with age than the classical methods based on subjective estimations of various stages of tooth development. Panoramic radiographs of 120 children, aged 7 to 9 years, were collected from the department of the pediatric dentistry of Chonnam National University Hospital, Korea. The methods of Mornstad was used to estimate age. The structures measured were crown length root length and apex width in panoramic radiographic. The results were as follows : 1. In the boys, it showed higher correlation between lower 2nd molar crown length, lower 1st molar root length or lower 1st permolar apical width and age. In the girls, it showed higher correlation between lower 2nd premolar crown length, lower 2nd molar root length or lower 1st molar apical width and age. 2. With the aid of a multiple regression model, a linear relationship between some of these distances and age was shown. Boy(months) = 43.958 + lower 2nd molar crown length ${\times}$ 4.392 + lower 1st molar root length ${\times}$ 2.255 - lower 1st permolar apical width ${\times}$ 2.046, Girl(months) = 75.213 + lower 2nd premolar crown length ${\times}$ 3.910 lower 2nd molar root length ${\times}$ 2.280 - lower 1st molar apical width ${\times}$ 6.217 Age was estimated in boys and girls using the mathematic model ; the mean difference between chronological and estimated ages was $-2.1{\pm}6.8$ months for boys and $6.1{\pm}6.2$ months for girls. Therefore, it seems to be more accurate and easier than the earlier methods.

  • PDF

Influence of crown-to-implant ratio of short vs long implants on implant stability and marginal bone loss in the mandibular single molar implant (하악 구치 단일임플란트 수복에서 임플란트 길이에 따른 치관-임플란트 비율이 임플란트안정성 및 변연골소실에 주는 영향)

  • Baek, Yeon-Wha;Kim, Bongju;Kim, Myung-Joo;Kwon, Ho-Beom;Lim, Young-Jun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.34 no.4
    • /
    • pp.280-289
    • /
    • 2018
  • Purpose: The purpose of this randomized clinical trial is to determine whether implant length and the crown-to-implant (C/I) ratio influence implant stability and peri-implant marginal bone loss (MBL). Materials and Methods: 46 patients with single tooth missing in the posterior molar region of the mandible were included in this study. 19 implants (CMI IS-III $active^{(R)}$ long implant) of 5.0 mm diameter and 10 mm length were installed for the control group, while 27 implants (CMI IS-III $active^{(R)}$ short implant) of 5.5 mm diameter and 6.6, 7.3 or 8.5 mm length were placed for the experimental group. Each implant was inserted and immediately loaded using the digitally pre-fabricated surgical template and provisional restoration. The CAD-CAM monolithic zirconia crown was fabricated at 3 months after the surgery as a definitive restoration. The ISQ value and the MBL was measured at 48 weeks after the surgery. The correlation between the C/I ratio, MBL, and secondary implant stability was analyzed. Results: Successful results in terms of ISQ and MBL were achieved with both groups. There was no significant difference between the groups in terms of ISQ values and MBL at 48 weeks after the surgery (P > 0.05). No significant correlation was found between the C/I ratio and secondary stability as well as the C/I ratio and the MBL (P > 0.05). Conclusion: The influence of C/I ratio in both groups was not shown on the stability nor the marginal bone loss in implants supporting single crown of the mandible. Short implant could be a preferable alternative option in the reduced bone height mandible under the limited condition despite its higher C/I ratio.

Anatomic study of the incisive canal in relation to midpalatal placement of mini-implant (정중구개부의 미니 임플랜트 식립과 관련된 절치관의 해부학적 연구)

  • Kim, Sung-Jin;Lim, Sung-Hoon
    • The korean journal of orthodontics
    • /
    • v.39 no.3
    • /
    • pp.146-158
    • /
    • 2009
  • Objective: The purpose of this study was to reveal the position of the incisive foramen in relation to the incisive papilla and cusp tips. Methods: Plaster models and CT images of 25 adult orthodontic patients were used to measure the width of the incisive canal and positions of the anterior and posterior borders of the incisive foramen in relation to the incisive papilla. Results: The palatal surface distance from the interdental papilla between the maxillary central incisors to the posterior border of the incisive foramen along the palatal surface was 1.7 fold of the distance from the interdental papilla between the central incisors to the posterior border of the incisive papilla. The distance between the posterior border of the incisive papilla and posterior border of the incisive foramen along the palatal surface was 6.15 ${\pm}$ 1.75 mm. The anteroposterior position of the posterior border of the incisive foramen was slightly anterior to the lingual cusp tips of the maxillary 1st premolars. The width of the incisive foramen was 4.03 ${\pm}$ 0.64 mm, therefore it is recommended to position the mini-implant more than 3 mm laterally when placing a mini-implant lateral to the incisive foramen, from the center. Conclusions: These results can be used as a reference in presuming the position of the incisive foramen when placing mini-implant in the anterior palate area.

Three dimensional photoelastic study on the initial stress distributions of alveolar bone when retracted by lingual K-loop archwire (Lingual K-loop archwire를 이용한 발치공간 폐쇄시 초기응력 분포에 대한 3차원 광탄성학적 연구)

  • Byun, Bo-Ram;Kim, Sik-Sung;Son, Woo-Sung
    • The korean journal of orthodontics
    • /
    • v.32 no.5 s.94
    • /
    • pp.343-353
    • /
    • 2002
  • This study was designed to investigate the stress distribution of alveolar bone in case of on masse retraction with lingual K-loop archwire using the 3-dimensional photoelastic stress analysis followed by stress freezing process. Lingual K-loop archwire which had loop in 15mm height was used and activated by retraction force of 350gm per each side. The results were as follows 1. Central incisor : As the closer side to crown, the larger tensile stress was distributed at both mesial and labial surfaces and the larger compressive stress was distributed at distal surface. As the closer side to root apex, the larger compressive stress was distributed at lingual surface. The compressive stress was distributed at root apex. 2. Lateral incisor : The tensile stress was distributed at the coronal side of mesial surface. The compressive stress was distributed at distal surface. As the closer side to crown, the larger tensile stress was distributed at labial surface. The tensile stress was distributed at coronal side and the compressive stress was distributed at apical side of lingual surface. The compressive stress was distributed at root apex. 3. Canine The tensile stress was distributed at coronal side and the compressive stress was distributed at apical side of mesial surface. The tensile stress was distributed at distal surface. As the closer side to crown, the larger tensile stress was distributed at both mesial and distal surfaces. The compressive stress was distributed at root apex. 4. Second premolar : The tensile stress was distributed at mesial surface. The compressive stress was distributed at coronal side and the tensile stress was distributed at apical side of distal surface. The compressive stress was distributed at coronal side of buccal surface. As the closer side to crown, the larger tensile stress was distributed at lingual surface. The compressive stress was distributed at root apex. 5. First molar . As the closer side to crown, the larger tensile stress was distributed at both mesial and distal surfaces. No stress was distributed at buccal surface and palatal root apex. As the closer side to crown, the larger tensile stress was distributed at both lingual surfaces. The compressive stress was distributed a4 buccal root apexes. 6. Second molar The compressive stress was distributed at all root apexes. As the closer side to crown, the larger compressive stress was distributed at both mesial and lingual surfaces, and the larger tensile stress at both distal and buccal surfaces. Transverse bowing effect was observed in on-masse retraction with lingual K-loop archwire, however vertical towing effect was not. Rather, reverse vortical bowing effect was developed.

CLINICAL STUDY OF THE ROTATIONAL INTENTIONAL REPLANTATION FOR THE TREATMENT OF INTRA-ALVEOLAR CROWN-ROOT FRACTURE : CASE REPORT (치관-치근 파절치의 회전을 이용한 의도적 재식술의 치험례)

  • Seo, Young-Ju;Lee, Nan-Young;Lee, Sang-Ho;Lee, Chang-Seop
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.3
    • /
    • pp.465-470
    • /
    • 2003
  • Transverse and oblique crown-root fractures constitute a major therapeutic problem, particularly in young dentitions. Because crown-root fracture may involve enamel, dentin, pulp, and periodontal tissues, management of the injuries must be modified accordingly. When the fracture line was located under the alveolar crest. there are several methods for crown-root fractured teeth with pulp exposure, such as extruding the root fragment with orthodontic force and restoring it, or intentionally extracting the tooth and replanting it to a position which it can be restored. This case, the fractured tooth is intentionally extracted atraumatically, and replanted by rotating approximately 180 degree into the original socket and fixing with an orthodontic wire. At the 8-month recall examination, the root still showed normal mobility and there was not observed any inflammatory or replacement root resorption in the periapical radiograph.

  • PDF

Esthetic restoration of subgingival crown-root fractured maxillary anterior tooth using surgical extrusion (외과적 정출술을 통한 치은 하방 치경부 파절선이 있는 상악 전치부의 심미 보철 치료)

  • Lee, So-Jin;Kim, Yu-Jin;Park, Young-Bum;Cho, Kyoo-Sung;Chung, Moon-Kyu
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.3
    • /
    • pp.204-209
    • /
    • 2012
  • Surgical extrusion, immediate extrusion following tooth luxation, is a method to preserve one's natural tooth and achieve esthetic restoration without additional periodontal surgery when subgingival dental caries or crown fracture occurs. A 16-year-old male was referred to the clinic from the department of operative dentistry for the esthetic restoration of maxillary left lateral incisor. Due to the crown to root fracture, the tooth was endodontically treated with a buccal crown length of 4 mm. When the palatal flap was elevated, the mesiopalatal cervical fracture area was situated 3-4 mm subgingivally. Crown lengthening was achieved through surgical extrusion. After 3 months of clinical observation and provisional restoration, the maxillary left central incisor was restored with all ceramic crown and obtained a satisfactory clinical result.