• Title/Summary/Keyword: 치과학

Search Result 8,059, Processing Time 0.041 seconds

Clinical Factors Affecting the Results of Regenerative Endodontic Procedure (재생근관치료 결과에 영향을 미치는 인자의 분석)

  • Kim, In-Ki;Kim, Hyuntae;Song, Ji-Soo;Shin, Teo Jeon;Hyun, Hong-Keun;Kim, Young-Jae;Kim, Jung-Wook;Jang, Ki-Taeg
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.48 no.4
    • /
    • pp.449-459
    • /
    • 2021
  • This study retrospectively analyzed the effect of clinical factors on the outcomes of REP(regenerative endodontic procedure). Patients who received the REP using triple antibiotic paste due to trauma or fracture of dens evaginatus from February, 2011 to January, 2020 were included in the study. Finally, 57 teeth in 54 patients were selected. Investigated clinical factors were as follows: intentional bleeding, etiology, and root development stage. Treatment outcomes evaluated were as follows: improvement of subjective symptoms, changes in the periapical lesion, and the amounts of root development after REP. To compensate for differences in angulation and position between repeated radiographic examinations, images were aligned by Turboreg plugin. To evaluate the amounts of root development, apical diameter, root area, and root length were measured by ImageJ software. Among the aforementioned factors, intentional bleeding had no significant effect on treatment results. Regarding the etiology, the increase in the root area and the root length was significantly less in trauma cases than in dens evaginatus fracture cases. Considering root development stage, more immature teeth presented more increase in the root area.

Minor Orthodontic Treatment Using NiTi Wire Exerting Light Force: Case Reports (약한 힘을 내는 NiTi 와이어를 이용한 부분교정: 증례보고)

  • Hwayeon, An;Seonmi, Kim;Namki, Choi
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.49 no.4
    • /
    • pp.505-513
    • /
    • 2022
  • Minor orthodontic treatment using a thin wire with high elasticity can shorten the treatment period and reduce the load on the anchorage by the application of light force. Since it can be applied immediately without a dental laboratory procedure and does not require the patient's cooperation, it can be clinically useful. The cases reported here have led to positive results in short periods of treatment, using only a segmented straight 0.012 inch NiTi wire and flowable resin to address various locations within the oral cavity, such as the anterior teeth, premolars, and molars.

Cantilever-Type Traction Appliance for Mandibular First Permanent Molars with Eruption Disturbances (하악 제1대구치 맹출 장애에서 Cantilever-Type의 견인 장치를 활용한 맹출 유도)

  • Lim, Heejung;Lee, Eungyung;Jeong, Taesung;Shin, Jonghyun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.48 no.2
    • /
    • pp.229-236
    • /
    • 2021
  • Eruption disturbances of the mandibular first molars can cause multiple problems in occlusal development although they are extremely rare. Early diagnosis and treatment are very important to prevent complications associated with eruption disturbances. The present case report describes the treatment of two cases of eruption disturbances of the mandibular first permanent molar. A fixed appliance composed of a cantilever spring with mandibular second deciduous molar as an anchor tooth was used to tract the impacted mandibular first permanent molar. The success of both cases shows that this novel traction appliance can be used to induce the eruption of an impacted mandibular first permanent molar within a short time in patients with intact mandibular second deciduous molar as an anchor tooth.

Comparative study of volumetric change in water-stored and dry-stored complete denture base (공기중과 수중에서 보관한 총의치 의치상의 체적변화에 대한 비교연구)

  • Kim, Jinseon;Lee, Younghoo;Hong, Seoung-Jin;Paek, Janghyun;Noh, Kwantae;Pae, Ahran;Kim, Hyeong-Seob;Kwon, Kung-Rock
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.1
    • /
    • pp.18-26
    • /
    • 2021
  • Purpose: Generally, patients are noticed to store denture in water when removed from the mouth. However, few studies have reported the advantage of volumetric change in underwater storage over dry storage. To be a reference in defining the proper denture storage method, this study aims to evaluate the volumetric change and dimensional deformation in case of underwater and dry storage. Materials and methods: Definitive casts were scanned by a model scanner, and denture bases were designed with computer-aided design (CAD) software. Twelve denture bases (upper 6, lower 6) were printed with 3D printer. Printed denture bases were invested and flasked with heat-curing method. 6 upper and 6 lower dentures were divided into group A and B, and each group contains 3 upper and 3 lower dentures. Group A was stored dry at room temperature, group B was stored underwater. Group B was scanned at every 24 hours for 28 days and scanned data was saved as stereolithography (SLA) file. These SLA files were analyzed to measure the difference in volumetric change of a month and Kruskal-Wallis test were used for statistical analysis. Best-fit algorithm was used to overlap and 3-dimensional color-coded map was used to observe the changing pattern of impression surface. Results: No significant difference was found in volumetric changes regardless of the storage methods. In dry-stored denture base, significant changes were found in the palate of upper jaw and posterior lingual border of lower jaw in direction away from the underlying tissue, maxillary tuberosity of upper jaw and retromolar pad area of lower jaw in direction towards the underlying tissue. Conclusion: Storing the denture underwater shows less volumetric change of impression surface than storing in the dry air.

A Morphometric Study of the Stainless Steel Permanent Molar Crown with Three-Dimensional Scanner (3차원 스캐너를 이용한 대구치용 기성금속관의 형태에 관한 계측학적 연구)

  • Shin, Jonghyun;Lee, Hyeongjik;Jeong, Taesung;Kim, Shin;Kim, Jiyeon
    • Korean Journal of Dental Materials
    • /
    • v.45 no.4
    • /
    • pp.287-300
    • /
    • 2018
  • The aim of this study was to compare the morphological characteristics of two types of stainless steel permanent molar crowns using three-dimensional scanners and the morphological changes of these crowns after crimping. Two types of stainless steel permanent molar crowns, PO-96 and PERMACROWN were scanned using three-dimensional scanner. Crown size, crown index (ratio of buccolingual diameter to mesiodistal diameter at height of contour), cervical convergency of crown were measured. Stainless steel crowns were crimped and re-scanned with three-dimensional scanner. Morphological changes of stainless steel permanent molar crowns were analyzed. As for the crown index, maxillary PERMACROWN was larger buccolingually and smaller mesiodistally than maxillary PO-96 and mandibular PERMACROWN was smaller buccolingually and larger mesiodistally than mandibular PO-96. Maxillary PO-96 was more convergent to cervical mesiodistally than maxillary PERMACROWN and mandibular PO-96 was more convergent to the cervical mesiodistally, buccolingually than mandibular PERMACROWN. Both types of stainless steel permanent molar crowns showed reduction of cervical circumference after crimping. Two products were morphologically different in crown size, shape and cervical convergence. Although both types of stainless steel permanent molar crowns are pre-contoured type, additional crimping is needed to achieve better marginal adaptation.

Full mouth rehabilitation in patient with deep bite, inter-dental arch discrepancy and loss of vertical dimension: a case report (과개교합과 치열궁부조화 및 수직고경 감소를 가진 환자의 전악수복증례)

  • Song, Han-Sol;Lee, Ye-Jin;Ko, Kyung-Ho;Huh, Yoon-Hyuk;Cho, Lee-La;Park, Chan-Jin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.37 no.3
    • /
    • pp.157-170
    • /
    • 2021
  • Loss of posterior bite support might cause unstable occlusal relationship and when the mandible slides forward in the centric or habitual occlusion, excessive load is applied to the anterior region followed by causing the occlusal plane to collapse or leading to a decrease in occlusal vertical dimension. In addition, disorder of temporomandibular joint function may occur. The inter-dental arch discrepancy causes a mismatch in the vertical and horizontal overlap of the anterior and posterior regions. The deep bite in the anterior region and the scissor bite in the posterior region cause unstable occlusal contact and insufficient occlusal contact area. This report was to rehabilitate a patient with above-mentioned complex problems. Physiologic adaptation to increased vertical dimension and new occlusal plane were evaluated using provisional prostheses, and definitive prostheses was fabricated using cross-mounting technique. Stable occlusion, harmonious teeth overlap and adequate occlusal plane were established, so functionally and aesthetically satisfactory results are obtained.

Effect of Virtual Reality Distraction on Pain and Anxiety in Children during Local Anesthesia (소아환자의 국소마취 시 Virtual Reality 주의분산이 통증 및 두려움에 미치는 효과)

  • Kim, Doosoo;Lee, Sangho;Lee, Nanyoung;Jih, Myeongkwan;Ahn, Jihye
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.48 no.1
    • /
    • pp.95-104
    • /
    • 2021
  • The purpose of this study was to evaluate the effect of virtual reality distraction on pain and anxiety in children during local anesthesia. Local anesthesia was administered to 3 groups: a control group without distraction, a group watching TV, and a group using a virtual reality device. The pulse rate and oxygen saturation rate were measured before and at the time of local anesthesia to assess the patients' pain and anxiety, and the Wong-Baker Faces Pain Rating Scale was completed after local anesthesia. The group using the virtual reality device had a significantly lower heart rate change and lower Wong-Baker Faces Pain Rating Scale score than those in the control group and the group watching TV (p < 0.05). The greatest difference in heart rate change and Wong-Baker Faces Pain Rating Scale score, between the control and virtual reality distraction groups, was seen in 5 - 7-year-olds and a Frankl's behavior rating scale grade of 3. The virtual reality device alleviated pain and reduced anxiety in children during local anesthesia.

Full mouth rehabilitation of patient with severe dental caries with implant fixed prosthesis fabricated with milling and 3D printing method: A case report (밀링 및 3D 프린팅 방법으로 제작된 임플란트 보철물을 이용한 심한 우식 환자의 완전 구강 회복 증례)

  • Kim, Taeyoon;Lee, Jun-Suk;Hong, Seoung-Jin;Kim, Hyeong-Seob;Kwon, Kung-Rock
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.3
    • /
    • pp.288-295
    • /
    • 2019
  • Passive fit of prosthesis is an essential property of implant supported prosthesis for long term success and minimization of complications. And the property is determined mostly by fabrication procedure. There were limitations of extensive implant prosthesis because conventional casting method generate contraction error of long span prosthesis. However, Computer-aided design/Computer-aided manufacturing (CAD/CAM) technology of 3D printing and milling metal framework can overcome those limitations. This case is a full mouth rehabilitation using extensive implant fixed prosthesis. Removable interim prosthesis was made for esthetic, functional evaluation and a guide for implant insertion. After the insertion, implant fixed interim prosthesis was delivered. After additional evaluation and adjustment, final prosthesis was designed with CAD, the fabricated with CAM. Milling technique was used for anterior screw type implant superstructure and 3D printing technique was used for the anterior and posterior implant copings. Fit of the final restoration was favorable. The practitioner and patient were both esthetically and functionally satisfied with the final result.

The use of implant surveyed fixed prosthesis for removable partial denture with a few unilateral remaining teeth: A case report (편측 소수 잔존치 증례에서 CAD software를 활용한 planning 및 임플란트 서베이드 고정성 보철물을 이용한 국소의치 수복: 증례보고)

  • Park, Jeongkeun;Kim, Jong-Eun;Park, Ji-Man;Kim, Jeehwan;Shim, June-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.3
    • /
    • pp.254-262
    • /
    • 2019
  • As implant can be covered by National Health Insurance Service (NHIS), it was increased the interest in the removable partial denture (RPD) with the surveyed fixed prosthesis supported by implant fixture. To achieve predictable result, it needs the prudent implant planning by basic principles of RPD and patient's residual ridge. This 67 years old age male had a few unilateral remaining teeth, and hoped the treatment covered by NHIS. As using CAD software, the position of implant is planned with regarding to occlusal table of provisional denture, basic principles of RPD, and resorbed residual ridge. The definitive prostheses can ensure the stability and retention of removable prosthesis. When planning implant fixed prostheses, the digital technique was utilized to consider basic principle of RPD and resorbed residual ridge. As a result, it provided satisfactory prostheses.

Analysis of Treatment Period on the Intraoral Removable Appliance Utilizing Vertical Facial Growth on Class III Malocclusion (얼굴의 수직성장을 이용하여 III급 부정교합을 치료하는 구강내 가철식 장치의 치료기간분석)

  • Song, Jihyeo;Kim, Seong-Oh;Song, Je Seon;Lee, Jaeho;Choi, Hyung-jun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.46 no.2
    • /
    • pp.173-182
    • /
    • 2019
  • Vertical facial growth triggers the rotation of mandible to move the chin point to the downward and backward direction, which showed remarkably effective result making the less prominent chin. Recently, the intraoral removable appliance utilizing class III elastic demonstrated the vertical growth trigger mechanism. The treatment change was very fast and wearing was quite easy, compared to extraoral appliances. The purpose of this study was to verify the duration of the treatment on class III malocclusion using intraoral removable appliances, which designed to accelerate vertical facial growth. 56 patients were selected with the complaint of the protruded mandible and class III malocclusion (overjet : -3 - 0 mm, overbite : 0 - 4 mm). Information like; age at start, duration of the treatment events, type of the treatment, overjet, overbite etc. was collected and calculated. The average age of the patients delivering the initial brace was $8.75{\pm}1.10year$. Most of the anterior crossbite was resolved within 6 months. The total treatment period was $21.79{\pm}10.73months$ with the additional procedures like the alignment of anterior teeth and torque control using additional removable and fixed orthodontic appliances. The correlation study showed that patient's cooperation (p = 0.000) and the use of fixed appliance (p = 0.032) were significantly influenced on treatment duration.