• Title/Summary/Keyword: 치과전공의

Search Result 152, Processing Time 0.025 seconds

Clinical Convergence Angle of Prepared Tooth for full Veneer Crowns (전부 피개관의 치아 형성 시 축면 경사각에 대한 조사)

  • Kim, Sung-Jin;Pae, Ah-Ran;Woo, Yi-Hyung;Kim, Hyeong-Seob
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.1
    • /
    • pp.21-32
    • /
    • 2010
  • The convergence angle of a prepared tooth is a very important factor in the retention and resistance of a crown restoration. But various intraoral environments and clinician's techniques make it difficult to obtain the ideal inclination. Therefore, in this study, clinical convergence angle of a prepared tooth was investigated. The data was collected from the patient models of prosthodontic residents and the patient models of general practitioners. The images of mesiodistal and buccolingual surfaces were taken with a digital camera to evaluate the convergence angle on 'ImageJ' program. The images were classified according to the criteria (1. Clinician group, 2. Position in the dental arch, 3. The purpose of abutment preparation)and then analyzed. The mean convergence angle of a prepared tooth for Korean clinicians was $15.02^{\circ}$ (${\pm}10.13^{\circ}$). 1. It was significant in the convergence angle between the general practitioner group and the prosthodontic resident group(p<0.05). 2. It was significant between the mesiodistal and buccolingual surface in the the prosthodontic resident group(p<0.05). 3. For the general practitioner group, it was significant when anteriors and premolars were compared with molars(p<0.05). For the prosthodontic resident group, it was significant when anteriors and premolars were compared with molars (p<0.05). 4. When divided into upper and lower arches, for the general practitioner group, it showed significant difference in the buccolingual aspect(p<0.05). Also in the prosthodontic resident group, it showed significant difference in the buccolingual aspect(p<0.05). 5. Dividing left and right sides of the arches, there was no significant difference in the general practitioner group and the prosthodontic resident group(p>0.05). 6. In the general practitioner group, it was significant in the mesiodistal axial convergence angle of single crown abutment and 3 unit bridge abutment(p<0.05). In the prosthodontic resident group, it was significant in the mesiodistal and overall axial convergence angle of single crown abutment and 3 unit bridge abutment(p<0.05). Clinical convergence angle of prepared tooth in Korea was included in agreement with other studies investigating convergence angle that ranged from 10 to 22 degrees, achieved in clinical practice.

Problems to Solve and Job Enlargement on the Inclusion of Dental Hygienists in the Category of Medical Personnel (치과위생사 의료인화에 대한 현안과제와 직무확충 방안)

  • Lee, Da-Som;Han, Gyeong-Soon
    • Journal of dental hygiene science
    • /
    • v.18 no.6
    • /
    • pp.340-348
    • /
    • 2018
  • The purpose of this study was to examine the perceptions, precedent tasks, positive and negative effects, and expandable professional tasks regarding the inclusion of dental hygienists (DHs) in the category of medical personnel. This study involved a survey of 259 DHs and 128 dentists. The findings were as follows: 94.2% of DHs and 46.9% of dentists were aware of inclusion in the category of medical personnel; 95.0% of DHs and 64.1% of dentists supported the idea; and 84.9% of DHs and 51.6% of dentists recognized its legitimacy. As for precedent tasks for inclusion in the category of medical personnel, both DHs and dentists scored high points in professional consciousness in the area of occupation. Both DHs and dentists scored the highest points in the quality management of DH education and the lowest points in the unification of school systems in the area of institution. In the area of society, DHs scored high points in the persuasion of the central government, whereas dentists scored high points in collaboration among concerned organizations. Regarding the positive effects of inclusion in the category of medical personnel, both DHs and dentists scored the highest points in the expanded perception of DHs. As for its negative effects, DHs scored high points in the aggravation of salary increase, whereas dentists scored high points in the aggravation of salary increase. Regarding expandable professional tasks after the inclusion of DHs in the category of medical personnel, the management of independent periodontal care programs recorded the highest percentage both in DHs and dentists. These findings highlight the need for adequate discussions about the meanings of the inclusion of DHs in the category of medical personnel and will hopefully contribute to the rational adjustment and legalization of DHs' works with regard to their inclusion in the category of medical personnel.

Accuracy comparison of 3-unit fixed dental provisional prostheses fabricated by different CAD/CAM manufacturing methods (다양한 CAD/CAM 제조 방식으로 제작한 3본 고정성 임시 치과 보철물의 정확도 비교)

  • Hyuk-Joon Lee;Ha-Bin Lee;Mi-Jun Noh;Ji-Hwan Kim
    • Journal of Technologic Dentistry
    • /
    • v.45 no.2
    • /
    • pp.31-38
    • /
    • 2023
  • Purpose: This in vitro study aimed to compare the trueness of 3-unit fixed dental provisional prostheses (FDPs) fabricated by three different additive manufacturing and subtractive manufacturing procedures. Methods: A reference model with a maxillary left second premolar and the second molar prepped and the first molar missing was scanned for the fabrication of 3-unit FDPs. An anatomically shaped 3-unit FDP was designed on computer-aided design software. 10 FDPs were fabricated by subtractive (MI group) and additive manufacturing (stereolithography: SL group, digital light processing: DL group, liquid crystal displays: LC group) methods, respectively (N=40). All FDPs were scanned and exported to the standard triangulated language file. A three-dimensional analysis program measured the discrepancy of the internal, margin, and pontic base area. As for the comparison among manufacturing procedures, the Kruskal-Wallis test and the Mann-Whitney test with Bonferroni correction were evaluated statistically. Results: Regarding the internal area, the root mean square (RMS) value of the 3-unit FDPs was the lowest in the MI group (31.79±6.39 ㎛) and the highest in the SL group (69.34±29.88 ㎛; p=0.001). In the marginal area, those of the 3-unit FDPs were the lowest in the LC group (25.39±4.36 ㎛) and the highest in the SL group (48.94±18.98 ㎛; p=0.001). In the pontic base area, those of the 3-unit FDPs were the lowest in the LC group (8.72±2.74 ㎛) and the highest in the DL group (20.75±2.03 ㎛; p=0.001). Conclusion: A statistically significant difference was observed in the RMS mean values of all the groups. However, in comparison to the subtractive manufacturing method, all measurement areas of 3-unit FDPs fabricated by three different additive manufacturing methods are within a clinically acceptable range.

Evaluation of fitness according to application of glass fiber reinforcement for lower jaw complete denture (하악 총의치 전용의 유리섬유 보강재 적용에 따른 적합도 비교 분석)

  • Kim, Dong-Yeon;Park, Jin-Young;Bae, So-Yeon;Kang, Hoo-Won;Kim, Ji-hwan;Kim, Woong-Chul
    • Journal of Technologic Dentistry
    • /
    • v.40 no.4
    • /
    • pp.201-207
    • /
    • 2018
  • Purpose: The purpose of this study is to evaluate the fitness of lower jaw compete denture with glass fiber. Methods: Lower jaw edentulous model was selected as the master model. Ten study models were produced using Type IV stone(n=10). Lower jaw trial dentures were produced by the wax denture base and artificial teeth. Conventional complete denture (CD) group was fabricated by excluding glass fiber reinforcement (n=5). Glass fiber complete denture (GD) group was fabricated with glass fiber reinforcement (n=5). The lower jaw trial complete denture was invested using a plaster. PMMA resin was injected and curing was performed. The CD and GD groups measured the fit using silicone replica technology. The measured data was verified by t-test. Results: The anterior area of the CD group showed the smallest value. There was a statistically significant difference in the anterior area of the CD group and the GD group (p<0.05), but there was no statistically significant difference in the posterior area (p>0.05). Conclusion : Complete denture with glass fiber showed low fitness and further study is needed to apply it clinically.

Comparison of 2-dimensional marginal and internal fitness for the monolithic zirconia prosthesis using intraoral scanner and extraoral scanner: in vitro (Extraoral scanner와 intraoral scanner를 이용하여 제작된 zirconia crown의 2차원 변연 및 내면 적합도 비교: in vitro)

  • Lee, Tae-Hee;Lee, Ha-Bin;Kim, Ji-hwan
    • Journal of Technologic Dentistry
    • /
    • v.41 no.3
    • /
    • pp.187-193
    • /
    • 2019
  • Purpose: The purpose of this study was to compare two-dimensional fitness of the monolithic zirconia prosthesis by using different type of scanner. Methods: No. 26 abutment tooth of FDI system was selected for the study. Using the extraoral scanner and intraoral scanner, the abutment tooth was scanned 10 times and the scanned files were saved as STL files. CAD/CAM system was used to produce the monolithic zirconia prosthesis. marginal and internal gap of the monolithic zirconia prosthesis were measured by digital microscope(x160) and applied silicone replica technique was applied. t-test, a statistical software, was used to perform data analysis. Results: Marginal gap $mean{\pm}SD$ of the monolithic zirconia prosthesis was $33{\pm}7.5{\mu}m$ with extra oral scanner and $34.7{\pm}11.1{\mu}m$ with intraoral scanner. axial gap mean was $40.5{\pm}3.5{\mu}m$ with extra oral scanner and $44.6{\pm}11.6{\mu}m$ with intraoral scanner. occlusal gap mean was $110.1{\pm}25.4{\mu}m$ with extra oral scanner and $64{\pm}9.7{\mu}m$ with intraoral scanner. Conclusion: In this study, fabricating zirconia prosthesis with different type of scanner was clinically applicable.

Evaluation of marginal and internal accuracy of provisional crowns manufactured using digital light processing three-dimensional printer (DLP 방식의 3D 프린터로 제작된 임시 보철물의 변연 및 내면 정확도 평가)

  • Noh, Mi-Jun;Lee, Ha-Bin;Kim, Ji-Hwan
    • Journal of Technologic Dentistry
    • /
    • v.44 no.2
    • /
    • pp.31-37
    • /
    • 2022
  • Purpose: The aim of this study was to evaluate the accuracy of provisional crowns manufactured using a milling machine and a digital light processing (DLP) printer. Methods: A full-contour crown was designed using computer-aided design software. Provisional crowns of this design were manufactured using a milling machine and using a DLP three-dimensional (3D) printer (N=20). The provisional crowns were digitized with an extraoral scanner, and 3D deviation analysis was applied to the scanned data to confirm their accuracy. An independent t-test was performed to detect the significant differences, and the Kolmogorov-Smirnov test was used for analysis (α=0.05). Results: No significant differences were found among the precision of marginal surface between the printed and milled crowns (p=0.181). The trueness of marginal and internal surfaces of the milled crowns were statistically higher than those of the printed crowns (p=0.024, p=0.001; respectively). Conclusion: The accuracy of provisional crowns manufactured using a milling machine and a 3D printer differed significantly except with regards to the precision of the internal surface. However, all the crowns were clinically acceptable, regardless of the manufacturing method used.

A comparison of conventional intraoral radiography and computer imaging techniques for the detection of proximal surface calculus (구내방사선사진과 컴퓨터영상의 치아 인접면 치석 진단능의 비교)

  • Kang Byung-Cheol
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.24 no.1
    • /
    • pp.23-28
    • /
    • 1994
  • 전남대학교 치과대학 학생을 대상으로 평행촬영법으로 촬영한 168장의 구내방사선사진을 디지털 영상으로 변환하여, 필름상의 치석 유무 판독 결과와 모니터상의 판독 결과를 비교하였다. 3명의 구강악안면방사선학 전공 치과의사가 판독을 하되 필름상의 판독 결과를 판정의 기준으로 하였다. 디지털 영상은 상업용 필름-비디오 변환장치, 486DX PC, 그리고 PcVision과 frame grabber을 이용하여 얻었다. 모니터상의 개개 구내방사선사진상은 700×480 pixel로 나타내었다. 디지털 영상의 치석진단의 sensitivity는 0.79-0.90(평균 0.86) 이었고, specificity는 0.03-0.43(평균 0.17) 이었다.

  • PDF

A comparison of periapical radiographs and their digital images for the detection of dental caries (인접면 치아우식증의 진단의 치근단 X선사진과 디지털영상의 비교)

  • Kang Byung-Cheol
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.24 no.1
    • /
    • pp.31-35
    • /
    • 1994
  • 전남대학교 치과진료처에 내원한 환자의 구내방사선사진중 1단계 (Cl: 30개 병소)또는 2단계(C2: 213.8병소)의 인접면 치아우식을 가진 방사선사진 168장을 연구대상으로 하였다. 이들 방사선사진은 코닥사의 Ektaspeed(E group) 필름을 사용하여 평행촬영법으로 촬영하였다. 168장의 방사선사진에 대하여 1단계 및 2단계 치아우식증을 4명의 구강악안면방사선학을 전공한 치과의사들이 같이 판독하여 그 결과를 기록하였다. 또한 168장의 방사선사진을 필름-비디오 변환장치를 이용하여 디지털 영상으로 전환하였다. 이때 486 DX PC에 PCVision과 frame grabber를 이용하였다. 각각의 구내방사선사 진영상은 17"크기의 1280×768픽셀의 해상도를 갖는 모니터상에서 256단계 흑화도를 갖는 700×480픽셀로 제시되었다. 모니터상에서의 치아우식 판독 결과를 구내방사선사진 판독 결과와 비교하였다. 그 결과 sensitivity는 0.98이었다. 1단계 치아우식은 0.87, 2단계 치아우식 은 1.00의 sensitivity를 나타내었다.

  • PDF

Comparison of Major and Job Satisfaction of Students and Graduates in Dental Hygiene and Nursing (대전 일부 치위생학과와 간호학과 재학생 및 졸업생의 전공과 업무 만족도 비교)

  • Baek, Seong-Min;Song, Da-Hye;Park, Jin-Seul;Bae, Jeong-Yeon;Jeong, Won-Seok;Hwang, Soo-Jeong
    • Journal of dental hygiene science
    • /
    • v.13 no.4
    • /
    • pp.378-385
    • /
    • 2013
  • Although dental hygiene has haven a special domain of knowledge and its own business territory, people have misunderstandings about dental hygienists as nurses or nirses' aides in Korea. Inadequate knowledge could make negative results for university applicants to choose department of dental hygiene. This study was aimed to compare major and job satisfaction of students and graduates in dental hygiene and nursing for objective comparison and suggestion for dental hygiene. The subjects were 98 dental hygiene students, 113 nursing students, 53 dental hygienists, and 53 nurses by convenience sampling in Daejeon. The questionnaire consisted of satisfaction of college life, social identity, career path and job. ANOVA with Tukey post-hoc analysis was used with SPSS 20.0 program. Although dental hygiene students scored lower than nursing students in satisfaction of college life, social identity, career path and job, dental hygienists, nurse and dental hygiene students didn't have different satisfaction of job. Dental hygienists scored the lowest in relation with clinical work and major curriculum, and sexual discrimination. Nurses scored the lowest in working condition and salary. Dental hygienists and dental hygiene students had lower scores in information and advice of career path, entrance to graduate school, stable work, family's pride of my major, social position and so on. We suggested the community of dental hygiene should try to promote dental hygienists to public, the community of dentists should give the stable working condition, and the department of dental hygiene should improve the major curriculum to relate with clinical work.

Analysis of the 2-dimensional marginal fit of the occlusal surface and the 3-dimensional accuracy of the inner surface of the occlusal surface according to the inlay prosthesis structure made of composite resin (복합레진으로 제작한 인레이 보철물 구조에 따른 교합면 부위의 2차원 변연 적합도 및 내면 부위의 3차원 정확성 분석)

  • Kim, Dong-Yeon;Lee, Tae-Hee;Park, Dong-In;Park, Jin-Young;Jeong, Il-Do;Lee, Ha-Na;Kim, Ji-Hwan;Kim, Woong-Chul
    • Journal of Technologic Dentistry
    • /
    • v.41 no.1
    • /
    • pp.21-27
    • /
    • 2019
  • Purpose: To evaluate 2D and 3D of occulsal, mesial-occlusal and mesial-occlusal-distal cavity of composite resin inlay. Methods: Abutment tooth 16, 36 of FDI system was selected for the study. Inlay prostheses classified as occlusal cavity (OC group), mesial-occlusal (MOC) and mesial-occlusal-distal cavity (MODC) were prepared using composite resin. Composite resin was injected with composite resin in prepared tooth cavity and then photopolymerized with UV light. Additional thermal polymerization was performed. Marginal gap of composite resin inlays were measured by digital microscope(x160) with silicone replica technique. The data was analyzed from statistical software for Kruskal-Wallis test (${\alpha}=0.05$). 3-dimensional analysis was analyzed through superimposition method. Results: The smallest 2D marginal fit measure of the three groups was $47.0{\pm}21.6{\mu}m$ in the MOC group. The largest 2D marginal was $69.1{\pm}33.8{\mu}m$ in the MODC group. In the trueness of the three groups, the most accurate figure was $14.4{\pm}2.3{\mu}m$ for the MODC group. In Precision, the most accurate figure was $14.5{\pm}4.3{\mu}m$ for the MODC group. Conclusion : In this study, 2D marginal fit of OC, MOC, and MODC cavities fabricated with composite resin was applicable to all clinical applications. In the 3D inner surface accuracy evaluation, the MODC group showed the accuracy results.