Analysis of the 2-dimensional marginal fit of the occlusal surface and the 3-dimensional accuracy of the inner surface of the occlusal surface according to the inlay prosthesis structure made of composite resin  

Kim, Dong-Yeon (Institute for Health Science, College of Public Health Science, Korea University)
Lee, Tae-Hee (Department of Dental Laboratory Science & Engineering, College of Health Science, Korea University)
Park, Dong-In (Department of Dental Laboratory Science & Engineering, College of Health Science, Korea University)
Park, Jin-Young (Institute for Health Science, College of Public Health Science, Korea University)
Jeong, Il-Do (Institute for Health Science, College of Public Health Science, Korea University)
Lee, Ha-Na (Department of Dental Laboratory Science & Engineering, College of Health Science, Korea University)
Kim, Ji-Hwan (Department of Dental Laboratory Science & Engineering, College of Health Science, Korea University)
Kim, Woong-Chul (Department of Dental Laboratory Science & Engineering, College of Health Science, Korea University)
Publication Information
Journal of Technologic Dentistry / v.41, no.1, 2019 , pp. 21-27 More about this Journal
Abstract
Purpose: To evaluate 2D and 3D of occulsal, mesial-occlusal and mesial-occlusal-distal cavity of composite resin inlay. Methods: Abutment tooth 16, 36 of FDI system was selected for the study. Inlay prostheses classified as occlusal cavity (OC group), mesial-occlusal (MOC) and mesial-occlusal-distal cavity (MODC) were prepared using composite resin. Composite resin was injected with composite resin in prepared tooth cavity and then photopolymerized with UV light. Additional thermal polymerization was performed. Marginal gap of composite resin inlays were measured by digital microscope(x160) with silicone replica technique. The data was analyzed from statistical software for Kruskal-Wallis test (${\alpha}=0.05$). 3-dimensional analysis was analyzed through superimposition method. Results: The smallest 2D marginal fit measure of the three groups was $47.0{\pm}21.6{\mu}m$ in the MOC group. The largest 2D marginal was $69.1{\pm}33.8{\mu}m$ in the MODC group. In the trueness of the three groups, the most accurate figure was $14.4{\pm}2.3{\mu}m$ for the MODC group. In Precision, the most accurate figure was $14.5{\pm}4.3{\mu}m$ for the MODC group. Conclusion : In this study, 2D marginal fit of OC, MOC, and MODC cavities fabricated with composite resin was applicable to all clinical applications. In the 3D inner surface accuracy evaluation, the MODC group showed the accuracy results.
Keywords
Marginal fit; Accuracy; 3-Dimension; Inlay; Composite resin;
Citations & Related Records
Times Cited By KSCI : 7  (Citation Analysis)
연도 인용수 순위
1 Ausiello P, Ciaramella S, Fabianelli A, Gloria A, Martorelli M, Lanzotti A, watts DC. Mechanical behavior of bulk direct composite versus block composite and lithium disilicate indirect restorations by CAD-FEM modeling. Dent Mater. 33, 690-701, 2017.   DOI
2 Bae EJ, Jeong ID, Kim WC, Kim JH. A study on the machining accuracy of dental digital method focusing on dental inlay. J Adv Prosthodont, 10, 321-327, 2018.   DOI
3 Bae SY, Park JY, Jeong ID, Kim HY, Kim JH, Kim WC. Three-dimensional analysis of marginal and internal fit of copings fabricated with polyetherketoneketone(PEKK) and zirconia. J Prosthodont Res, 61, 106-112, 2017.   DOI
4 Bosch G, Ender A, Mehl A. A 3-dimensional accuracy analysis of chairside CAD/CAM milling processes. J Prosthet dent, 112, 1425-1431, 2014.   DOI
5 Cho BH, Lee MJ, Im MK, Lee KW, Son HH: A comparative study on marginal leakage of CAD/CAM-fabricated ceramic inlay. J Kor Acad Cons Dent, 22, 702-709, 1997.
6 Choi SY, Jeong SW, Hwang YC, Kim SH, Yun Chang, Oh WM, Hwang IN. Shear bond strength of repaired composite resin restorations. J Korean Acad Conserv Dent, 27, 569-576, 2002.   DOI
7 Christensen GJ. Acceptability of alternatives for conservative restoration of posterior teeth. J Esthet Dent, 7,228-232, 1995.   DOI
8 Chung SY, Cho JH, Lee KB, Choi YH, Song KB. Structural equation modeling for association between patient satisfaction and quality of life after implant surgery. J Korean Acad Prosthodont, 49, 291-299, 2011.   DOI
9 Grenade C, Mainjot A, Vanheusden A: Fit of single tooth zirconia copings: comparison between various manufacturing processes. J Prosthet Dent, 105, 249-255, 2011.   DOI
10 Jeon JH, Kim DY, Lee JJ, Kim JH, Kim WC. Repeatability and reproducibility of individual abutment impression, assessed with a blue light scanner. J Adv Prosthodont, 8, 214-218, 2016.   DOI
11 Kim DY, Kim JH, Kim HY, Kim WC. Comparison and evaluation of marginal and internal gaps in cobalt-chromium alloy copings fabricated using subtractive and additive manufacturing. J Prosthodont Res, 62, 56-64, 2018.   DOI
12 Kim DY, Lee KE, Jeon JH, Jeon JH, Kim JH, Kim WC. Evaluation of the reproducibility of various abutments using a blue light model scanner. J Adv Prosthodont, 10, 328-334, 2018.   DOI
13 Kim JY, Choi KK, Park SJ. Replacement of posterior restorations. J Korean Acad Conserv Dent, 31, 460-469, 2006.   DOI
14 Kim JT, Park JY, Kim WC, Kim JH. Evaluation of Flexural strength and surface porosity of three indirect composite resins. J Korean Acad dent Tech, 39, 9-16, 2017.
15 Lee JJ, Jeong ID, Kim CM, Park JY, Kim JH, Kim WC. Comparison of accuracy of digital data obtained by intra-oral scanner and extraoral scanner. J Korean Acad dent Tech, 37, 191-197, 2015.   DOI
16 Pjetursson BE, Sailer I, Makarov NA, Zwahlen M, Thoma DS. All-ceramic or metal-ceramic tooth-supported fixed dental prostheses (FDPs)? A systematic review of the survival and complication rates. Part II: Multipleunit FDPs. Dent Mater, 31, 624-639, 2015.   DOI
17 Lee SH, Yi YJ, Jo DW. Full-mouth rehabilitation in an amelogenesis imperfecta patient with anterior open bite using CAD/CAM system. J Korean Acad Prosthodont, 55, 410-418, 2017.   DOI
18 Molin M, Karlsson S: The fit of gold inlays and three ceramic inlay systems: a clinical and in vitro study. Acta Odontol Scand, 51, 201-206, 1993.   DOI
19 Mormann WH, Schug J. Grinding precision and accuracy of fit of CEREC 2 CAD/CIM inlays. J Am Dent Assoc, 128, 47-53, 1997.   DOI
20 Rippe MP, Monaco C, Volpe L, Bottino MA, Scotti R, Valandro LF. Different methods for inlay production: effect on internal and marginal adaptation, adjustment time, and contact point. Oper Dent, 42, 436-444, 2017.   DOI
21 Yeom MO, Lee JH, Shin SY, Sin SC, Cho JW. The study on the shade color change that depends on the kind of zirconia core and the porcelain thickness. J Korean Acad dent Tech, 32, 341-350, 2010.