• Title/Summary/Keyword: 치과기공물

Search Result 154, Processing Time 0.029 seconds

Full mouth prosthetic rehabilitation base on making plan: a case report (체계적 계획을 통한 전악고정성 보철물 제작 증례)

  • Kim, Wook Tae
    • Journal of Technologic Dentistry
    • /
    • v.40 no.3
    • /
    • pp.183-190
    • /
    • 2018
  • Purpose: The purpose of this study was to evaluated the process of model analysis, design, and production for a full mouth prosthetic rehabilitation of function, esthetics, and pronunciation. Methods: This is a case report of class III malocclusion with a severe anterior incisor occlusion and a prosthetic treatment of patient with poor occlusion of posterior teeth. A provisional restoration based on the diagnostic wax-up was applied to the patient. And then functions, esthetics, and occlusal stability were observed during 4 week tracking period. Final restorations were delivered and evaluated based on a systematic analysis, diagnosis and treatment plan. Results: We confirms that this case study obtained the satisfactory results in terms of functions and esthetics. Conclusion : If we can give the patient the continuous evaluation and progress monitoring, we expect the dentist and the dental technician to design the prosthesis successfully.

A Finite Element Analysis of Stress Distribution in the Tooth and Crown According to Design of Esthetic Crown (유한요소법을 이용한 심미치관보철의 설계에 따른 치아와 보철물의 응력분산에 관한 연구)

  • Lee, Myung-Kon;Chung, In-Sung;Kim, Ji-Hwan
    • Journal of Technologic Dentistry
    • /
    • v.21 no.1
    • /
    • pp.115-121
    • /
    • 1999
  • This investing was carried out to evaluate the alteration of stress distribution on teeth and esthetic crowns. Analyzing the stress distribution by the two-dimensional finite element methods, a model of lower 1st molar according to the porcelain fused metal crown an the porcelain fused glass ceramic core crown and the all glass ceramic crown. 1. The pattern of stress distribution showed no apparent differences. 2. The greatest von Mises values were concentrated around the central fossa of all esthetic crowns. The greatest Maximum principle value were concentrated around the interface between the base of esthetic crown and the abutment tooth. It was found that the apatite glass ceramic could be applicable for use in dental crown prosthesis.

  • PDF

Prosthetic restorations with cementless screw-retained implant systems: a case report (시멘트리스 나사 유지형 임플란트 시스템을 이용한 보철물 수복 증례)

  • Young-hae Jung;Im-Sun Kim
    • Journal of Technologic Dentistry
    • /
    • v.45 no.4
    • /
    • pp.124-130
    • /
    • 2023
  • This study aims to describe the clinical experience of single and bridge crowns fabricated using a cementless screw-retained implant prosthesis system. In the case of single crown (#37), regular link (HDL) was used, and bridge crowns (#15~#24), (#26~#27), (#17~#14) (#24~#26) were fabricated by selecting regular link and short link considering the vertical height. One abutment was hex shaped to ensure that it could be mounted while preventing insertion and prosthesis rotation. The advantages of cementless implant prosthesis include shorter chair time and periodic care, strong retention with LINK abutment, safety from inflammation, bacterial infection, and complications due to peri-implant cement, and high patient satisfaction. Dentists should double-check the position of the implant fixture and dental technicians should continuously manage the fit of the link and prosthesis with digital equipment to reduce screw loosening and fractures.

Comparison of crown designs of different dental occupational groups, using CAD-CAM (CAD-CAM을 이용하여 디자인한 금관의 치과 직업군에 따른 형태 비교)

  • Kim, TaeHyeon;Kim, Jong-Eun;Lee, Ah-Reum;Park, Young-Bum
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.3
    • /
    • pp.234-238
    • /
    • 2016
  • Purpose: Increasing use of computer aided design-computer aided manufacturing (CAD-CAM) system and number of design software made design of restoration easy and quick. Outcome of restoration has been dependent on dental technician's wax up proficiency, dentists can design restoration for themselves now. This study aims to investigate the outcome of restoration designs, according to handling skill of CAD-CAM design tool. Materials and methods: A patient's mandibular right 1st molar was prepared. After taking impression, stone model was made, scanned the stone model with 3 shape intra-oral scanner, stereolithography (STL) file was extracted. With 3shape dental designer, one dental technician with more than 5 years work experience (designer 0) and three dental technicians with less than 2years work experience (designer 1, 2, 3-group DT) and 4 1st year residents (designer 4, 5, 6, 7-group RT) designed gold crown on the same STL file. Designed crown's MD (mesio-distal) and BL (bucco-lingual) diameter, height of crown, inter-cuspal distance, number of occlusal contact points were compared. Statistical analysis was carried out, test of normality within each group, using independent t-test. Number of contact points were compared, using Wilcoxon signed-rank test. Results: There was no significant difference between group DT and group RT. Number of contact points also resulted in no significant difference. Conclusion: The outcome of each designed crowns showed no statistical differences, in values which can be expressed as numbers. Subjective factors were different. With increasing proficiency in handling designing software, fabrication of restorations according to each designer's occlusal concept can be made easy.

The Infection Control of Dental Impressions (치과용 인상체의 감염 관리)

  • Lee, Jin-Han
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.2
    • /
    • pp.183-193
    • /
    • 2013
  • The characteristics of dental treatment makes the dental staff frequently contact with patient directly. Also the daily use of high-handpieces, sharp instruments, and needles often causes bleeding on oral cavity. Therefore, the risk of cross transmission grows up. The pathogen from dental practice could spread on not only the practice itself but also the dental laboratory with contaminated impressions and prosthesis. Dental clinic staffs (dentists, dental hygienists and dental technicians) should recognize all the patients have a possibility of cross contamination, and try to prevent the transmission of infection by proper infection control. In this study, we review the articles about disinfection methods and chemical infection agents used for dental impressions, and try to figure out the suitable and effective infection control system of dental impressions.

Importance and requirements for dental prosthesis order platform services: a survey of dental professionals (치과 보철물 거래 플랫폼 서비스의 중요성과 요구사항: 치과 전문가 설문조사)

  • Gyu-Ri Kim;Keunbada Son;Du-Hyeong Lee;So-Yeun Kim;Myoung-Uk Jin;Kyu-Bok Lee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.39 no.3
    • /
    • pp.105-118
    • /
    • 2023
  • Purpose: This study aimed to gain better understanding of the importance of dental prosthesis order platform services and to identify the essential elements for their enhancement and wider adoption among dental professionals. Materials and Methods: A survey was conducted to assess the perspectives of dentists, dental technicians, dental hygienists, and dental industry professionals toward dental prosthesis ordering and associated platform services (a total of 53 respondents). The questionnaire was devised after an expert review and assessed for reliability using Cronbach's alpha coefficient. Factor analysis revealed that 57 factors across five categories accounted for 88.417% of the total variance. The survey was administered through an online questionnaire platform, and data analysis was conducted using a statistical software, employing one-way analysis of variance and Tukey's honestly significant difference test (α = 0.05). Results: The essential elements identified were accurate information input, effective communication, delivery of distortion-free impressions, convenience in data transmission and storage, development of stable and affordable platform services (P < 0.05). Furthermore, significant differences were observed in the importance of these items based on age, dental profession, and career experience (P < 0.05). Conclusion: The dental prosthesis ordering platform services, the requirements of dental personnel were stability, economic efficiency, and ease of transmitting and storing prosthesis data. The findings can serve as important indicators for the development and improvement of dental prosthesis order platform services.

Shade taking & team work (색조 선택과 팀워크)

  • Lim, Youngbin
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.22 no.1
    • /
    • pp.67-73
    • /
    • 2013
  • The word 'aesthetic', one of three functions of the teeth - mastication, pronunciation, and aesthetic - does not simply mean beauty. Aesthetic missing harmony cannot be called aesthetic. It is true aesthetic when the harmony with surrounding teeth and environment such as lips, midline, and facial form is achieved. In order to produce a harmonious prosthesis, sufficient information must be passed on to a technician, and also the technician should request necessary information to the dental office. Good food cannot be made without fresh ingredients. Although fresh ingredients are supplied, delicious food is also not possible without a chef's cooking skills. The first-class dish is made only under the circumstances that a skilled chef can do his best with fresh ingredients. In this study, the teamwork to be shared between dental practitioners and technicians for harmonious aesthetic prosthesis is discussed.

Evaluation of Validity of Edentulous Digital Model for Complete Denture Fabrication (총의치 제작을 위한 무치악 디지털 모형의 정확도 평가)

  • Kim, Won-Soo;Kim, Ki-Baek
    • Journal of dental hygiene science
    • /
    • v.15 no.4
    • /
    • pp.393-398
    • /
    • 2015
  • One of the most critical causes in determining the clinical outcomes of dental prostheses is the validity of models. However, studies that evaluated validity of digital models are few. The objectives of this study were to evaluate validity of edentulous digital models for full denture fabrication. Twenty stone models (edentulous model) were manufactured and scanned by dental blue light emitting diode scanner. Twenty digital models were manufactured. Six linear distances (inter-canine distance, inter-molar distance, two dental arch lengths (right, left), two diagonal of dental arch lengths (right, left) were measured for validity evaluation. The measurements of distances of stone models were used by digital vernier caliper and digital models were used by computer program. The mean${\pm}$deviations values of six distances were calculated. The means were compared by the Mann Whitney U test (${\alpha}=0.05$). All statistical analysis were performed using IBM SPSS Statistics ver. 20.0. Although digital models were smaller than stone models in six distances, there were no significant differences (p>0.05) and non exceeded the clinical acceptable range. The edentulous digital models for full denture fabrication can be considered clinically acceptable.

Comparison Analysis of a Cost Price for Dental Prosthetic Restoration (치과기공물 원가계산의 비교분석)

  • Park, Myoung-Ho;Lee, Sang-Rak
    • Journal of Technologic Dentistry
    • /
    • v.22 no.1
    • /
    • pp.153-178
    • /
    • 2000
  • Dental prosthetic restoration shows a big difference of cost per itemized unit depending on the size of dental labs, facility standard, manpower, and performance. Even the same dental labs have distinctive cost according to manufacturing performance, inflation, and the number of workers. However, in apite of such a change of circumstances, it appears to be quite stable in the relative cost per itemized unit unless the manufacturing trend of particular item changes dramatically. Therefore, if the relative number of cost per itemized unit, which is produced by costing, is indicated, we are able to utilize it effectively as a standard wage estimate. If the wage of dental prosthetic restoration is determined on the basis of cost, it is desirable that the relative value of cost and that of wage are identical. But, by means of comparative analysis, since the relative value of wage reveals mostly lower than that of cost depending on an item, it is considered that the wage is not reflecting the cost approproately. Due to the subdivision and the profession of medical technology, the new development of wage items for dental prosthetic restoration is required. This means that the need for the establishment of new wage items should be presented as the general concept of dental prothetic restroation changes and the level of pathologic technology increases. The current wage structure has differences in the degree of difficulty accroding to unit items and in the cost factors. Nevertheless, the differences are not reflected enough to the wage, so there is potential to lower the medical quality through the use of low-proce materials to avoid the increase of cost and the work process which skips a manufacturing step. The new items of dental prosthetic restoration also increases, but the development of proper numerical value system is not supported. Thus, the right proce is set mostly by applying to the wage of a similar item. Since most wages are established by an individual agreement between the dental clinic institute and the dental labs, the propriety of wage level lacks. Therefore, it is urgent to provide and promote the system of a fair work charge by a standard cost which can be applied to all medical institute.

  • PDF

An Empirical Study on the Cost Finding of Dental Laboratory Products in a University Hospital (치과기공물(齒科技工物) 원가계산(原價計算)에 관(關)한 실증적(實證的) 연구(硏究))

  • Paek, Seok-Hyeon
    • Journal of Technologic Dentistry
    • /
    • v.16 no.1
    • /
    • pp.78-104
    • /
    • 1994
  • Under the fee for service schedule of Korean health insurance system, rational fee for dental laboratory products based on the cost is required to be formulated. The purpose of this study was to find actual cost of dental laboratory products in case of a University Hospital. Materials of this study were used as follows : 1. Balance sheet at Dec. 31, 1992 and profit and loss report of the year 1992 of the sample hospital 2. Performance report of dental laboratory department. 3. Purchasing and other accounting bills of dental laboratory materials. The following methods were used. 1. Actual cost finding of dental laboratory department was performed. 2. Work sampling methods were used for measuring standard working time by the process of working. 3. To porcelain fused to metal crown(non-precious), Relative value of the cost of dental laboratory products was calculated as 1.00. 4. Fee and cost of those products were compared on the basis of Relative values. The results of the study can be summarized as follow : 1. Overall, it took longs time than other items. to product denture-related items. 2. When several teeth are made in a time, average production time is much sorter than when one tooth is made in a time. 3. The relative price cost of Dicor cast crown and denture related items are higher than the criterion items. 4. The material cost occupies average 11% out of the total price cost, proportion of personnel expenses is average as 60.0%. 5. Some of the components consisting of the price cost are not reflected adequately in setting the level of the reimbursement price. 6. Relative values of dental laboratory products price cost are varied in the range from 0.05 to 2.83, overall, the reimbursement price of dental products appears not to reflect adequately the price cost. On the basis of this study results, the following ideas would be suggested : 1. Fee Schedule of dental laboratory products should be renovated in order to reflect their costs. 2. Dental laboratory product manufacturers should be enlarged for the economy of scale which may be useful for cost- containment. 3. Dental laboratory producters themselves are required to be standardiqed according to the categories of skill.

  • PDF