• Title/Summary/Keyword: 측 방향 거동

Search Result 41, Processing Time 0.02 seconds

Numerical Analysis for Separation of Carbon Dioxide by Hollow Fiber Membrane with Cocurrent Flow (병류흐름의 중공사 분리막에 의한 이산화탄소 분리 수치 해석)

  • Lee Yong-Taek;Song In-Ho;Ahn Hyo-Seong;Lee Young-Jin;Jeon Hyun-Soo;Kim Jeong-Hoon;Lee Soo-Bok
    • Membrane Journal
    • /
    • v.16 no.3
    • /
    • pp.204-212
    • /
    • 2006
  • A numerical analysis was carried out for separation of carbon dioxide from carbon dioxide/nitrogen gas mixture by a polyethersulfone hollow fiber membrane which has shown a good stability against plasticization by carbon dioxide and an excellent separation efficiency fur carbon dioxide from its gas mixture. A computer program for carbon dioxide separation was developed using the Compaq Visual Fortran 6.6 software. Governing module equations were thought to be an initial-value problem and the nonlinear ordinary differential equations were simultaneously solved using the Runge-Kutta-Verner fifth-order method. From results of numerical analysis, the carbon dioxide partial pressure of the feed stream, the pressure ratio of the feed side to the permeate side and the feed gas residence time at the inside of a membrane were found to be very important factors to affect the permeation characteristics of carbon dioxide.

Nonlinear Analysis of RC Bridge Columns for Ductility Evaluation (철근콘크리트 교각의 연성도 평가를 위한 비선형해석)

  • 손혁수;이재훈
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.7 no.4
    • /
    • pp.39-49
    • /
    • 2003
  • This research is a part of a research program to develope a new design method for reinforced concrete bridge columns under axial load and cyclic lateral load. A nonlinear analytical method is proposed to obtain moment-curvature relationship and lateral load-displacement relationship. Various analytical models that contribute seismic behavior of reinforced concrete bridge columns are adopted and modified by comparing quasi-static test results of reinforced concrete columns with spirals of circular hoops. The analysis adopts confined concrete model, longitudinal reinforcement test result of reinforced concrete columns with spirals or circular hoops. The analysis adopts confined concrete model, etc. The results obtained using the propose analytical method agree well with test results and give conservative estimations particularly for deformation capacity and ductility.

Lap Details Using Headed Bars and Hooked Bars for Flexural Members with Different Depths (확대머리 철근과 갈고리 철근을 이용한 단차가 있는 휨부재의 겹침이음상세)

  • Lee, Kyu-Seon;Jin, Se-Hoon;Kim, Seung-Hun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.20 no.4
    • /
    • pp.144-152
    • /
    • 2016
  • This paper focuses on the experimental study for investigating the performance for lap splice of hooked or headed reinforcement in beam with different depths. In the experiment, seven specimens, with its variables as the lap length of headed or hooked bar, the existence of stirrups, etc., was manufactured. Bending test was conducted. Lap strengths by test were compared with the theoretical model based on KCI2012. The result showed that the cracks at failure mode occurred along the axial direction to a headed bar. The initial stiffness and the stiffness after initial crack were similar for all specimens. For HS series specimens without stirrups, a 25% increase in lap length was increased 11.8~18.1% maximum strengths. For HH series specimens without stirrups, a increase in lap length did not affect the maximum strengths because of the pryout failure of headed bar. For HS series specimens, the theoretical lap strengths based on KCI2012 considering the B grade lap and the reduction factor for stirrup were evaluated. They are smaller than the test strengths and can ensure the safety in terms of strength capacity. For HH series specimens, the stirrups in the lap zone are needed to prevent the pryout behaviour of headed bar.

Evaluation on the Horizontal Shear Strength of Precast Concrete Slab with the Inverted-Rib-Plus (리브플러스 PC슬래브의 수평전단강도 평가)

  • Park, Keum Sung;Lee, Sang Sup;Choi, Yun Cheul
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.15 no.6
    • /
    • pp.156-165
    • /
    • 2011
  • This study investigates the horizontal shear behavior of an interface between precast concrete (PC) and topping concrete(RC), and evaluates the horizontal based on the investigations by the experimental. Horizontal shear strength in connected surface is determined by the roughness an interface and the shear reinforcement or not. In this study, the main experimental parameters are the shear reinforcement types in the shape of loop-type and lattice-type, rebar spacing. A total of four specimens were shear strength tested and manufactured. As a result, the horizontal shear strength of reinforced connected surface was found to be controlled by deformation in vertical direction. Comparison of reinforcement shape, the mean initial crack load loop type specimens, the average maximum load and the junction of the average in terms of initial stiffness, respectively 33.7%, 45.9% and 55.2% were large enough. Evaluation results for shear strength equation of existing standard domestic, the loop-type reinforced 2.32 to 4.23 times, lattice-type reinforced 1.65 to 3.06 times appears to be higher. Behavior of interface or strength of structural design criteria was fairly safe side. It does not have any problems in the applied field is considered.

Study on Heat and Smoke Behavior Due to the Natural Wind and the Forced Smoke Ventilation for the Fire in an Underground Subway Station (지하역사에서 화재발생시 자연풍 및 강제배연의 유무에 따른 열 및 연기거동 특성 연구)

  • Chang Hee-Chul;Kim Tae-Kuk;Park Won-Hee;Kim Dong-Hyeon
    • Fire Science and Engineering
    • /
    • v.19 no.1 s.57
    • /
    • pp.80-86
    • /
    • 2005
  • In this study effects of the natural wind and the forced smoke ejection by operating the exhaust fan are studied numerically to examine the flow characteristics of the smoke and heat generated from a fire on the platform of an underground subway station. Three different situations, including 1) the case with no natural wind and no exhaust fan operation, 2) the case with natural wind but no exhaust fan operation and 3) the case with no natural wind but exhaust fan operation, are considered for the numerical analyses. The numerical results show that the natural wind causes a rapid spread of the fire along the tunnel resulting in rapid spread of the smoke and heat over the platform which affects the escape. The operation of the exhaust fan also results in the rapid spread of smoke and heat over the platform, but the time required for reaching the safe escaping height of the smoke layer with the exhaust fan operation is much longer than that without the exhaust fan operation. The numerical results also show that the required capacity of the exhaust fan becomes larger when the effect of the natural wind is included.

Case Study about the Ground Characteristics Analysis of Tunnel Face Fault Fractured Zone (터널막장 단층파쇄대의 지반특성 분석에 대한 사례연구)

  • Min Kyoung-Nam;Lim Kwang-Su;Jang Chang-Sik;Lim Dae-Hwan
    • Tunnel and Underground Space
    • /
    • v.15 no.2 s.55
    • /
    • pp.111-118
    • /
    • 2005
  • The area of investigation belongs to Okchon metamorphic zone and the fault fractured zone runs parallel to the tunnel direction. It causes the independent decline of tunnel face and the slackness of the tunnel surrounding base so, after all, the severe displacement has occurred within the tunnel. Accordingly, the TSP(Tunnel Seismic Prediction) survey has been performed to investigate the extent of fault fractured zone and to analize its characteristics. Also, we have analized the behavior causes by performing the tunnel face mapping and drilling investigation, and confirmed the position and scale of geological anomaly area and front fractured zone which influences tunnel excavation and supporting. Collected data analyzed ground layer condition through 3 dimensional modeling. Several variables included in the modeling were analyzed by geostastistics. The analysis of the modeling data shows that the belt of weathering by fault fractured zone is developing on the basis of the right side of tunnel and that is decreasing to the left side. The fault fractured zone was confirmed that it has strike, $N0\~5^{\circ}E$ dip NW, and it is consisted of large-scale fractured zone including several anomalies. The severe displacement in tunnel is probably caused by asymmetrical load that n generated by the crossing of discontinuity and the rock strength imbalance of tunnel's both side by fault fractured zone, and judge that need tunnel reinforcement method of grouting etc.

Effect of temperature and moisture on curling of early age concrete slabs (재령 초기 콘크리트 슬래브의 컬링에 미치는 온도와 수분의 영향)

  • Sun, Ren-Juan;Nam, Young-Kug;Hong, Seung-Ho;Jeong, Jin-Hoon
    • International Journal of Highway Engineering
    • /
    • v.10 no.1
    • /
    • pp.105-115
    • /
    • 2008
  • It is known that the long-term behavior and performance of jointed concrete pavement due to slab curling are affected by the environmental factors such as temperature, moisture, and so on. However, any relationships between the curling and its factors have not been defined clearly yet because of insufficient detailed investigation. The temperature, relative humidity, strain, vertical displacement of a concrete slab, and horizontal movement of its transverse joints were investigated by various sensors and devices instrumented in the slab of a concrete pavement section constructed for this study. The constraint of the curling by joint stiffness was investigated in addition to effect of the temperature and moisture on the early aged concrete slab by analyzing the field data measured for approximately 4days from concrete placement. The curling of the concrete slab showed 24hour cycles mainly because of the temperature effect, and the upward curling gradually increased because of the long-term effect of drying shrinkage of the concrete. The magnitude and variation of the curling were significantly affected by the joint stiffness which is comprised of aggregate interlocking and other factors. The effect of the variation of the seasonal joint stiffness varying with the temperature and long-term drying shrinkage on the slab curling will be investigated as a further study.

  • PDF

Simulation of mixing process and influence zone of the fresh water for the inner Saemankeum reservoir and outer region regarding seawater bypassing (해수소통이 전제된 새만금호 내부의 혼합확산거동과 외해역의 영향범위 모의)

  • Suh Seung Won;Mok In Kyun;Kim Jun Ho;Yu Kyung Sun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2005.05b
    • /
    • pp.543-547
    • /
    • 2005
  • 해수소통을 전제한 경우 새만금호 내측의 염분변화가 만경강의 평수량 및 홍수량 유입에 따라 혼합확산되는 것을 평가하고 배수갑문 방류시 담수가 외해에 미치는 영향범위를 평가하기 위한 수치모형실험이 실시되었다. 이때 새만금호 내부의 관리수위는 DL=-1.5m, DL=-0.5m, DL=-0.0m, DL=+0.5m가 고려되었다. 외해역의 평가는 새만금을 포함한 전체해역에 대해 외해경계에서 4개의 주요분조($M_2,S_2,K_1,O_1$)의 진폭과 위상각을 대입하고 2차원 ADCIRC 및 3차원 TIDE3D 모형을 적용하였다. 내부는 여기에 3개 연직층을 고려한 3차원 ICM 모델이 추가 적용되었다. 내부의 혼합확산 평가 결과는 시간이 지남에 따라 외해에서 유입되는 염수가 상대적으로 저염인 담수호 내부로 유입 확산되는 것이 평면적으로나 연직방향으로 변화되는 것을 매우 뚜렷하게 나타남을 알 수 있고, 최소 1개월 이상 경과되어야 만경호측에 외해수가 혼합되는 것으로 분석된다. 수문을 개방하지 않은 상태에서 새만금 방조제 외해의 최강창낙조시 조류속도는 0.5-0.6m/s 정도에 해당되는 것으로 분석되었다. 신시갑문을 개방하는 경우 관리수위가 DL=-1.5m와 DL=+0.5m로 변함에 따라 갑문 전면 10Km-l3Km에 이르는 해역까지 수문개방에 따라 0.5m/s의 유속이 형성된다. 가력갑문을 개방하는 경우는 신시갑문의 개방에 따른 영향보다는 작지만 갑문 전면 14Km까지 0.5m/s의 강한 유동이 관리수위별로 나타나고 있다. 이러한 결과는 담수 방류로 인한 영향이 주기적으로 낙조시에 발생되어 새만금 방조제 전면의 해수순환과 유동에 적지 않은 영향을 미칠 개연성을 제시하는 것으로 해석된다.$\cdot$유출에 의한 수질변화양상을 단계적으로 구분하여 수질변화에 중요한 영향을 미치는 인자에 대한 이론적인 분석을 수행하고, 배수갑문 개방에 의한 수질개선효과를 최대화하기 위한 환경관리 방안 제시에 중점을 두어 수행하였다.ncy), 환경성(environmental feasibility) 등을 정성적으로(qualitatively) 파악하여 실현가능한 대안을 선정하였다. 이렇게 선정된 대안들은 중유역별로 검토하여 효과가 있을 것으로 판단되는 대안들을 제시하는 예비타당성(Prefeasibility) 계획을 수립하였다. 이렇게 제시된 계획은 향후 과학적인 분석(세부평가방법)을 통해 대안을 평가하고 구체적인 타당성(feasibility) 계획을 수립하는데 토대가 될 것이다.{0.11R(mm)}(r^2=0.69)$로 나타났다. 이는 토양의 투수특성에 따라 강우량 증가에 비례하여 점증하는 침투수와 구분되는 현상이었다. 경사와 토양이 같은 조건에서 나지의 경우 역시 $Ro_{B10}(mm)=20.3e^{0.08R(mm)(r^2=0.84)$로 지수적으로 증가하는 경향을 나타내었다. 유거수량은 토성별로 양토를 1.0으로 기준할 때 사양토가 0.86으로 가장 작았고, 식양토 1.09, 식토 1.15로 평가되어 침투수에 비해 토성별 차이가 크게 나타났다. 이는 토성이 세립질일 수록 유거수의 저항이 작기 때문으로 생각된다. 경사에 따라서는 경사도가 증가할수록 증가하였으며 $10\% 경사일 때를 기준으로 $Ro(mm)=Ro_{10}{\times}0.797{\times}e^{-0.021s(\%)}$로 나타났다.천성 승모판 폐쇄 부전등을 초래하는 심

  • PDF

Calculation of the Earthquake Vulnerability of the Bridge Foundation Considering the Characteristics of the Ground (지반의 특성을 고려한 교량기초의 지진취약도 산정)

  • Lee, Donggun;Song, Kiil
    • Journal of the Korean GEO-environmental Society
    • /
    • v.23 no.2
    • /
    • pp.13-23
    • /
    • 2022
  • The ground-structure interaction of the bridge foundation has been pointed out as a major factor influencing the behavior of the bridge during earthquakes. In this study, the effect of characteristics of ground and bridge foundation on the earthquake vulnerability is investigated. From the pseudo-static analysis, it is confirmed that non-linearity becomes lesser and horizontal load becomes greater when surcharge is considered. It is also found that as the ground worsens and the size of foundation decreases, horizontal load reduces. To derive reasonable structural model for bridge foundation, fragility curve is obtained considering four conditions (fixed condition, equivalent linear condition, non-linear without surchage condition, non-linear with surcharge condition) and compared. Seismic analysis is performed on single pier with Opensees. From the earthquake vulnerability analysis, it is found that shallow foundation can be assumed as fixed condition. In conservative approach, stiffness of spring can be obtained based on Korean highway bridge design code for pile foundation which can consider the ground condition.

Dynamic Behavior of Model Set Net in the Flow (모형 정치망의 흐름에 대한 거동)

  • Jung, Gi-Cheul;Kwon, Byeong-Guk;Le, Ju-Hee
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.33 no.4
    • /
    • pp.275-284
    • /
    • 1997
  • This experiment was carried out to measure the sinking depth of each buoy, the change in the net shape of the net, and the tension of sand bag line according to the R (from bag net to the fish court) and L (from fish court to the bag net) current directions and their velocity by the model experiment. The model net was one-fiftieth of the real net, and its size was determined after considering the Tauti’s Similarity Law and the dimension of the experimental tank. 1. The changes of the net shape were as follows : In the current R, the end net of fish court moved 20mm down the lowerward tide and 10mm upper part. So the whole model net moved up at 0.2m/sec. The shape of the net showed an almost linear state from bag net to the fish court at 0.6m/sec. In the current L, the door net moved 242mm down the lowerward tide and 18mm upper part. So the whole model net moved up at 0.2m/sec. The net shape showed an almost linear state from the fish court to the bag net at 0.5m/sec. 2. The sinking depths of each buoy were as follows: In the current R, the head buoy started sinking at 0.2m/sec and sank 20mm, 99mm at 0.3m/sec and 0.6m/sec, respectively. The end buoy didn't sink from 0m/sec to 0.6m/sec but showed a slight quake. In the current L, the end buoy started sinking at 0.1m/sec, and sank 5mm and 108mm at 0.2m/sec and 0.6m/sec, respectively. The whole model net sank at 0.5m/sec except the head buoy. 3. The changes of the sand bag line tension were as follows: In the current R, the tension affected by the sand bag line of the head buoy showed 273.51g at 0.1m/sec increased to 1298.40g at 0.6m/sec. In the current L, the tension affected by the sand bag line of the end buoy on one side showed 137.08g at 0.1m/sec increased to 646.00g at 0.6m/sec. The changes in the sand bag line tension were concentrated on the sand bag line of the upperward tide with increasing velocity at the R and L current directions. However, no significant increase in tension was observed in the other sand bag lines.

  • PDF