• Title/Summary/Keyword: 측정허용기준

Search Result 302, Processing Time 0.032 seconds

Field Survey on the Construction Errors for the Members of Reinforced Concrete Structures (현장조사를 통한 철근콘크리트 구조 부재의 시공오차에 관한 연구)

  • Yoon, Sang-Chun;Jee, Nam-Yong;Choi, Ki-Bong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.14 no.3
    • /
    • pp.201-208
    • /
    • 2010
  • Information on the distribution characteristics of construction errors is very important to determine the member factors, which are to be introduced in a new Korean design code for reinforced concrete structures. The new design code, which is under development for reinforced concrete structures, is based on the performance design concept. The construction errors of reinforced concrete members are mainly caused by the firmness and dimensional accuracy of forms, the arranging condition of reinforcing bars, the pouring and compaction methods of concrete, the skills of field workers, and the experience of supervisors. To find out the construction errors of reinforced concrete structures already built in Korea, a field survey for cover thickness, effective depth of reinforcement, the thickness of slabs and walls, and the dimension of beams and columns has been performed. Based on the survey, which is the first time in Korea, the analysis results are presented. The measuring methods for the construction errors, which have been established through the laboratory tests, are also presented. In addition, the measured construction errors from the survey are compared with the allowable tolerances in the current domestic and foreign specifications.

Development of Verification Method for ADCP (ADCP 유량 측정기기의 검정 방안 개발)

  • Noel Kang;Chi Young Kim;Kyung Min Kang;Yo Han Cho;Chang-Hwan Kim
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.305-305
    • /
    • 2023
  • 수문조사기기 검정은 강수량, 수위, 유량 등과 같은 수문자료를 관측하는 수문조사기기가 대상지역의 수문상황을 정확하게 관측하는지를 검사하는 일련의 과정으로 「수자원의 조사 계획 및 관리에 관한 법률」 제12조에 법적 기반을 두고 있다. 검정 대상은 강수량, 수위, 유속, 유사량, 토양수분량, 증발산량, 증발량 측정기기 총 7종이며, 환경부장관으로부터 한강홍수통제소가 검정업무를 위임받고, 한국건설기술연구원과 한국수자원조사기술원이 위탁받아 운영중에 있다. 최근에는 증발산량, 토양수분량 및 유량 측정기기기 등이 첨단화되어 기존 검정 방식에 대한보완 및 신설에 대한 요구가 증가하고 있다. 특히, 유량 측정시 기존에 사용하였던 회전식 유속계는 ADCP(Acoustic Doppler Current Profiler) 유량측정기기로 대체되어 활용률이 2013년 24%에서2021년 67%로 약 2.8배 급격히 증가하였다. 하지만 수문조사기기 검정 관련 고시 내 ADCP에 대한검사방법 및 허용오차 등의 규정이 부재하여 수문조사기기의 검정 공백이 발생하는 등의 문제가 존재하고 있다. 이에 본 연구에서는 ADCP 운영 및 기술 현황, 현행 법령, 국외 사례 등을 검토하여 ADCP 유량측정기기의 검사방법 및 허용오차에 대한 방안을 제시하고자 한다. ADCP 검사방법은 총 5단계로 외관검사, 자가진단 검사, 온도센서 검사, 수심측정 검사, 유량비교측정 검사에 따라 검정을 실시한다. 첫 번째 외관검사시에는 기기 외관과 센서 등 물리적 손상을 점검하고, 두 번째 자가진단 검사에서는 센서 변환 매트릭스 값, 수신부 센서 테스트, RAM/ROM 테스트, 통신 테스트 등에 관한 정상값 산출 여부를 확인한다. 세 번째 온도센서 검사에서는 검증용 온도센서를 이용한 값과 ADCP에 부착된 온도센서 값과 차이를 확인하고 ±2℃초과시 재검사 또는 적절한 조치를 취한 후 다음 단계의 검사를 진행한다. 네 번째 수심측정 검사에서는 수조 내 수심 측정을 확인하여 실제 수심과의 오차를 확인하고 ±1% 초과시 재검사 또는 적절한 조치 후 다음 검사를 실시한다. 유량비교 측정검사에서는 각 기기 간의 평균유량의 상대오차를 평가하는 것으로 ±5%미만에는 합격, ±5이상 ±10%미만에서는 재검사, ±10%이상에서는 공장수리를 권고하도록 하고, 1~5 단계의 검사를 통과한 기기를 대상으로 인증서를 발급하도록 한다. 유량비교 측정검사시에는 매년 ADCP를 사용하는 일반기업 및 공공기관 등이 모여 ADCP의 성능을 상호간 비교하는 'ADCP 기술협력 워크숍'을 확장하여 실시할 수 있다. 각 검사 단계의 허용오차는 USGS 또는 제조사 기준과 2022년 ADCP 기술협력 워크숍 성능검사 분석 결과를 토대로 하였다. 본 ADCP 검정 방안은 향후 ADCP 모델별로 단계별 시범 검토를 통해 세부사항에 대한 제시가 필요하며, 온도센서 검사, 수심측정 검사, 유량 비교측정검사에 대한 허용오차에 대한 타당성에대한 검증 및 검토가 이루어져야 할 것으로 사료된다.

  • PDF

Establishment schemes for an Inspection system of hydrological survey instruments (수문조사기기의 검정 체계의 확립방안)

  • Jang, Bok-Jin;Jung, Sung-Won;Park, Sung-Sik;Lee, Sin-Jae
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2009.05a
    • /
    • pp.347-353
    • /
    • 2009
  • 수문조사기기의 검정은 수문조사에 활용하거나 활용하고자 할 다양한 수문조사기기를 일관되고 표준화된 기준으로 검사하여 수문조사에 적합한 기기를 설치하거나 지속적으로 사용하도록 하고자 하는 것이다. 이러한 검정은 국가수문자료의 신뢰도를 높이고 유지하고자 하는 기본적이고 중요한 업무이다. 국내에서는 2009년 2월 현재 회전식 유속측정기기와 일부 강수량측정기기만을 검정하고 수문조사에 활용하고 있는 실정이다. 따라서 수문자료의 신뢰도에 대해 제시할 수 있는 지표는 유량측정결과의 불확도와 일부 강수량계를 제외하고 사실상 없다고 할 수 있다. 그 밖의 수문조사기기들에 의해 생산된 수문자료는 단지 제조사에서 제공하고 있는 정확도와 정밀도 등의 정보를 통해서 가늠하고 있어 국가수문자료로서의 신뢰성으로 제시하기에는 부족하다고 할 수 있다. 수문조사기기의 검정시행을 위해서는 각 기기에 대하여 검정방법, 허용오차, 검정기관의 조건 및 기타 행정적 체계 등이 필요하다. 본 연구에서는 국내에서 사용되고 있는 수문조사기기의 현황을 파악하고 대상기기를 선별할 수 있도록 하였다. 그리고 각 대상 수문조사기기에 대한 검사방법과 허용오차를 규정하기 위해 공통적으로 필요한 과정과 방법론을 제시하여 객관적으로 신뢰할 수 있으며 효율적으로 적용 가능한 검사방법과 허용오차를 결정할 수 있도록 하였다. 또한 공신력 있는 검정 결과를 보장하기 위해 검정기관에서 갖추어야 할 인력, 설비 및 품질 시스템 등이 국제표준(ISO)에 부합되면서도 수문조사분야에 효율적으로 적용될 수 있는 조건들에 대해 분석 제안하였다. 본 연구결과는 국가차원에서 신뢰할 수 있는 공인검정기관이 수문조사기기 검정을 시행할 수 있게 하는 초석이 될 것이며, 수문조사기기의 검정이 시행되면 이후 생산되는 수문자료는 정해진 검사방법과 허용오차 이내의 품질을 공인검정기관이 인정하는 수문자료로서의 신뢰도를 확보하게 될 것으로 기대된다.

  • PDF

A Study on Computer-Aided Consulting System for Vehicles Impact Test and Human Body Injury Criteria (차량 충돌 시험 및 인체 상해 기준 지원 시스템 연구)

  • Kim Young-Ki;Huh Yong-Jeong
    • Proceedings of the KAIS Fall Conference
    • /
    • 2005.05a
    • /
    • pp.48-50
    • /
    • 2005
  • 본 연구에서는 차량 충돌 시험시 결과에 관하여 측정하는 방법 중 인체 상해 기준에 따른 평가를 지원해주기 위한 시스템에 관한 것이다. 차량 충돌시험의 가장 큰 분류인 정면 충돌과 측면충돌 2가지에 대찬 내용을 기준으로 인체 모형 각 부분의 결과 값에 따른 기준과 계산 방법 및 법규 규정을 제시하여 준다. 이러한 시스템은 인체 모형의 구성과 차량 충돌 시험시 중요시하는 인체 부분에 대한 이해를 돕는다 실제 인간의 대신한 인체 모형의 이해는 실제 인간이 승차하고 있는 차량의 안전도의 이해를 돕는다. 본 연구에서는 차량 충돌 시험 평가와 인체 상해 기준에 대해 차량충돌 안전부문 관련자들에게 온라인으로 이용할 수 있는 정보지원시스템에 대하여 기술하였다.

  • PDF

Effects of Movement When Using Visual Media to Determine Encounter Standards1a (휴양지역의 조우 평가기준 설정을 위한 시각매체의 활용시 움직임의 효과)

  • Kim, Sang-Oh;Shelby, Bo
    • Korean Journal of Environment and Ecology
    • /
    • v.23 no.4
    • /
    • pp.309-316
    • /
    • 2009
  • The usefulness of media representations for assessing normative standards depends in part on how accurately media reflect "on-the-ground" resource conditions. This study compared encounter standards based on still and moving pictures to assess movement effects. The study location was the Jungmoeri area of Mudeungsan Provincial Park (MPP) in Korea. A total of 50 college students participated in a laboratory experiment where they evaluated still and moving pictures constructed using Photoshop and Flash computer programs. For the maximum acceptable number (MAN), however, there was no significant difference of ratings between still and moving pictures, and the overall encounter norm curves were nearly identical. There were some "method findings" for ordering effects and percent of people moving, but for a resource manager developing standards there was no advantage to the more complex logistics of using moving pictures to assess this particular impact. The trade-offs of using more sophisticated media are discussed, and more research is needed to further explore factors such as movement of sound in evaluation of other resource conditions.

Design Comparison of Composite Girder Bridges Designed by ASD and LRFD Methods (허용응력설계법 및 하중저항계수설계법에 의한 강합성 거더교 설계결과 비교)

  • Cho, Eun-Young;Shin, Dong-Ku
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.5A
    • /
    • pp.447-456
    • /
    • 2009
  • The design comparison and flexural reliability analysis of continuous span composite plate girder bridges are performed. The girders are designed by the methods of allowable stress design (ASD) and load and resistance factor design (LRFD). For the LRFD design, the design specification under development mainly by KBRC, based on AASHTO-LRFD specification in case of steel structures, is applied with the newly proposed design live load which has been developed by analyzing domestic traffic statistics from highways and local roads. For the ASD based design, the current KHBDC code with DB-24 and DL-24 live loads is used. The longest span length for the 3-span continuous bridges with span arrangement ratio of 4:5:4 is assumed to be from 30 m to 80 m. The amount of steel, performance ratios, and governing design factors for the sections designed by the ASD and LRFD methods are compared. In the reliability analysis for the flexural failure of the sections designed by two methods, the statistical properties on flexural resistance based on the yield strength statistics for over 16,000 domestic structural steel samples are applied.

Quality Assurance of Volumetric Modulated Arc Therapy Using the Dynalog Files (다이나로그 파일을 이용한 부피세기조절회전치료의 정도관리)

  • Kang, Dong-Jin;Jung, Jae-Yong;Shin, Young-Joo;Min, Jung-Whan;Kim, Yon-Lae;Yang, Hyung-jin
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.577-585
    • /
    • 2016
  • The purpose of this study is to evaluate the accuracy of beam delivery QA software using the MLC dynalog file, about the VMAT plan with AAPM TG-119 protocol. The Clinac iX with a built-in 120 MLC was used to acquire the MLC dynalog file be imported in MobiusFx(MFX). To establish VMAT plan, Oncentra RTP system was used target and organ structures were contoured in Im'RT phantom. For evaluation of dose distribution was evaluated by using gamma index, and the point dose was evaluated by using the CC13 ion chamber in Im'RT phantom. For the evaluation of point dose, the mean of relative error between measured and calculated value was $1.41{\pm}0.92%$(Target) and $0.89{\pm}0.86%$(OAR), the confidence limit were 3.21(96.79%, Target) and 2.58(97.42%, OAR). For the evaluation of dose distribution, in case of $Delta^{4PT}$, the average percentage of passing rate were $99.78{\pm}0.2%$(3%/3 mm), $96.86{\pm}1.76%$(2%/2 mm). In case of MFX, the average percentage of passing rate were $99.90{\pm}0.14%$(3%/3 mm), $97.98{\pm}1.97%$(2%/2 mm), the confidence limits(CL) were in case of $Delta^{4PT}$ 0.62(99.38%, 3%/3 mm), 6.6(93.4%, 2%/2 mm), in case of MFX, 0.38(99.62%, 3%/3 mm), 5.88(94.12%, 2%/2 mm). In this study, we performed VMAT QA method using dynamic MLC log file compare to binary diode array chamber. All analyzed results were satisfied with acceptance criteria based on TG-119 protocol.

Customer Acceptance Procedure for Clinac (21EX-Platinum)

  • Hong, Dong-Ki;Lee, Woo-Seok;Kwon, Kyung-Tae;Park, Kwang-Ho;Kim, Chung-Man
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.16 no.2
    • /
    • pp.43-61
    • /
    • 2004
  • Purpose : For qualify improvement in radiotherapy, it is important to set up and evaluate equipment (linac) accurately. In addition, technicians are needed to be fully aware of the equipment's detailed quality and its manual. Therefore, the result of ATP is evaluated and introduced, in order that the technicians are skilled by participating in quality assurance (QA) and understanding the quality of the equipment before clinical use. Method and Material : QA for LINAC 21EX (Varian, US) was done with suppliers its procedure was divided into radiation survey, mechanical test, radiation isocenter test, bean performance, dosimetry, and enhanced dynamic wedge and using X-omat film (Kodak), multidata, densitometer, and electrometer. QA of MLC (Millennium, 120 leaf) attached to LINAC and EPID (Portal vision) were done separately. Result : The leakage dose by survey meter was below the tolerance. In mechanical test, collimater, gantry, and couch rotation were less than 1mm, and the angles were ${\pm}0.1^{\circ}$ for digital and ${\pm}0.5^{\circ}$ for mechanical. The alignment test of the light field and crosshair were evaluated less than 1mm. The (a)symmetrical jaw field was less than ${\pm}0.5mm$. The radiation isocenter test using X-mat film was less than 1mm. The consistency of light field and radiation field was less than ${\pm}0.1mm$. PDD for photon energy was less than ${\pm}1\%$ and for electron energy of $90\%,\;80\%,\;50\%,\;and\;30\%$ were evaluated within the tolerance. Flatness for photon and electron energy was evaluated $2.3\%$ (tolerance $3\%$) and $3\%$ (tolerance $4.5\%$), respectively, and symmetry was $0.45\%$ (tolerance $2\%$) and $0.3\%$ (tolerance $2\%$), respectively. Dosimetry test for short term, MU setting, rep rate, and dose rate accuracy of photon and electron energy was within the tolerance depending on energy, MU, and gantry angle. Conclusion : Accuracy and safety for clinical use of Clinac 21EX was verified through customer acceptance procedure and the quality of the equipment was found out. These can reduce the difficulties in using the equipment. Furthermore, it is useful for clinically treatment of patients by technicians' active participations.

  • PDF

Analysis of impact of CATV leakage on CDMA Mobile Communication Systems (CDMA 이동통신시스템에 대한 케이블 방송 전송설비 누설전자파 영향 분석)

  • Park, Seong-Gyoon;Han, Chan-Kyu
    • Journal of IKEEE
    • /
    • v.15 no.3
    • /
    • pp.218-226
    • /
    • 2011
  • In this paper, the leaky electric field intensity of outdoor CATV facilities on CDMA mobile service band defined in technical regulation related with CATV is investigated if appropriate or not. From experimental and theoretical analysis results, Maximum allowable power level of CATV leakage should be -110dBm/1.23MHz. Also, the CATV leakage intensity thresholds, which may not nearly give an impact on the uplink performance of CDMA mobile base station for outdoor background noise of -100~-80dBm/1.23MHz to be measured in outdoor environment, couldn't conform to the current CATV technical regulation. Therefore, the leakage intensity in the current CATV technical regulation is rated as a too much low level in view of an overly worst case.

Electronic Blasting for Excavating Single Line Railway Tunnel Close to Residential Area (보안물건이 근접한 소단면 철도 단선터널 굴착시 전자발파 시공사례)

  • Lee, Min Su;Kim, Hee Do
    • Explosives and Blasting
    • /
    • v.34 no.3
    • /
    • pp.17-20
    • /
    • 2016
  • This paper introduce a multistage parallel non-vibration electronic tunnel blasting cases which adapts Electronic Blasting System(EBS) and the center-cut blasting method to excavating a single line railway tunnel close to residential area. As a result, it was revealed that the vibration and noise showed a reduction of 23.5% and 75% of compared with the allowable standard. We successfully completed the tunnel excavation with decreasing construction time and construction cost and without civil compliant.