• Title/Summary/Keyword: 측정허용기준

Search Result 302, Processing Time 0.025 seconds

Development and validation of an analytical method for the determination of lepimectin residues by HPLC-PDA (HPLC-PDA를 이용한 lepimectin 잔류량 분석법 개발 및 확인)

  • Do, Jung-Ah;Kwon, Ji-Eun;Kim, Mi-Ra;Lee, Eun-Mi;Kuk, Ju-Hee;Kwon, Kisung;Oh, Jae-Ho
    • Analytical Science and Technology
    • /
    • v.26 no.2
    • /
    • pp.142-153
    • /
    • 2013
  • A new, rapid, and simple analytical method was developed and validated using high performance liquid chromatograph-photodiode array detector (HPLC-PAD) for the determination of lepimectin residues in agricultural commodities. The lepimectin residues in samples were extracted with methanol, partitioned with dichloromethane, and then purified with glass column filled with subsequently to aminopropyl ($NH_2$) solid phase extraction (SPE) cartridge. The purified samples were detected using HPLC-PAD. Correlation coefficient ($R^2$) of both lepimectin $A_3$ and $A_4$ solutions were 0.9999. The method was validated using cucumber spiked with lepimectin at 0.02 and 0.2 mg/kg and pepper, mandarin, hulled rice, potato, soybean at 0.02 and 0.5 mg/kg. Average recoveries were 76.0~114.8% with relative standard deviation less than 10%, and limit of detection (LOD) and limit of quantification (LOQ) were 0.005 and 0.01 mg/kg, respectively. The result of recoveries and overall coefficient of variation of a laboratory results in Gwangju regional KFDA and Daejeon regional KFDA was followed with Codex guideline (CAC/GL 40). Therefore, developed method in this study is accurate, rapid, and appropriate for lepimectin determination and will be used to keep safety of lepimectin residues in agricultural products.

Residue Analysis to Establish an Index for the Safety Use of Propineb (Propineb의 안전사용(安全使用) 기준(基準) 설정(設定)을 위한 잔류분석(殘留分析))

  • Choi, Won-Seog;Yang, Jae-Eui;Han, Dae-Sung
    • Korean Journal of Environmental Agriculture
    • /
    • v.11 no.3
    • /
    • pp.209-214
    • /
    • 1992
  • Residue of Propineb in Sesame(Sesamum indicum L.) seed was determined to establish an index for the safety use of Propineb to Sesame. Evaluation was made on residual concentration of Propineb in Sesame seed as a function of application frequency and date when the mixed formulations of Propineb(56%), protectant fungicide, and Oxadixyl(8%), contact fungicide, were sprayed into Sesame leaves. Level of Propineb treatment was $0.028g/m^2$ with various combinations of application time from three to sixty days before harvest. Results are summarized as followings. 1. Recovery percentages of Propineb from Sesame seed were ranged from 84 to 96, and the minimum detectable limit of Propineb with the method employed in this experiment was 0.03mg/kg. 2. Residues of Propineb in Sesame seed were in the ranges of 0.14 to 1.38mg/kg, varying with frequency and date of Propineb application. 3. Residues of Propineb increased as increasing application frequency of Propineb or as being application date closer to harvest time. 4. Residue of Propineb in Sesame seed was decreased with time, showing to be fitted to the first-order kinetics. 5. Residues of Propineb in Sesame seen were, irresepective of treatments, lower than 2mg/kg, the Maximum Residue Limit(MRL) established by FAO/WHO. 6. Half-life of Propineb determined in this experiment was ranged from 12 to 16 days.

  • PDF

Safety Simulation of Therapeutic I-131 Capsule Using GEANT4 (GEANT4를 이용한 치료용 I-131 캡슐의 안정성 시뮬레이션)

  • Jeong, Yeong-Hwan;Kim, Byung-Cheol;Sim, Cheol-Min;Seo, Han-Kyung;Gwon, Yong-Ju;Han, Dong-Hyun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.2
    • /
    • pp.57-61
    • /
    • 2014
  • Purpose Iodine (I-131) is one of the most widely used radioactive isotopes for therapeutic in the field of nuclear medicine. Therapeutic I-131 capsule is made out of lead to shield high energy radiation. Accurate dosimetry is necessarily required to perform safe and effective work for relative workers. The Monte Carlo method is known as a method to predict the absorbed dose distribution most accurately in radiation therapy and many researchers constantly attempt to apply this method to the dose calculation of radiotherapy recently. This paper aims to calculate distance dependent and activity dependent therapeutic I-131 capsule using GEANT4. Materials and Methods Therapeutic capsules was implemented on the basis of the design drawings. The simulated dose was determined by generating of gamma rays of energy to more than 364 keV. The simulated dose from the capsule at the distance of 10 cm and 100 cm was measured and calculated in the model of water phantom. The simulated dose were separately calculated for each position of each detector. Results According to the domestic regulation on radiation safety, the dose at 10 cm and 100 cm away from the surface of therapeutic I-131 capsule should not exceed 2.0 mSv/h and 0.02 mSv/h, respectively. The simulated doses turned out to be less than the limit, satisfying the domestic regulation. Conclusion These simulation results may serve as useful data in the prediction of hands dose absorbed by I-131 capsule handling. GEANT4 is considered that it will be effectively used in order to check the radiation dose.

  • PDF

NPS Pollution Loads from Coal Mining in Korea (석탄광산 작업장의 비점오염부하 유출특성)

  • Shin, Min-Hwan;Choi, Young-Hoon;Kim, Ki-Chul;Seo, Ji-Yeon;Lim, Kyoung-Jae;Choi, Joong-Dae
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2008.05a
    • /
    • pp.779-784
    • /
    • 2008
  • 환경부에서 추진하고 있는 토지피복 중분류별 비점오염부하원단위를 산정하기 위한 사업 중 나지로 분류되는 채광지역의 비점오염부하를 측정하였다. 비점오염부하는 강원도 삼척시 도계읍의 도계 작업장(석탄)과 태백시 장성동의 태백 저탄소 등 2곳의 채광지역에서 2007년 9월부터 12월까지 2회의 강우유출사상을 대상으로 측정하였다. 2회 강우사상 동안 총강수량은 도계 작업장에서 149 mm이었으며 태백 저탄소에서 201 mm이었다. 유출량은 수위계와 유량계로 5분 단위로 측정하였으며, 수질시료는 자동채수기로 2시간 간격으로 채취하였다. 수질시료는 환경부의 공정시험법에 따라 SS, BOD, CODcr, T-N, T-P, 그리고 TOC 농도를 분석하였다. 그리고 일부의 시료에 대해서는 Zn, Cb, Cu, 그리고 Pb의 농도를 분석하였다. 도계 작업장의 유량가중평균농도는 갱내수의 수질에 많은 영향을 받는 것으로 나타났다. 도계작업장의 일평균유량가중평균농도는 SS $86.3{\sim}94.9\;mg/{\ell}$, BOD $3.8{\sim}7.6\;mg/{\ell}$, COD $26.9{\sim}51.6\;mg/{\ell}$, T-N $1.5{\sim}2.1\;mg/{\ell}$, T-P $0.2\;mg/{\ell}$ 그리고 TOC $1.8{\sim}2.3\;mg/{\ell}$로 나타났다. 태백 저탄소의 일평균유량가중평균농도는 SS $16.5{\sim}66.6\;mg/{\ell}$, BOD $7.4{\sim}9.8\;mg/{\ell}$, COD $41.1{\sim}66.7\;mg/{\ell}$, T-N $0.7{\sim}1.1\;mg/{\ell}$, T-P $0.2\;mg/{\ell}$ 그리고 TOC $1.7{\sim}2.6\;mg/{\ell}$로 나타났다. 중금속의 농도는 모든 시료에서 환경부의 배출허용기준농도보다 낮게 나타나거나 검출되지 않았다. 도계 작업장의 일오염부하는 SS $1,368.8{\sim}1,984.1\;kg/day$, BOD $56.6{\sim}128.9\;kg/day$, COD $385.7{\sim}933.7\;kg/day$, T-N $23.4{\sim}44.5\;kg/day$, T-P $2.1{\sim}4.8\;kg/day$ 그리고 TOC $24.3{\sim}39.3\;kg/day$이었다. 태백 저탄소의 일오염부하는 SS $8.2{\sim}162.1\;kg/day$, BOD $2.6{\sim}15.3\;kg/day$, COD $13.8{\sim}83.6\;kg/day$, T-N $0.2{\sim}3.1\;kg/day$, T-P $0.1{\sim}0.6\;kg/day$ 그리고 TOC $0.7{\sim}4.4\;kg/day$로 나타났다. 본 연구는 2회의 강우유출사상에 대하여 측정한 자료이므로 연평균농도나 연평균오염부하로 활용하기는 어렵다. 그러나 석탄광산지역의 비점오염부하를 이해하는데 활용할 수 있으며 또한 장기적인 연구자료로 활용하여 석탄광산지역의 비점오염원단위의 산정에 유용한 자료로 활용할 수 있다.

  • PDF

Study on the On-Board Test of After-Treatment Systems to Reduce PM-NOx in Low-Speed Marine Diesel Engine (선박용 저속디젤엔진 적용을 위한 PM-NOx 동시저감 배출저감설비 해상실증 연구)

  • Dong-Kyun Ko;Suk-Young Jeong;In-Seob Kim;Gye-Won An;Youn-Woo Nam
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.29 no.5
    • /
    • pp.497-504
    • /
    • 2023
  • In this study, Selective catalytic reduction (SCR) + Diesel particulate filter (DPF) system was installed on a ship with a low-speed engine to conduct the on-board test. The target ship (2,881 gross tons, rated power 1,470 kW@240 rpm ×1) is a general cargo ship sailing in the coastal area. Drawing development, approvals and temporary survey of the ship were performed for the installation of the after-treatment system. For performance evaluation, the gaseous emission analyzer was used according to the NOx technical code and ISO-8178 method of measurement. The particulate matter analyzer used a smoke meter to measure black carbon, as discussed by the International Maritime Organization (IMO). Tests were conducted using MGO (0.043%) and LSFO (0.42%) fuels according to the sulfur content. The test conditions were selected by considering the engine rpm (130, 160 and 180). Gaseous emission and particulate matter (smoke) were measured according to the test conditions to confirm the reduction efficiency of the after treatment system. The results of NOx emission and particulate matter (smoke) revealed that reduction efficiency was more than 90%. The exhaust pressure met the allowable back pressure (less than 50 mbar). This study confirms the importance of the on-board test and the potential of SCR + DPF systems as a response technology for reducing nitrogen oxides and particulate matter.

Assessment of the Residues of Benfuresate and Oxolinic Acid in Crops (Benfuresate와 Oxolinic Acid의 작물체중 잔류량 평가)

  • Park, Dong-Sik;Yang, Jae-E.;Han, Dae-Sung
    • Korean Journal of Environmental Agriculture
    • /
    • v.14 no.3
    • /
    • pp.312-318
    • /
    • 1995
  • Residues of benfuresate in rice and oxolinic acid in Chinese cabbage were determined through the field experiments in order to establish the safe use and the maximum residue limit(MRL) of these pesticides in Korea. The herbicide benfuresate powder was sprayed into the paddy field with a level of 0.6kg(active ingredient)/ha and rice (Oryza sativa L.) was grown. At harvest, residues of benfuresate in brown rice and stem were analyzed using gas chromatograph. The residue of oxolinic acid in Chinese cabbage (Brassica campestris subsp. napus var pekinesis MAKINO) was analyzed using HPLC after foliar-spraying this fungicide into the cabbages at a level of 15kg/ha. The recovery efficiencies of benfuresate and oxolinic acid were 87-89% and 90-95%, respectively. The respective residues of benfuresate in rice and oxolinic acid in Chinese cabbage were in the range of 0.27-0.46 mg/kg and 0.23-1.53kg/kg. Residual concentrations of these pesticides in crops increased with the increased application frequencies, followed the first-order kinetics and linearly decreased with time. The highest residue of 1.53 mg/kg of oxolinic acid was observed when this fungicide was sprayed six times until three days prior to harvest, but this level was far lower t㏊n 5 mg/kg, which is the maximum residue limit(MRL) set by FAO/WHO.

  • PDF

A Study on Residual Pesticides in Commercial Fruits & Vegetables (시중 유통 과채류 중의 잔류농약에 관한 연구)

  • Kim, Young-Gook;Lim, Tae-Gon;Park, Sang-Su;Heo, Nam-Chil;Hong, Suk-Soon
    • Korean Journal of Food Science and Technology
    • /
    • v.32 no.4
    • /
    • pp.763-771
    • /
    • 2000
  • The 88 kinds of pesticide residues were analyzed in 12 kinds(289 samples) of fruits and vegetables brought at department store & mart in Kwangju from Feburary to September in 1999. The detection rate of pesticide residue in 12 kinds(289 samples) of fruits and vegetables was 21.1%, and the rate exceeds standard was 5.2%. The order of highly exceed rate in fruits and vegetables were perilla leaf, lettuce, spinach and chickery. The order of pesticide which founded frequently in fruits and vegetables were procymidone, endosulfan, vinclozoline, chlorpyrifos, cyprermethrin, pirimiphos-M, fenvalerate, fenarimol, and monocrotophos. And that of pesticide which exceed highly standard were procymidone, vinclozolin, endosulfan, pirimiphos-M, fenarimol, monocrotophos, etc. Eight different washing methods were compared for removal efficiencies of residual pesticides(procymidone, vinclozoline) on the perilla leap, the lettuce, the spinach, the strawberry, and the minitomato. Residual pesticides such as procymidone and vinclozoline were removed most efficiently by ultrasonic washing.

  • PDF

Evaluation of Structural Stability of Plastic Greenhouses with Steel Spiral Piles on Reclaimed Lands (간척지에서 강재 나선말뚝기초를 적용한 플라스틱 온실의 안전성 평가)

  • Yum, Sung Hyun;Lee, Won Bok
    • Journal of Bio-Environment Control
    • /
    • v.26 no.1
    • /
    • pp.27-34
    • /
    • 2017
  • This study was carried out to estimate structural stabilities in respect of ground footings of plastic greenhouses on reclaimed lands. A 6m-wide multi-span plastic greenhouse with steel spiral piles as well as two 8.2m-wide single-span greenhouses with steel spiral piles and continuous pipe foundation respectively were built up on a reclaimed land with a SPT N-Value of 2 and measured how much the greenhouses were lifted up and subsided. In addition, the uplift capacity of three kinds of spiral piles(${\phi}50$, ${\phi}75$ and ${\phi}100$) was determined on a nearby reclaimed land. The results showed that the greenhouses with spiral piles had a slight vertical displacement like moving up and down but the scales of the rising up and sinking were negligible when compared to that of the greenhouses. The vertical displacement of the multi-span greenhouse ranged from +9.0mm(uplift) to -11.5mm(subsidence). As for the single-span greenhouses with spiral piles and continuous pipe foundation, the measurements showed that it varied from +1.3mm to -7.7mm and from +0.9mm to -11.2mm, respectively. The allowable uplift capacity of spiral piles could all be determined under criteria of ultimate load and accordingly had a value of 0.40kN, 1.0kN and 2.5kN, respectively. It was not entirely certain enough to make a final judgement on structural stabilities in respect of ground footings, it appeared likely however that the greenhouses with steel spiral piles was tentatively observed without any problems on reclaimed lands within the period.

Computation of $Q_{10}$ Values and Shelf-life for Canned and Bottled Orange Juices (캔 및 병 오렌지쥬스의 저장온도에 따른 $Q_{10}$값 및 품질수명의 산정)

  • Lee, Nam-Kyung;Yoon, Jae-Young;Lee, Su-Rae
    • Korean Journal of Food Science and Technology
    • /
    • v.27 no.5
    • /
    • pp.748-752
    • /
    • 1995
  • Canned and bottled orange juices currently sold in Korean market were stored for 24 weeks at 20, 30, 40 and $50^{\circ}C$ and analyzed after opening at 4 week intervals. Activation energy, $Q_{10}$ values and shelf-life at respective temperatures were calculated from the data on various quality indexes. Proposed indexes were lead, tin, iron and vitamin C contents in canned juices and vitamin C content and browning index in bottled juices and $Q_{10}$ values for these parameters were in the range of $1.3{\sim}2.0$. Shelf-life calculated for canned juices at 10, 20 and $30^{\circ}C$ were 10, 6 and 3 months and that in bottled juices, 24, 12 and 6 months, respectively. When the distribution temperature of juices in Korea is assumed to be $15^{\circ}C$ average, the optimum shelf-life was estimated to be 8 months in canned juices and 18 months in bottled juices. In order to ascertain the safety of canned orange juices, efforts are needed to re-examine the recommended distribution period, legal limit for lead and improvement of container materials.

  • PDF

Risk Evaluation and Analysis on Simulation Model of Fire Evacuation based on CFD - Focusing on Incheon Bus Terminal Station (CFD기반 화재 대피 시뮬레이션 모델을 적용한 위험도 평가 분석 -인천터미널역 역사를 대상으로)

  • Kim, Min Gyu;Joo, Yong Jin;Park, Soo Hong
    • Spatial Information Research
    • /
    • v.21 no.6
    • /
    • pp.43-55
    • /
    • 2013
  • Recently, the research to visualize and to reproduce evacuation situations such as terrorism, the disaster and fire indoor space has been come into the spotlight and designing a model for interior space and reliable analysis through safety evaluation of the life is required. Therefore, this paper aims to develop simulation model which is able to suggest evacuation route guidance and safety analysis by considering the major risk factor of fire in actual building. First of all, we designed 3D-based fire and evacuation model at a subway station building in Incheon and performed fire risk analysis through thermal parameters on the basis of interior materials supplied by Incheon Transit Corporation. In order to evaluate safety of a life, ASET (Available Safe Egress Time), which is the time for occupants to endure without damage, and RSET (Required Safe Egress Time) are calculated through evacuation simulation by Fire Dynamics Simulator. Finally, we can come to the conclusion that a more realistic safety assessment is carried out through indoor space model based on 3-dimension building information and simulation analysis applied by safety guideline for measurement of fire and evacuation risk.