• Title/Summary/Keyword: 측정표준기술

Search Result 929, Processing Time 0.036 seconds

A Study on Development for ESCO MRV Plan and Result Reporting Outlines to ESCO Energy Conservation Business (ESCO 에너지절약 MRV 계획서 및 결과서 표준양식 개발방안 연구)

  • Lim, Ki Choo
    • Journal of Energy Engineering
    • /
    • v.25 no.3
    • /
    • pp.157-164
    • /
    • 2016
  • This paper aims to create standard forms of MRV plan and report, used when policy funds are applied in accordance with ESCO regulations, when energy savings are measured (the savings would be generated as energy users and ESCOs signed the contract of guarantee for energy savings, and energy saving facilities are installed following the contract). To fully reflect the goals and effects of the installation of energy saving facilities, MRV plans and reports will be completed for the purposes of measuring, verifying, and reporting if the goals of energy savings have been achieved successfully. In this paper, the forms of MRV plans and reports were developed with the detailed descriptions for each form and instructions of completion. Based on the developed forms of MRV plans and reports, future studies need to developed guidelines to explain how to fill out these forms considering the application cases by ESCO technology and facility.

The Study on Bone Mineral Density Measurement Error in Accordance with Change in ROI by Utilizing Dual Energy X-ray Absorptiometry (DEXA를 이용한 골밀도 측정시 검사자의 ROI 변화에 따른 골밀도 측정값의 오차에 관한 연구)

  • Lee, Yun-Hong;Lee, In-Ja;Yong, Hyung-Jin
    • Journal of radiological science and technology
    • /
    • v.35 no.1
    • /
    • pp.1-7
    • /
    • 2012
  • Dual Energy X-ray Absorptiometry(DEXA) is commonly used to diagnose Osteoporosis. The errors of DEXA bone density operation are caused by operator, bone mineral density meter, blood testing, patient. We focus on operator error then study about how much influence operator's region of intest(ROI) in bone testing result. During from March to July in 2011. 50 patients ware selected respectively from 30, 40, 50, 60, and 70 age groups who came to Korea University Medical Center(KUMC) for their Osteoporosis treatment. A-test was performed with usually ROI and B-test was performed with most widely ROI. Then, We compare A-test and B-test for find maximum difference of T-score error which occurred operator ROI controlling. Standard deviation of T-score of B-test showed 0.1 higher then A-test in femur neck. Standard deviation of B-test showed 0.2 higher then A-test in Ward's area which in Greater trocanter and Inter trocanter. Standard deviation of B-test showed 0,1 lower then A-test in L-1. Bone density testing about Two hundred patients results are as follow. When operator ROI was changed wider than normal ROI, bone density of femur was measured more higher but bone density of L-spine was measured more lower then normal bone density. That means, sometime DEXA bone density testing result is dependent by operator ROI controlling. This is relevant with the patient's medicine and health insurance, thus, tester always keep the size of ROI for to prevent any problem in the patient.

RMS-AV 검파 방식과 가전기기 적용에 대한 고려

  • Kim, In-Seok;Jo, Hui-Gon;An, Hui-Seong
    • The Proceeding of the Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.1
    • /
    • pp.52-62
    • /
    • 2011
  • 본고에서는 최근 디지털 통신 시스템에 대한 국제 표준으로 도입된 RMS-AV 가중치 측정법을 CISPR F쪽으로의 도입 문제가 거론되는 상황에서 현존하는 가중치 측정법에 관련된 기본적인 내용을 검토하고, 참고문헌 [13]에서 제시하였던 방법을 이용하여 와인 냉장고와 두 종류의 전기 드릴에 대하여 RMS-AV 가중치 측정법을 전도성 방출 특성과 복사성 방출 특성을 AM 방송 송출시, 방송 중단 시, 차폐 실내 등의 다양한 환경에서 측정하여 EMI 수신기에서 적용되고 있는 가중치를 실험적으로 비교하였다. 비교 결과, 다양한 가중치 측정법이 동일한 결과를 제시하지 못하여 RMS-AV 측정법이 CISPR F쪽으로의 도입은 좀 더 연구가 필요한 주제로 판단되었고, 결론 부분에서 RMS-AV 측정법에 대한 여러 가지 문제점을 고려해 보았다.

전자총 휘도 측정 시스템의 개발

  • Jo, Bok-Rae;Bae, Mun-Seop;An, Jong-Rok;An, Sang-Jeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.149.1-149.1
    • /
    • 2014
  • 전자총의 방출전류량과 소스크기, 그리고 방출 각전류밀도(angular current density)를 측정함으로서 얻어지는 전자총의 휘도(brightness)는 대물렌즈의 수차와 더불어 전자현미경의 성능을 좌우한다. 국내업체의 전자현미경은 대부분 상대적으로 휘도가 낮지만 작동압력이 10-5 Torr의 이하여서 제작과 사용이 용이한 텅스텐 필라멘트 열전자총을 채용하고 있다. 주사전자현미경의 성능을 좌우하는 프로브 크기와 전류량은 광학계의 배율과 전자총의 휘도에 의해서 결정되며, 설계시 전자현미경의 사양을 결정하기 위해서는 전자총의 휘도 측정이 필수이다. 한국표준과학연구원에서는 국내에서 생산되는 전자현미경용 열전자총의 휘도를 측정하기 위해, 전자총의 방출 각전류밀도와 소스 크기를 측정할 수 있는 전자총 휘도 측정 시스템을 개발하고 있다. 본 발표에서는 개발중인 시스템의 측정 원리를 기술한다. 또한 외부 자기장에 의한 교란을 방지하기 위해 연자성 재료인 연강으로 제작한 진공챔버의 진공특성을 보고한다.

  • PDF

Optimal Conditions for Pretreated Sample for Sr Isotope Analysis by MC-ICP-MS: A Comparison Between Eichrom (SR-R50-S)'s and Bio-Rad(AG®50W-X8)'s Resins (다검출기 유도결합 플라즈마 질량분석기에 의한 Sr 동위원소 분석을 위해 전처리된 시료의 최적 조건: Eichrom사 Sr 수지(SR-R50-S)와 Bio-Rad사 수지(AG®50W-X8) 비교)

  • Myoung Jung, Kim;Seung-Gu, Lee
    • Korean Journal of Mineralogy and Petrology
    • /
    • v.35 no.4
    • /
    • pp.507-520
    • /
    • 2022
  • The Sr isotope ratio, which is used as basic data for rock formation time, crustal and mantle evolution studies, is determined by mass spectrometer such as thermal ionization mass spectrometry (TIMS) or multi-detector inductively coupled plasma mass spectrometry (MC-ICP-MS). In this technical report, we compared how incomplete chemical separation of elements affects the determination of Sr isotope ratios. For the experiment, commercial resin, NBS987(NIST SRM987) Sr isotope standard, and rock standard samples from the Geological Survey of Japan (GSJ) such as JG1a, JB3 and JA1 were used. As a result of the comparative experiment, it was clearly observed that the measured values of 87Sr/86Sr change when Rb remains due to incomplete separation of the NBS987 Sr isotope standard sample as well as the rock standard samples of GSJ. This indicates that complete separation is an important factor since the calculated value deviates from the true value even though correction for isotope interference by isobar is performed when measuring the isotope ratio with MC-ICP-MS. This also suggests that, when reporting the measurement result of Sr isotope ratio using MC-ICP-MS, the measurement strength of 85Rb should be reported together with the measurement strength of all isotopes of Sr so that isotope interference by isobar can be judged.

공정현장 적응능력 평가를 위한 드라이펌프의 실시간 특성분석

  • Choe, Gyeong-Min;Kim, Wan-Jung;Jeong, Wan-Seop;Im, Jong-Yeon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.145.2-145.2
    • /
    • 2014
  • 최근 반도체 산업의 급속한 발전으로 반도체 생산 설비 시설 또한 꾸준히 증설되어가는 추세이다. 이에 따라 반도체 산업의 핵심기술로 부각되고 있는 진공 기술은 다양한 응용목적을 위한 진공시스템 설계와 운영을 필요로 한다. 진공시스템의 알맞은 설계는 시스템 구성에 따른 진공특성을 예측하는 것이 중요하며 목적에 부합한 진공펌프를 선택하고 운영하여 최소비용으로 시스템 활용효율성을 극대화할 수 있는 설계를 해야 한다. 또한 공정의 저전력, 대유량화 추세에 따라 고유량 영역의 드라이펌프 부하 내구성 대응 요구에 부응하는 객관적 내구성평가의 정립 및 표준 측정 시험평가 방법의 필요성이 점차 대두되고 있는 경향에 있다. 본 연구에서는 드라이펌프의 공정현장 적응능력 평가를 위하여 최소 1시간에서 3시간동안 압력별 가스부하에 따른 드라이펌프의 실시간 특성을 관찰하였다. 실험은 1 mbar에서 최대 300 mbar까지의 연속적인 부하 조건에서 유량, 진동, 소음, 소비전력과 Sudden Vent Test를 실시간으로 측정하였고 드라이펌프의 특성 분석은 각 용량별 압력에 따른 유량, DP BP 소비전력, 소음, 진동, DP Body Temperature 등의 데이터를 Type에 따라 비교 분석하였다. 이에 부응하는 평가 장치 구축 및 데이터분석은 한국표준과학연구원 진공펌프 평가실험실에서 수행되었다.

  • PDF

Design and Implementation of Voice Quality Management System by using MGCP parameter in VoIP Service (MGCP Parameter를 이용한 VoIP서비스 음성품질 관리 시스템 설계 및 구현)

  • 류내원;황부현
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2004.10c
    • /
    • pp.325-327
    • /
    • 2004
  • VoIP는 음성 및 데이터 통합 뿐만 아니라 차세대 네트웍 등의 기반이 되는 기술이며, 인터넷전화 / IP Telephony, 화상회의, 메신저 서비스 등 여러 서비스에 활용되고 있다. 이러한 VoIP 서비스 제공시에 가장 중요시되는 부분이 음성품질이며 이를 측정 및 관리하는 기술이 필수적으로 필요하다. 지금까지는 품질측정장비를 가지고 직접 측정하는 것이 전부였으나 본 연구는 IETF의 VoIP 표준 프로토콜인 MGCP중 파라미터 값을 이용하여 ITU-T의 음성품질 기준인 R factor(G.107)를 계산해 내고 중앙에서 모든 단말 및 사용자들의 실제 발생한 통화에 대한 음성품질을 관리할 수 있는 시스템을 설계 및 구현한다.

  • PDF

A study of expansion performance of high expansion foam concentrate on variation of temperature (고발포 소화약제의 온도 변화에 따른 발포성능에 관한 연구)

  • Kim, Ha-Young;Lee, In-Gu;Rie, Dong-Ho
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2010.04a
    • /
    • pp.79-83
    • /
    • 2010
  • 포소화약제는 다양한 설비(이동식, 고정자동식), 대형의 유류화재 적합, 대량 연속적 생산가능 약제의 특수성 및 장기보관이 가능한 특징이 있어 이에 대한 개발 및 연구가 꾸준히 진행되고 있다. 그러나 포소화약제는 주변의 온도 및 환경에 따라 발포력의 변화가 큰 특징이 있어 실제 겨울철 소방 활동시에는 사용을 자제하고 있다. 따라서 본 연구에서는 사용온도에 따른 발포력 변화를 측정하며, 최적 발포율 도출을 위한 온도에 따른 적정 혼합율을 산정한다. 실험은 한국 소방산업기술원의 "포소화약제의 형식승인 및 검정기술기준(KOFEIS 0103)"에서 제시하고 있는 표준 발포기를 이용 측정하며, $5{\sim}30^{\circ}C$ 온도에서 혼합률에 따른 발포력 변화를 측정하였다.

  • PDF

Dimension Measurement of Nuclear Fuel Rods Using an Image Processing Technology (영상처리기술에 의한 핵연료봉의 제원 측정)

  • Koo, D.S.;Min, D.K.;You, G.S.;Shin, H.S.;Hong, K.P.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.19 no.2
    • /
    • pp.79-84
    • /
    • 1999
  • An image processing technology was developed to measure the dimension of nuclear fuel rods and the diameter of nuclear fuel rods was measured by this method. It was confirmed that parameters such as camera-to-specimen distance. camera location, light intensity and light characteristic would affect dimension measurement of nuclear fuel rods. The percent relative error and percent standard deviation of measuring the diameter of nuclear fuel rods using image processing method were 4.88%, ${\pm}3.34%$ while the percent relative error and percent standard deviation using conventional method were 12.7%, ${\pm}9.72%$, respectively. The accuracy of diameter measurement of nuclear fuel rods using image processing method was about 3 times as high as that using conventional method.

  • PDF

The Status and Improvement of Hydrological Survey Standardization (수문조사 표준화 현황 및 개선방안)

  • Shim, Eun Jeung;Kim, Sam Eun;Jang, Bok Jin;Jung, Sung Won
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2018.05a
    • /
    • pp.471-471
    • /
    • 2018
  • 국가 수자원 관리에 가장 기초가 되는 수문조사는 측정과 자료 분석을 위해 행해지는 모든 과정에서 자료의 정확성과 신뢰성이 담보되어야 한다. 현재 수문조사는 국토교통부를 비롯하여 환경부, 수자원공사 등 다양한 부처와 기관에서 수행하고 있으며, 수문조사 방법 및 기준표준화 연구(2009), 수문조사 관련 법정 행정규칙 마련, 수자원 조사법 제정, 수문자료 공인 및 저장, 배포, 활용, 기준고시 등을 통해 수문조사 발전 및 표준화를 위한 노력을 해오고 있다. 하지만 국가차원의 표준화(기준과 매뉴얼)가 아직 미진하여 기관별 생산 자료의 품질차이가 발생하고 있다. 국내의 현장여건은 식생, 공사, 모래하상 등으로 과거와 다르게 점차 다양화 되고 있으며, 국외와 차별화 된 국내 하천만의 특성으로 반영되고 있다. 또한 최근 ADCP와 같은 첨단장비 활용이 증대되는 추세인데 비해 첨단장비 관련 기준은 아직 미비한 부분이 많다. 국내 측정환경이 고려된 수문조사 표준화를 위해서는 USGS와 같은 선진국의 국제기준 검토와 함께 각 하천 환경에 맞는 유량측정 방법 및 기술을 개발하고, 다양한 현장 특성이 반영된 측정방법의 적용과, 자료 분석을 통한 기준제시가 필요하다. 첨단 장비 및 관련 기술을 활용한 수문조사 선진화를 위해서는 정확한 첨단장비 활용에 대한 표준이 필요하다. 즉 수문조사 전반에 대한 표준화와 이를 통한 공유와 활용이 이루어져야 한다. 한국수자원조사기술원(구 유량조사사업단)에서는 2007년부터 수문조사를 수행하면서 국내 하천유량조사 경험과 기술 노하우를 바탕으로 수문조사 분야별 측정방법, 장비, 레이팅, 자료 분석 등에 대한 수문조사매뉴얼과 가이드라인을 발간하여 실무에 적용, 활용하고 있다. 이러한 노력은 국내 수문조사 표준화를 정착, 발전시키고 국제 표준화에 기여할 수 있는 계기가 될 것으로 생각된다.

  • PDF