• Title/Summary/Keyword: 측정잡음

Search Result 1,744, Processing Time 0.03 seconds

1/f Noise Characteristics of N-MOSFETS fabricated by BiCMOS process (BiCMOS공정 N-MOSFET 소자의 1/f 잡음특성)

  • Koo, Hoe-Woo;Lee, Kie-Young
    • Journal of IKEEE
    • /
    • v.3 no.2 s.5
    • /
    • pp.226-235
    • /
    • 1999
  • To investigate SPICE noise model and the behavior of its parameters, 1/f noise of NMOS devices fabricated by BiCMOS process is measured and compared to the various noise models and measured results. For the long channel devices, bias dependence of the drain current noise power spectral density $S_{Id}$ of NMOS is similar to the previous results. Equivalent gate noise power spectral density $S_{Vg}$ shows weak dependence on the gate and drain voltages in long channel NMOS as the previous results. However, it is shown that most of published noise models are difficult to apply to short channel devices. Therefore, in this study, with comparison of our experimental results, we have tried to find the model of 1/f noise, appropriate for our NMOS device fabricated by BiCMOS process.

  • PDF

Phase error compensation for three-dimensional shape measurement based on a phase-shifting method (위상천이법을 이용한 삼차원 형상측정에서 위상오차 보정)

  • Park, Yoon-Chang;Ahn, Seong-Joon;Kang, Moon-Ho;Kwon, Young-Chul;Ahn, Seung-Joon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.11
    • /
    • pp.3023-3030
    • /
    • 2009
  • In this paper, a prediction and compensation method for the error in the phase measured by using the proportionality between two wavelengths in the TW-PMP (Two-wavelength Phase Measuring Profilometry) is proposed and experimental results are shown to verify the usefulness of the proposed method. For sample object, firstly, a phase-shifting with a quite large number of steps is adopted in measurement, compared with the conventional phase-shifting method, secondly, a 3-3 step phase-shifting method is used to measure the same object which is applied to high-speed 3D shape measurement, and then, measured results from these two phase-shifting methods are compared to calculate measurement noises. From the experimental results applying the proposed compensation method to the measured beat phase and absolute phase, it has proven that noises are decreased by 90% and 17.2% for each case.

A Scalable Bias-dependent P-HEMT Noise Model with Single Drain Current Noise Source (드레인 전류 잡음원만을 고려한 스케일링이 가능한 바이어스 의존 P-HEMT 잡음모델)

  • 윤경식
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.24 no.10A
    • /
    • pp.1579-1587
    • /
    • 1999
  • Bias-dependent noise models of $0.2\mu\textrm{m}$ gate length P-HEMT's which are scalable with gate width are proposed. To predict S-parameters of the P-HEMT's the intrinsic parameters except for $\tau$ subtracted the offsets introduced in this paper are normalized to the gate width and then scaled. The small-signal model parameters are expressed as fitting functions of the drain current to $\textrm{I}_{dss}$ ratio and gate width. In addition, to estimate accurately noise parameters the noise temperature $\textrm{T}_{g}$ of the intrinsic resistance, the equivalent noise conductance $\textrm{G}_{ni}$ of the gate current noise source, and the equivalent noise conductance $\textrm{G}_{no}$ of the drain current noise source are adopted as the noise model parameters. The extracted values of $\textrm{T}_{g}$ are nearly independent of drain current and gate width and their average is around the ambient temperature. The extracted values of $\textrm{G}_{ni}$ are small enough to be neglected to the circuit characteristics. From the comparison of the noise model with only $\textrm{G}_{no}$ and that having $\textrm{T}_{g}$, $\textrm{G}_{ni}$ and $\textrm{G}_{no}$ to the measured data it is fund that even the former model is in good agreement with the measured noise parameters. Thus, from a practical point of view the noise model having only the drain current noise source is confirmed as a scalable bias-dependent model.

  • PDF

A New Design-for-Testability Circuit for Low Noise Amplifiers (저잡음 증폭기를 위한 새로운 구조의 검사용 설계회로)

  • Ryu Jee-Youl;Noh Seok-Ho
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.43 no.3 s.345
    • /
    • pp.68-77
    • /
    • 2006
  • This paper presents a new Design-for-Testability (DfT) circuit for 4.5-5.5GHz low noise amplifiers (LNAs). The DfT circuit measures gain, noise figure, input impedance, input return loss, and output signal-to-noise ratio for the LNA without external expensive equipment. The DfT circuit is designed using 0.18m SiGe technology. The circuit utilizes input impedance matching and DC output voltage measurements. The technique is simple and inexpensive.

An Improvement in Adaptive Estimation for a Tracking System with Additive Measurement Impulse noise (충격성 잡음이 혼입되는 추적계통의 적응 추정 개선)

  • 윤현보;박희창
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.12 no.5
    • /
    • pp.519-526
    • /
    • 1987
  • An adaptive estimation system which operates propoerly in the environments corrupted by additive impulse noise in addition to the white Gaussian noise has been proposed. A feed forward loop is inserted into the adaptive estimator proposed by R. L. Moose for a system with an unknown measurement bias by which the improved adaptive estimator is processed successfully without the sum of the time varying weights being zero even when the measurement system is added impulue noise. Successfully processed adaptive estimator has been obtained under the large impulse noise in addition to randomly varying unknown biases condition by giving sufficient large value to the elements of discrete vector on the computer simulation.

  • PDF

Analysis of De-noising by Thresholding (문턱치에 따른 잡음제거 분석)

  • Seo, Jung-Ick;Park, Eun-kyoo
    • Journal of the Korea society of information convergence
    • /
    • v.6 no.2
    • /
    • pp.45-49
    • /
    • 2013
  • Electrocardiogram(ECG) signal noise as well as conducting other bio-signal measurement were generated. It was intened to enhance the accuracy of cadiac disease diagnosis with removing signal white-noise. Sampling signal was made with generating white-noise. The noise were removed using wavelet transforms and thresholding. Removed noise were compared numerical using SNR(signal to noise ratio). The results compared SNR showed that SURE method was 5.931, 4.9301 in 3, 5dB noise, uninversal was 3.6590, 1.9698 in 7, 9dB noise. De-noising by Thresholding removed noise effectively. ECG signal is expected to improve the accuracy of cadiac desease dianosis.

  • PDF

Subband Based Spectrum Subtraction Algorithm (서브밴드에 기반한 스펙트럼 차감 알고리즘)

  • Choi, Jae-Seung
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.8 no.4
    • /
    • pp.555-560
    • /
    • 2013
  • This paper first proposes a classification algorithm which detects a voiced, unvoiced, and silence signal using distance measure, logarithm power and root mean square methods at each frame, then a spectrum subtraction algorithm based on a subband filter. The proposed algorithm subtracts spectrums of white noise and street noise from noisy signal based on the subband filter at each frame. In this experiment, experimental results of the proposed spectrum subtraction algorithm demonstrate using the speech and noise data of Aurora-2 database. Based on measuring the speech-to-noise ratio (SNR), experiments confirm that the proposed algorithm is effective for the speech by contaminated the noise. From the experiments, the improvement in the output SNR values was approximately 2.1 dB and 1.91 dB better for white noise and street noise, respectively.

Recognition of Noise Quantity by Linear Predictive Coefficient of Speech Signal (음성신호의 선형예측계수에 의한 잡음량의 인식)

  • Choi, Jae-Seung
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.46 no.2
    • /
    • pp.120-126
    • /
    • 2009
  • In order to reduce the noise quantity in a conversation under the noisy environment it is necessary for the signal processing system to process adaptively according to the noise quantity in order to enhance the performance. Therefore this paper presents a recognition method for noise quantity by linear predictive coefficient using a three layered neural network, which is trained using three kinds of speech that is degraded by various background noises. The performance of the proposed method for the noise quantity was evaluated based on the recognition rates for various noises. In the experiment, the average values of the recognition results were 98.4% or more for such noise using Aurora2 database.

A Study on Translation-Invariant Wavelet De-Noising with Multi-Thresholding Function (다중 임계치 함수의 TI 웨이브렛 잡음제거 기법)

  • Choi, Jae-Yong
    • The Journal of the Acoustical Society of Korea
    • /
    • v.25 no.7
    • /
    • pp.333-338
    • /
    • 2006
  • This paper proposes an improved do-noising method using multi-thresholding function based on translation-invariant (W) wavelet proposed by Donoho et al. for underwater radiated noise measurement. The traditional wavelet thresholding de-noising method causes Pseudo-Gibbs phenomena near singularities due to discrete wavelet transform. In order to suppress Pseudo-Gibbs Phenomena, a do-noising method combining multi-thresholding function with the translation-invariant wavelet transform is proposed in this paper. The multi-thresholding function is a modified soft-thresholding to each node according to the discriminated threshold so as to reject かon external noise and white gaussian noise. It is verified by numerical simulation. And the experimental results are confirmed through sea-trial using multi-single sensors.

A Novel Speech Enhancement Based on Speech/Noise-dominant Decision in Time-frequency Domain (시간-주파수 영역에서 음성/잡음 우세 결정에 의한 새로운 잡음처리)

  • 윤석현;유창동
    • The Journal of the Acoustical Society of Korea
    • /
    • v.20 no.3
    • /
    • pp.48-55
    • /
    • 2001
  • A novel method to reduce additive non-stationary noise is proposed. The method requires neither the information about noise nor the estimate of the noise statistics from any pause regions. The enhancement is performed on a band-by-band basis for each time frame. Based on both the decision on whether a particular band in a frame is speech or noise dominant and the masking property of the human auditory system, an appropriate amount of noise is reduced using spectral subtraction. The proposed method was tested on various noisy conditions (car noise, Fl6 noise, white Gaussian noise, pink noise, tank noise and babble noise) and on the basis of comparing segmental SNR with spectral subtraction method and visually inspecting the enhanced spectrograms and listening to the enhanced speech, the method was able to effectively reduce various noise while minimizing distortion to speech.

  • PDF