• Title/Summary/Keyword: 측정기준

Search Result 7,125, Processing Time 0.034 seconds

A Study on the Development of Solid Reference Electrode and Remote Protection Potential Measuring System (고체기준전극 및 원격전위측정 시스템 개발에 관한 연구)

  • Ryou, Young-don;Kim, Jin-Jun;Kim, Dong-Kyun
    • Journal of the Korean Institute of Gas
    • /
    • v.19 no.3
    • /
    • pp.38-43
    • /
    • 2015
  • For buried gas pipelines, cathodic protection system shall be installed to protect against corrosion. The surveys of pipe-to-soil potentials for the gas pipelines should be carried out at the test box more than once a year. In urban, the test box is usually located on the driveway, therefore, it is difficult to measure the potentials. That is, traffic control is needed when carrying out the measurements of the potentials on daytime, or measurements of pipe-to-soil potentials at the test box located on the driveway have to be carried out in the late night when the traffic is light. We have developed remote potential monitoring system using the solid reference electrode and the wireless communication technology for the purpose of removing above problems. We have installed the developed solid reference electrodes at a site and monitored the potentials by wireless communication. Measured potential values were transferred to the server in office and analyzed. We have found the pipe-to-soil potentials transferred to the web server make no difference to the potentials measured directly on the site.

A Study Absolute Position Estimation of Sound Source (3차원 음향홀로그래픽을 이용한 음원위치 추정에 관한 연구)

  • Kim, Chun-Duk;Sim, Dong-Youn;Jang, Bee;Lee, Chai-Bong;Cha, Kyung-Hwan
    • The Journal of the Acoustical Society of Korea
    • /
    • v.16 no.5
    • /
    • pp.76-82
    • /
    • 1997
  • The paper describes simulations and experimental results using a measuring system which utilizes the acoustic holographic method in order to exactly estimate an absolute position of a sound source. The measuring surface is installed to satisfy with a far field to the sound source and is composed of linear arrayed seven microphones. A measurement is simultaneously recorded by a reference microphone setting up a neighbour sound source and the linear arrayed seven microphones which are moved to the same interval. An absolute position of sound source is estimated by the cross-spectrum method to the received sounds between a reference and the measuring microphones. Phase differences of each microphone and time delays during scanning are compensated to the reference microphone and the measuring time of the first column. An optimal interval for each microphone in the measuring surface is decided by a numerical simulation. A source signal makes use of a sinusoid, and S/N ratio is 30dB in the experiment. The optimal microphone's interval in the simulation and the experiment is decided in order to satisfy with the Nyquist space sampling condition related to the wave length of 2kHz sinusoid. Mainlobe width of a estimated 3D hologram in the case of 2kHz source signal is decreased to 87% and 30% in comparison to 500Hz and 1kHz, and then a valid of simulation results is confirmed. Therefore, we verified a utilization of the study for a sound source estimation using 3ㅇ acoustic holographic method.

  • PDF

Agreement and Digit Preference of Blood Pressure Measurements Between pairs of Random-Zero Sphygmomanometer, Digit Automatic Device and Regular Mercury Sphygmomanometer on Hypertensive Urban Young African-American Men (도시지역 고혈압을 가진 젊은 흑인 남성들의 Random-Zero Sphygmomanometer, Digit Automatic Device 와 Regular Mercury Spygmomanometer 사이의 혈압측정 방법에 의한 일치도와 점(숫자)선호도)

  • Park, Kyung-Min
    • Research in Community and Public Health Nursing
    • /
    • v.7 no.1
    • /
    • pp.170-177
    • /
    • 1996
  • 신체의 활력을 측정하는 혈압은 다른 어느 측정치보다 변동이 심하고 정상적으로 변할 수 있는 생리적 현상이어서 정확하게 측정하기란 쉽지 않다. 1mmHg 차이의 혈압일지라도, 특히 큰 집단일 경우, 연구목적에서 그 결과를 크게 왜곡 시킬 수 있다. (Wright & dore, 1970). 혈압 측정에는 직접적 방법과 간접적 방법이 있다. 이 중 간접적 방법은 임상분야와 연구분야에서 실제로 넓게 사용되고 있을 분만 아니라 신체로의 직접적 침투하는 방법도 아니고 가격 또한 비싸지 않다. 그러나, 간접적 측정 방법은 혈압에 영향을 끼치는 많은 요인들인 관찰자 편견, 확장기음의 청취음 선택, 관찰자와 환자 사이의 상호관계 때문에 방법론적으로 문제제기가 되기도 한다. 이런 요인을 최소화하기 위하여 가장 타당도가 높은 측정도구의 선택이 필요하다. 도시지역의(Ease Baltimore) 고혈압을 가진 젊은 흑인 남성(연령별/성별/종속별/거주지역) 중 수축기 혈압이 140mmHg 이고 확장기 혈압이 90mmHg인 사람, 또는 확장기 혈압이 90mmHg인 사람, 또는 혈압하강제를 먹고 있는 사람 200명을 대상으로 훈련받은 community health worker(CHW)에 의해 Random-Zero Sphygmdmanometer(RZS)와 Digit Automatic Device(DAD)로 혈압을 측정하게 하였다. 이 중 36명을 무작위 추출하여 regular Mercury Sphygmdmanometer (RMS)로 혈압을 측정하게 했다. Bland 와 Altman에 의해 제기된 두측정값의 차이에 대한 scattergram(일치도 검증법)과 AAMI(Association for the Advancement of Medical Instrument) 기준, BHS 기준, Central Tendency와 숫자선호도로 검증되었다. AAMI와 BHS 기준에 의하면 확장기 혈압에서 RZS와 DAD의 일치도와 평균을 중심으로 더 넓게 퍼져있어 낮은 일치도를 보였으며 또 DAD와 RMS의 혈압치는 숫자 선호도를 볼 수 있는데 특히 RMS는 더 뚜렷하게 나타났는데 확장기 혈압의 최빈치(30.6)는 100mmHg이었다. 혈압치들이 가장 가까이 "0"점으로 치우쳐져 있었다. RZS의 Central tendency는 DAD와 RMS보다 뚜렷하였다. 결론적으로 RZS는 이 연구목적으로 가장 적절함을 보여준다.

  • PDF

Moving Patterns of Patients and Its Implication for Regional Unbalance in Health Resources (환자이동현황을 고려한 병상공급 방향)

  • Yun, Heesuk
    • KDI Journal of Economic Policy
    • /
    • v.29 no.1
    • /
    • pp.41-78
    • /
    • 2007
  • Due to the concern of regional unbalance relating to healthcare resources, the government has set up a plan to expand public healthcare services and a policy to manage the supply of hospital beds. However, it is not clear what standards are needed to measure the degree of unbalance, and to what extent the gap needs to be narrowed. Unlike the previous methodology comparing the proportions of patients who move out from their administrative district to receive medical services, this study examines the inconvenience gap patients experience when they have to move out from their actual living area. The logit and multinomial logit models are employed. The regional unbalance decreases when the degree of movement is measured based on the living area. This result implies that essential standard for achieving regional balance relating to medical services need to be based not on the even distribution of medical resources, but the complications of regional people that require proper medical services.

Notch Sensitivity Analysis for the Rock Fracture Toughness (암석의 파괴인성계수와 균열감응도의 해석)

  • 백환조
    • Tunnel and Underground Space
    • /
    • v.7 no.2
    • /
    • pp.143-149
    • /
    • 1997
  • 암석의 파괴인성계수(fracture toughness)는 균열의 성장에 대한 암석의 저항을 나타낸다. 실험실에서 측정한 파괴인성계수는 일반적인 암석의 불균질성이나 이방성 외에도 시험편의 형상이나 하중조건에 의하여 크게 영향을 받는다. 따라서, 제한된 수의 시험편을 사용하여 측정된 파괴인성계수는 자료의 분산이 심하므로 실제 적용에 있어서 문제가 된다. 균열감응도란 파괴인성계수의 측정에 사용되는 시험편의 형상에 따라 결정되는 지수로서, 시험편의 파괴가 균열의 성장에 의한 것인지, 혹은 인장강도에 의한 것인지를 판별하는 기준이 된다. 이러한 균열감응도를 파악하여 암석의 파괴인성계수 측정에 유효한 시험편의 크기나 초기균열 길이의 범위를 설정할 수 있다. 이는 또한 실험실에서 측정된 차괴인성계수의 유효성 여부를 판별하는 기준으로 사용될 수 있다. 본 논문에서는 암석의 파괴인성계수의 측정에 흔히 사용되는 몇 가지 형태의 시험편들에 대하여 균열감응도를 계산하고 이에 따른 초기균열 길이의 범위를 제시하고자 한다.

  • PDF

COBIT 프레임워크를 활용한 정보보호 성숙도 측정에 관한 연구 - 정보보호 거버넌스 관점을 중심으로 -

  • Cho, Hee-Joon;Park, Sung-Kap;Min, Dae-Hwan
    • Review of KIISC
    • /
    • v.23 no.4
    • /
    • pp.22-28
    • /
    • 2013
  • 정보보호의 중요성으로 공공기관이나 일반 기업은 정보보호관리체계를 수립, 운영하고 있거나 정보보호 활동을 하고 있다. 하지만 정보보호관리체계나 정보보호 활동에 대한 성과측정이 불명확한 기준을 가지고 있거나 명확한 기준이 없는 것이 현실적인 문제점이다. 이러한 문제점으로 적절한 성과측정이 이루어지지 않기 때문에 현재의 정보보호 수준을 올바르게 측정할 수 없을 뿐만 아니라 그에 따른 성과개선을 하기에도 어려운 실정이다. COBIT 프레임워크의 정보보호 성숙도 모델을 활용하여 정보보호 거버넌스 관점과 연계함으로써 정보보호 성과에 대한 측정지표를 구체적으로 제시하고자 한다. 구체적인 정보보호 성과에 대한 측정지표를 활용함으로써 현재의 정보보호 수준을 파악하고 나아가서 정보보호 수준을 개선하고자 하는데 이 연구의 의미를 두고 있다.

The dynamic measured vibration and shock acceleration of an electrical equipments for transported by road vehicles (차량수송에 의한 전기기기의 진동과 충격가속도 실측)

  • Kim, Myoung-Seok;Oh, Joon-Sick;Han, Gyu-Hwan;Park, Joong-Hwa
    • Proceedings of the KIEE Conference
    • /
    • 2007.10c
    • /
    • pp.93-94
    • /
    • 2007
  • 운송 중에 발생되는 진동, 충격이 전기기기에 미치는 영향을 검증하기 위해 측정자료를 바탕으로 실험실에서 보리 실험한 수 있는 실험기준을 설정할 필요가 있다. 이를 위해 측정절차를 수립하고 발생요인에 따른 실측자료를 확보하기 위해 진동과 충격을 측정하는 시스템을 개발하였다. 측정결과 운송 도로면의 요철조건, 운송차종(중량), 운송속도에 따라 측정값에 차이가 있었다. 세부적으로 콘크리트 도로, 고속 주행일 때, 파워스펙트럼밀도(PSD) 값이 큰 것으로 분석되었고, 충격가속도는 소형 트럭이 가장 큰 값으로 분석되었다. 또한 측정자료를 바탕으로 랜덤진동시험기준을 제시하였다.

  • PDF

Optimization for Higher Sensitive Measurements of FET-type Sensors (FET센서 감도 향상 측정을 위한 최적화)

  • Sohn, Young-Soo
    • Applied Chemistry for Engineering
    • /
    • v.26 no.1
    • /
    • pp.116-119
    • /
    • 2015
  • Field-effect transistor (FET)-based ion or biosensors have been intensively studied so far. Among many measurement methods, the variation of the drain current can be induced when ions or biomolecules are interacted with sensing membranes located on the gate insulator of FET. One of typical FET-type sensors is an ion-sensitive field-effect transistor (ISFET) utilized in this study. In ISFET, the voltage is usually applied to the reference electrode instead of the gate voltage. Firstly, the voltage applied to the reference electrode versus the drain current was observed, and the steepest slope in this graph was found. Using this point, the optimized condition was established for the larger variation of the drain current in the saturated region in response to the variation of the input in the dynamic range.

A Study on the Measurement of Museum Exhibit's Color Change by Lighting (조명에 의한 박물관 전시물의 변색 측정에 관한 연구)

  • Kim, Hoon;Kim, Hong-Bum
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.10 no.5
    • /
    • pp.43-51
    • /
    • 1996
  • An appropriate lighting standard for the museum is needed to minimize the deterioration of the exhibits by the light. To obtain the basic data for the standard, a system to measure the color change of the artifacts as a function of the radiation energy frequency was constructed. Xenon lamp is used as a light source, and the light is irradiated to the samples through serveral cut-off filters. Measuring the colors of the samples under each filters, color change of the samples is estimated for each frequency ranges of radiation energy. As a result, natural dyes show severe color change in a short time, but traditional papers shows relatively small color change. Using measured results, color change due to other light sources can be calculated and this will be the base of the standard.

  • PDF

Field Applicability Assessment of Degradation Diagnosis System for Distribution Power Cables (배전케이블 열화진단 장치의 현장적용성 평가)

  • Lee, Jae-Bong;Kim, Dong-Myung;Song, Il-Keun;Kim, Ju-Yong;Kim, Suk-Chul
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07b
    • /
    • pp.1131-1134
    • /
    • 2003
  • 이 논문은 현재 국내에서 사용하고 있는 배전용 케이블 열화진단장치인 완화전류 측정장치의 진단기준 개선을 위한 것이다. 현재까지 사용되던 직류 고전압을 이용한 누설전류 측정법을 대체하기 위해 사용되는 완화전류 측정장치는 국내 배전선로에서 수년간 현장적용을 실시하여 많은 케이블을 교체하였다. 하지만 완화전류 측정을 통해 교체한 케이블의 상태에 대해서는 검증되지 않은 상태이므로 완화전류 측정을 통한 교체기준이 국내 케이블에 적절한지 확인할 필요가 있다. 이는 케이블 유지보수에 있어서 중요한 사항으로서 교체기준이 부적절할 경우 열화진단을 통한 고장방지 목적을 달성할 수 없거나 건전한 케이블을 교체하여 불필요한 예산을 낭비하는 원인이 된다. 본 논문에서는 현장운전중인 선로를 선택하고 열화된 케이블의 절연성능 향상을 위해 실리콘을 주입하였다. 그리고 실리콘 처리후 케이블의 운전시간에 따른 열화진단 결과와 케이블 절연파괴강도를 비교하여 진단장치의 신뢰성을 검증하고자 하였다. 이것은 1년 동안의 현장시험 결과를 정리한 것이다.

  • PDF