• Title/Summary/Keyword: 측정값

Search Result 14,436, Processing Time 0.037 seconds

Design and Error Verification of Intravenous Injection Detection System that Combines Load Cell and Gyro Sensor (로드셀과 자이로센서를 융합한 수액 감지 시스템 설계 및 오차 검증)

  • Kim, Seon-Chil
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.1
    • /
    • pp.127-132
    • /
    • 2021
  • The intravenous injection monitoring system used by medical institutions was developed to remotely provide patients with the amount of intravenous injected and the termination point of the injection. In order to measure the amount of intravenous injection input, the weight or flow rate of the level going out from the inside to outside of the intravenous injection can be observed with a measuring sensor. The criteria for devices that apply herein are accuracy and vigilance. In addition, it is compact and should be easy to use when installing intravenous injection on patients. In medical institutions, the accuracy of the measured values must be high, and economically inexpensive devices are required. In this study, low-cost small-weight-centered load cell sensors were applied, and algorithms were applied to reduce the artefact by external movement by converging with gyro sensors for accuracy of measurements. As a result, it was possible to reduce the error of measurement, thereby improving the accuracy of the intravenous injection monitoring measurement value.

Development of Wireless Healthcare System for Emergency Treatment (응급상황을 대비한 무선의료관리시스템 개발)

  • Park, Sung-Chul;Moon, Byung-Hyun;Lim, Byung-Hyun;Hwang, Bum-Suk;Choi, Sang-Min
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.14 no.5
    • /
    • pp.125-130
    • /
    • 2009
  • Today, the handicapped or old people require continuous care, but there are a lot of practical difficulties. In this paper, the system measuring health conditions of the handicapped or old people (pulse and temperature) is developed. If urgent health conditions occur, measurement values are delivered to doctors or close family members using SMS (Short Message Service) of cellular phone. In the developed system, Pulse rate is measured by sensing bloodstream using high luminance LED and CdS illumination sensors. Body temperature is also measured by contactless temperature sensor. Also, the measured values are transmitted to a server computer using Zigbee communications. Also, the measured values the average of measurements and the time are saved. The wireless healthcare system is designed to help the emergency for the handicapped and old people by using SMS.

Estimation Method of Predicted Time Series Data Based on Absolute Maximum Value (최대 절대값 기반 시계열 데이터 예측 모델 평가 기법)

  • Shin, Ki-Hoon;Kim, Chul;Nam, Sang-Hun;Park, Sung-Jae;Yoo, Sung-Soo
    • Journal of Energy Engineering
    • /
    • v.27 no.4
    • /
    • pp.103-110
    • /
    • 2018
  • In this paper, we introduce evaluation method of time series prediction model with new approach of Mean Absolute Percentage Error(hereafter MAPE) and Symmetric Mean Absolute Percentage Error(hereafter sMAPE). There are some problems using MAPE and sMAPE. First MAPE can't evaluate Zero observation of dataset. Moreover, when the observed value is very close to zero it evaluate heavier than other methods. Finally it evaluate different measure even same error between observations and predicted values. And sMAPE does different evaluations are made depending on whether the same error value is over-predicted or under-predicted. And it has different measurement according to the each sign, even if error is the same distance. These problems were solved by Maximum Mean Absolute Percentage Error(hereafter mMAPE). we used the absolute maximum of observed value as denominator instead of the observed value in MAPE, when the value is less than 1, removed denominator then solved the problem that the zero value is not defined. and were able to prevent heavier measurement problem. Also, if the absolute maximum of observed value is greater than 1, the evaluation values of mMAPE were compared with those of the other evaluations. With Beijing PM2.5 temperature data and our simulation data, we compared the evaluation values of mMAPE with other evaluations. And we proved that mMAPE can solve the problems that we mentioned.

Evaluation of the Reliability of Salivary Testing Instrument (타액검사기의 신뢰도 평가)

  • Han, Keumah;Lee, Joonhaeng
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.45 no.3
    • /
    • pp.363-369
    • /
    • 2018
  • A salivary testing instrument has an advantage that the method is simple and can be performed in a short time. However, it is necessary to verify the factors that affect the reliability of the result, because the device is easy to use and even saliva collection is simple. The aim of this study was to compare the difference of the test results according to the measurement time in order to analyze the time factor of the external variable among the factors that may affect the measurement results of the salivary testing instrument. The relationship between the measured values of the salivary testing instrument to identify the internal variables was analyzed. Saliva was collected from 20 randomly selected patients regardless of age, sex, or diseases. The mean age was 46.6 years, 10 males and 10 females. The saliva collected was directly measured with the salivary testing instrument as group I. The saliva samples were placed in air in a paper cup for 10 minutes, and then measured as group III. Then group I was remeasured after 30 minutes and assigned as group II. Group III was remeasured after 30 minutes and called as group IV. As a result, all of the cariogenic bacteria, acidity, buffer capacity, blood, leukocyte, protein and ammonia, except buffer capacity, showed statistically significant changes in group II and IV. This means that the reliability of the test results is poor if the measurement time is not observed. Cariogenic bacteria were correlated with leukocyte and protein, buffer capacity was related to acidity, protein, and protein was related to buffer capacity and leukocyte. In conclusion, the result according to the measurement time as the external variable was different, which means that time must be strictly monitored when testing saliva. It is also necessary to take into account the relevance of the correlations between the internal variables and the clinical data.

Development of a Direct Evaluation Method to Measure the Rancidity of Yeonhaeju Soybean (Bazaz) Powders during Storage via the Fluorescence Spectrum Test (Fluorescence spectrum test를 이용한 연해주 대두(Bazaz) 분말의 저장 중 산패도 측정법 개발)

  • Uhm, Joo-Tae;Yoon, Won-Byong
    • Food Science and Preservation
    • /
    • v.19 no.5
    • /
    • pp.639-644
    • /
    • 2012
  • The rancidity of soybean (Glycine max L.) from Yeonhaeju, called "Bazaz", in powder forms was evaluated through a fluorescence spectrum test (FST). The results from the FST were validated by comparing the TBA and acid values. Soybean powders were stored in 25, and $90^{\circ}C$ for 20 days. The maximum excitation and maximum emission of fluorescent compounds generated from the soybean powder during storage were observed at the 360 nm and 430-440 nm wavelengths, respectively. The mean particle size of soybean powder was maintained at $40{\mu}m$ to avoid the dependence of the reaction area during measurement. According to the FST results, lipid oxidation did not actively progress during storage at $25^{\circ}C$. The fluorescence intensity (FI) from FST on the first day of storage was not significantly different from that on the last day of storage (day 20; p < 0.05), but the FI dramatically increased at $90^{\circ}C$. A smooth increase was observed in the initial stage; then, after 11 days of storage, the FI value increased by nearly 100% compared to that on the first day. The FI values were compared with TBA and acid values that were measured under the same storage conditions. All the values at $25^{\circ}C$ showed similar patterns during storage, but at $90^{\circ}C$, the FI and acid values showed similar patterns but the TBA decreased after reaching the maximum values on storage day 12. The results demonstrated that FST may be useful for measuring the rancidity of the powder form of soybean because it does not require extraction to measure the rancidity.

A Study on the Characteristics of CdS Thin Film by Annealing Time Change (열처리시간 변화에 의한 CdS 박막 특성에 관한연구)

  • Chung, Jae-Pil;Park, Jung-cheul
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.14 no.5
    • /
    • pp.438-443
    • /
    • 2021
  • This paper uses a multiplex deposition sputter system and aims to improve transmittance and reduce production costs by depositing a CdS thin film on an ITO glass substrate. When manufacturing CdS thin films, we wanted to find excellent conditions when manufacturing solar cells by changing heat treatment time. It was observed that thickness and sheet resistance were not significantly different depending on heat treatment time changes. The specific resistance was measured from a minimum of 6.68 to a maximum of 6.98. When the heat treatment time was more than 20 minutes, the transmittance was measured to be more than 75%. When the heat treatment time was 10 minutes, the bandgap was 3.665 eV and more than 20 minutes was 3.713 eV, which was measured as the same result. The XRD analysis showed that the structure of CdS was hexagonal and only CdS thin films were deposited without any other impurities. The result of calculating the FWHM was a maximum of 0.142 when the heat treatment time was 20 minutes, and a minimum of 0.133 when the heat treatment time was 40 minutes, so there was no significant difference in the FWHM when the heat treatment time was changed. The particle size was measured at 11.65 Å when the heat treatment time was 40 minutes, and at 10.93 Å when the heat treatment time was 20 minutes.

Relationship of Bone Mineral Density Measured by Ultrasound Bone Densitometry and Body Composition or Backmuscle Strength (초음파방식으로 측정된 골밀도와 신체조성 및 배근력의 관계)

  • Lee, Won-Jeong
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.5
    • /
    • pp.721-728
    • /
    • 2019
  • The purpose of this study was to evaluate the relationship between bone mineral density (BMD) and body composition (BC) or backmuscle strength (BS). Sixty-one participants were measured by BMD using ultrasound bone densitometry and Inbody for BC (i.e., SLM=Soft lean mass, SMM=Skeletal muscle mass, FS=Fitness score. et al.), BS after self-questionnaire for life cycle. This study was performed after approving Institutional Review Board and obtaining the informed concent from all participants. Participants was divided into two group by BMD T-score; $T-score{\geq}-1.0$, T-score<-1.0. Statistical analysis was performed by using SPSS ver. 22.0(USA), Spearma test for correlation between BMD and BC or BS. BMD or SLM, BS was increased with increasing physical activity or body mass index. SMM or SMM, FS of BMD $T-score{\geq}-1.0$ group was higher than that of T-score <-1.0 group as well as BS(p>0.05). BMD T-score was correlated positively with SLM(r= 0.424) or SMM(r= 0.431) in men, as well as in women(p<0.05). BS was correlated positively with SLM or SMM, FS. BS was significantly positive correlated with BMD in women group (r= 0.591, p= 0.001), but not in men group. We concluded that BMD is the relationship with SLM or SMM, as well as BS in women.

Estimation of Ultimate Lateral Resistances of Piles Using CPT Cone Resistance in Sand (사질토지반에서 콘관입저항치 $q_c$에 의한 단말뚝의 극한수평단위지지력 평가)

  • Kim, Min-Kee;Kyung, Doo-Hyun;Hong, Jung-Moo;Lee, Jun-Hwan
    • Journal of the Korean Geotechnical Society
    • /
    • v.24 no.11
    • /
    • pp.71-77
    • /
    • 2008
  • In this study, CPT-based methodology for estimating the ultimate lateral resistance, $p_u$, is proposed and verified for lateral loaded piles in sandy soil. Preexistent methods estimating the ultimate lateral resistance, $p_u$, and the ultimate lateral capacity, $H_u$, of pile have been based on the vertical effective stress, relative density, and the coefficient of lateral earth pressure. Similarly, cone resistance $q_c$ in pure sandy soil is expressed by those essential factors. As correlation between $p_u$ and $q_c$ are normalized with average effective stress ${\sigma}_m$, estimation methodology for the lateral loaded pile of $p_u$ in sandy soil is proposed. The method is verified by calibration chamber test results in pure sand. The standard derivation of estimated $p_u$ is 0.279, and COV (Coefficient Of Variation) of estimated $p_u$ is 0.272. These results showed that the estimated pus by the method are analogous with the measured $p_us$ in calibration chamber test.

Case study on the Prediction of Underwater Sound Pressure Level by Blasting (발파에 의한 수중음압레벨 예측 사례연구)

  • Park, Jeong-Il;Kang, Choo-Won;Noh, Young-Bae;Ko, Chin-Surk
    • Explosives and Blasting
    • /
    • v.29 no.2
    • /
    • pp.81-88
    • /
    • 2011
  • Most of the blast pollution that causes complaints is noise and vibration. Hence, special attentions need to be paid to controlling the underwater noise in designing blasting for those areas. This study estimated underwater sound pressure using distance from blasting and charge per delay and underwater sound pressure level using the underwater sound pressure. To identify the validity of the estimated value, the study demonstrated the results at other areas and compared actual results with estimated results.

Performance Analysis of Terrain Referenced Navigation Syst-em Using Topography Characteristic points (지형의 특성점을 이용한 지형참조항법 시스템의 성능 분석)

  • Lee, Bo-Mi;Kwon, Jay-Hyoun
    • Proceedings of the Korean Association of Geographic Inforamtion Studies Conference
    • /
    • 2010.09a
    • /
    • pp.126-128
    • /
    • 2010
  • 지형 참조 항법(TRN, Terrain reference navigation)은 항체에 탑재된 지형 데이터베이스와 센서로부터 측정된 고도값을 대조하여 항체의 위치를 알아내는 것으로, GPS/INS 결합항법 시스템의 대체 항법으로 많이 알려져 있다. 지형의 형태에 따라서 시스템의 정확도와 안정성이 달라지기 때문에 특정적인 지형 정보를 이용하여 지형 데이터베이스와 대조하는 과정이 매우 중요하다. 따라서 본 논문에서는 센서 측정값과 지형 데이터베이스 상의 값에서 지형의 특성적 변화가 발생하는 지점인 Model Key Point를 2D Douglas-Peucker 알고리즘을 이용하여 추출하고 이를 항법 알고리즘에 적용하여 시뮬레이션 하였다. 그 결과 오차가 발산하지 않고 수십m 급의 항법 정밀도를 얻을 수 있었다.

  • PDF