• Title/Summary/Keyword: 측모 사진

Search Result 158, Processing Time 0.028 seconds

Comparison of analysis of the lateral cephalogram and analysis of lateral facial photograph (측모 두부방사선계측사진 분석과 측모 사진 분석의 비교)

  • Lim, Sung-Hoon;Cho, Ju-Young;Choi, Gab-Lim;Kim, Kwang-Won
    • The korean journal of orthodontics
    • /
    • v.36 no.1 s.114
    • /
    • pp.74-83
    • /
    • 2006
  • Analysis of lateral cephalometric radiograph (cephalogram) has been used routinely to evaluate skeletal and dental relationships, but analysis of the lateral facial photograph has not been used frequently for evaluation of skeletal relationships. As concerns about harm of X-ray irradiation increases, this study was planned to evaluate the possibility of substituting analysis of the lateral cephalogram with analysis of the lateral facial photograph by comparing these two analyses. According to the ANB values from cephalometric analysis, subjects were divided into three groups: Class I malocclusion group (n=32). Class II malocclusion group (n=32), and Class III malocclusion group (n=31). After measurements of angles indicating horizontal and vertical relationships of the maxilla and mandible on the lateral cephalograms and photographs, differences between Class I, II and III groups were evaluated. To evaluate the similarity between two similar values in the cephalograms and photographs, t-test using standardized variable Z and correlation analysis were performed in the Class I malocclusion group. The results showed that 1) SnN'Pg' on the photograph can be used to evaluate the antero-posterior relationship of the maxilla and mandible (ANB), 2) N'-Sn/Sn-Pg' on the photograph can be used to evaluate facial convexity (NA/APg), 3) Sn-Tra-Me' on the photograph can be used as a measurement similar to FMA. In conclusion, partly substituting lateral cephalogram analysis with lateral facial photograph analysis was possible in the evaluation of the maxilla and mandible.

A Cephalometric Analysis on Esthetic Facial Soft Tissue of Korean Young Adult Female (한국인 젊은 여성의 심미적인 안면 연조직 형태에 관한 두부 X-선 계측학적 연구)

  • WOO, Je-Kyung;KWON, Oh-Won;SUNG, Jae-Hyun
    • The korean journal of orthodontics
    • /
    • v.27 no.2
    • /
    • pp.245-258
    • /
    • 1997
  • Cephalometric radiographs, frontal photographs and profile silhouette phogographs of 68 young adult female who were model or were recommended to have esthetic face were used in this study. 7 Students in department of Art of Kyungpook national university and 15 orthodontists estimated profile slides which were made of 3 Profile silhouettes in parallel with FH plane. Profile silhouettes were made of soft tissue profile line of cephalometric radiograph. Only orthodontists estimated frontal photographs. Students and orthodontists score 9 in excellent case, score 7 in good case, score 5 in average case, score 3 in poor case. Correlation analysis between orthodontists' esthetic concept and Artists' esthetic concept, between frontal view esthetics and profile view esthetics which estimated by orthotontists, between profile view esthetics and profile measurements which consisted of measurements of 38 female who were scored above 5 mean score in profile silhouette by orthodontists were done. And the finding in this study indicated the following 1. Correlation between orthodontists' esthetic concept and Artists' esthetic concept in profile silhouette was significant (r=0.67,P=0.0001). 2. Correlation between frontal view esthetics and profile view esthetics which estimated by orthodontist was significant (r=0.26,P=0.0381). 3. Measurements which had significant correlation between profile measurements and profile view esthetics wer Na-Pog, to N', BNV to Pog', BNV/B' -Pog', Ls-Li-Pog', Li-B'-Pog' Z angle(P<0.05). 4 Mean and standard deviation of profile measurements of 38 female were obtained.

  • PDF

The reliability of the cephalogram generated from cone-beam CT (Cone-beam CT로부터 제작된 측모 두부계측방사선사진의 정확도 평가)

  • Kang, Ji-Young;Kim, Kwang-Won;Lim, Sung-Hoon
    • The korean journal of orthodontics
    • /
    • v.37 no.6
    • /
    • pp.391-399
    • /
    • 2007
  • Three-dimensional approaches for the diagnosis and analysis of the dentofacial area are becoming more popular in accordance with the development of cone-beam CT (CBCT). The purposes of this study were to evaluate the reliability of cephalometric measurements of lateral cephalograms generated from a CBCT image by making comparisons with the traditional digital lateral cephalogram, and to evaluate the possibility of the clinical application of CBCT generated cephalogram images. Methods: Twenty patients whose external auditory meatus could be identified in the CBCT image were selected, and both CBCT and digital cephalograms were taken. Differences between the measurements of both cephalograms were tested by paired t-test. Results: Among the 22 measurements used, only U1-FH, Mx6 to PTV, and maxillomandibular difference showed statistically significant differences between the CBCT generated cephalogram and the digital cephalogram. Conclusions: The results suggest that the CBCT generated cephalogram can be used for some cephalometric measurements not requiring porion, PTV, condylion as a landmark (SNA, SNB, U1 to SN, IMPA, interincisal angle, etc.).

REAPPRAISAL OF SOFT TISSUE PREDICTION IN ORTHOGNATHIC SURGERY FOR MANDIBULAR PROGNATHISM (외과적 악교절수술에 있어서 측모연조직예측의 재평가에 대한 연구)

  • Chung, Moo-Hyeok;Nam, Il-Woo
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.13 no.1
    • /
    • pp.37-43
    • /
    • 1991
  • Cephalometric prediction tracing is the preoperative double checking procedure which can predict bony and soft tissue change. Soft tissue profile prediction is routinely performed according to the known ratios of the soft to hard tissue movement which can vary considerably in each individual. Besides interindividual variation of the ratios of the soft to hard tissue change, actual results of the postoperative soft tissue profile can reflect other important modifying factors if it is compared with prediction tracing used. The purpose of this study is to compare soft tissue prediction tracing used with postoperative tracing and to find intervening modifying factor via serial tracing. Review of 30 prediction tracing showed that the most important factor contributing to prodiction tracing inaccuracy was the skeletal and dental relapse. And, some factors which may be responsible for prediction tracing inaccuracy were discussed.

  • PDF

The comparative study of three-dimensional cephalograms to actual models and conventional lateral cephalograms in linear and angular measurements (3차원 두부방사선규격사진의 정확성에 관한 연구 -실제 계측 및 측모 두부방사선 규격사진 계측과의 비교-)

  • BAE, Gi-Sun;Park, Soo-Byung;Son, Woo-Sung
    • The korean journal of orthodontics
    • /
    • v.27 no.1
    • /
    • pp.129-140
    • /
    • 1997
  • Conventional cephalometrics have inherent errors because their evaluation is performed in two-dimension for threedimensional object. To compensate these errors, three-dimensional cephalograms - derivation of three-dimensional data from conventional lateral and postero-anterior cephalograms - were developed. In this study, the accuracy and precision of three dimensional cephalograms were determined by means of 10 linear and 12 angular measurements on 36 acrylic skull models and by the comparison of conventional lateral cephalograms. The results were as follows 1. Mean difference between three-dimensional cephalograms and actual models in linear measurements was $0.94{\pm}0.62mm$ and mean rate of magnification of three-dimensional cephalograms was $100.31{\pm}0.91%$. There were no statistically significant differences between three-dimensional cephalograms and actual models in linear measurements(${\alpha}=0.1$). 2. Mean difference between conventional lateral cephalograms and actual models in linear measurements was $6.44{\pm}1.48mm$ and mean rate of magnification of lateral cephalograms was $106.99{\pm}1.45%$. There were statistically significant differences between lateral cephalograms and actual models in linear measurements(P<0.005). 3. Mean difference between three-dimensional cephalograms and actual models in angular measurements was $1.22{\pm}0.82^{\circ}$ and mean rate of magnification of three-dimensional cephalograms was $105.71{\pm}12.07%$. There were no statistically significant differences between three-dimensional cephalograms and actual models in angular measurements(${\alpha}=0.1$). 4. Mean difference between conventional lateral cephalograms and actual models in angular measurements was $1.70{\pm}0.94^{\circ}$ and mean rate of magnification of lateral cephalograms was $106.35{\pm}15.70%$. There were no statistically significant differences between lateral cephalograms and actual models in angular measurements(${\alpha}=0.1$). There were similarity between three-dimensional and lateral cephalograms in angular measurements.

  • PDF

THREE DIMENSIONAL ANALYSIS OF MAXILLOFACIAL STRUCTURE BY FRONTAL AND LATERAL CEPHALOGRAM (두부 방사선 규격사진을 이용한 악안면 구조의 3차원적 분석법)

  • Kwon, Kui-Young;Lee, Sang-Han;Kwon, Tae-Geon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.21 no.2
    • /
    • pp.174-188
    • /
    • 1999
  • The purpose of this study is to evaluate the precision and accuracy of a three dimensional cephalogram constructed by using the frontal and lateral cephalogram of twelve human dry skulls. After achieving the three dimensional image reconstruction program, we tried to apply this program to two dentofacial deformity patients. 1. Conventional nasion relator in cephalostat was used to reproduce the same head position for the same dry skull. The mean difference of the three dimensional cephalogram for the same dry skull was $0.34{\pm}0.33mm$. Closeness of repeated measures to each skull reveals the precision of this method for the three dimensional cephalogram. 2. Concerning the accuracy, the mean difference between the three dimensional reconstruction data and actual lineal measurements was $1.47{\pm}1.45mm$ and the mean magnification ratio was $100.24{\pm}4.68%$. This Diffrerence is attributed mainly to the ill defined cephalometric landmarks, not to the positional change of the dry skull. 3. Cephalometric measurement of lateral and frontal radiographs had no consecutive magnification ratio because of the different focus-object distance. The mean difference between the frontal and lateral cephalogram to the actual lineal measurements was $4.72{\pm}2.01mm$ and $-5.22{\pm}3.36mm$. Vertical measurements were slightly more accurate than horizontal measurements. 4. Applying to the actual patient analysis, it is recommendable to use this program for analyzing the asymmetry or spatial change after operation. The orthodontic bracket would be a favorable cephalometric landmark for constructing the three dimensional images.

  • PDF

Three-dimensional CT image study on the correction of gonial angle width enlarged on frontal cephalogram (정모두부방사선사진에서 하악골 우각부 영상확대 및 이의 보정에 관한 3차원 CT영상 연구)

  • Hwang, Hyeon-Shik;Eun, Chun-Sun;Hwang, Chung Hyon;Lim, Hoi-Jeong
    • The korean journal of orthodontics
    • /
    • v.35 no.4 s.111
    • /
    • pp.251-261
    • /
    • 2005
  • Enlargement is an inherent property of X-rays which occurs when straight hues diverse from small a focal spot. The purpose of the present study was to evaluate the validity of the correction of gonial angle width enlarged on frontal cephalogram, using frontal and lateral cephalograms taken orthogonally from each other. In 40 adult individuals, frontal and lateral cephalograms were taken at a $90^{\circ}$ angle using the Head Posture Aligner. The angle width was measured on the frontal cephalogram and subsequently. the corrected angle width was calculated using the magnification rate of two cephalograms. Measured and corrected angle widths were compared with the measurement from the 3D CT image. The measurement or the frontal cephalogram showed a 9.10mm of enlargement on average ranging from 7.92 to 11.31mm. Corrected angle width measurement showed a 0.14mm difference with the 3D CT image measurement, which was not statistically significant. The results of the study indicate that actual au91e width can be approached through calculation using frontal and lateral cephalograms taken orthogonally with the help of the Head Posture Aligner The study also showed that the magnitude of correction error did not show a significant correlation with the amount of menton deviation, and it suggests that the present correction method is valid even in individuals with severe facial asymmetry.

Subjective Evaluation about Ideal Position of the Subnasale on Lateral Photos (측모 사진상에서 Subnasale의 이상적인 위치에 관한 주관적 평가)

  • Kim, Yi-Dong;Chung, Dong-Hwa;Cha, Kyung-Suk;Lee, Jin-Woo;Lee, Sang-Min
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.4
    • /
    • pp.347-358
    • /
    • 2013
  • When analyzing soft tissue of the profile, Subnasale is often used as an important reference point. But there are few studies on the ideal position of the Subnasale. Therefore, the purpose of this study is to present an objective reference of the esthetic face relating to the change of Subnasale position in Koreans' profile, and also to determine whether there is concordance between professionals and laypersons in their perception of facial attractiveness. The one determined as appropriate profile portion by experts of pictures taken in women in 20s was selected. The photograph was modified changing the Subnasale anteroposteriorly on the plane perpendicular to the true vertical line, while maintaining the nasolabial angle. The photographs were presented to a group of professionals (9 orthodontists) and 126 laypersons, who were asked to assess the facial attractiveness of the photographs on a VAS independently. The conclusion was obtained. 1. The ideal position of the Subnasale is when the ratio of the distance Lateral canthus~Subnasale : Subnasale~Pronasale is 1.769 : 1. 2. The ideal degrees between the true vertical line passing through Nasion and Subnasale is $5.5^{\circ}$ 3. The professionals recognized every change in the ratio, but the laypersons couldn't differentiate between the change from 1.571 : 1 to 1.769 : 1.