• Title/Summary/Keyword: 측모두부 영상

Search Result 11, Processing Time 0.019 seconds

The Simple Regression Model of Gonial Angles : Comparison between Panoramic Radiographs and Lateral Cephalograms (Gonial Angle의 단순 회귀 모델: 파노라마 영상과 측모두부 영상간의 비교)

  • Park, Sung-Hee;Kim, Young-Jae;Lee, Sang-Hoon;Kim, Chong-Chul;Jang, Ki-Taeg
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.44 no.2
    • /
    • pp.129-137
    • /
    • 2017
  • The aim of this study was to enhancing the panoramic radiograph's clinical use for assessing mandibular measurements and formulating a function of those measurements from panoramic radiographs and lateral cephalograms in children. The panoramic radiographs and lateral cephalograms of 99 former orthodontic patients with skeletal class III malocclusion were selected. In each radiograph, gonial angles, ramus heights, and distance between lower incisors and symphysis were measured. The values of the studied parameters were compared by paired t-test, Pearson's correlation test and regression analysis. The mean value of the gonial angle in panoramic radiographs was $125.49^{\circ}$, and the value in lateral cephalograms was $127.50^{\circ}$. The Pearson's correlation coefficient (${\rho}$) between mean values of gonial angle in each radiograph was 0.945 (p < 0.001). The relationship between the gonial angle measurements obtained from each radiographs was represented as 'Gonial angle (Lateral cephalograms) = 0.920 ${\times}$ Average gonial angle (Panoramic radiographs) + 12.072' in the linear function. The coefficients of ramus heights, and distance between lower incisors and symphysis portrayed weaker correlations than gonial angles. A panoramic radiograph could be used to determine the gonial angle as accurately as a lateral cephalogram, and each gonial angle showed a strong positive relation. A panoramic radiograph is a useful tool for examining vertical growth pattern of patients, as well as a lateral cephalogram.

THREE DIMENSIONAL ANALYSIS OF MAXILLOFACIAL STRUCTURE BY FRONTAL AND LATERAL CEPHALOGRAM (두부 방사선 규격사진을 이용한 악안면 구조의 3차원적 분석법)

  • Kwon, Kui-Young;Lee, Sang-Han;Kwon, Tae-Geon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.21 no.2
    • /
    • pp.174-188
    • /
    • 1999
  • The purpose of this study is to evaluate the precision and accuracy of a three dimensional cephalogram constructed by using the frontal and lateral cephalogram of twelve human dry skulls. After achieving the three dimensional image reconstruction program, we tried to apply this program to two dentofacial deformity patients. 1. Conventional nasion relator in cephalostat was used to reproduce the same head position for the same dry skull. The mean difference of the three dimensional cephalogram for the same dry skull was $0.34{\pm}0.33mm$. Closeness of repeated measures to each skull reveals the precision of this method for the three dimensional cephalogram. 2. Concerning the accuracy, the mean difference between the three dimensional reconstruction data and actual lineal measurements was $1.47{\pm}1.45mm$ and the mean magnification ratio was $100.24{\pm}4.68%$. This Diffrerence is attributed mainly to the ill defined cephalometric landmarks, not to the positional change of the dry skull. 3. Cephalometric measurement of lateral and frontal radiographs had no consecutive magnification ratio because of the different focus-object distance. The mean difference between the frontal and lateral cephalogram to the actual lineal measurements was $4.72{\pm}2.01mm$ and $-5.22{\pm}3.36mm$. Vertical measurements were slightly more accurate than horizontal measurements. 4. Applying to the actual patient analysis, it is recommendable to use this program for analyzing the asymmetry or spatial change after operation. The orthodontic bracket would be a favorable cephalometric landmark for constructing the three dimensional images.

  • PDF

Three-dimensional CT image study on the correction of gonial angle width enlarged on frontal cephalogram (정모두부방사선사진에서 하악골 우각부 영상확대 및 이의 보정에 관한 3차원 CT영상 연구)

  • Hwang, Hyeon-Shik;Eun, Chun-Sun;Hwang, Chung Hyon;Lim, Hoi-Jeong
    • The korean journal of orthodontics
    • /
    • v.35 no.4 s.111
    • /
    • pp.251-261
    • /
    • 2005
  • Enlargement is an inherent property of X-rays which occurs when straight hues diverse from small a focal spot. The purpose of the present study was to evaluate the validity of the correction of gonial angle width enlarged on frontal cephalogram, using frontal and lateral cephalograms taken orthogonally from each other. In 40 adult individuals, frontal and lateral cephalograms were taken at a $90^{\circ}$ angle using the Head Posture Aligner. The angle width was measured on the frontal cephalogram and subsequently. the corrected angle width was calculated using the magnification rate of two cephalograms. Measured and corrected angle widths were compared with the measurement from the 3D CT image. The measurement or the frontal cephalogram showed a 9.10mm of enlargement on average ranging from 7.92 to 11.31mm. Corrected angle width measurement showed a 0.14mm difference with the 3D CT image measurement, which was not statistically significant. The results of the study indicate that actual au91e width can be approached through calculation using frontal and lateral cephalograms taken orthogonally with the help of the Head Posture Aligner The study also showed that the magnitude of correction error did not show a significant correlation with the amount of menton deviation, and it suggests that the present correction method is valid even in individuals with severe facial asymmetry.

EVALUATION OF THE REPRODUCIBILITY IN CEPHALOGRAPHY USING ROENTGENOCEPHALOMETRICS AND PHOTOGRAPHIC SUBTRACTION (두부방사선 계측과 Photographic subtraction을 이용한 측모 두부방사선 규격사진의 재현성에 관한 연구)

  • Jeon Seon-Doo;Nha Kyung-Soo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.24 no.2
    • /
    • pp.347-359
    • /
    • 1994
  • The reproducibility of cephalography in repeated exposures were studied by tracing and photographic subtraction. The materials consisted of 50 pairs of 'same day' radiograph taken under identical conditions. The evaluation included skull, cervical column, hyoid bone, pharynx, tongue, soft tissue profile resulting 43 items in tracing, and 19 items in photographic subtraction. The results obtained from the differences between each pair were as follows: 1. The means and standard deviations by tracing of skull, cervical column, hyoid bone, pharynx, tongue, soft tissue profile were 0.34±0.62㎜, 1.02±1.59㎜, 1.37±1.78㎜, 0.55±1.16㎜, 0.51±1.51㎜, 0.15±0.3㎜ each. 2. The means and standard deviations by photographic subtraction of skull, cervical column, hyoid bone, pharynx, tongue were 0.09±0.35㎜, 0.70±0.95㎜, 1.22±1.33㎜, 0.53±0.86㎜, 0.27±0.41㎜ each.

  • PDF

A study on the accuracy of profile change Prediction by video imaging (Power Ceph $^{\circledR}Ver$ 3.3) in Class III two jaw surgery patients (골격성 III급 부정교합을 가진 양악 수술 환자의 술후 측모 예측을 위한 Video imaging (Power $Ceph^{\circledR}$ Ver 3.3)의 정확도에 관한 연구)

  • Kwon, Mi-Jeong;Baik, Hyoung-Seon;Lee, Won You
    • The korean journal of orthodontics
    • /
    • v.29 no.3 s.74
    • /
    • pp.285-301
    • /
    • 1999
  • There is a need for more accurate prediction in surgical orthodontic treatment. Video imaging is an important technology in planning orthognathic surgery and educating patients about the esthetic results after treatment. Preoperative and postoperative lateral cephalogram of 30 patients who had one piece Le Fort I osteotomy advancement and mandibular set back by bilateral intraoral vertical ramal osteotomy with or without genioplasty were used in this study. The computer generated soft tissue line drawing prediction were compared with the actual postoperative cephalograms .The results are as follows. 1. 14 variables showed Statistically significant differences from 24 variables between computer predicted profile and post operative profile 2. Most of the differences were found in the maxilla-related soft tissue landmarks. 3. The predicted results were more accurate in the groups who had small amount of mandibular set back. 4. The predicted results were more accurate in the groups who had no genioplasty. Most of these differences were within 2mm ranges. Therefore profile change prediction by video imaging could be considered clinically acceptable.

  • PDF

Comparative Analysis of Accuracy between Computerized Tomography and Cephalogram for 3-Dimensional Measurement of Maxillofacial Structure (악안면 3차원 계측시 컴퓨터 단층촬영과 두부 방사선 규격사진의 정확성 비교 분석)

  • Paek, Jong-Su;Song, Jae-Chul;Lee, Hee-Kyung
    • Journal of Yeungnam Medical Science
    • /
    • v.18 no.1
    • /
    • pp.123-137
    • /
    • 2001
  • Background: The purpose of this study is to evaluate the accuracy of measurements obtained from 3-dimensional computerized tomography and 3-dimensional cephalogram constructed by using the frontal and lateral cephalogram of six human dry skulls. Materials and Methods: After CT scans and each cephalograms were taken, 3-dimensional coordinates (X, Y, Z) of landmarks were obtained using computer programs. In this study, the accuracy of both methods were determined by means of 14 linear measurements compare with caliper measurements. Results: The standard deviation of landmarks of 3-dimensional CT and 3-dimensional cephalogram were 0.23 mm, and 0.30 mm in X axis, 0.27 mm and 0.25 mm in Y axis, and 0.27 mm and 0.31 mm in Z axis. In both methods, the standard deviation were less than 0.5 mm in all landmarks, and the most of landmarks showed less than 1 mm in range. Concerning the accuracy, the mean difference between 3-dimensional CT and manual measurements was 0.33 mm, and 1.13 mm between 3-dimensional cephalogram and manual measurements. The distance between RGo and LGo showed the largest difference (2.03 mm). There were highly significant, and large correlation with manual measurements in both methods (p<0.01). Conclusion: It is concluded that closeness of repeated measures to each skulls reveal the precision of both methods. Computerized tomography and cephalogram for 3-dimensional measurement of maxillofacial structure are equivalent in quality to caliper measurements.

  • PDF

COMPARISONS OF MEASUREMENTS OBTAINED FROM LATERAL CEPHALOMETRIC RADIOGRAPHS AND DIGIGRAPHS OF DOLPHIN IMAGING SYSTEM (측모 두부 방사선사진과 컴퓨터 영상사진 (Dolphin Imaging System)의 계측치 에 관한 비교)

  • Park, Hae-Joon;Park, Young-Chel
    • The korean journal of orthodontics
    • /
    • v.24 no.3 s.46
    • /
    • pp.521-534
    • /
    • 1994
  • The purpose of this study was to compare the differences in measurements between cephalometric radiographs and digigraphs of Dolphin Imaging System. 26 Korean adult male and 24 adult female with normal occlusion were selected. For each subject lateral cephalogram was taken. Digitizing with Digigraph Work Station of Dolphin in System. was performed as well. 50 tracings and 50 digigraphs were analyzed with Yonsei, Ricketts, Burstone analyses. The comparable measurements between tracing group and digigraph group were statistically analyzed. The results were as follows: 1. 13 of 64 comparable measurements did not show any statistically significant difference (P>0.05) between tracing group and digigraph group. 2. Three of the measurements with FH plane as a reference plane did not show any statistically insignificant difference. All measurement with SN plane as a reference plane showed statistically significant difference(p<0.05). 3. The measurements which showhed no statistically significant difference were mostly short distance linear measurements while most of the angular measurements showed statistically significant difference(p<0.05).

  • PDF

ERRORS IN DIGITIZED LATERAL CEPHALOMETRIC RADIOGRAPHY (계수 영상화된 측모 두부방사선 규격사진의 계측오차)

  • Jean Seon-Doo;Cho Bong-Hae;Nah Kunng-Soo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.27 no.2
    • /
    • pp.105-116
    • /
    • 1997
  • The purpose of this study is to evaluate the cephalometric reproducibility in digitized cephalometric radiography by comparing the measurement errors between the remeasured and retaken conventional and digitized lateral cephalometric radiography. The mean of the differences and error percentage of each cephalometric measurement were obtained using 96 lateral cephalometric radiography from 48 patients between the age of 11 and 13. The results were as follows; 1. The repeated measurement group of conventional radiography showed least amount of mean differences while those of the retaken measurement group of digitized image showed largest amount of mean differences in every measurement. 2. The measurements which showed statistically significant difference between the conventional radiography and digitized image were S-Go, Ar-Go, S-Ar-Go and S-sN-sNT in repeated measurement group. 3. The measurements which showed statistically significant difference between the repeated and retaken measurement groups were N-S-Ar, MP-Ll and S-sN-sPog in conventional radiography and S-N, Go-Me and N-A in digitized Image. 4. Large amount of error percentage was shown at A-N-B and N-A in retaken measurement group of conventional radiography and N-S-Ba and A-N-B in retaken measurement group of digitized image. 5. The amount of error percentage at Ar-Go and N-S- Ar in retaken measurement group of conventional radiography and S-N, N-A, S-N-B and N-S-Ba in retaken measurement group of digitized image was more than double than those from remeasured groups.

  • PDF

A ROENTGENOCEPHALOMETRIC STUDY FOR THE ACCEPTABLE PROFILE IN KOREAN ADULTS (한국성인의 측모에 관한 두부방사선학적 연구)

  • Lee You Dong;Lee Sang Rae
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.20 no.1
    • /
    • pp.19-27
    • /
    • 1990
  • The primary objective of this study was to analyze the hard and soft tissue profile and comparison of the both sexes in Korean adults using roentgenocephalometry. The subjects were 122 males and 116 females from 18 to 22 years of age selected on the basis of their excellent occlusion and harmonious profile. It was an investigation about the interrelationships in the angles which consisted of Frankfort horizontal plane (FH plane), Sella Nasion plane (SN plane), Nasal floor plane (NF plane) and Mandibular plane (Md plane) as reference planes, and of the axial inclinations of the upper anterior tooth to Nasal floor plane (NF Plane) and of the lower anterior tooth to Mandibular plane (Md Plane). Among the 14 categories estabilishied on the soft tissue land marks, the 6 categories were studied for the relationship to Frankfort horizontal plane (FH Plane), and the 8 categories were studied for the soft tissue contour. The results were as follows: 1. Among 8 measured angles in the hard tissue, the angle of FH-Md, NF-Md and SN-Md were greater in females than in males. 2. The axial inclinations of the anterior teeth to NF Plane and Md plane were slightly greater in males than In females. 3. Among 14 measured angles in the soft tissue, the angles of G-Sn-P and E-Pog-Sn were greater in males, and FH-G-Sn, GㆍSn-Sn. Pog and Pog-Sn-P were greater in females. 4. In males, the variability of measured values in both lips region were high.

  • PDF

A STUDY ON THE CHANCES OF THE SOFT TISSUE PROFILE FOLLOWING ORTHODONTIC TREATMENT BY DIGITAL SUBTRACTION METHOD (교정치료에 따른 측모 연조직의 변화에 관한 계수공제 영상측정법적 연구)

  • Cho, Won-Tak;Yu, Dong-Hwan
    • The korean journal of orthodontics
    • /
    • v.27 no.3 s.62
    • /
    • pp.411-420
    • /
    • 1997
  • The propose of this study was to quantify the changes of soft tissue profile following orthodontic treatment and to evaluate the relationship of those to the skeletal elements. Pre-and post-treatment lateral cephalometric head films of 40 cases(20 extraction cases, 20 non-extraction cases) were traced, and the changes following treatment were measured and quantified by digital subtraction method, and statisticall analyzed. The obtained results were as follows; 1. in extraction group, the change of upper lip area(UL) was $558.60\pm355.17$ pixels, that of lower lip area(LL) was $941.15\pm364.07$ pixels. But, in non-extraction group the change of uper lip area(UL) was $125.65\pm404.16$ pixels, that of lower lip area(LL) was $104.05\pm440.93$ pixels, which was significantly lesser than those in extraction group. 2. In extraction group, there was significant correlationship between upper lip area change(UL) and difference of upper incisor point(${\Delta}UIP$). Lower lip area change(LL) was significantly correlated with difference of upper incisor(${\Delta}UIP$), difference of Franlrfort upper incisor angle(${\Delta}FUIA$) or difference of interincisal angle(${\Delta}IIA$). 3. In extraction group, the ratio of difference of upper incisor point(${\Delta}UIP$) to difference of labrale superius(${\Delta}LSP$) was 1.68; difference of lower incisor point(${\Delta}LIP$) to difference of labrale inferius(${\Delta}LI$) was 1.19; difference of upper incisor point(${\Delta}UIP$) to increment in upper lip thickness(${\Delta}TUL$) was 1.95. 4. In non-extraction group, there was a significant correlationship between upper lip area change(UL) and difference of upper incisor point(${\Delta}UIP$).

  • PDF