• 제목/요약/키워드: 취출구 소음

검색결과 5건 처리시간 0.023초

공기조화 취출구 소음 평가를 위한 물리지수 분석 (Analysis of Physical Parameters for the Evaluation of HVAC Diffuser Noise)

  • 박현구;김항;고성석;김선우
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.402-405
    • /
    • 2006
  • The diffuser noise of HVAC(heating ventilating and air-conditioning) uses dB(A) or NC as a indoor noise criteria that ASHRAE represents, and there is no specific guide line for application. According to the previous study, there are some problems like that even though the sound level of sound source is same, the NC shows different values, which makes the noise rating confused. This problem is caused by the frequency characteristics of sound source and its sound level. Therefore, appropriate evaluation method should be considered based on the subjective responses. This study aims to analyze the physical parameters appropriate for the evaluation of HVAC diffuser noise. To achieve this, recording of sound sources, calculation of physical parameters and psycho-acoustic experiment were carried out and the results were derived from the correlation analysis between physical parameters and subjective evaluatio

  • PDF

공기조화 취출구 소음의 평가요인에 관한 연구 (A Study on the Evaluation Factors for Diffuser Noise of HVAC)

  • 박현구;김항;김선우
    • 한국소음진동공학회논문집
    • /
    • 제16권2호
    • /
    • pp.149-155
    • /
    • 2006
  • There are various types of noise around us such as road traffic noise, aircraft noise and floor impact sound, equipment noise, etc. Researches on the noise criteria and the evaluation method for the diffuser noise of HVAC are insufficient. dB(A) and NC values represented in ASHRAE guide book are applied as a noise criteria for diffuser noise, which have some problems like that the values between dB(A) and NC have deviation even if the sound is same one. Therefore, the evaluation method should be considered and proposed based on the subjective responses. From these reasons, this study aimed to analyze the evaluation factors for the diffuser noise of HVAC reflected on the subjective responses by surveying vocabularies and grouping them with factor analysis.

공기조화 취출구 소음의 평가요인 설정에 관한 연구 (A Study on the Evaluation Factors for Diffuser Noise of HVAC)

  • 박현구;김항;김원식;김선우
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.349-354
    • /
    • 2005
  • There are various types of noise around us such as road traffic noise, aircraft noise and floor impact sound, equipment noise etc. Recently researches on the criteria to evaluate the noises have been progressed, however, researches on the noise criteria and evaluation method for the diffuser noise of HVAC are insufficient. dB(A) and NC values represented in ASHRAE guide book are applied as a noise criteria for diffuser noise, which have some problems like that the values between dB(A) and NC have deviation even if the sound is same one. Therefore, the evaluation method should be considered and proposed based on the subjective responses. From these reasons, this study aimed to analyze the evaluation factors for the diffuser noise of HVAC reflected on the subjective responses by surveying vocabularies and grouping them with factor analysis.

  • PDF

Auto Louver를 갖는 가전제품의 소음저감 및 음질개선 방법 (A Method of Noise Reduction and Improvement in Sound Quality for a Product with the Auto Louver)

  • 한재오;구형모;최원석;김진백
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 추계학술대회논문집
    • /
    • pp.1073-1075
    • /
    • 2003
  • 본 글은 가전제품의 안전성, 고급화 및 기능의 차별화를 목적으로 Auto Louver를 설치하는 경우에 있어서 부수적으로 발생하는 2차적 소음에 대해 음질개선 및 소음저감 방법을 소개한다. 실험은 제품의 토출구에 안전망이 설치되고 그 뒤에 Auto Louver를 부착한 자사의 Air Cleaner를 대상으로 실시하였으며, 임의의 공기가 토출되는 조건에서 Auto Louver의 Blade 길이를 줄여 안전망과 Blade 끝단까지의 거리를 이격시킴으로서 1.2KHz-2.5KHz 주파수 대역의 SPL의 저감을 통해 음질을 개선하였고, 이로 인해 토출구로부터 1m 떨어진 위치에서의 소음 측정값을 1.1㏈A의 저감하는 효과를 얻을 수 있었다.

  • PDF

사무소 건물의 공조설비소음 특성 (The Characteristics of HVAC Noise in Office Buildings)

  • 도영주;김동규;김흥식
    • 한국음향학회지
    • /
    • 제8권1호
    • /
    • pp.59-66
    • /
    • 1989
  • 공조설비소음의 특성을 파악하기 위하여 서울의 도심에 위치한 고층 사무소 건물을 대상으로 송풍기의 파워레벨과 취출구를 통한 실내소음레벨을 측정하였다. 또한 공조설비소음이 문제시되는 건물에 흡음챔버와 사이드브랜치를 설치하여 소음기의 감음성능을 평가하였다. 연구의 결과, 실내소음레벨은 송풍기 발생소음의 영향으로 500Hz 이하의 저주파수 대역에서 ISO의 허용 기준치인 NR40을 초과하였으며 흠음챔버는 넓은 대역의 주파수, 사이드브랜치는 특정공명주파수에서 감음효과가 크게 나타났다.

  • PDF