• Title/Summary/Keyword: 취약부

Search Result 764, Processing Time 0.03 seconds

Structural Weak Area Analysis of an Electric Car Bogie Frame by Finite Element Analysis (유한요소 해석에 의한 전동차 대차 프레임의 구조 취약부 해석)

  • Goo Byeong-Choon;Whang Won-Joo;Choi Sung-Kyu;Oh Il-Geun
    • Proceedings of the KSR Conference
    • /
    • 2004.10a
    • /
    • pp.628-633
    • /
    • 2004
  • we studied the structural weak areas of an electric car bogie frame by finite element analysis. The bogie frame under consideration is a part of the standard electric car with aluminium car body. Vertical, torsional. lateral and longitudinal loadings were applied. Numerical results were compared with the experimental results. The two results are in a good agreement.

  • PDF

Detection of Damage at the Ends of Members using Finite Model Updating and Semi Rigid Connection Model (모델개선기법과 반강접 접합부 모델을 이용한 부재단부 손상탐지)

  • Yu, Eun-Jong;Kim, Seung-Nam;Lee, Hyun-Kook;Choi, Hang
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2010.04a
    • /
    • pp.692-695
    • /
    • 2010
  • 일반적으로 모델개선에서는 부재단위의 강성을 파악하기 때문에 구조물의 취약부인 부재단부의 손상이 집중될 경우 손상의 형태를 세밀히 파악하기 어려우며 손상된 구조물의 거동을 정확하게 모사하기 어려운 단점이 있었다. 이를 해결하기 위해서는 부재 단부에 발생한 손상을 고려할 수 있는 좀 더 정밀한 해석 모델을 통한 모델개선이 필요하다. 본 연구에서는 부재 단부에 반강접 접합을 가지는 해석모델을 사용해 모델 개선을 실시하고 이를 통해 접합부의 손상 평가와 손상 구조물의 거동을 파악하였다. 제안된 방법을 5층 1경간의 RC 벽식 실험체의 손상탐지에 적용하였으며 그 결과 부재단위 모델을 사용할 때보다 더욱 정확하게 구조물의 손상을 평가하고 거동을 모사할 수 있었다.

  • PDF

Assessment of stream water demand using water supply safety (이수안전도를 이용한 하천수 수요 평가)

  • Sang Young Bae;Jang Hyun Sung;Eui Hyeok Yoon;Mi Ra Kim
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.445-445
    • /
    • 2023
  • 하천수 수요는 생활, 공업, 농업 등 인위적 사용 그리고 하천의 환경개선, 건천화 방지 및 물 재이용 등과 관련된 하천유지유량으로 구분된다. 현행 수자원 관리는 갈수 시에도 안정적인 취수가 가능하도록 운영하고 있어, 하천수 취수(사용)의 신규 또는 변경 허가를 위한 허가기준유량의 개념 및 관리는 자연, 사회적 하천수 수요 관리에 매우 중요한 인자이다. 본 연구에서는 하천수의공급 능력을 평가하기 위하여, 댐의 이수안전도를 나타내는 지표를 이용하여 허가기준유량을 평가하였다. 신뢰도(reliability), 회복도(resilience) 및 취약도(vulnerability)를 기준으로 하천유지유량고시 지점과 유량 조사 지점이었고 분석 결과, 부족 발생 시에 이를 회복하는 능력에서 지점별 큰 차이가 확인되었고, 이로부터 하천수 관리 현황과 개선점을 제시하였다.

  • PDF

A Study on the Shear Characteristic of├ Type Reinforced Concrete Joints under Cyclic Loading (반복하중을 받는 ├형 철근콘크리트 접합부의 전단특성에 관한 연구)

  • 이상호;이동화
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.5 no.2
    • /
    • pp.73-82
    • /
    • 2001
  • 본 연구는 실험적 방법과 해석적 방법을 통하여 반복하중을 받는 ├형 철근콘크리트 접합부의 전단특성을 파악함을 목적으로 한다. ├형 접합부는 고강도 재료의 사용으로 인한 체적의 감소 뿐만 아니라, 지진발생 시 반복하중의 작용으로 인한 변동축력 등으로 , 구조적으로 취약한 부분이 될 가능성이 있다. 따라서 본 연구에서는 ├형 접합부의 전단특성을 파악하기 위하여 기동축력, 콘크리트 압축강도, 접합부 전단보강근비를 변수로 한 12개의 실험체를 제작하여 가력실험을 수행하였다. 또한, 유한요소 해석을 수행하여 본 실험결과와의 비교 검토를 통하여 타당성을 검토한 후, 기둥축력과 콘크리트 압축강도의 변화에 대한 변수해석을 통하여 접합부의 전단강도에 미치는 변수는 영향을 파악하였으며, 실험에 의한 실험체의 전단내력을 기존에 제안된 AIJ, ACI 규준 등과 비교 검토하였다. 본 연구의 결로부터 기둥축력과 콘크리트 압축강도가 ├형 철근콘크리트 접합부의 전단강도에 미치는 영향을 확인하였다.

  • PDF

A Comparative Study on the Behavior of High-rise Buildings by 2D and 3D Dynamic Analysis with Considering the Ground (초고층 건물의 지반을 고려한 2D 및 3D 동적해석에 의한 거동 비교 연구)

  • You, Kwangho;Baek, Yong;Kim, Seungjin
    • Journal of the Korean GEO-environmental Society
    • /
    • v.20 no.10
    • /
    • pp.5-14
    • /
    • 2019
  • Recently, earthquakes have occurred in our country and seismic stability of high-rise buildings in large cities is being a growing interest and thus the related studies have been increased. Also the grounds are considered indirectly in most of seismic designs and analyses and seismic researches based on 3D dynamic analysis are insufficient. In this study, therefore, 2D and 3D dynamic analyses were performed based on the SSI complete model including grounds and the behavior was compared and analyzed. For dynamic modeling, linear time history analyses were performed by using MIDAS GTS NX. For this purpose, a high-rise building was assumed to be constructed on top of the bedrock and surrounded by a surface layer. A sensitivity analysis was performed with the selected parameters. The dynamic behavior was compared and analyzed in terms of horizontal displacements, drift ratios, bending stresses, and weak parts. In most cases, 2D dynamic behavior was calculated to be larger than 3D's and thus it shows more conservative results with increasing number and size of weak parts.

Study on Improving Proximity Evaluation Standards when Excavating Tunnels Adjacent to Urban Infrastructure (도시기반시설 인접 터널 굴착시 근접도 평가기준 개선방안 연구)

  • Chul Lee;Guk-Hwan Cho
    • Tunnel and Underground Space
    • /
    • v.34 no.4
    • /
    • pp.283-300
    • /
    • 2024
  • Due to the revitalization of urban development, the number of cases of excavating tunnels adjacent to existing subways is increasing. This may affect the structure and track of the existing subway, resulting in reduced stability and usability. In this study, we verified the adequacy of the proximity evaluation range to ensure the stability of new tunnels and existing subways when excavating adjacent to tunnels, and proposed a quantitative correction rate considering various conditions. Conditions for applying the correction rate considered rock grade, geologically weak section, structurally weak section, and structural deterioration section. It is hoped that a more accurate proximity evaluation will be performed by applying a quantitative correction rate that considers rock and geological conditions, structure status, etc. to the proximity evaluation standard.

Vulnerability Mitigation System Construction Method Based on ATT&CK in M ilitary Internal Network Environment (국방 네트워크 환경에서 ATT&CK 기반 취약점 완화 체계 구축 방안)

  • Ahn, Gwang Hyun;Lee, Hanhee;Park, Won Hyung;Kang, Ji Won
    • Convergence Security Journal
    • /
    • v.20 no.4
    • /
    • pp.135-141
    • /
    • 2020
  • The Ministry of National Defense is strengthening the power and capacity of cyber operations as cyber protection training is conducted. However, considering the level of enemy cyber attack capability, the level of cyber defense capability of the ministry of national defense is significantly low and the protection measures and response system for responding to cyber threats to military networks are not clearly designed, falling short of the level of cyber security capabilities of the public and private sectors. Therefore, this paper is to investigate and verify the establishment of a military internal network vulnerability mitigation system that applies the intention of attackers, tactics, techniques and procedures information (ATT&CK Framework), identified military internal network main threat information, and military information system security requirements with military specificity as factors that can establish a defense network vulnerability mitigation system by referring to the domestic and foreign cyber security framework It has the advantage of having.

Assessment of Landslide on Climate Change using GIS (GIS를 이용한 기후변화에 따른 산사태 취약성 평가)

  • Xu, Zhen;Kwak, Hanbin;Lee, Woo-Kyun;Park, Taejin;Kwon, Tae-Hyub;Park, Sunmin
    • Journal of Climate Change Research
    • /
    • v.2 no.1
    • /
    • pp.43-54
    • /
    • 2011
  • Recently, due to severe rainfall by the global climate change, natural disasters such as landslide had also been increased rapidly all over the world. Therefore, it has been very necessary to assess vulnerability of landslide and prepare adaptation measures to future climate change. In this study, we employed sensitivity, exposure and adaptative capacity as criteria for assessing the vulnerability of landslide due to climate change. Spatial database for the criteria was constructed using GIS technology. And vulnerability maps on the entire Korea of past and future were made based on the database. As a result, highly vulnerable area for landslide was detected in most area of Gangwon-do, the east of Gyeonggi-do, and southeast of Jeollanam-do, and the southwest of Gyeongsangnam-do. The result of landslide vulnerability depends on time shows that degree of very low class and low class were decreased and degree of moderate, high, and very high were increase from past to the future. Especially, these three classes above low class were significantly increased in the result of far future.

Case Study of the Stability of a Large Cut-Slope at a Tunnel Portal (터널 입구부 대절토 사면 안정성 사례 연구)

  • Park, Dong Soon;Bae, Jong-Soem
    • The Journal of Engineering Geology
    • /
    • v.25 no.1
    • /
    • pp.115-129
    • /
    • 2015
  • The cut-slope of a large-sectional tunnel portal is recognized as a potential area of weakness due to unstable stress distribution and possible permanent displacement. This paper presents a case study of a slope failure and remediation for a large-scale cut-slope at a tunnel portal. Extensive rock-slope brittle failure occurred along discontinuities in the rock mass after 46 mm of rainfall, which caused instability of the upper part of the cut-slope. Based on a geological survey and face mapping, the reason for failure is believed to be the presence of thin clay fill in discontinuities in the weathered rock mass and consequent saturationinduced joint weakening. The granite-gneiss rock mass has a high content of alkali-feldspar, indicating a vulnerability to weathering. Immediately before the slope failure, a sharp increase in displacement rate was indicated by settlement-time histories, and this observation can contribute to the safety management criteria for slope stability. In this case study, emergency remediation was performed to prevent further hazard and to facilitate reconstruction, and counterweight fill and concrete filling of voids were successfully applied. For ultimate remediation, the grid anchor-blocks were used for slope stabilization, and additional rock bolts and grouting were applied inside the tunnel. Limit-equilibrium slope stability analysis and analyses of strereographic projections confirmed the instability of the original slope and the effectiveness of reinforcing methods. After the application of reinforcing measures, instrumental monitoring indicated that the slope and the tunnel remained stable. This case study is expected to serve as a valuable reference for similar engineering cases of large-sectional slope stability.

Analysis of flood and drought disaster risks in the Mekong Delta (메콩 삼각주의 홍수 및 가뭄 재해 위험 분석)

  • Ko, Ick Hwan;Choi, Byung Man;Kim, Jeongkon;Kim, Eugene
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2019.05a
    • /
    • pp.55-55
    • /
    • 2019
  • 메콩강 유역에서 가장 하류에 위치하고 있는 메콩 삼각주는 상류에 일어나는 많은 활동으로 인하여 높은 수준의 취약성을 지니고 있다. 기후 변화와 미래개발의 맥락에서 재해 위험을 평가하는 것은 기후현상/극한날씨, 취약성, 노출, 현재 위험 관리 및 적응을 충분히 고려할 필요가 있다. 홍수, 가뭄, 염수침입은 IQQQM과 IS 모델을 사용하여 분석하였다. 베트남 정부가 승인한 최신 기후변화 시나리오는 이 지역의 향후 토지이용, 물이용 및 상류에서의 수력발전 계획과 함께 모델링에 사용되었다. 홍수, 가뭄 및 염수치입 정도를 시뮬레이션 결과에 기초하여 평가하였고, 최종적으로 GIS 도구를 사용한 위험도 분석을 실시하였다. 리스크 분석 결과 저위험구역의 2모작 및 3모작 논의 면적은 6,381 ha로 떨어지고 중위험지역과 고위험구역의 2모작과 양식장 면적은 각각 약 7만 ha와 9,000 ha로 늘어나는 것으로 나타났다. 가뭄과 염도에 대한 위험 분석은 기후 변화와 해수면 상승으로 인한 위험의 심각성이 증가하는 것을 나타낸다. 분석 결과 메콩 삼각주에서는 전반적으로 향후 기후변화와 상류발전에 따른 부정적 영향으로 홍수 및 가뭄재해의 위험이 증가할 것으로 나타났다. 홍수 및 가뭄에 대한 보다 능동적이고 협력적인 관리가 향후 재난에 대비하여 지역사회의 탄력성을 유지하기 위해 필요한 것으로 나타났다.

  • PDF